首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A technique of phase-polarisation contrast (PPC) for the enhancement of the contrast of a surface plasmon resonance (SPR) intensity profile is proposed and experimentally realised. The technique exploits the peculiarities of light phase and polarisation behaviour under SPR. It applies to non-optimum SPR coupling conditions and enables one to lower the resonant minimum of reflected intensity nearly to zero, and hence to increase substantially the ratio of the intensity from the resonance to that at the minimum. We observed the contrast enhancement by more than one order of magnitude when we applied the PPC scheme. The PPC can be efficiently employed in commercial SPR sensors, as it significantly reduces restrictions on allowable parameters of SPR-supporting metal films and biomolecular layers immobilised on them, facilitates SPR observation, and increases the accuracy of SPR shift measurements.  相似文献   

2.
The emergence of surface plasmon resonance-based optical biosensors has facilitated the identification of kinetic parameters for various macromolecular interactions. Normally, these parameters are determined from experiments with arbitrarily chosen periods of macromolecule and buffer injections, and varying macromolecule concentrations. Since the choice of these variables is arbitrary, such experiments may not provide the required confidence in identified kinetic parameters expressed in terms of standard errors. In this work, an iterative optimization approach is used to determine the above-mentioned variables so as to reduce the experimentation time, while treating the required standard errors as constraints. It is shown using multiple experimental and simulated data that the desired confidence can be reached with much shorter experiments than those generally performed by biosensor users.  相似文献   

3.
We enhanced the sensitivity of surface plasmon resonance biosensor by the conversion of the real-time direct binding immunoassay into the sandwich immunoassay, in which colloidal gold particles coated with anti-mouse IgG was used. By the immobilization of anti-mouse IgG onto the carboxymethyl dextran surface of thin gold film, the direct binding of analyte (mouse IgG) onto the sensor chip, and the injection of colloidal gold particles coated with antimouse IgG, about 100 times of sensitivity enhancement was obtained. This result suggests that nanoparticles, which has a high refractive index, homogeneous ultrafine structure and capability of size control, would be applicable for the detection of very small quantity of biomaterial.  相似文献   

4.
Optical Surface plasmon resonance (SPR) biosensors represent the most advanced and developed optical label‐free biosensor technology. Optical SPR biosensors are a powerful detection and analysis tool that has vast applications in environmental protection, biotechnology, medical diagnostics, drug screening, food safety and security. This article reviews the recent development of SPR biosensor techniques, including bulk SPR and localized SPR (LSPR) biosensors, for detecting interactions between an analyte of interest in solution and a biomolecular recognition. The concepts of bulk and localized SPs and the working principles of both sensing techniques are introduced. Major sensing advances on biorecognition elements, measurement formats, and sensing platforms are presented. Finally, the discussions on both biosensor techniques as well as comparison of both SPR sensing techniques are made. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

5.
In this article, we report for the first time, the detection of circulating miRNA as a breast cancer biomarker in patient sera using surface plasmon resonance imaging biosensor. The advantage of this approach lies in the rapid, label-free and sensitive detection. The sensor excites plasmonic resonance on the gold sensor surface and specific DNA-miRNA molecular bindings elucidate responses in the plasmonic resonance image. Experiments of detecting synthetic miRNA molecules (miR-1249) were performed and the sensor resolution was found to be 63.5 nM. The sensor was further applied to screen 17 patient serum samples from National Cancer Centre Singapore and Tan Tock Seng Hospital. Sensor intensity response was found to differ by 20% between malignant and benign cases and thus forms, a potential and an important metric in distinguishing benignity and malignancy.  相似文献   

6.
7.
利用一种全新的生物大分子相互作用检测仪表面等离子激元共振(SPR)生物传感器,对乙肝表面抗原,抗体,破伤风类毒素,抗体等生物制品进行生物特异性相互作用分析(BIA),并对其在免疫学检测上的特征进行了探讨。  相似文献   

8.
A surface plasmon resonance biosensor (Biacore) was used to detect Salmonella through antibodies reacting with Salmonella group A, B, D and E (Kauffmann-White typing). In the assay designed, anti-Salmonella antibodies immobilized to the biosensor surface were allowed to bind injected bacteria followed by a pulse with soluble anti-Salmonella immunoglobulins to intensify the signal. No significant interference was found for (mixtures of) 30 non-Salmonella serovars at 10(9) CFU ml(-1). A total of 53 Salmonella serovars were successfully detected at 1 x 10(7) CFU ml(-1), except those of groups C, G, L and P, as expected. The cut-off point was determined with an equicellular mixture of Salmonella enteritidis and Salmonella typhimurium at a final amount of 1.7 x 10(3) CFU per test portion. Although further work is needed to cover the detection of all relevant Salmonella serovars in food-producing animals and food products, this work demonstrates the merits of this alternative biosensor approach in terms of automation, sensitivity, specificity, simple handling and limited hands-on time.  相似文献   

9.
Type 2 diabetes affects millions of people worldwide, and measuring the kinetics of insulin receptor‐insulin interactions is critical to improving our understanding of this disease. In this paper, we describe, for the first time, a rapid, real‐time, multiplex surface plasmon resonance (SPR) assay for studying the interaction between insulin and the insulin receptor ectodomain, isoform A (eIR‐A). We used a scaffold approach in which anti‐insulin receptor monoclonal antibody 83–7 (Abcam, Cambridge, UK) was first immobilized on the SPR sensorchip by amine coupling, followed by eIR‐A capture. The multiplex SPR system (ProteOn XPR36?, Bio‐Rad Laboratories, Hercules, CA) enabled measurement of replicate interactions with a single, parallel set of analyte injections, whereas repeated regeneration of the scaffold between measurements caused variable loss of antibody activity. Interactions between recombinant human insulin followed a two‐site binding pattern, consistent with the literature, with a high‐affinity site (dissociation constant KD1 = 38.1 ± 0.9 nM) and a low‐affinity site (KD2 = 166.3 ± 7.3 nM). The predominantly monomeric insulin analogue Lispro had corresponding dissociation constants KD1 = 73.2 ± 1.8 nM and KD2 = 148.9 ± 6.1 nM, but the fit to kinetic data was improved when we included a conformational change factor in which the high‐affinity site was converted to the low‐affinity site. The new SPR assay enables insulin‐eIR‐A interactions to be followed in real time and could potentially be extended to study the effects of humoral factors on the interaction, without the need for insulin labeling. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
A new, powerful method is presented for screening the binding in real time and taking place under dynamic conditions of oligosaccharides to lectins. The approach combines an SPR biosensor and HPLC profiling with fluorescence detection, and is applicable to complex mixtures of oligosaccharides in terms of ligand-fishing. Labeling the oligosaccharides with 2-aminobenzamide ensures a detection level in the fmol range. In an explorative study the binding of RNase B-derived oligomannose-type N-glycans to biosensor-immobilized concanavalin A (Con A) was examined, and an affinity ranking could be established for Man(5)GlcNAc(2) to Man(9)GlcNAc(2), as monitored by HPLC. In subsequent experiments and using well-defined labeled as well as nonlabeled oligosaccharides, it was found that the fluorescent tag does not interfere with the binding and that the optimum epitope for the interaction with Con A comprises the tetramannoside unit Manalpha2Manalpha6(Manalpha3)Man[D(3)B(A)4'], rather than the generally accepted trimannoside Manalpha6 (Manalpha3)Man [B(A)4' or 4(4')3]. In a similar experimental setup, the interaction of various fucosylated human milk oligosaccharides with the fucose-binding lectin from Lotus tetragonolobus purpureaus was studied, and it appeared that oligosaccharides containing blood group H could selectively be retained and eluted from the lectin-coated surface. Finally, using the same lectin and a mixture of O-glycans derived from bovine submaxillary gland mucin, minor constituents but containing fucose could selectively be picked from the analyte solution as demonstrated by HPLC profiling.  相似文献   

11.
Surface plasmon resonance-based biosensors are now acknowledged as robust and reliable instruments to determine the kinetic parameters related to the interactions between biomolecules. These kinetic parameters are used in screening campaigns: there is a considerable interest in reducing the experimental time, thus improving the throughput of the surface plasmon resonance assays. Kinetic parameters are typically obtained by analyzing data from several injections of a given analyte at different concentrations over a surface where its binding partner has been immobilized. It has been already proven that an iterative optimization approach aiming at determining optimal analyte injections to be performed online can significantly reduce the experimentation time devoted to kinetic parameter determination, without any detrimental effect on their standard errors. In this study, we explore the potential of this iterative optimization approach to further reduce experiment duration by combining it with the simultaneous injection of two analytes.  相似文献   

12.
Aspartic peptidase inhibitors, which are themselves proteins, are strong inhibitors (small inhibition constants) of some aspartic peptidases but not others. However, there have been no studies of the kinetics of the interaction between a proteinaceous aspartic peptidase inhibitor and aspartic peptidases. This paper describes an analysis of rate constants for the interaction between recombinant squash aspartic peptidase inhibitor (rSQAPI) and a panel of aspartic peptidases that have a range of inhibition constants for SQAPI. Purified rSQAPI completely inhibits pepsin at a 1:1 molar ratio of pepsin to rSQAPI monomer (inhibition constant 1 nM). The interaction of pepsin with immobilized rSQAPI, at pH values between 3.0 and 6.0, was monitored using surface plasmon resonance. Binding of pepsin to rSQAPI was slow (association rate constants ca 10(4)M (-1)s(-1)), but rSQAPI was an effective pepsin inhibitor because dissociation of the rSQAPI-pepsin complex was much slower (dissociation rate constants ca 10(-4)s(-1)), especially at low pH values. Similar results were obtained with a His-tagged rSQAPI. Strong inhibition (inhibition constant 3 nM) of one isoform (rSap4) of the family of Candida albicans-secreted aspartic peptidases was, as with pepsin, characterized by slow binding of rSap4 and slower dissociation of the rSap4-inhibitor complex. In contrast, weaker inhibition of the Glomerella cingulata-secreted aspartic peptidase (inhibition constant 7 nM) and the C. albicans rSap1 and Sap2 isoenzymes (inhibition constants 25 and 400 nM, respectively) was, in each case, characterized by a larger dissociation rate constant.  相似文献   

13.
Surface plasmon resonance (SPR) biosensor formats using gold nanoparticle or protein signal amplification for the sensitive assay of small molecules were developed using progesterone as a model compound. Progesterone was immobilized to a dextran surface in the Biacore biosensor through in situ covalent immobilization using an oligoethylene glycol linker attached to the 4 position of the steroid. This surface produced stable antibody binding for in excess of 1100 assay cycles. Using this surface, assays were developed for progesterone using 10- and 20-nm gold-streptavidin labels attached to biotinylated monoclonal antibody in both label prebinding and sequential binding formats. Prelabeling formats gave no signal enhancement but produced assays with limits of detection of 143 pg/ml, compared with approximately 1 ng/ml in previous studies. Sequential binding formats gave signal enhancements of 2.2-fold over the monoclonal antibody and a limit of detection of 23.1 pg/ml. It was found that secondary antibody labeling gave 8.1-fold signal enhancements and a limit of detection of 20.1 pg/ml, whereas use of secondary antibody-25 nm gold complexes provided more signal enhancement (13-fold) and a further improvement in limit of detection of 8.6 pg/ml.  相似文献   

14.
An absorption-based surface plasmon resonance (SPR(Abs)) biosensor probe has been developed for simple and reproducible measurements of hydrogen peroxide using a modified Trinder's reagent (a chromogenic reagent). The reagent enabled the determination of the hydrogen peroxide concentration by the development of deep color dyes (lambda(max)=630nm) through the oxidative coupling reaction with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethylaniline sodium salt monohydrate (MAOS; C(13)H(20)NNaO(4)S.H(2)O) and 4-aminoantipyrine (4-AA) in the presence of hydrogen peroxide and horseradish peroxidase (HRP). In the present study, urea as an adduct of hydrogen peroxide for color development could be omitted from the measurement solution. The measurement solution containing 5mM hydrogen peroxide was deeply colored at a high absorbance value calculated as 46.7cm(-1) and was directly applied to the SPR(Abs) biosensing without dilution. The measurement was simply performed by dropping the measurement solution onto the surface of the SPR sensor probe, and the SPR(Abs) biosensor response to hydrogen peroxide was obtained as a reflectivity change in the SPR spectrum. After investigation of the pH profiles in the SPR(Abs) biosensor probe, a linear calibration curve was obtained between 1.0 and 50mM hydrogen peroxide (r=0.991, six points, average of relative standard deviation; 0.152%, n=3) with a detection limit of 0.5mM. To examine the applicability of this SPR(Abs) biosensor probe, 20mM glucose detection using glucose oxidase was also confirmed without influence of the refractive index in the measurement solution. Thus, the SPR(Abs) biosensor probe employing the modified Trinder's reagent demonstrated applicability to other analyte biosensing tools.  相似文献   

15.
We performed a basic experiment for the rapid, on-line, real-time measurement of hepatitis B surface antigen using a surface plasmon resonance biosensor. We immobilized anti-HBsAg (hepatitis B surface antigen) polyclonal antibody, as a ligand, to the dextran layer on a CM5 chip surface that had previously been activated byN-hydroxysuccinimide. A sample solution containing HBsAg was fed through a microfluidic channel, and the reflecting angle change due to the mass increase from the binding was detected. The binding characteristics between HBsAg and its polyclonal antibody followed the typical monolayer adsorption isotherm. When the entire immobilized antibody had interacted, no additional, non-specific binding occurred, suggesting the immunoreaction was very specific. The bound antigen per unit mass of the antibody was independent of the immobilized ligand density. No significant steric hindrance was observed at an immobilization density of approximately 17.6 ng/mm2. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the ligand was linear up to ca. 40 μg/mL. This linearity was much higher than that of the ELISA method. It appeared the antigen-antibody binding increased as the immobilized ligand density increased. In summary, this study showed the potential of this SPR biosensor-based method as a rapid, simple and multi-sample on-line assay. Once properly validated, it may serve as a more efficient method for HBsAg quantification for replacing the ELISA.  相似文献   

16.
Surface plasmon resonance (SPR) was used as an affinity biosensor to determine absolute heparin concentrations in human blood plasma samples. Protamine and polyethylene imine (PEI) were evaluated as heparin affinity surfaces. Heparin adsorption onto protamine in blood plasma was specific with a lowest detection limit of 0.2 U/ml and a linear window of 0.2–2 U/ml. Although heparin adsorption onto PEI in buffer solution had indicated superior sensitivity to that on protamine, in blood plasma it was not specific for heparin and adsorbed plasma species to a steady-state equilibrium. By reducing the incubation time and diluting the plasma samples with buffer to 50%, the non-specific adsorption of plasma could be controlled and a PEI pre-treated with blood plasma could be used successfully for heparin determination. Heparin adsorption in 50% plasma was linear between 0.05 and 1 U/ml so that heparin plasma levels of 0.1–2 U/ml could be determined within a relative error of 11% and an accuracy of 0.05 U/ml.  相似文献   

17.
Surface plasmon resonance (SPR) is a powerful technique for measuring molecular interaction in real-time. SPR can be used to detect molecule to cell interactions as well as molecule to molecule interactions. In this study, the SPR-based biosensing technique was applied to real-time monitoring of odorant-induced cellular reactions. An olfactory receptor, OR I7, was fused with a rho-tag import sequence at the N-terminus of OR I7, and expressed on the surface of human embryonic kidney (HEK)-293 cells. These cells were then immobilized on a SPR sensor chip. The intensity of the SPR response was linearly dependent on the amount of injected odorant. Among all the aldehyde containing odorants tested, the SPR response was specifically high for octanal, which is the known cognate odorant for the OR I7. This SPR response is believed to have resulted from intracellular signaling triggered by the binding of odorant molecules to the olfactory receptors expressed on the cell surface. This SPR system combined with olfactory receptor-expressed cells provides a new olfactory biosensor system for selective and quantitative detection of volatile compounds.  相似文献   

18.
A surface plasmon resonance (SPR) sensor probe with integrated reference surface is described. In order to fabricate the integrated reference surface, two dielectric layers with different thickness were deposited on the single gold SPR sensor surface via plasma polymerization of hexamethyldisiloxane. The working sensor surface was a 34 nm dielectric layer with immobilized bovine serum albumin (BSA) antigen and an adjacent thin 1 nm dielectric layer without BSA provided reference surface. A specific immunoreaction of anti-BSA antibody was detected after immersion of the SPR probe into sample solution. Simultaneous observation of reference and working surface response enabled determination of the immunoreaction without the need for the baseline measurement. Moreover, compensation of nonspecific adsorption could be confirmed using anti-human serum albumin antibody.  相似文献   

19.
陈巨莲 《昆虫知识》2003,40(2):119-123
表面质膜共振 (SPR)技术是一种监测生物大分子之间特异结合反应的物理方法。该文综述了SPR技术的特点 ,操作方法 ,光学结构及监测原理 ,数据采集及分析方法 ,应用范围其存在的问题等。同时 ,展望了该技术在昆虫学研究中广阔的应用前景。  相似文献   

20.
A technique of phase-polarisation contrast (PPC) for the enhancement of the contrast of a surface plasmon resonance (SPR) intensity profile is proposed and experimentally realised. The technique exploits the peculiarities of light phase and polarisation behaviour under SPR. It applies to non-optimum SPR coupling conditions and enables one to lower the resonant minimum of reflected intensity nearly to zero, and hence to increase substantially the ratio of the intensity from the resonance to that at the minimum. We observed the contrast enhancement by more than one order of magnitude when we applied the PPC scheme. The PPC can be efficiently employed in commercial SPR sensors, as it significantly reduces restrictions on allowable parameters of SPR-supporting metal films and biomolecular layers immobilised on them, facilitates SPR observation, and increases the accuracy of SPR shift measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号