首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
H J Koester  D Baur  R Uhl    S W Hell 《Biophysical journal》1999,77(4):2226-2236
The signal and limitations of calcium florescence imaging using nonresonant multiphoton absorption of near-infrared femto- and picosecond laser pulses were examined. The fluorescence changes of various Ca(2+)-indicators induced by transient increases of the intradendritic calcium concentration were evaluated by evoking physiological activity in neocortical neurons in rat brain slices. Photodamage was noticeable as irreversible changes in the parameters describing the calcium fluorescence transients. At higher two-photon excitation rates, a great variety of irregular functional and structural alterations occurred. Thus, signal and observation time were limited by phototoxic effects. At lower excitation rates, photodamage accumulated linearly with exposure time. Femtosecond and picosecond laser pulses were directly compared with respect to this cumulative photodamage. The variation of the pulse length at a constant two-photon excitation rate indicated that a two-photon excitation mechanism is mainly responsible for the cumulative photodamage within the investigated window of 75 fs to 3.2 ps. As a direct consequence, at low excitation rates, the same image quality is achieved irrespective of whether two-photon Ca(2+)-imaging is carried out with femto- or picosecond laser pulses.  相似文献   

2.
Photobleaching in two-photon excitation microscopy   总被引:10,自引:0,他引:10       下载免费PDF全文
The intensity-squared dependence of two-photon excitation in laser scanning microscopy restricts excitation to the focal plane and leads to decreased photobleaching in thick samples. However, the high photon flux used in these experiments can potentially lead to higher-order photon interactions within the focal volume. The excitation power dependence of the fluorescence intensity and the photobleaching rate of thin fluorescence samples ( approximately 1 microm) were examined under one- and two-photon excitation. As expected, log-log plots of excitation power versus the fluorescence intensity and photobleaching rate for one-photon excitation of fluorescein increased with a slope of approximately 1. A similar plot of the fluorescence intensity versus two-photon excitation power increased with a slope of approximately 2. However, the two-photon photobleaching rate increased with a slope > or =3, indicating the presence of higher-order photon interactions. Similar experiments on Indo-1, NADH, and aminocoumarin produced similar results and suggest that this higher-order photobleaching is common in two-photon excitation microscopy. As a consequence, the use of multi-photon excitation microscopy to study thin samples may be limited by increased photobleaching.  相似文献   

3.
We describe a custom one-photon (confocal) and two-photon all-digital (photon counting) laser scanning microscope. The confocal component uses two avalanche photodiodes (APDs) as the fluorescence detector to achieve high sensitivity and to overcome the limited photon counting rate of a single APD ( approximately 5 MHz). The confocal component is approximately nine times more efficient than our commercial confocal microscope (fluorophore fluo 4). Switching from one-photon to two-photon excitation mode (Ti:sapphire laser) is accomplished by moving a single mirror beneath the objective lens. The pulse from the Ti:sapphire laser is 109 fs in duration at the specimen plane, and average power is approximately 5 mW. Two-photon excited fluorescence is detected by a fast photomultiplier tube. With a x63 1.4 NA oil-immersion objective, the resolution of the confocal system is 0.25 microm laterally and 0.52 microm axially. For the two-photon system, the corresponding values are 0.28 and 0.82 microm. The system is advantageous when excitation intensity must be limited, when fluorescence is low, or when thick, scattering specimens are being studied (with two-photon excitation).  相似文献   

4.
The two-photon excitation fluorescence (TPEF) process of an enhanced green fluorescent protein (EGFP) for fluorescence signals was adaptively controlled by the phase-modulation of femtosecond pulses. After the iteration of pulse shaping, a twofold increase in the ratio of the fluorescence signal to the laser peak power was achieved. Compared with conventional pulses optimized for peak power, phase-optimized laser pulses reduced the bleaching rate of EGFP by a factor of 4 while maintaining the same intensity of the fluorescence signal. Our method will provide a powerful solution to various problems confronting researchers, such as the photobleaching of dyes in two-photon excitation microscopy.  相似文献   

5.
We demonstrate the direct 1064 nm two-photon excitation of hematoporphyrin derivative (HPD), a complex mixture of photosensitizing porphyrins which is selectively retained in tumor tissue and used in cancer photochemotherapy. Although 1064 nm is outside of the one-photon HPD absorption spectrum, two-photon induced fluorescence from HPD was observed following excitation by the 20 ns output of an amplified, Q-switched Nd-YAG laser at peak power levels of 0.1 to 3 GW/cm2. Evidence for the successful two-photon excitation to vibrational levels of the S1 state consists of the observation of the known HPD fluorescence spectrum exhibiting peaks at approximately 615 and 675 nm, with the observed two-photon induced fluorescence intensity exhibiting a quadratic dependence on the excitation laser intensity as required for a direct two-photon process. More generally, these results suggest the possibility for the achievement of photosensitized oxidations utilizing photons of lower energy than that required for single photon excitation, offering the potential for both greater selectivity and a reduction in competing photochemical processes.  相似文献   

6.
Picosecond multiphoton scanning near-field optical microscopy.   总被引:2,自引:0,他引:2       下载免费PDF全文
We have implemented simultaneous picosecond pulsed two- and three-photon excitation of near-UV and visible absorbing fluorophores in a scanning near-field optical microscope (SNOM). The 1064-nm emission from a pulsed Nd:YVO4 laser was used to excite the visible mitochondrial specific dye MitoTracker Orange CM-H2TMRos or a Cy3-labeled antibody by two-photon excitation, and the UV absorbing DNA dyes DAPI and the bisbenzimidazole BBI-342 by three-photon excitation, in a shared aperture SNOM using uncoated fiber tips. Both organelles in human breast adenocarcinoma cells (MCF 7) and specific protein bands on polytene chromosomes of Drosophila melanogaster doubly labeled with a UV and visible dye were readily imaged without photodamage to the specimens. The fluorescence intensities showed the expected nonlinear dependence on the excitation power over the range of 5-40 mW. An analysis of the dependence of fluorescence intensity on the tip-sample displacement normal to the sample surface revealed a higher-order function for the two-photon excitation compared to the one-photon mode. In addition, the sample photobleaching patterns corresponding to one- and two-photon modes revealed a greater lateral confinement of the excitation in the two-photon case. Thus, as in optical microscopy, two-photon excitation in SNOM is confined to a smaller volume.  相似文献   

7.
P Schwille  U Haupts  S Maiti    W W Webb 《Biophysical journal》1999,77(4):2251-2265
Multiphoton excitation (MPE) of fluorescent probes has become an attractive alternative in biological applications of laser scanning microscopy because many problems encountered in spectroscopic measurements of living tissue such as light scattering, autofluorescence, and photodamage can be reduced. The present study investigates the characteristics of two-photon excitation (2PE) in comparison with confocal one-photon excitation (1PE) for intracellular applications of fluorescence correlation spectroscopy (FCS). FCS is an attractive method of measuring molecular concentrations, mobility parameters, chemical kinetics, and fluorescence photophysics. Several FCS applications in mammalian and plant cells are outlined, to illustrate the capabilities of both 1PE and 2PE. Photophysical properties of fluorophores required for quantitative FCS in tissues are analyzed. Measurements in live cells and on cell membranes are feasible with reasonable signal-to-noise ratios, even with fluorophore concentrations as low as the single-molecule level in the sampling volume. Molecular mobilities can be measured over a wide range of characteristic time constants from approximately 10(-3) to 10(3) ms. While both excitation alternatives work well for intracellular FCS in thin preparations, 2PE can substantially improve signal quality in turbid preparations like plant cells and deep cell layers in tissue. At comparable signal levels, 2PE minimizes photobleaching in spatially restrictive cellular compartments, thereby preserving long-term signal acquisition.  相似文献   

8.
Ji N  Magee JC  Betzig E 《Nature methods》2008,5(2):197-202
Pulsed lasers are key elements in nonlinear bioimaging techniques such as two-photon fluorescence excitation (TPE) microscopy. Typically, however, only a percent or less of the laser power available can be delivered to the sample before photoinduced damage becomes excessive. Here we describe a passive pulse splitter that converts each laser pulse into a fixed number of sub-pulses of equal energy. We applied the splitter to TPE imaging of fixed mouse brain slices labeled with GFP and show that, in different power regimes, the splitter can be used either to increase the signal rate more than 100-fold or to reduce the rate of photobleaching by over fourfold. In living specimens, the gains were even greater: a ninefold reduction in photobleaching during in vivo imaging of Caenorhabditis elegans larvae, and a six- to 20-fold decrease in the rate of photodamage during calcium imaging of rat hippocampal brain slices.  相似文献   

9.
Two-photon fluorescence excitation has been found to be a very powerful method for enhancing the sensitivity and resolution in far-field light microscopy. Two-photon fluorescence excitation also provides a substantially background-free detection on the single-molecule level. It allows direct monitoring of formation of labelled biomolecule complexes in solution. Two-photon excitation is created when, by focusing an intensive light source, the density of photons per unit volume and per unit time becomes high enough for two photons to be absorbed into the same chromophore. In this case, the absorbed energy is the sum of the energies of the two photons. In two-photon excitation, dye molecules are excited only when both photons are absorbed simultaneously. The probability of absorption of two photons is equal to the product of probability distributions of absorption of the single photons. The emission of two photons is thus a quadratic process with respect to illumination intensity. Thus in two-photon excitation, only the fluorescence that is formed in the clearly restricted three-dimensional vicinity of the focal point is excited. We have developed an assay concept that is able to distinguish optically between the signal emitted from a microparticle in the focal point of the laser beam, and the signal emitted from the surrounding free labelled reagent. Moreover, the free labels outside the focal volume do not contribute any significant signal. This means that the assay is separation-free. The method based on two-photon fluorescence excitation makes possible fast single-step and separation-free immunoassays, for example, for whole blood samples. Since the method allows a separation-free assay in very small volumes, the method is very useful for high-throughput screening assays. Consequently we believe that two-photon fluorescence excitation will make a remarkable impact as a research tool and a routine method in many fields of analysis.  相似文献   

10.
Multiphoton imaging has evolved as an indispensable tool in cell biology and holds prospects for clinical applications. When addressing endogenous signals such as coherent anti-Stokes Raman scattering (CARS) or second harmonic generation, it requires intense laser irradiation that may cause photodamage. We report that increasing endogenous fluorescence signal upon multiphoton imaging constitutes a marker of photodamage. The effect was studied on mouse brain in vivo and ex vivo, on ex vivo human brain tissue samples, as well as on glioblastoma cells in vitro, demonstrating that this phenomenon is common to a variety of different systems, both ex vivo and in vivo. CARS microscopy and vibrational spectroscopy were used to analyze the photodamage. The development of a standard easy-to-use model that employs rehydrated cryosections allowed the characterization of the irradiation-induced fluorescence and related it to nonlinear photodamage. In conclusion, the monitoring of endogenous two-photon excited fluorescence during label-free multiphoton microscopy enables to estimate damage thresholds ex vivo as well as detect photodamage during in vivo experiments.  相似文献   

11.
Fluorescence detection is extensively used in high throughput screening. In HTS there is a continuous migration toward higher density plates and smaller sample volumes. In the present report we describe the advantages of two-photon or multiphoton excitation for HTS. Multiphoton excitation (MPE) is the simultaneous absorption of two long-wavelength photons to excite the lowest singlet state of the fluorophore. MPE is typically accomplished with short but high-intensity laser pulses, which allows simultaneous absorption of two or more photons. The intensity of the multiphoton-induced fluorescence is proportional to the square, cube, or higher power of the instantneous photon flux. Consequently, two-photon or multiphoton excitation only occurs at the focal point of the incident beam. This property of two-photon excitation allows the excited volume to be very small and to be localized in the center of each well in the HTS plate. We show that two-photon-induced fluorescence of fluorescein can be reliably measured in microwell plates. We also show the use of 6-carboxy fluorescein as a pH probe with two-photon excitation, and measure 4'-6-diamidino-2-phenylindole (DAPI) binding and two-photon-induced fluorescence. In further studies we measure the time-dependent intensity decays of DAPI bound to DNA and of calcium-dependent fluorophores. Finally, we demonstrate the possibility of three-photon excitation of several fluorophores, including indole, in the HTS plate. These results suggest that MPE can be used in high-density multiwell plates.  相似文献   

12.
Two-photon excitation microscopy provides attractive advantages over confocal microscopy for three-dimensionally resolved fluorescence imaging. Since two-photon excitation occurs only at the focal point of the microscope, it inherently provides three-dimensional resolution. This localization of excitation also minimizes photobleaching and photodamage, which are the ultimate limiting factors in imaging living cells. Furthermore, no pinhole is required to attain three-dimensional discrimination, so the efficiency of fluorescence collection is increased. These advantages allow experiments on thick living samples that would not be possible with other imaging techniques. The cost and complexity of the lasers required for two-photon excitation microscopy have limited its use, but appropriate turn-key lasers have now been introduced, and their cost should decrease. Finally, the recent introduction of commercial two-photon excitation laser-scanning microscope systems allows a much larger group of researchers access to this state-of-the-art methodology.  相似文献   

13.
In this paper, we report the first successful demonstration, to our knowledge, of two-photon fluorescence excitation (TPFE) using planar thin-film waveguide structures of macroscopic excitation dimensions (square millimeters to square centimeters in size). The high intensity of excitation light required for TPFE is available not only at a single focus point but along the whole trace of the beam guided in the waveguide structure. Line profiles of the fluorescence excited by TPFE show excellent correlation with the geometry of the launched laser beams. A clear second-order dependence of the fluorescence intensity on the excitation intensity confirms the two-photon character of fluorescence generation. Spectra of the emission generated by one-photon excitation and by two-photon excitation show only minor differences.  相似文献   

14.
Continuous wave two-photon scanning near-field optical microscopy.   总被引:1,自引:0,他引:1       下载免费PDF全文
We have implemented continuous-wave two-photon excitation of near-UV absorbing fluorophores in a scanning near-field optical microscope (SNOM). The 647-nm emission of an Ar-Kr mixed gas laser was used to excite the UV-absorbing DNA dyes DAPI, the bisbenzimidazole Hoechst 33342, and ethidium bromide in a shared aperture SNOM with uncoated fiber tips. Polytene chromosomes of Drosophila melanogaster and the nuclei of 3T3 Balb/c cells labeled with these dyes were readily imaged. The fluorescence intensity showed the expected nonlinear (second order) dependence on the excitation power in the range of 8-180 mW. We measured the fluorescence intensity as a function of the tip-sample displacement in the direction normal to the sample surface in the single- and two-photon excitation modes (SPE, TPE). The fluorescence intensity decayed faster in TPE than in SPE.  相似文献   

15.
Combination of green fluorescent protein (GFP) and two-photon excitation fluorescence microscopy (TPE) has been used increasingly to study dynamic biochemical events within living cells, sometimes even in vivo. However, the high photon flux required in TPE may lead to higher-order photobleaching within the focal volume, which would introduce misinterpretation about the fine biochemical events. Here we first studied the high-order photobleaching rate of GFP inside live cells by measuring the dependence of the photobleaching rate on the excitation power. The photobleaching rate under one- and two-photon excitation increased with 1-power and 4-power of the incident intensity, respectively, implying the excitation photons might interact with excited fluorophore molecules and increase the probability of photobleaching. These results suggest that in applications where two-photon imaging of GFP is used to study dynamic molecular process, photobleaching may ruin the imaging results and attention should be paid in interpreting the imaging results.  相似文献   

16.
We studied one- and two-photon induced fluorescence of Pacific Blue (PB)-labeled human serum albumin (HSA) in the presence of different size silver colloids. The PB fluorescence emission intensity was observed with small (30-40 nm) and large (about 120 nm) colloids and compared with PB emission in absence of colloids. For the system with a small core size colloids we did not detect any fluorescence enhancement with one-photon excitation and the enhancement observed with two-photon excitation was about 2.5-fold. In contrast, for large silver colloids we observed about a 2-fold increase in PB fluorescence brightness for one-photon excitation, and the enhancement with two-photon excitation excided 13-folds. Much stronger increases in brightness observed with two-photon excitation, compared to one-photon excitation, indicate a dominant role of enhanced local field in fluorescence enhancement on silver colloids in solutions.  相似文献   

17.
Two-photon probe excitation data are commonly presented as absorption cross section or molecular brightness (the detected fluorescence rate per molecule). We report two-photon molecular brightness spectra for a diverse set of organic and genetically encoded probes with an automated spectroscopic system based on fluorescence correlation spectroscopy. The two-photon action cross section can be extracted from molecular brightness measurements at low excitation intensities, while peak molecular brightness (the maximum molecular brightness with increasing excitation intensity) is measured at higher intensities at which probe photophysical effects become significant. The spectral shape of these two parameters was similar across all dye families tested. Peak molecular brightness spectra, which can be obtained rapidly and with reduced experimental complexity, can thus serve as a first-order approximation to cross-section spectra in determining optimal wavelengths for two-photon excitation, while providing additional information pertaining to probe photostability. The data shown should assist in probe choice and experimental design for multiphoton microscopy studies. Further, we show that, by the addition of a passive pulse splitter, nonlinear bleaching can be reduced--resulting in an enhancement of the fluorescence signal in fluorescence correlation spectroscopy by a factor of two. This increase in fluorescence signal, together with the observed resemblance of action cross section and peak brightness spectra, suggests higher-order photobleaching pathways for two-photon excitation.  相似文献   

18.
We present a chlorophyll fluorometer module system which adapts the intensity to the individual leaf sample by adjusting the quantum flux density of the excitation light so that the fluorescence signal is kept constant. This is achieved by means of a feedback power adjustment of the fluorescence exciting laser diode. Thus, the intensity of the excitation light is adapted to the actual need of a particular sample for quantum conversion without applying exaggeratedly high quantum flux density. We demonstrate the influence of the initial laser power chosen at the onset of irradiation and kept constant during fluorescence rise transient within the first second. Examples are shown for measuring upper and lower leaf sides, a single leaf with different pre-darkening periods, as well as yellow, light green and dark green leaves. The novel excitation kinetics during the induction of chlorophyll fluorescence can be used to study the yield and regulation of photosynthesis and its related non-photochemical processes for an individual leaf. It allows not only to sense the present state of pre-darkening or pre-irradiation but also the light environment the leaf has experienced during its growth and development. Thus, the individual physiological capacity and plasticity of each leaf sample can be sensed being of high importance for basic and applied ecophysiological research which makes this new methodology both innovative and informative.  相似文献   

19.
We applied two-photon laser-scanning microscopy (TPLSM) to motion-sensitive visual interneurons of the fly to study Ca(2+) dynamics in vivo at a higher spatial and temporal resolution than possible with conventional fluorescence microscopy. Based on a custom-built two-photon microscope, we performed line scans to measure changes in presynaptic Ca(2+) concentrations elicited by visual stimulation. We used a fast avalanche photodiode (APD) with a high quantum efficiency to detect even low levels of emitted fluorescence. Our experiments show that our in vivo preparation is amenable to TPLSM: with excitation intensities low enough not to cause photodamage, activity-dependent fluorescence changes of Ca(2+)-sensitive dyes can be detected in small neuronal branches. The performance of two-photon and conventional Ca(2+) imaging carried out consecutively at the same neuron is compared and it is demonstrated that two-photon imaging allows us to detect differences in Ca(2+) dynamics between individual neurites.  相似文献   

20.
The tumor-localizing photosensitizer hematoporphyrin derivative (HPD) is shown to undergo a simultaneous two-photon excitation into the near-ultraviolet Soret band system upon intense laser irradiation at 750 nm, a spectral region where there is no significant HPD one-photon absorbance in aqueous solution. Subsequent to this excitation, internal conversion and vibrational relaxation occur, resulting in the population of the vibrationless level of the first electronically excited singlet state. This state relaxes by two channels, the emission of fluorescence in the spectral region 600-700 nm and intersystem crossing into the triplet manifold, followed by near-resonant electronic energy transfer with surrounding oxygen to result in the generation of highly reactive singlet molecular oxygen (1 delta g). Evidence for the two-photon excitation consists in the observation both of the HPD fluorescence spectrum in the region of 615 nm as a result of 750 nm excitation and the quadratic dependence of this fluorescence emission intensity upon the excitation laser intensity. Since, in general, the penetration depth of ultraviolet and visible light into tissue varies directly with wavelength (red penetrating more deeply than blue), these studies suggest the possibility that two-photon-induced localization of tumor-bound HPD might facilitate the detection of deeper lying tumors than allowed by the current one-photon photolocalization method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏