首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents an innovative portable chip-based RT–PCR system for amplification of specific nucleic acid and detection of RNA-based viruses. The miniature RT–PCR chip is fabricated using MEMS (Micro-electro-mechanical-system) techniques, and comprises a micro temperature control module and a PDMS (polydimethylsiloxane)-based microfluidic control module. The heating and sensing elements of temperature control module are both made of platinum and are located within the reaction chambers in order to generate a rapid and uniform thermal cycling. The microfluidic control module is capable of automating testing process with minimum human intervention. In this paper, the proposed miniature RT–PCR system is used to amplify and detect two RNA-based viruses, namely dengue virus type-2 and enterovirus 71 (EV 71). The experimental data confirm the ability of the system to perform a two-step RT–PCR process. The developed miniature system provides a crucial tool for the diagnosis of RNA-based viruses.  相似文献   

2.
3.
The current study presents a new miniature microfluidic flow cytometer integrated with several functional micro-devices capable of viral sample purification and detection by utilizing a magnetic bead-based immunoassay. The magnetic beads were conjugated with specific antibodies, which can recognize and capture target viruses. Another dye-labeled anti-virus antibody was then used to mark the bead-bound virus for the subsequent optical detection. Several essential components were integrated onto a single chip including a sample incubation module, a micro flow cytometry module and an optical detection module. The sample incubation module consisting of pneumatic micropumps and a membrane-type, active micromixer was used for purifying and enriching the target virus-bound magnetic beads with the aid of a permanent magnet. The micro flow cytometry module and the optical detection module were used to perform the functions of virus counting and collection. Experimental results showed that virus samples with a concentration of 10(3)PFU/ml can be automatically detected successfully by the developed system. In addition, the entire diagnosis procedure including sample incubation and virus detection took only about 40min. Consequently, the proposed micro flow cytometry may provide a powerful platform for rapid diagnosis and future biological applications.  相似文献   

4.
5.
This study reports a microfluidic chip integrated with an arrayed immunoassay for surface plasmon resonance (SPR) phase imaging of specific bio-samples. The SPR phase imaging system uses a surface-sensitive optical technique to detect two-dimensional (2D) spatial phase variation caused by rabbit immunoglobulin G (IgG) adsorbed on an anti-rabbit IgG film. The microfluidic chip was fabricated by using micro-electro-mechanical-systems (MEMS) technology on glass and polydimethylsiloxane (PDMS) substrates to facilitate well-controlled and reproducible sample delivery and detection. Since SPR detection is very sensitive to temperature variation, a micromachine-based temperature control module comprising micro-heaters and temperature sensors was used to maintain a uniform temperature distribution inside the arrayed detection area with a variation of less than 0.3 degrees C. A self-assembled monolayer (SAM) technique was used to pattern the surface chemistry on a gold layer to immobilize anti-rabbit IgG on the modified substrates. The microfluidic chip is capable of transporting a precise amount of IgG solution by using micropumps/valves to the arrayed detection area such that highly sensitive, highly specific bio-sensing can be achieved. The developed microfluidic chips, which employed SPR phase imaging for immunoassay analysis, could successfully detect the interaction of anti-rabbit IgG and IgG. The interactions between immobilized anti-rabbit IgG and IgG with various concentrations have been measured. The detection limit is experimentally found to be 1 x 10(-4)mg/ml (0.67 nM). The specificity of the arrayed immunoassay was also explored. Experimental data show that only the rabbit IgG can be detected and the porcine IgG cannot be adsorbed. The developed microfluidic system is promising for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.  相似文献   

6.
利用GeXP多重基因表达遗传分析系统,建立一种多重逆转录-聚合酶链反应(RT-PCR)方法,同时检测引起手足口病的9种常见的人肠道病毒—人肠道病毒71型(HEV71)、柯萨奇病毒A组(CVA)16、4、5、9、10型和柯萨奇病毒B组(CVB)1、3、5型。优化多重反应体系中针对5’UTR区的肠道病毒通用引物和11对针对9种血清型人肠道病毒VP1区的特异性引物的浓度比例,分别以病毒细胞培养物和阳性粪便标本来验证多重反应体系的特异性,以TCID50定量的细胞培养物和克隆质粒体外转录的RNA梯度稀释液来检测多重检测体系的灵敏度。结果表明,优化后的多重检测体系,可扩增出人肠道病毒共有的保守片段的和型特异性片段,HEV71和CVA16细胞培养物的检测下限为100.5TCID50/μL,并可在103copies/μL水平同时、特异地检测出9种病毒RNA。该方法灵敏度高、特异性强,可快速对大量临床样本进行高通量检测,用于手足口病的分子流行病学调查。  相似文献   

7.
A method and a microfluidic device for automated extraction and purification of nucleic acids from biological samples have been developed. The method involves disruption of bacterial cells and/or viral particles by combining enzymatic and chemical lysis procedures followed by solid-phase sorbent extraction and purification of nucleic acids. The procedure is carried out in an automated mode in a microfluidic module isolated from the outside environment, which minimizes contact of the researcher with potentially infectious samples and, consequently, decreases the risk of laboratory-acquired infections. The module includes reservoirs with lyophilized components for lysis and washing buffers; a microcolumn with a solid-phase sorbent; reservoirs containing water, ethanol, and water-ethanol buffer solutions for dissolving freeze-dried buffer components, rinsing the microcolumn, and eluting of nucleic acids; and microchannels and valves needed for directing fluids inside the module. The microfluidic module is placed into the control unit that delivers pressure, heats, mixes reagents, and flows solutions within the microfluidic module. The microfluidic system performs extraction and purification of nucleic acids with high efficiency in 40 min, and nucleic acids extracted can be directly used in PCR reaction and microarray assays.  相似文献   

8.
Pandemic influenza by the swine-origin influenza virus (H1N1 2009) has attracted considerable concern worldwide. A convenient and accurate diagnostic approach that can be deployed at the point of care, such as in a doctor's office or at an airport, is critical for disease control. Here we report the development of a silicon-based microfluidic system for subtype differentiation of the novel H1N1 2009 strain vs. the seasonal influenza A (FluA) strain. The proposed system included two functional modules: a multiplexed PCR module for amplification of nucleic acid targets and a multiplexed silicon nanowire (SiNW) module for sequence determination. The PCR module consisted of a microfluidic PCR chamber and an electrical controller to perform a multiplexed protocol that simultaneously enriched specific segments of both H1N1 and FluA strains (if present), with 10(4)-10(5) amplification efficiency. The PCR amplicon was subsequently denatured and transferred to the SiNW sensing module for a label-free, multiplexed detection. A control SiNW was implemented, for the first time, in order to eliminate background interference. The detection module demonstrated a 10× change in the magnitude of differential current when the target DNA was injected. Overall, the system achieved a sensitivity of 20-30 fg/μl for H1N1 and seasonal FluA nucleic acids in a 10 μl sample. The low sample consumption, high sensitivity and high specificity render it a potential point-of-care (POC) platform to help doctors reach a yes/no decision for infectious diseases.  相似文献   

9.
Virus identification is a prerequisite not only for the early diagnosis of viral infectious diseases but also for the effective prevention of epidemics. Successful cultivation is the gold standard for identifying a virus, according to the Koch postulates. However, this requires screening for a permissive cell line, which is traditionally time-, reagent- and labor-intensive. Here, a simple and easy-to-operate microfluidic chip, formed by seeding a variety of cell lines and culturing them in parallel, is reported for use in virus cultivation and virus-permissive host-cell screening. The chip was tested by infection with two known viruses, enterovirus 71 (EV71) and influenza virus H1N1. Infection with EV71 and H1N1 caused significant cytopathic effects (CPE) in RD and MDCK cells, respectively, demonstrating that virus cultivation based on this microfluidic cell chip can be used as a substitute for the traditional plate-based culture method and reproduce the typical CPE caused by virus infection. Using this microfluidic cell chip method for virus cultivation could make it possible to identify an emerging virus in a high-throughput, automatic, and unprecedentedly fast way.  相似文献   

10.
11.
The recent, ongoing epidemic of hand, foot, and mouth disease (HFMD), which is caused by enterovirus infection, has affected millions of children and resulted in thousands of deaths in China. Enterovirus 71 (EV71) and coxsackie A16 (CA16) are the two major distinct pathogens for HFMD. However, EV71 is more commonly associated with neurologic complications and even fatalities. Therefore, simultaneously detecting and differentiating EV71 and CA16 specifically from other enteroviruses for diagnosing HFMD is important. Here, we developed a one-step, triplex, real-time RT-PCR assay for the simultaneous detection of EV71, CA16, and pan-enterovirus (EVs) in a single tube with an internal amplification control. The detection results for the serially diluted viruses indicate that the lower limit of detection for this assay is 0.001–0.04 TCID50/ml, 0.02 TCID50/ml, and 0.001 TCID50/ml for EVs, EV71, and CA16, respectively. After evaluating known HFMD virus stocks of 17 strains of 16 different serotypes, this assay showed a favorable detection spectrum and no obvious cross-reactivity. The results for 141 clinical throat swabs from HFMD-suspected patients demonstrated sensitivities of 98.4%, 98.7%, and 100% for EVs, EV71, and CA16, respectively, and 100% specificity for each virus. The application of this one-step, triplex, real-time RT-PCR assay in clinical units will contribute to HFMD surveillance and help to identify causative pathogen in patients with suspected HFMD.  相似文献   

12.
13.
In this study, a viral microarray based assay was developed to detect the human herpesviruses and enteroviruses associated with central nervous system infections, including herpes simplex virus type 1, type 2 (HSV1 and HSV2), Epstein-Barr virus (EBV), cytomegalovirus (CMV), enterovirus 71 (EV71), coxsackievirus A 16 (CA16) and B 5(CB5). The DNA polymerase gene of human herpesviruses and 5’-untranslated region of enteroviruses were selected as the targets to design primers and probes. Human herpesviruses DNA and enteroviruses RNA were extracted simultaneously by using a guanidinium thiocyanate acid buffer, and were subsequently amplified through a biotinylated asymmetry multiplex RT-PCR with the specific primer of enteroviruses. In total, 90 blood samples and 49 cerebrospinal fluids samples with suspected systemic or neurological virus infections were investigated. Out of 139 samples, 66 were identified as positive. The specificities of this multiplex RT-PCR microarray assay were over 96% but the sensitivities were various from 100% for HSV1, HSV2, EV71 and CB5, 95.83% for CMV, 80% for EBV to 71.43% for CA16 in comparison with reference standards of TaqMan qPCR/qRT-PCR. The high Kappa values (>0.90) from HSV1, HSV2, CMV, EV71 and CB5 were obtained, indicating almost perfect agreement in term of the 5 viruses detection. But lower Kappa values for EBV (0.63) and CA16 (0.74) displayed a moderate to substantial agreement. This study provides an innovation of simultaneous extraction, amplification, hybridization and detection of DNA viruses and RNA viruses with simplicity and specificity, and demonstrates a potential clinical utility for a variety of viruses’ detection.  相似文献   

14.
Modern microfabrication and microfluidic technologies offer new opportunities in the design and fabrication of miniaturized cell culture systems for online monitoring of living cells. We used laser micromachining and thermal bonding to fabricate an optically transparent, low-cost polymeric chip for long-term online cell culture observation under controlled conditions. The chip incorporated a microfluidic flow equalization system, assuring uniform perfusion of the cell culture media throughout the cell culture chamber. The integrated indium-tin-oxide heater and miniature temperature probe linked to an electronic feedback system created steady and spatially uniform thermal conditions with minimal interference to the optical transparency of the chip. The fluidic and thermal performance of the chip was verified by finite element modeling and by operation tests under fluctuating ambient temperature conditions. HeLa cells were cultured for up to 2 weeks within the cell culture chip and monitored using a time-lapse video recording microscopy setup. Cell attachment and spreading was observed during the first 10-20 h (lag phase). After approximately 20 h, cell growth gained exponential character with an estimated doubling time of about 32 h, which is identical to the observed doubling time of cells grown in standard cell culture flasks in a CO2 incubator.  相似文献   

15.
This paper reports the development of a one-step SYBR-Green I-based realtime RT-PCR assay for the detection and quantification of Chikungunya virus (CHIKV) in human, monkey and mosquito samples by targeting the E1 structural gene. A preliminary evaluation of this assay has been successfully completed using 71 samples, consisting of a panel of negative control sera, sera from healthy individuals, sera from patients with acute disease from which CHIKV had been isolated, as well as monkey sera and adult mosquito samples obtained during the chikungunya fever outbreak in Malaysia in 2008. The assay was found to be 100-fold more sensitive than the conventional RT-PCR with a detection limit of 4.12x10(0) RNA copies/μl. The specificity of the assay was tested against other related viruses such as Dengue (serotypes 1-4), Japanese encephalitis, Herpes Simplex, Parainfluenza, Sindbis, Ross River, Yellow fever and West Nile viruses. The sensitivity, specificity and efficiency of this assay were 100%, 100% and 96.8% respectively. This study on early diagnostics is of importance to all endemic countries, especially Malaysia, which has been facing increasingly frequent and bigger outbreaks due to this virus since 1999.  相似文献   

16.
17.
This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.  相似文献   

18.
19.
To secure food and water safety, quantitative information on multiple pathogens is important. In this study, we developed a microfluidic quantitative PCR (MFQPCR) system to simultaneously quantify 11 major human viral pathogens, including adenovirus, Aichi virus, astrovirus, enterovirus, human norovirus, rotavirus, sapovirus, and hepatitis A and E viruses. Murine norovirus and mengovirus were also quantified in our MFQPCR system as a sample processing control and an internal amplification control, respectively. River water contaminated with effluents from a wastewater treatment plant in Sapporo, Japan, was collected and used to validate our MFQPCR system for multiple viruses. High-throughput quantitative information was obtained with a quantification limit of 2 copies/μl of cDNA/DNA. Using this MFQPCR system, we could simultaneously quantify multiple viral pathogens in environmental water samples. The viral quantities obtained using MFQPCR were similar to those determined by conventional quantitative PCR. Thus, the MFQPCR system developed in this study can provide direct and quantitative information for viral pathogens, which is essential for risk assessments.  相似文献   

20.
基于RNA的RNA干扰和基因组编辑技术被应用于许多领域.由于其作用的特异性,使RNA成为靶点药物的候选分子.基于RNA的疾病治疗药物的研发近年来有了迅速的发展.随着养殖业的发展,病害引起的损失日益严重.运用小分子RNA药物有效保护水产动物抵抗病毒、寄生虫等的危害的研究也取得了一些成果.综述了RNA干扰和CRISPR的作...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号