首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 297 毫秒
1.
20-Hydroxy-arachidonic acid (20-HETE) was determined in urine by an isotope dilution assay using gas chromatography/mass spectrometry (GC/MS). After addition of 18O2-internal standard, 20-HETE was extracted from urine with hexane either directly or after treatment with glucuronidase. 20-HETE was derivatized to the pentafluorobenzylester and the sample was applied to thin layer chromatography with iso-octane/iso-propanol 9:1 (v/v) as the developing solvent. The corresponding zone was extracted and 20-HETE was hydrogenated. After derivatization to the trimethylsilylether, 20-HETE was determined by GC/MS using the [M-pentafluorobenzyl]- -ion in the negative ion chemical ionization mode. Excretion rates of free and glucuronide conjugated 20-HETE was determined in healthy children and in children with hyperprostaglandin-E-syndrome/antenatal Bartter syndrome (HPS/aBS) with or without indomethacin treatment. Compared to the controls, the HPS/aBS children showed higher excretion rates of 20-HETE, which were suppressed to normal values under indomethacin medication. Free and glucuronide conjugated 20-HETE do not correlate with PGE2 excluding any participation in HPS/aBS.  相似文献   

2.
An in-situ supercritical fluid extraction (SFE) and chemical derivatization (ChD) procedure followed by gas chromatography–isotope dilution mass spectrometry (GC–MS) for the determination of amphetamines in urine is described and evaluated. While using celite as the SFE wet-support, the one-pot sample pretreatment procedure also employs ammonium water to alkalize the urine matrix that contains protonated amphetamine (AP) and methamphetamine (MA). The mean recoveries achieved by simultaneous SFE–ChD, i.e., 95% (RSD=3.8%) for AP and 89% (RSD=4.0%) for MA, are significantly better than the corresponding overall recoveries obtained upon stepwise SFE–ChD, suggesting the unreacted trifluoroacetic anhydride (TFA) in the former procedure has strengthened the extracting power of CO2 fluid as has been evidenced by a control test. As to GC–MS analysis, the optimal qualitative ions and quantitative ions of the respective analytes were determined via a rigorous evaluation process. Thus, the regression calibration curves for AP and MA in urine are linear within 100∼50 000 ng/ml, with correlation coefficients typically exceeding 0.999. The limits of detection determined by two methods for AP and MA vary from 19 to 50 ng/ml, and limits of quantitation from 21 to 100 ng/ml. Precisions calculated for the triplicate analyses of AP and MA in a 500-ng/ml spiked control, two real-case samples and two quasi real-case samples, respectively, using regression calibration are typically below 10%. The method is simple and reliable. It may serve as an alternative to the existing confirmatory protocol for forensic urine drug testing.  相似文献   

3.
This study describes a fluorescent HPLC assay for measuring 20-hydroxyeicosatetraenoic acid (20-HETE) and other cytochrome P-450 metabolites of arachidonic acid in urine, tissue, and interstitial fluid. An internal standard, 20-hydroxyeicosa-6(Z),15(Z)-dienoic acid, was added to samples, and the lipids were extracted and labeled with 2-(2,3-naphthalimino)ethyl trifluoromethanesulfonate. P-450 metabolites were separated on a C18 reverse-phase HPLC column. Coelution and gas chromatography-mass spectrometry studies confirmed the identity of the 20-HETE peak. The 20-HETE peak can be separated from those for dihydroxyeicosatrienoic acids, other HETEs, and epoxyeicosatrienoic acids. Known amounts of 20-HETE were used to generate a standard curve (range 1-10 ng, r(2) = 0.98). Recovery of 20-HETE from urine averaged 95%, and the intra-assay variation was <5%. Levels of 20-HETE were measured in 100 microliter of urine and renal interstitial fluid or 0.1 mg of renal tissue. The assay was evaluated by studying the effects of 1-aminobenzotriazole (ABT) on the excretion of 20-HETE in rats. ABT reduced excretion of 20-HETE by >65% and inhibited the formation of 20-HETE by renal microsomes. The availability of this assay should facilitate work in this field.  相似文献   

4.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

5.
An improved method for the determination of ethyl glucuronide (EtG) in human serum and urine was developed using solid-phase extraction (SPE) and gas chromatography (GC) with mass spectrometric detection (MS). EtG was isolated from serum and urine using aminopropyl SPE columns after deproteination with perchloric acid and hydrochloric acid, respectively. The chromatographic separation was performed on a DB 1701 fused-silica column. At a signal-to-noise ratio of 3:1, a quantification limit of 173 and 560 ng/ml and a detection limit of 37 and 168 ng/ml could be determined for serum and urine, respectively. This indicates high specificity and sensitivity of the described method. The mean absolute recovery was 85%, while intra- and inter-day precision of the assay were all less than 7.5%. The linearity of the calibration curves was satisfying as indicated by correlation coefficients of >0.993. The presented method provides the basis for determination and identification of EtG in human serum and urine samples in a low-concentration range for monitoring alcohol consumption during treatment for alcohol dependence and comorbid alcohol abuse of psychotherapy patients.  相似文献   

6.
We describe a rapid GC/MS assay for amphetamine-type stimulant drugs (ATSs) and structurally related common medicaments in blood, serum, oral fluid and urine samples. The drugs were extracted from their matrices and derivatized with heptafluorobutyric anhydride (HFBA) in a single step, using the following procedure: 100 microl (oral fluid) or 200 microl (blood, serum, urine) of the sample were mixed with 50 microl of alkaline buffer and 500 microl of extraction-derivatization reagent (toluene + HFBA + internal standard), centrifuged, and injected into a GC/MS apparatus. As revealed by the validation data this procedure, with its limit of quantitation being set at 20 ng/ml for oral fluid, 25 ng/ml for blood or 200 ng/ml for urine, is suitable for screening, identification and quantitative determination of the ATSs and related drugs in all the matrices examined. Thus, time-consuming and expensive multiple analyses are not needed, unless specifically required.  相似文献   

7.
In the present study, we simultaneously measured several polyols, such as adonitol, arabitol, dulcitol, glucose, myo-inositol, mannitol, sorbitol, and xylitol, in urine by gas chromatography/mass spectrometry-positive chemical ionization. We also examined possible relationship between the levels of these metabolites and age in normal individuals. In order to proceed to its quantification by GC/MS, 200 microL of a urine sample were diluted with 3 ml of distilled water, lyophilized, acetylated, and then analyzed them. Using this method, we were able to quantify as little as 0.5-1.0 ng/microL, and we made the calibration curves to be linear from 0.25 to 250 ng/microL (r(2)>0.991). Analytical recoveries were over 89.4%, and the inter-day and intra-day variability for accuracy and reproducibility was less than 20%. In the normal urine sample, the levels of polyols were gender-differentiated and age-related. This simple GC/MS method is sensitive and allows the measurement of wide ranges of polyols using small amounts of urine. We conclude that the quantitation of urinary polyols using GC/MS appears to be a clinically useful method for assessing polyol-pathway activity.  相似文献   

8.
The analysis of arildone in plasma, urine and feces by gas—liquid chromatography with electron-capture detection is described. O-(2,3,4,5,6-Pentafluorohenzyl)hydroxylamine is the derivatizing agent for the plasma and urine analysis; 3-nitrophenylhydrazine is utilized for fecal analysis. The mean (± S.E.) minimum quantifiable level of arildone was 1.4 (± 0.2) ng/ml in urine, 6.4 (± 0.1) ng/ml in plasma, and 12.6 (± 1.0) ng/g in feces. The chromatographic response was linear in the range of 0 and 10–120 ng/ml for plasma, 0 and 2.5–20 ng/ml for urine and 0 and 25–250 ng/g for feces. The estimated overall precision of the assay was 5.5%, 6.4% and 8.9% in urine, plasma and feces, respectively.  相似文献   

9.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

10.
Sensitive methods based on capillary gas chromatography (GC) with mass spectrometric (MS) detection in a selected-ion monitoring mode (SIM) for the determination of a cyclooxygenase II (COX-II) inhibitor (3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one, I) in human plasma, in two concentration ranges of 0.1-20 and 5-1000 ng/ml, are described. Following liquid-liquid extraction, the residue, after evaporation of the organic phase to dryness, was reconstituted in acetonitrile (20 l) and part of the extract (1 l) was analyzed by GC/MS/SIM. The drug (I) and internal standard (II) were separated on a 25 mx0.2 mm capillary column with HP Ultra 1 (100% dimethylpolysiloxane, 0.33 m) phase and analyzed by MS/SIM monitoring ions at m/z 237 and 282 for I and II, respectively. The standard curve was linear within the lower concentration range of 0.1-20 ng/ml and the lower limit of quantification (LLOQ) in plasma was 0.1 ng/ml. Intraday coefficients of variation (CV, n=5) were 8.9, 4.2, 5.7, 3.1, 1.9, 1.9, and 4.4% at 0.1, 0.2, 0.5, 1.0, 5.0, 10, and 20 ng/ml, respectively. The standard curve was also linear within the higher concentration range of 5-1000 ng/ml and the LLOQ in plasma was 5 ng/ml. Intraday coefficients of variation (CV, n=5) were all below 9% at all concentrations within the standard curve range. The accuracy for I in human plasma was 91-112% and the recovery of I and II was greater than 70% at all concentrations within both standard curve ranges. The details of the assay methodology are presented.  相似文献   

11.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

12.
A sensitive and specific high-performance liquid chromatographic–tandem mass spectrometric (HPLC–MS–MS) method was developed for the determination of 3-hydroxypropylmercapturic acid (3-HPMA) in human urine. Samples were extracted using ENV+ cartridges and then injected onto a C8 Superspher Select B column with acetonitrile and formic acid as eluent (5:95, v/v). N-Acetylcysteine was used as internal standard for HPLC–MS–MS. Linearity was given in the tested range of 50–5000 ng/ml urine. The limit of quantification was 50 ng/ml. Precision, as C.V., in the tested range of 50–5000 ng/ml was 1.47–6.04%. Accuracy ranged from 87 to 114%. 3-HPMA was stable in human urine at 37°C for 24 h. The method was able to quantify 3-HPMA in urine of non-smokers and smokers.  相似文献   

13.
I Yokoi  Y Watanabe  A Edaki  A Mori 《Life sciences》1987,41(10):1305-1309
delta-Guanidinovaleric acid (DGVA) was identified in human urine using thin layer chromatography (TLC), high performance liquid chromatography (HPLC) and gas chromatography/mass spectrometry (GC/MS). In the TLC, all Rfs of sample from urine developed by 6 solvent systems were identical to that of authentic DGVA. In the GC/MS, the mass spectrum of the sample was identical to the trifluoroacetylated dimethylpyrimidyl derivative of DGVA butylester (M+ = 375). In the HPLC analysis, the DGVA peak was observed just before 15 min in either chromatogram obtained by analysis of human urine or authentic DGVA, and the content of DGVA in pooled human urine was calculated at 2.4 nmol/ml.  相似文献   

14.
Our interests are in the development of immunoassay-based fast scanning methods for persistent organic pollutants. To develop the immunoassay method of polybrominated diphenyl ether (PBDE), a model compound of PBDE, 2,3′,4,5′,6-pentabromodiphenylether (BDE-121), has been chosen to develop its antibody and the competitive indirect enzyme-linked immunosorbent assay (ELISA) is developed. The hapten of BDE-121 containing reactive carboxylic acid was synthesized and conjugated to carrier proteins (bovine serum albumin [BSA] and ovalbumin [OVA]). Anti-BDE-121 polyclonal antibody was then developed in rabbits as a result of immunization with the BDE-121–BSA conjugate. The optimal amount of coating antigen BDE-121–OVA conjugate and the dilution of antiserum needed in the ELISA were determined with the checkerboard method, and the effects of the properties of PBST (phosphate-buffered saline and Tween 20) buffer (pH and salt concentration) and chemical solvent (types and concentrations) on the ELISA were investigated to achieve a rapid robust assay with high sensitivity. Under the optimized conditions, the developed indirect ELISA shows a linear detection range from 1.74 to 84.1 ng/ml, with an IC50 value of 8.07 ng/ml and a detection limit of 0.644 ng/ml. In total, 11 kinds of compounds were tested for calculating the cross-reactivity, which was less than 8% for nearly all of them. Real samples were analyzed by the proposed immunoassay and gas chromatography/mass spectrometry (GC/MS).  相似文献   

15.
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.  相似文献   

16.
A simple determination method of amphetamine (AP) and methamphetamine (MA) in biological materials was developed using on-column derivatization and gas chromatography-mass spectrometry (GC-MS). AP and MA in biological materials were adsorbed on the surface of Extrelut and then extracted and derivatized simultaneously on the Extrelut column. AP and MA were derivatized to the N-propoxycarbonyl derivatives using propylchloroformate. Pentadeuterated MA was used as an internal standard. The recoveries of AP and MA from urine were 88.2 and 92.5%, and those from blood were 89.7 and 90.3%, respectively. The calibration curves showed linearity in the range of 12.5-2000 ng/ml (ng/g) for AP and MA in urine and blood, and 0.25-20 ng/mg in hair. When urine samples containing two different concentrations (200 and 1000 ng/ml) of AP and MA, blood samples containing two different concentrations (200 and 1000 ng/g) of AP and MA, hair samples containing two different concentrations (0.5 and 5.0 ng/mg) of AP and MA, the coefficients of variation of intra-day and inter-day were 0.68-3.60% in urine, 0.42-4.58% in blood, and 1.20-13.1% in hair. Furthermore, this proposed method was applied to a medico-legal case of MA intoxication.  相似文献   

17.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

18.
We have presented a simple and sensitive method for determining pethidine, a narcotic analgesic drug in body fluids by gas chromatography (GC)/surface ionization organic mass spectrometry (SIOMS). Good linearity was obtained in the range of 0.625–25 ng/ml of whole blood and urine by mass chromatography, and in the range of 0.05–2 ng/ml of whole blood by selected ion monitoring (SIM). Pethidine and diphenylpyraline (internal standard) were extracted from body fluids with Bond Elut Certify cartridges; their recoveries were above 95%. The detection limits (signal-to-noise ratio=3) were estimated to be 0.2 ng/ml of whole blood or urine by mass chromatography, 0.02 ng/ml of whole blood by SIM.  相似文献   

19.
Mono-hydroxy-eicosatetraenoic acids (HETE's) are frequently the principal lipoxygenase-derived products in a number of cell types. This paper describes the development of a selective and sensitive radioimmunoassay procedure for 15-HETE, a metabolite which has previously been shown to be both an activator and inhibitor of leukotriene formation in various cells. Initially, rabbits were immunized with 15-HETE conjugated to bovine serum albumin. After seven months, the anti-plasma showed significant binding of tritiated 15-HETE (40-45% binding with a 1:600 dilution of the anti-plasma) which was displaceable by cold 15-HETE. The sensitivity of the assay was approximately 20 pg. of 15-HETE. The anti-plasma exhibited very little (less than 1%) cross-reactivity with arachidonic acid, 5-, 8-, 9-, 11- and 12-HETE's, HHT, TXB2, PGE2 and 6-Keto-PGF1 alpha. Significant cross-reactivity was observed with 5,15-diHETE (53%), 8, 15-diHETE (6.6%), and several other 15-hydroxy-eicosanoids. Rabbit reticulocytes have a very active 15S-lipoxygenase and converted arachidonic acid (final concentration 7 microM) principally to 15-HETE. Unstimulated reticulocytes were found to release negligible amounts of 15-HETE as determined by radioimmunoassay. Treatment of these cells with the calcium ionophore A23187 (0.16 to 4.0 micrograms/ml) elicited a level of 15-HETE release (8 - 14 ng/ml) that was twenty to forty times less than that obtained with exogenous arachidonic acid (2.5 micrograms/ml). The radioimmunoassay reported here may be useful for identifying factors which stimulate cellular release of 15-HETE and other 15-hydroxy-eicosanoids from endogenous arachidonic acid.  相似文献   

20.
A gas chromatographic–mass spectrometric (GC–MS) assay was developed for the quantitative analysis of methyl salicylate (MeS), ethyl salicylate (ES) and salicylic acid (SA) from biological fluids. The method was validated from 100-μl rat liver homogenate preparations (5 mg/ml protein) in 70 mM KH2PO4 (pH 7.4) buffer and from 100 μl rat plasma. The samples were extracted with chloroform, derivatized with BSTFA and quantitated by GC–MS in the SIM mode. The standard curves ranged from 31 ng/ml to 800 or 1250 ng/ml. Relative standard deviations and bias were less than 11% in plasma and homogenate for all compounds except SA which evidenced greater variability. The assay was used in preliminary experiments to characterize the pharmacokinetics of MeS in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号