首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Linear regression of efficiency or LRE introduced a new paradigm for conducting absolute quantification, which does not require standard curves, can generate absolute accuracies of ±25% and has single molecule sensitivity. Derived from adapting the classic Boltzmann sigmoidal function to PCR, target quantity is calculated directly from the fluorescence readings within the central region of an amplification profile, generating 4–8 determinations from each amplification reaction.

Findings

Based on generating a linear representation of PCR amplification, the highly visual nature of LRE analysis is illustrated by varying reaction volume and amplification efficiency, which also demonstrates how LRE can be used to model PCR. Examining the dynamic range of LRE further demonstrates that quantitative accuracy can be maintained down to a single target molecule, and that target quantification below ten molecules conforms to that predicted by Poisson distribution. Essential to the universality of optical calibration, the fluorescence intensity generated by SYBR Green I (FU/bp) is shown to be independent of GC content and amplicon size, further verifying that absolute scale can be established using a single quantitative standard. Two high-performance lambda amplicons are also introduced that in addition to producing highly precise optical calibrations, can be used as benchmarks for performance testing. The utility of limiting dilution assay for conducting platform-independent absolute quantification is also discussed, along with the utility of defining assay performance in terms of absolute accuracy.

Conclusions

Founded on the ability to exploit lambda gDNA as a universal quantitative standard, LRE provides the ability to conduct absolute quantification using few resources beyond those needed for sample preparation and amplification. Combined with the quantitative and quality control capabilities of LRE, this kinetic-based approach has the potential to fundamentally transform how real-time qPCR is conducted.  相似文献   

2.
3.

Background  

The challenge of determining amplification efficiency has long been a predominant aspect of implementing real-time qPCR, playing a critical role in the accuracy and reliability that can be achieved. Based upon analysis of amplification profile position, standard curves are currently the gold standard for amplification efficiency determination. However, in addition to being highly resource intensive, the efficacy of this approach is limited by the necessary assumption that all samples are amplified with the same efficiency as predicted by a standard curve. These limitations have driven efforts to develop methods for determining amplification efficiency by analyzing the fluorescence readings from individual amplification reactions. The most prominent approach is based on analysis of the "log-linear region", founded upon the presumption that amplification efficiency is constant within this region. Nevertheless, a recently developed sigmoidal model has provided new insights that challenge such historically held views, dictating that amplification efficiency is not only dynamic, but is linearly coupled to amplicon DNA quantity. Called "linear regression of efficiency" or LRE, this kinetic-based approach redefines amplification efficiency as the maximal efficiency (Emax) generated at the onset of thermocycling.  相似文献   

4.
Fluorescent monitoring of DNA amplification is the basis of real-time PCR, from which target DNA concentration can be determined from the fractional cycle at which a threshold amount of amplicon DNA is produced. Absolute quantification can be achieved using a standard curve constructed by amplifying known amounts of target DNA. In this study, the mathematics of quantitative PCR are examined in detail, from which several fundamental aspects of the threshold method and the application of standard curves are illustrated. The construction of five replicate standard curves for two pairs of nested primers was used to examine the reproducibility and degree of quantitative variation using SYBER® Green I fluorescence. Based upon this analysis the application of a single, well- constructed standard curve could provide an estimated precision of ±6–21%, depending on the number of cycles required to reach threshold. A simplified method for absolute quantification is also proposed, in which quantitative scale is determined by DNA mass at threshold.  相似文献   

5.

Background

State of the art molecular diagnostic tests are based on the sensitive detection and quantification of nucleic acids. However, currently established diagnostic tests are characterized by elaborate and expensive technical solutions hindering the development of simple, affordable and compact point-of-care molecular tests.

Methodology and Principal Findings

The described competitive reporter monitored amplification allows the simultaneous amplification and quantification of multiple nucleic acid targets by polymerase chain reaction. Target quantification is accomplished by real-time detection of amplified nucleic acids utilizing a capture probe array and specific reporter probes. The reporter probes are fluorescently labeled oligonucleotides that are complementary to the respective capture probes on the array and to the respective sites of the target nucleic acids in solution. Capture probes and amplified target compete for reporter probes. Increasing amplicon concentration leads to decreased fluorescence signal at the respective capture probe position on the array which is measured after each cycle of amplification. In order to observe reporter probe hybridization in real-time without any additional washing steps, we have developed a mechanical fluorescence background displacement technique.

Conclusions and Significance

The system presented in this paper enables simultaneous detection and quantification of multiple targets. Moreover, the presented fluorescence background displacement technique provides a generic solution for real time monitoring of binding events of fluorescently labelled ligands to surface immobilized probes. With the model assay for the detection of human immunodeficiency virus type 1 and 2 (HIV 1/2), we have been able to observe the amplification kinetics of five targets simultaneously and accommodate two additional hybridization controls with a simple instrument set-up. The ability to accommodate multiple controls and targets into a single assay and to perform the assay on simple and robust instrumentation is a prerequisite for the development of novel molecular point of care tests.  相似文献   

6.
Quantitative real-time PCR has revolutionized many aspects of genetic research, biomedical diagnostics and pathogen detection. Nevertheless, the full potential of this technology has yet to be realized, primarily due to the limitations of the threshold-based methodologies that are currently used for quantitative analysis. Prone to errors caused by variations in reaction preparation and amplification conditions, these approaches necessitate construction of standard curves for each target sequence, significantly limiting the development of high-throughput applications that demand substantive levels of reliability and automation. In this study, an alternative approach based upon fitting of fluorescence data to a four-parametric sigmoid function is shown to dramatically increase both the utility and reliability of quantitative real-time PCR. By mathematically modeling individual amplification reactions, quantification can be achieved without the use of standard curves and without prior knowledge of amplification efficiency. Combined with provision of quantitative scale via optical calibration, sigmoidal curve-fitting could confer the capability for fully automated quantification of nucleic acids with unparalleled accuracy and reliability.  相似文献   

7.
Amplification of a cDNA product by quantitative PCR (qPCR) is monitored by a fluorescent signal proportional to the amount of produced amplicon. The qPCR amplification curve usually displays an exponential phase followed by a non-exponential phase, ending with a plateau. Contrary to prevalent interpretation, we demonstrate that under standard qPCR conditions, the plateau can be explained by depletion of the probe through Taq polymerase- catalysed hydrolysis. Knowing the probe concentration and the fluorescence measured at the plateau, a specific fluorescence can thus be calculated. As far as probe hydrolysis quantitatively reflects amplicon synthesis, this, in turn, makes it possible to convert measured fluorescence levels in the exponential phase into concentrations of produced amplicon. It follows that the absolute target cDNA concentration initially engaged in the qPCR can be directly estimated from the fluorescence data, with no need to refer to any calibration with known concentrations of target DNA.  相似文献   

8.

Background

Real-time PCR is increasingly being adopted for RNA quantification and genetic analysis. At present the most popular real-time PCR assay is based on the hybridisation of a dual-labelled probe to the PCR product, and the development of a signal by loss of fluorescence quenching as PCR degrades the probe. Though this so-called 'TaqMan' approach has proved easy to optimise in practice, the dual-labelled probes are relatively expensive.

Results

We have designed a new assay based on SYBR-Green I binding that is quick, reliable, easily optimised and compares well with the published assay. Here we demonstrate its general applicability by measuring copy number in three different genetic contexts; the quantification of a gene rearrangement (T-cell receptor excision circles (TREC) in peripheral blood mononuclear cells); the detection and quantification of GLI, MYC-C and MYC-N gene amplification in cell lines and cancer biopsies; and detection of deletions in the OPA1 gene in dominant optic atrophy.

Conclusion

Our assay has important clinical applications, providing accurate diagnostic results in less time, from less biopsy material and at less cost than assays currently employed such as FISH or Southern blotting.  相似文献   

9.

Background

DNA methylation is an important epigenetic mechanism in several human diseases, most notably cancer. The quantitative analysis of DNA methylation patterns has the potential to serve as diagnostic and prognostic biomarkers, however, there is currently a lack of consensus regarding the optimal methodologies to quantify methylation status. To address this issue we compared five analytical methods: (i) MethyLight qPCR, (ii) MethyLight digital PCR (dPCR), methylation-sensitive and -dependent restriction enzyme (MSRE/MDRE) digestion followed by (iii) qPCR or (iv) dPCR, and (v) bisulfite amplicon next generation sequencing (NGS). The techniques were evaluated for linearity, accuracy and precision.

Results

MethyLight qPCR displayed the best linearity across the range of tested samples. Observed methylation measured by MethyLight- and MSRE/MDRE-qPCR and -dPCR were not significantly different to expected values whilst bisulfite amplicon NGS analysis over-estimated methylation content. Bisulfite amplicon NGS showed good precision, whilst the lower precision of qPCR and dPCR analysis precluded discrimination of differences of < 25% in methylation status. A novel dPCR MethyLight assay is also described as a potential method for absolute quantification that simultaneously measures both sense and antisense DNA strands following bisulfite treatment.

Conclusions

Our findings comprise a comprehensive benchmark for the quantitative accuracy of key methods for methylation analysis and demonstrate their applicability to the quantification of circulating tumour DNA biomarkers by using sample concentrations that are representative of typical clinical isolates.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2164-15-1174) contains supplementary material, which is available to authorized users.  相似文献   

10.
11.

Background

There is an increasing need for quantitative technologies suitable for molecular detection in a variety of settings for applications including food traceability and monitoring of genetically modified (GM) crops and their products through the food processing chain. Conventional molecular diagnostics utilising real-time polymerase chain reaction (RT-PCR) and fluorescence-based determination of amplification require temperature cycling and relatively complex optics. In contrast, isothermal amplification coupled to a bioluminescent output produced in real-time (BART) occurs at a constant temperature and only requires a simple light detection and integration device.

Results

Loop mediated isothermal amplification (LAMP) shows robustness to sample-derived inhibitors. Here we show the applicability of coupled LAMP and BART reactions (LAMP-BART) for determination of genetically modified (GM) maize target DNA at low levels of contamination (0.1-5.0% GM) using certified reference material, and compare this to RT-PCR. Results show that conventional DNA extraction methods developed for PCR may not be optimal for LAMP-BART quantification. Additionally, we demonstrate that LAMP is more tolerant to plant sample-derived inhibitors, and show this can be exploited to develop rapid extraction techniques suitable for simple field-based qualitative tests for GM status determination. We also assess the effect of total DNA assay load on LAMP-BART quantitation.

Conclusions

LAMP-BART is an effective and sensitive technique for GM detection with significant potential for quantification even at low levels of contamination and in samples derived from crops such as maize with a large genome size. The resilience of LAMP-BART to acidic polysaccharides makes it well suited to rapid sample preparation techniques and hence to both high throughput laboratory settings and to portable GM detection applications. The impact of the plant sample matrix and genome loading within a reaction must be controlled to ensure quantification at low target concentrations.  相似文献   

12.
13.

Background

Childhood asthma prevalence is widely measured by parental proxy report of physician-diagnosed asthma in questionnaires. Our objective was to validate this measure in a North American population.

Methods

The 2884 study participants were a subsample of 5619 school children aged 5 to 9 years from 231 schools participating in the Toronto Child Health Evaluation Questionnaire study in 2006. We compared agreement between "questionnaire diagnosis" and a previously validated "health claims data diagnosis". Sensitivity, specificity and kappa were calculated for the questionnaire diagnosis using the health claims diagnosis as the reference standard.

Results

Prevalence of asthma was 15.7% by questionnaire and 21.4% by health claims data. Questionnaire diagnosis was insensitive (59.0%) but specific (95.9%) for asthma. When children with asthma-related symptoms were excluded, the sensitivity increased (83.6%), and specificity remained high (93.6%).

Conclusions

Our results show that parental report of asthma by questionnaire has low sensitivity but high specificity as an asthma prevalence measure. In addition, children with "asthma-related symptoms" may represent a large fraction of under-diagnosed asthma and they should be excluded from the inception cohort for risk factor studies.  相似文献   

14.

Background

Trait purity is a key factor for the successful utilization of biotech varieties and is currently assessed by analysis of individual seeds or plants. Here we propose a novel PCR-based approach to test trait purity that can be applied to bulk samples. To this aim the insertion site of a transgene is characterized and the corresponding sequence of the wild-type (wt) allele is used as diagnostic target for amplification. As a demonstration, we developed a real-time quantitative PCR method to test purity of glyphosate tolerant (Roundup Ready®, RR) soybean.

Results

The soybean wt sequence at the RR locus was characterized and found to be highly conserved among conventional genotypes, thus allowing the detection of possibly any soybean non-trait contaminant. On the other hand, no amplification product was obtained from RR soybean varieties, indicating that the wt sequence is single copy and represents a suitable marker of conventional soybean presence. In addition, results obtained from the analysis of wt-spiked RR samples demonstrate that it is possible to use the real-time PCR assay to quantify the non-trait contamination with an acceptable degree of accuracy.

Conclusion

In principle this approach could be successfully applied to any transgenic event, provided that the wild-type sequence is conserved and single copy. The main advantages of the assay here described derive from its applicability to bulk samples, which would allow to increase the number of single seeds or plants forming the analytical sample, thus improving accuracy and throughput while containing costs. For these reasons this application of quantitative PCR could represent a useful tool in agricultural biotechnology.  相似文献   

15.

Background

We recently described Hi-Plex, a highly multiplexed PCR-based target-enrichment system for massively parallel sequencing (MPS), which allows the uniform definition of library size so that subsequent paired-end sequencing can achieve complete overlap of read pairs. Variant calling from Hi-Plex-derived datasets can thus rely on the identification of variants appearing in both reads of read-pairs, permitting stringent filtering of sequencing chemistry-induced errors. These principles underly ROVER software (derived from Read Overlap PCR-MPS variant caller), which we have recently used to report the screening for genetic mutations in the breast cancer predisposition gene PALB2. Here, we describe the algorithms underlying ROVER and its usage.

Results

ROVER enables users to quickly and accurately identify genetic variants from PCR-targeted, overlapping paired-end MPS datasets. The open-source availability of the software and threshold tailorability enables broad access for a range of PCR-MPS users.

Methods

ROVER is implemented in Python and runs on all popular POSIX-like operating systems (Linux, OS X). The software accepts a tab-delimited text file listing the coordinates of the target-specific primers used for targeted enrichment based on a specified genome-build. It also accepts aligned sequence files resulting from mapping to the same genome-build. ROVER identifies the amplicon a given read-pair represents and removes the primer sequences by using the mapping co-ordinates and primer co-ordinates. It considers overlapping read-pairs with respect to primer-intervening sequence. Only when a variant is observed in both reads of a read-pair does the signal contribute to a tally of read-pairs containing or not containing the variant. A user-defined threshold informs the minimum number of, and proportion of, read-pairs a variant must be observed in for a ‘call’ to be made. ROVER also reports the depth of coverage across amplicons to facilitate the identification of any regions that may require further screening.

Conclusions

ROVER can facilitate rapid and accurate genetic variant calling for a broad range of PCR-MPS users.  相似文献   

16.

Background

The Global Programme to Eliminate Lymphatic Filariasis (GPELF) depends upon Mass Drug Administration (MDA) to interrupt transmission. Therefore, delimitation of transmission risk areas is an important step, and hence we attempted to define a geo-environmental risk model (GERM) for determining the areas of potential transmission of lymphatic filariasis.

Methods

A range of geo-environmental variables has been selected, and customized on GIS platform to develop GERM for identifying the areas of filariasis transmission in terms of "risk" and "non-risk". The model was validated through a 'ground truth study' following standard procedure using GIS tools for sampling and Immuno-chromotographic Test (ICT) for screening the individuals.

Results

A map for filariasis transmission was created and stratified into different spatial entities, "risk' and "non-risk", depending on Filariasis Transmission Risk Index (FTRI). The model estimation corroborated well with the ground (observed) data.

Conclusion

The geo-environmental risk model developed on GIS platform is useful for spatial delimitation purpose on a macro scale.  相似文献   

17.

Background

The polymerase chain reaction amplifies and quantifies small amounts of DNA. It is a cyclic process, during each cycle of which each strand of template DNA is copied with probability approaching one: the amount of DNA approximately doubles and this amount can be estimated fluorimetrically each cycle, producing a set of fluorescence values hereafter referred to as the amplification curve. Commonly the biological question of relevance is one of the ratio of DNA concentrations in two samples: a ratio that is deduced by comparing the two amplification curves, usually by way of a plot of fluorescence against cycle number. Central to this analysis is measuring the extent to which one amplification curve is shifted relative to the other, a measurement often accomplished by defining a threshold or quantification cycle, Cq, for each curve: the fractional cycle number at which fluorescence reaches some threshold or at which some other criterion (maximum slope, maximum rate of change of slope) is satisfied.We propose an alternative where position is measured relative to a reference curve; position equates to the cycle shift which maximizes the correlation between the reference and the observed fluorescence sequence. A key parameter of the reference curve is obtained by fixed-point convergence.

Results

We consider the analysis of dilution series constructed for the estimation of qPCR amplification efficiency. The estimate of amplification efficiency is based on the slope of the regression line when the Cq is plotted against the logarithm of dilution. We compare the approach to three commonly used methods for determining Cq; each is applied to publicly accessible calibration data sets, and to ten from our own laboratory. As in the established literature we judge their relative merits both from the standard deviation of the slope of the calibration curve, and from the variance in Cq for replicate fluorescence curves.

Conclusions

The approach does not require modification of experimental protocols, and can be applied retrospectively to existing data. We recommend that it be added to the methodological toolkit with which laboratories interpret their real-time PCR data.

Electronic supplementary material

The online version of this article (doi:10.1186/s12859-014-0372-4) contains supplementary material, which is available to authorized users.  相似文献   

18.
19.

Background

An adequate and expressive ontological representation of biological organisms and their parts requires formal reasoning mechanisms for their relations of physical aggregation and containment.

Results

We demonstrate that the proposed formalism allows to deal consistently with "role propagation along non-taxonomic hierarchies", a problem which had repeatedly been identified as an intricate reasoning problem in biomedical ontologies.

Conclusion

The proposed approach seems to be suitable for the redesign of compositional hierarchies in (bio)medical terminology systems which are embedded into the framework of the OBO (Open Biological Ontologies) Relation Ontology and are using knowledge representation languages developed by the Semantic Web community.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号