1.
Responses to exchange transfusion with red blood cells (RBCs) containing methemoglobin (MetRBC) were studied in an acute isovolemic hemodiluted hamster window chamber model to determine whether oxygen content participates in the regulation of systemic and microvascular conditions during extreme hemodilution. Two isovolemic hemodilution steps were performed with 6% dextran 70 kDa (Dex70) until systemic hematocrit (Hct) was reduced to 18% (Level 2). A third-step hemodilution reduced the functional Hct to 75% of baseline by using either a plasma expander (Dex70) or blood adjusted to 18% Hct with all MetRBCs. In vivo functional capillary density (FCD), microvascular perfusion, and oxygen distribution in microvascular networks were measured by noninvasive methods. Methylene blue was administered intravenously to reduce methemoglobin (rRBC), which increased oxygen content with no change in Hct or viscosity from MetRBC. Final blood viscosities after the entire protocol were 2.1 cP for Dex70 and 2.8 cP for MetRBC (baseline, 4.2 cP). MetRBC had a greater mean arterial pressure (MAP) than did Dex70. FCD was substantially higher for MetRBC [82 (SD 6) of baseline] versus Dex70 [38 (SD 10) of baseline], and reduction of methemoglobin to oxyhemoglobin did not change FCD [84% (SD 5) of baseline]. P(O2) levels measured with palladium-meso-tetra(4-carboxyphenyl)porphyrin phosphorescence were significantly changed for Dex70 and MetRBC compared with Level 2 (Hct 18%). Reduction of methemoglobin to oxyhemoglobin partially restored P(O2) to Level 2. Wall shear rate and wall shear stress decreased in arterioles and venules for Dex70 and did not change for MetRBC or rRBC. Increased MAP and shear stress-mediated factors could be the possible mechanisms that improved perfusion flow and FCD after exchange for MetRBC. Thus the fall in systemic and microvascular conditions during extreme hemodilution with low-viscosity plasma expanders seems to be, in part, from the decrease in blood viscosity independent of the reduction in oxygen content.  相似文献   

2.
Responses to exchange transfusion using red blood cells (RBCs) with normal and reduced flexibility were studied in the hamster window chamber model during acute moderate isovolemic hemodilution to determine the role of RBC membrane stiffness in microvascular perfusion and tissue oxygenation. Erythrocyte stiffness was increased by 30-min incubation in 0.02% glutaraldehyde solution, and unreacted glutaraldehyde was completely removed. Filtration pressure through 5-microm pore size filters was used to quantify stiffness of the RBCs. Anemic conditions were induced by two isovolemic hemodilution steps using 6% 70-kDa dextran to a hematocrit (Hct) of 18% (moderate hemodilution). The protocol continued with an exchange transfusion to reduce native RBCs to 75% of baseline (11% Hct) with either fresh RBCs (RBC group) or reduced-flexibility RBCs (GRBC group) suspended in 5% albumin at 18% Hct; a plasma expander (6% 70-kDa dextran; Dex70 group) was used as control. Systemic parameters, microvascular perfusion, capillary perfusion [functional capillary density (FCD)], and oxygen levels across the microvascular network were measured by noninvasive methods. RBC deformability for GRBCs was significantly decreased compared with RBCs and moderate hemodilution conditions. The GRBC group had a greater mean arterial blood pressure (MAP) than the RBC and Dex70 groups. FCD was substantially higher for RBC (0.81 +/- 0.07 of baseline) vs. GRBC (0.32 +/- 0.10 of baseline) and Dex70 (0.38 +/- 0.10 of baseline) groups. Microvascular tissue Po(2) was significantly lower for Dex70 and GRBC vs. RBC groups and the moderate hemodilution condition. Results were attributed to decreased oxygen uploading in the lungs and obstruction of tissue capillaries by rigidified RBCs, indicating that the effects impairing RBC flexibility are magnified at the microvascular level, where perfusion and oxygenation may define transfusion outcome.  相似文献   

3.
Chatpun S  Cabrales P 《Biorheology》2010,47(3-4):225-237
The purpose of this study was to investigate how plasma viscosity affects cardiac and vascular function during moderate hemodilution. Twelve anesthetized hamsters were hemodiluted by 40% of blood volume with two different viscosity plasma expanders. Experimental groups were based on the plasma expander viscosity, namely: high viscosity plasma expander (HVPE, 6.3 mPa?·?s) and low viscosity plasma expander (LVPE, 2.2 mPa?·?s). Left ventricular (LV) function was intracardiacally measured with a high temporal resolution miniaturized conductance catheter and concurrent pressure-volume results were used to calculate different LV indices. Independently of the plasma expander, hemodilution decreased hematocrit to 28% in both groups. LVPE hemodilution reduced whole blood viscosity by 40% without changing plasma viscosity, while HVPE hemodilution reduced whole blood viscosity by 23% and almost doubled plasma viscosity relative to baseline. High viscosity plasma expander hemodilution significantly increased cardiac output, stroke volume and stroke work compared to baseline, whereas LVPE hemodilution did not. Furthermore, an increase in plasma viscosity during moderate hemodilution produced a higher energy transfer per unit volume of ejected blood. Systemic vascular resistance decreased after hemodilution in both groups. Counter-intuitively, HVPE hemodilution showed lower vascular resistance and vascular hindrance than LVPE hemodilution. This result suggests that geometrical changes in the circulatory system are induced by the increase in plasma viscosity. In conclusion, an increase in plasma viscosity after moderate hemodilution directly influenced cardiac and vascular function by maintaining hydraulic power and reducing systemic vascular resistance through vasodilation.  相似文献   

4.
O2-carrying fluids based on hemoglobin (Hb) are in various stages of clinical trials to determine their suitability as O2-carrying plasma expanders. Polymerized Hb solutions are characterized by their vasoactivity, low O2 affinity, oncotic effect, prolonged shelf life, and stability. Physiological responses to facilitated O2 transport after exchange transfusion with polymerized bovine Hb (PBH) were studied in the hamster window chamber model during acute moderate anemia to determine how PBH affects microvascular perfusion and tissue oxygenation. The anemic state [29% hematocrit (Hct)] was induced by hemodilution with a plasma expander (70 kDa dextran). After hemodilution, animals were randomly assigned to different exchange transfusion groups. Study groups were based on the concentration of PBH used, namely: PBH at 13 g Hb/dl [PBH13], PBH diluted to 8 (PBH8) or 4 (PBH4) g Hb/dl in albumin solution at matching colloidal osmotic pressure (COP), and no PBH (only albumin solution) at matching COP (PBH0). Measurement of systemic parameters, microvascular hemodynamics, capillary perfusion, and intravascular and tissue O2 levels was performed at 18% Hct. Restitution of O2-carrying capacity with PBH13 increased arterial pressure and triggered vasoconstriction, low perfusion, and high peripheral resistance. PBH4 and PBH0 exhibited lower arterial pressures compared with PBH13. Exchange transfused animals with PBH8 and PBH4 better maintained perfusion and functional capillary density than PBH13. Blood gas parameters and acid-base balance were recovered proportional to microvascular perfusion. Arterial O2 tensions were improved with PBH4 and PBH8 by preventing O2 precapillary release and increasing O2 reserve. Further studies to establish PBH optimal dosage, efficacy, safety, and its effect on outcome are indicated before Hb-based O2-carrying blood substitutes are implemented in routine practice.  相似文献   

5.
Isovolemic hemodilution to 11% systemic hematocrit was performed in the hamster window chamber model using 6% dextran 70 kDa (Dx 70) and 5% human serum albumin (HSA). Systemic and microvascular effects of these solutions were compared with polyethylene glycol (PEG)-conjugated 5% albumin (MPA) and PEG-conjugated 4.2% Hb (MP4). These studies were performed for the purpose of comparing systemic and microvascular responses of PEG vs. non-PEG plasma expanders and similar oxygen-carrying vs. noncarrying blood replacement fluids. Mean arterial blood pressure was statistically significantly reduced for all groups compared with baseline (P < 0.05), HSA, MPA, and MP4 higher than Dx 70 (P < 0.05). MP4 and MPA had a significantly higher cardiac index than HSA and Dx 70, in addition to a positive base excess. Microvascular blood flow and capillary perfusion were significantly higher for the PEG compounds compared with HSA and Dx 70. Intravascular PO2 for MP4 and MPA was higher in arterioles (P < 0.05) compared with HSA and Dx 70, but there was no difference in either tissue or venular PO2 between groups. Total Hb in the MP4 group was 4.8 +/- 0.4 g/dl, whereas the remaining groups had a range of 3.6-3.8 g/dl. The hemodilution results showed that PEG compounds maintained microvascular conditions with lower concentrations than conventional plasma expanders. Furthermore, microvascular oxygen delivery and extraction in the window chamber tissue were significantly higher for the PEG compounds. MP4 was significantly higher than MPA (P < 0.05) and was not statistically different from baseline, an effect due to the additional oxygen release to the tissue by the Hb MP4.  相似文献   

6.
The oxygen transport capacity of fluorocarbons was investigated in the hamster chamber window model microcirculation to determine the rate at which oxygen is delivered to the tissue in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Hydroxyethlyl starch (HES 200; 200 kDa molecular mass) was used as a plasma expander for two isovolemic hemodilutions performed with 10% HES 200 until a Hct of 65%. A third step reduced the Hct to 75% of baseline and was performed with either HES 200 or a 60% perfluorocarbon (PFC) emulsion. Comparisons of HES 200-only-hemodiluted animals versus 4.2 g/kg PFC emulsion-hemodiluted animals were made at 21% and 100% normobaric oxygen ventilation. It was found that systemic and microvascular oxygen delivery was 25% and 400% higher in the PFC animals compared with HES 200 animals, respectively, showing that PFCs deliver oxygen to the tissue when combined with hyperoxic ventilation in the present experiments, with no evidence of vasoconstriction or impaired microvascular function. Oxygen ventilation (100%) led to a positive base excess for the PFC group (5.5 +/- 2.5 mmol/l) versus a negative balance (-0.8 +/- 1.4 mmol/l) for the HES 200 group, suggesting that microvascular findings corresponded to systemic events.  相似文献   

7.
The oxygen transport capacity of phospholipid vesicles encapsulating purified Hb (HbV) produced with a Po(2) at which Hb is 50% saturated (P 50 ) of 8 (HbV(8)) and 29 mmHg (HbV(29)) was investigated in the hamster chamber window model by using microvascular measurements to determine oxygen delivery during extreme hemodilution. Two isovolemic hemodilution steps were performed with 5% recombinant albumin (rHSA) until Hct was 35% of baseline. Isovolemic exchange was continued using HbV suspended in rHSA solution to a total [Hb] of 5.7 g/dl in blood. P(50) was modified by coencapsulating pyridoxal 5'-phosphate. Final Hct was 11% for the HbV groups, with a plasma [Hb] of 2.1 +/- 0.1 g/dl after exchange with HbV(8) or HbV(29). A reference group was hemodiluted to Hct 11% with only rHSA. All groups showed stable blood pressure and heart rate. Arterial oxygen tensions were significantly higher than baseline for the HbV groups and the rHSA group and significantly lower for the HbV groups compared with the rHSA group. Blood pressure was significantly higher for the HbV(8) group compared with the HbV(29) group. Arteriolar and venular blood flows were significantly higher than baseline for the HbV groups. Microvascular oxygen delivery and extraction were similar for the HbV groups but lower for the rHSA group (P < 0.05). Venular and tissue Po(2) were statistically higher for the HbV(8) vs. the HbV(29) and rHSA groups (P < 0.05). Improved tissue Po(2) is obtained when red blood cells deliver oxygen in combination with a high- rather than low-affinity oxygen carrier.  相似文献   

8.
Systemic parameters and microvascular and capillary hemodynamics were studied in the hamster window chamber model before and after hyaluronan degradation by intravenous injection of Streptomyces hyaluronidase (100 units, 40-50 U/ml plasma). Glycocalyx permeation was estimated using fluorescent markers of different molecular size (40, 70, and 2,000 kDa), and electrical charge. Systemic parameters (blood pressure, heart rate, blood gases) and microhemodynamics (vascular tone, velocity, and blood flow) remained statistically unchanged after injection of hyaluronidase, compared with inactivated hyaluronidase. Conversely, capillary hemodynamics were drastically affected. Functional capillary density, the capillaries perfused with red blood cells (RBCs), decreased by 35%, capillary Hct of the remaining functional capillaries increased from 16 to 27%, and penetration of 70-kDa fluorescent marker increased. Furthermore, plasma-only perfused capillaries statistically increased 30 min after hyaluronidase. The decrease in functional capillary density accounted for an increased RBC flux in the remainder of the capillaries, since the same number of RBCs had to traverse a reduced number of capillaries. Flux balances showed a reduction from baseline of 11% for the RBC flux and 20% for the plasma flux after treatment. These discrepancies are within the margin of error of the techniques used and could be explained by accounting for RBC over-velocity compared with plasma. These findings suggest that the decrease in the glycocalyx leads to capillary perfusion impairments.  相似文献   

9.
We tested the hypothesis that high-viscosity (HV) plasma in extreme hemodilution causes wall shear stress to be greater than low-viscosity (LV) plasma, leading to enhanced production of nitric oxide (NO). The perivascular concentration of NO was measured in arterioles and venules and the tissue of the hamster chamber window model, subjected to acute extreme hemodilution, with a hematocrit (Hct) of 11% using Dextran 500 (n = 6) or Dextran 70 (n = 5) with final plasma viscosities of 1.99 +/- 0.11 and 1.33 +/- 0.04 cp, respectively. HV plasma significantly increased the periarteriolar, perivenular, and tissue NO concentration by 2.0, 1.9, and 1.4 times the control (n = 7). The NO concentration with LV plasma was not statistically different from control. Arteriolar shear stress was significantly increased in HV plasma relative to LV plasma in arterioles but not in venules. Aortic endothelial NO synthase (eNOS) protein expression was increased with HV plasma but not with LV plasma. There was a weak correlation between perivascular NO concentration and the locally calculated shear stress induced by the procedures, when blood viscosity was corrected according to Hct values previously determined in studies of microvascular Hct distribution. The finding that the periarteriolar and venular NO concentration in HV plasma was the same although arteriolar shear stress was significantly greater than venular shear stress maybe be due to differences in vessel wall metabolism between arterioles and venules and the presence of NO transport through the blood stream in the microcirculation. Results support the concept that in extreme hemodilution HV plasma maintains functional capillary density through a NO-mediated vasodilatation.  相似文献   

10.
Blood losses are usually corrected initially by the restitution of volume with plasma expanders and subsequently by the restoration of oxygen-carrying capacity using either a blood transfusion or possibly, in the near future, oxygen-carrying plasma expanders. The present study was carried out to test the hypothesis that high-plasma viscosity hemodilution maintains perfused functional capillary density (FCD) by preserving capillary pressure. Microvascular pressure responses to extreme hemodilution with low- (LV) and high-viscosity (HV) plasma expanders and an exchange transfusion with a polymerized bovine cell-free Hb (PBH) solution were analyzed in the awake hamster window chamber model (n = 26). Systemic hematocrit was reduced from 50% to 11%. PBH produced a greater mean arterial blood pressure than the nonoxygen carriers. FCD was higher after a HV plasma expander (70 +/- 15%) vs. PBH (47 +/- 12%). Microvascular pressure spanning the capillary network was higher after a HV plasma expander (16-19 mmHg) compared with PBH (12-16 mmHg) and a LV plasma expander (11-14 mmHg) but lower than control (22-26 mmHg). FCD was found to be directly proportional to capillary pressure. The use of a HV plasma expander in extreme hemodilution maintained the number of perfused capillaries and tissue perfusion by comparison with a LV plasma expander due to increased mean arterial blood pressure and capillary pressure. The use of PBH increased mean arterial pressure but reduced capillary pressure due to vasoconstriction and did not maintain FCD.  相似文献   

11.
The oxygen transport capacity of nonhypertensive polyethylene glycol (PEG)-conjugated hemoglobin solutions were investigated in the hamster chamber window model. Microvascular measurements were made to determine oxygen delivery in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Two isovolemic hemodilution steps were performed with a 6% Dextran 70 (70-kDa molecular mass) plasma expander until Hct was 35% of control. Isovolemic blood volume exchange was continued using two surface-modified PEGylated hemoglobins (P5K2, P(50) = 8.6, and P10K2, P(50) = 8.3; P(50) is the hemoglobin Po(2) corresponding to its 50% oxygen saturation) until Hct was 11%. P5K2 and P10K2 are PEG-conjugated hemoglobins that maintain most of the hemoglobin allosteric properties and have a cooperativity index of n = 2.2. The effects of these molecular solutions were compared with those obtained in a previous study using MP4, a PEG-modified hemoglobin whose P(50) was 5.4 and cooperativity was 1.2 (Tsai et al., Am J Physiol Heart Circ Physiol 285: H1411-H1419, 2003). Tissue oxygen levels were higher after P5K2 (7.0 +/- 2.5 mmHg) and P10K2 (6.3 +/- 2.3 mmHg) versus MP4 (1.7 +/- 0.5 mmHg) or the nonoxygen carrier Dextran 70 (1.3 +/- 1.2 mmHg). Microvascular oxygen delivery was higher after P5K2 and P10K2 (2.22 and 2.34 ml O(2)/dl blood) compared with MP4 (1.41 ml O(2)/dl blood) or Dextran 70 (0.90 ml O(2)/dl blood); however, all these values were lower than control (7.42 ml O(2)/dl blood). The total hemoglobin in blood was similar in all cases; therefore, the improvement in tissue Po(2) and oxygen delivery appears to be due to the increased cooperativity of the new molecules.  相似文献   

12.
Hematocrit (Hct) of awake hamsters and CD-1 mice was acutely increased by isovolemic exchange transfusion of packed red blood cells (RBCs) to assess the relation between Hct and blood pressure. Increasing Hct 7-13% of baseline decreased mean arterial blood pressure (MAP) by 13 mmHg. Increasing Hct above 19% reversed this trend and caused MAP to rise above baseline. This relationship is described by a parabolic function (R2 = 0.57 and P < 0.05). Hamsters pretreated with the nitric oxide (NO) synthase (NOS) inhibitor N(omega)-nitro-L-arginine methyl ester (L-NAME) and endothelial NOS-deficient mice showed no change in MAP when Hct was increased by <19%. Nitrate/nitrite plasma levels of Hct-augmented hamsters increased relative to control and L-NAME treated animals. The blood pressure effect was stable 2 h after exchange transfusion. These findings suggest that increasing Hct increases blood viscosity, shear stress, and NO production, leading to vasodilation and mild hypotension. This was corroborated by measuring A1 arteriolar diameters (55.0 +/- 21.5 microm) and blood flow in the hamster window chamber preparation, which showed statistically significant increased vessel diameter (1.04 +/- 0.1 relative to baseline) and microcirculatory blood flow (1.39 +/- 0.68 relative to baseline) after exchange transfusion with packed RBCs. Larger increases of Hct (>19% of baseline) led blood viscosity to increase >50%, overwhelming the NO effect through a significant viscosity-dependent increase in vascular resistance, causing MAP to rise above baseline values.  相似文献   

13.
Mathematical simulations of oxygen delivery to tissue from capillaries that take into account the particulate nature of blood flow predict the existence of oxygen tension (Po(2)) gradients between erythrocytes (RBCs). As RBCs and plasma alternately pass an observation point, these gradients are manifested as rapid fluctuations in Po(2), also known as erythrocyte-associated transients (EATs). The impact of hemodilution on EATs and oxygen delivery at the capillary level of the microcirculation has yet to be elucidated. Therefore, in the present study, phosphorescence quenching microscopy was used to measure EATs and Po(2) in capillaries of the rat spinotrapezius muscle at the following systemic hematocrits (Hct(sys)): normal (39%) and after moderate (HES1; 27%) or severe (HES2; 15%) isovolemic hemodilution using a 6% hetastarch solution. A 532-nm laser, generating 10-micros pulses concentrated onto a 0.9-microm spot, was used to obtain plasma Po(2) values 100 times/s at points along surface capillaries of the muscle. Mean capillary Po(2) (Pc(O(2)); means +/- SE) significantly decreased between conditions (normal: 56 +/- 2 mmHg, n = 45; HES1: 47 +/- 2 mmHg, n = 62; HES2: 27 +/- 2 mmHg, n = 52, where n = capillary number). In addition, the magnitude of Po(2) transients (DeltaPo(2)) significantly decreased with hemodilution (normal: 19 +/- 1 mmHg, n = 45; HES1: 11 +/- 1 mmHg, n = 62; HES2: 6 +/- 1 mmHg, n = 52). Results suggest that the decrease in Pc(O(2)) and DeltaPo(2) with hemodilution is primarily dependent on Hct(sys) and subsequent microvascular compensations.  相似文献   

14.
We studied the extreme hemodilution to a hematocrit of 11% induced by three plasma expanders: polyethylene glycol (PEG)-conjugated albumin (PEG-Alb), 6% 70-kDa dextran, and 6% 500-kDa dextran. The experimental component of our study relied on microelectrodes and cardiac output to measure both the rheological properties of plasma-expander blood mixtures and nitric oxide (NO) bioavailability in vessel walls. The modeling component consisted of an analysis of the distribution of wall shear stress (WSS) in the microvessels. Our experiments demonstrated that plasma expansion with PEG-Alb caused a state of supraperfusion with cardiac output 40% above baseline, significantly increased NO vessel wall bioavailability, and lowered peripheral vascular resistance. We attributed this behavior to the shear thinning nature of blood and PEG-Alb mixtures. To substantiate this hypothesis, we developed a mathematical model of non-Newtonian blood flow in a vessel. Our model used the Quemada rheological constitutive relationship to express blood viscosity in terms of both hematocrit and shear rate. The model revealed that the net effect of the hemodilution induced by relatively low-viscosity shear thinning PEG-Alb plasma expanders is to reduce overall blood viscosity and to increase the WSS, thus intensifying endothelial NO production. These changes act synergistically, significantly increasing cardiac output and perfusion due to lowered overall peripheral vascular resistance.  相似文献   

15.
Extreme hemodilution was performed in the hamster chamber window model using 6% Dextran 70, lowering systemic hematocrit by 60%. Animals were subsequently divided into three groups and hemodiluted to a hematocrit of 11% using 6% Dextran 70, 6% Dextran 500, and a 4% Dextran 70 + 0.7% alginate solution (n = 6 each group). Final plasma viscosities were 1.4 +/- 0.2, 2.2 +/- 0.1, and 2.7 +/- 0.2 cp, respectively, (P < 0.05, high viscosity vs. low viscosity). Blood viscosities were 2.1 +/- 0.2, 2.9 +/- 0.4, and 3.9 +/- 0.3 cp, respectively. The lowest blood and plasma viscosity group had a significantly lower functional capillary density, 37 +/- 16%, whereas the two high-viscosity solutions were 71 +/- 15% and 76 +/- 12% (P < 0.05, high viscosity vs. low viscosity), respectively. Arteriolar and venular flow in the Dextran 500 and alginate groups was higher than baseline (i.e., normal nontreated animals), whereas the low-viscosity group showed a reduction in flow. These microvascular changes were paralleled by changes in base excess, which was negative for the Dextran 70 group and positive for the other groups. However, tissue Po(2) was uniformly low for all groups (average of 1.4 mmHg). Calculation of tissue oxygen consumption in the window chamber based on the microvascular data, flow, and intravascular Po(2) showed that only the alginate + Dextran 70 solution-exchanged animals returned to baseline oxygen consumption, whereas the other groups were lower than baseline (P < 0.05). These results show that hemodilution performed with high-viscosity plasma expanders yields systemic arterial pressures and functional capillary densities that are significantly higher (P < 0.05) than those obtained with 6% Dextran 70, a fluid whose viscosity is similar to that of plasma. A condition for obtaining these results is that the oncotic pressure of the plasma expander be titrated to near normal, so that autotransfusion of fluid from the tissue into the vascular compartment does not reduce the effects of increasing plasma viscosity and increased shear stress on the microvascular wall.  相似文献   

16.
The effect of isovolemic hemodilution on the circulation of red blood cells (RBCs) in the cerebrocortical capillary network was studied by intravital videomicroscopy with use of a closed-cranial-window technique in the rat. Velocity and supply rate of RBCs were measured by tracking the movement and counting the number of fluorescently labeled cells. Arterial blood was withdrawn in increments of 2 ml and replaced by serum albumin. Arterial blood pressure was maintained constant with an infusion of methoxamine. Both velocity and supply rate of RBCs increased, by approximately equal amounts, as arterial hematocrit was reduced from 44 to 15%. The maximum increase in RBC velocity was 4.6 and in RBC supply rate was 5.2 times the baseline value. Calculated lineal density of RBC, an index of capillary hematocrit, did not change with hemodilution. The results suggest that RBC flow and oxygen supply in the cerebral capillary network are maintained during isovolemic hemodilution. The "optimal hematocrit" is as low as 15%.  相似文献   

17.
Effects of blood viscosity on renin secretion.   总被引:1,自引:0,他引:1  
S Chien  K M Jan  S Simchon 《Biorheology》1990,27(3-4):589-597
The effects of alterations in blood and plasma viscosities on plasma renin activity (PRA) were studied in dogs anesthetized with pentobarbital. Blood viscosity was altered by changing the hematocrit (Hct) level by isovolemic exchange using packed red blood cells or plasma. Plasma viscosity was elevated by isovolemic exchange using Hct-matched blood with high molecular weight dextran (Dx, mean m.w. approximately 450,000) dissolved in plasma. Following control measurements of plasma and blood viscosities, plasma [Dx], PRA, Hct and hemodynamic functions, the dog was subjected to isovolemic exchange transfusions to either alter the Hct or administer the Dx. Various measurements were repeated 40-60 min after each exchange. Arterial pressure and renal blood flow remained relatively constant after exchanges; increases in plasma and blood viscosities were accompanied by a decrease in renal vascular hindrance (vasodilation) to keep the renal flow resistance at control level. PRA rose with increases in plasma [Dx] and viscosity, and the rise in PRA was best correlated with the decrease in renal hindrance. The changes in PRA and renal hindrance have the same regression line whether blood viscosity was altered by Hct variation or Dx administration. The results indicate that increases in viscosity cause a compensatory vasodilation of renal vessels to cause renin secretion.  相似文献   

18.
Studies were carried out in seven anesthetized paralyzed dogs to examine the importance of alpha -adrenergic tone in the cardiovascular responses during acute anemia. Data were obtained 1) at normal hematocrit (Hct), 2) during anemia produced by isovolemic hemodilution with dextran (Hct, 13-15%), 3) during anemia after alpha -blockade (alpha -bl) with phenoxybenzamine (3 mg/kg), and 4) following volume expansion during anemia with a red blood cell dextran solution. Cardiac output (QT), limb and total body oxygen uptake (VO2), and limb blood flow (QL) were determined. Both QT and QL increased during anemia (P less than 0.01), whereas limb resistance (RL) and total peripheral resistance (TPR) were decreased (P less than 0.01). No further change in either RL or TPR occurred with alpha -blockade anemia, but both QT and QL decreased (P less than 0.01). Whole-body VO2 increased during anemia and then declined with alpha -bl and anemia. Following volume expansion during anemia with alpha -bl, QT, QL, and whole-body VO2 increased. We conclude that alpha -adrenergic sympathetic tone to capacitance vessels is essential for the cardiac output increased during anemia, but has little or no effect on resistance vessels and hence distribution of peripheral blood flow.  相似文献   

19.
The rate of oxygen release from arterioles ( approximately 55 microm diameter) was measured in the hamster window chamber model during flow and no-flow conditions. Flow was stopped by microvascular transcutaneous occlusion using a glass pipette held by a manipulator. The reduction of the intra-arteriolar oxygen tension (Po2) was measured by the phosphorescence quenching of preinfused Pd-porphyrin, 100 microm downstream from the occlusion. Oxygen release from arterioles was found to be 53% greater during flow than no-flow conditions (2.6 vs. 1.7 x 10(-5) ml O2.cm(-2).s(-1), P < 0.05). Acute hemodilution with dextran 70 was used to reduce vessel oxygen content, significantly increase wall shear stress (14%, P < 0.05), reduce Hct to 28.4% (SD 1.0) [vs. 48.8% (SD 1.8) at baseline], lower oxygen supply by the arterioles (10%, P < 0.05), and increase oxygen release from the arterioles (39%, P < 0.05). Hemodilution also increased microcirculation oxygen extraction (33% greater than nonhemodilution, P < 0.05) and oxygen consumption by the vessel wall, as shown by an increase in vessel wall oxygen gradient [difference in Po2 between the blood and the tissue side of the arteriolar wall, nonhemodiluted 16.2 Torr (SD 1.0) vs. hemodiluted 18.3 Torr (SD 1.4), P < 0.05]. Oxygen released by the arterioles during flow vs. nonflow was increased significantly after hemodilution (3.6 vs. 1.8 x 10(-5) ml O2.cm(-2).s(-1), P < 0.05). The oxygen cost induced by wall shear stress, suggested by our findings, may be >15% of the total oxygen delivery to tissues by arterioles during flow in this preparation.  相似文献   

20.
The objective of the study was to investigate the effects of plasma viscosity after hemodilution on the thickness of the erythrocyte cell free layer (CFL) and on the interface between the flowing column of erythrocytes and the vascular endothelium. The erythrocyte CFL thickness was measured in the rat cremaster muscle preparation. Plasma viscosity was modified in an isovolemic hemodilution, in which the systemic hematocrit (Hctsys) was lowered to 30%. The plasma expanders (PE) of similar nature and different viscosities were generated by glutaraldehyde polymerization of human serum albumin (HSA) at various molar ratios glutaraldehyde to HSA: (i) unpolymerized HSA; (ii) PolyHSA24:1, molar ratio = 24 and (iii) PolyHSA60:1, molar ratio = 60. The HSA viscosities determined at 200 s(-1) were 1.1, 4.2 and 6.0 dyn x cm(-2), respectively. CFL thickness, vessel diameter and blood flow velocity were measured, while volumetric flow, shear rate and stress were calculated. Hemodilution with PolyHSA60:1 increased plasma viscosity and the blood showed marked shear thinning behavior. CFL thickness decreased as plasma viscosity increased after hemodilution; thus the CFL thickness with HSA and PolyHSA24:1 increased compared to baseline. Conversely, the CFL thickness of PolyHSA60:1 was not different from baseline. Blood flow increased with both PolyHSA's compared to baseline. Wall shear rate and shear stress increased for PolyHSA60:1 compared to HSA and PolyHSA24:1, respectively. In conclusion, PE viscosity determined plasma viscosity after hemodilution and affected erythrocyte column hydrodynamics, changing the velocity profile, CFL thickness, and wall shear stress. This study relates the perfusion caused by PolyHSA60:1 to hemodynamic changes induced by the rheological properties of blood diluted with PolyHSA60:1.  相似文献   