首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A method for the quantification of ergosterol by atmospheric pressure chemical ionization (APcI) mass spectrometry with direct injection is described. Ergosterol and squalene were ionizable with methanol as the carrier solvent. Using positive-mode tandem mass spectrometry (MS/MS), ergosterol could be identified unambiguously without interference from structurally related compounds such as lanosterol, cholesterol, and squalene. Molecular ions of ergosterol, lanosterol, and cholesterol were detected as the [M + H - H(2)O](+) ion species, while squalene appeared as the [M + H](+) ion species. Upon fragmentation of the three sterols and squalene, the product ion at m/z 69 was present as one of the major fragments in all four compounds. This product ion was used for the quantification of ergosterol in multiple-reaction-monitoring acquisition mode. The relationship between signal intensity and ergosterol concentration was linear over the concentration range of 0.15 to 5 microg/ml, or 7. 56-252 pmol ergosterol per 20 microl injection. The plasma membrane ergosterol of the yeast Saccharomyces cerevisiae could be quantified reproducibly without the need for prior separation from other lipids or derivatization. Six repeated injections of ergosterol standards at concentrations of 0.95 and 4.25 microg/ml gave standard deviations of 0.031 and 0.084, respectively, and coefficients of variation of 3.33 and 1.98%, respectively. The coefficient of variation for the four independently extracted membrane ergosterol samples was 11.18%. The presence of other lipids in a crude lipid extract did not interfere with the ergosterol determination. Direct injection APcI with multiple reaction monitoring is aconvenient and sensitive method for ergosterol quantification requiring no prior fractionation.  相似文献   

2.
Sulfonyl chlorides substituted with functional groups having high proton affinity can serve as derivatization reagents to enhance the sensitivity for steroidal estrogens in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The most commonly used reagent for derivatization of estrogens for LC-ESI-MS/MS is dansyl chloride. In this study, we compared dansyl chloride, 1,2-dimethylimidazole-4-sulfonyl (DMIS) chloride, pyridine-3-sulfonyl (PS) chloride, and 4-(1H-pyrazol-1-yl)benzenesulfonyl (PBS) chloride for derivatization of 17beta-estradiol (E2) prior to LC-ESI-MS/MS. The product ion spectra of the dansyl and DMIS derivatives were dominated by ions representing derivatization reagent moieties. In contrast, the product ion spectrum of the PS derivative of E2 and, to a lesser extent, the PBS derivative, showed analyte-specific fragment ions. Derivatization with PS chloride was therefore chosen for further investigation. The product ion spectrum of the PS derivative of E2 showed intense ions at m/z 272, assigned to the radical E2 cation, and at m/z 350, attributed to the loss of SO(2) from the [M+H](+) ion. Third-stage mass spectrometry of the PS derivative of E2 with isolation and collisional activation of the m/z 272 ion resulted in steroid C and D ring cleavages analogous to those observed in electron ionization mass spectrometry. The product ion spectra of the PS derivatives of estrone, 17alpha-ethinylestradiol, equilin, and equilenin showed similar estrogen-specific ions. Using derivatization with PS chloride, we developed an LC-ESI-MS/MS method with multiple reaction monitoring of primary and confirmatory precursor-to-product ion transitions for the determination of E2 in serum.  相似文献   

3.
A rapid, sensitive and specific high performance liquid chromatography-electrospray ionization tandem quadrupole mass spectrometry (HPLC-MS/MS) method was developed and validated for the determination of 3-n-butylphthalide in rat plasma. Following protein precipitation with acetonitrile, 3-n-butylphthalide and glipizide (internal standard, I.S.) were separated using a gradient elution program on a C18 column and detected by mass spectrometry in positive ion mode with the multiple reaction monitoring (MRM) mode using the respective precursor to product ion combinations of m/z 191/145 for 3-n-butylphthalide and m/z 446/321 for glipizide, respectively. The total chromatographic running time was 2.5 min. The method was linear over the concentration range of 11.14-3480.00 ng/mL, using as little as 100 microL plasma. The lower limit of quantification (LLOQ) was 5.57 ng/mL. Finally, the method was successfully used to support a preclinical pharmacokinetic study of 3-n-butylphthalide in rats following intravenous administration.  相似文献   

4.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. After a simple protein precipitation using acetonitrile, the analytes were separated on a Zorbax SB-Aq C18 column using acetonitrile-10mM ammonium acetate (60:40, v/v, pH 4.5) as mobile phase at a flow rate of 1.2 mL/min. Valsartan and hydrochlorothiazide were eluted at 2.08 min and 1.50 min, respectively, ionized using ESI source, and then detected by multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 434.2-350.2 and m/z 295.9-268.9 were used to quantify valsartan and hydrochlorothiazide, respectively. The method was linear in the concentration range of 4-3600 ng/mL for valsartan and 1-900 ng/mL for hydrochlorothiazide. The method was successfully employed in a pharmacokinetic study after an oral administration of a dispersible tablet containing 80 mg valsartan and 12.5 mg hydrochlorothiazide to each of the 20 healthy volunteers.  相似文献   

5.
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration.  相似文献   

6.
A sensitive high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) assay was developed to determine raltitrexed in human plasma. After addition of benazeprilat as the internal standard (IS), methanol was used to produce a protein-free extract. Chromatographic separation was achieved with a Zorbax SB-C18 column (Narrow-Bore 2.1 mmx150 mm, 5-microm) using a mobile phase of acetonitrile-water containing 0.1% formic acid and 2% methanol (21.9:78.1, v/v). Raltitrexed was determined with electrospray ionization-mass spectrometry. HPLC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M+H]+ m/z 459.1 for raltitrexed and [M+H]+ m/z 397.1 for IS. Calibration curves were linear over the range of 2.0-3000 ng/ml. The lower limit of quantification was 2.0 ng/ml. The intra- and inter-batch variability values were less than 6.7% and 10.3%, respectively. The mean plasma extraction recovery of raltitrexed was in the range of 85.2-91.1%. The method was successfully applied to determine the plasma concentrations of raltitrexed in eight Chinese colorectal cancer patients.  相似文献   

7.
Adducts of catechols and histidine, which are produced by reactions of 1,2-quinones and p-quinone methides with histidyl residues in proteins incorporated into the insect exoskeleton, were characterized using electrospray ionization mass spectrometry (ESMS), tandem electrospray mass spectrometry (ESMS-MS, collision-induced dissociation), and ion trap mass spectrometry (ITMS). Compounds examined included adducts obtained from acid hydrolysates of Manduca sexta (tobacco hornworm) pupal cuticle exuviae and products obtained from model reactions under defined conditions. The ESMS and ITMS spectra of 6-(N-3')-histidyldopamine [6-(N-3')-His-DA, pi isomer] isolated from M. sexta cuticle were dominated by a [M + H]+ ion at m/z 308, rather than the expected m/z 307. High-resolution fast atom bombardment MS yielded an empirical formula of C14H18N3O5, which was consistent with this compound being 6-(N-1')-histidyl-2-(3, 4-dihydroxyphenyl)ethanol [6-(N-1')-His-DOPET] instead of a DA adduct. Similar results were obtained when histidyl-catechol compounds linked at C-7 of the catechol were examined; the (N-1') isomer was confirmed as a DA adduct, and the (N-3') isomer identified as an (N-1')-DOPET derivative. Direct MS analysis of unfractionated cuticle hydrolysate revealed intense parent and product ions characteristic of 6- and 7-linked adducts of histidine and DOPET. Mass spectrometric analysis of model adducts synthesized by electrochemical oxidative coupling of N-acetyldopamine (NADA) quinone and N-acetylhistidine (NAcH) identified the point of attachment in the two isomers. A prominent product ion corresponding to loss of CO2 from [M + H]+ of 2-NAcH-NADA confirmed this as being the (N-3') isomer. Loss of (H2O + CO) from 6-NAcH-NADA suggested that this adduct was the (N-1') isomer. The results support the hypothesis that insect cuticle sclerotization involves the formation of C-N cross-links between histidine residues in cuticular proteins, and both ring and side-chain carbons of three catechols: NADA, N-beta-alanyldopamine, and DOPET.  相似文献   

8.
A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.  相似文献   

9.
Rimonabant is the first therapeutically relevant cannabinoid antagonist, licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma and hair using liquid chromatography coupled to mass spectrometry (LC-MS/MS). Rimonabant and AM-251 (internal standard) were extracted from 50muL of plasma or 10mg of hair using diethylether. Chromatography was performed on a 150mmx2.1mm C18 column using a mobile phase constituted of formate buffer/acetonitrile. Rimonabant was ionized by electrospray in positive mode, followed by detection with mass spectrometry. Data were collected either in full-scan MS or in full-scan MS/MS mode, selecting the ion m/z 463.1 for rimonabant and m/z 555.1 for IS. The most intense product ion of rimonabant (m/z 380.9) and IS (m/z 472.8) were used for quantification. Calibration curves covered a range from 2.5 (lower limit of quantification) to 1000.0ng/mL (upper limit of quantification) in plasma and from 2.5 to 1000.0pg/mg in hair. Validation results demonstrated that rimonabant could be accurately and precisely quantified in both matrixes: accuracy and precision were within 85-115% and within 15% of standard deviation, respectively. Stability studies in plasma showed that rimonabant was stable during the assay procedure, but a 30% decrease was observed for one concentration after 3 weeks at -20 degrees C. This simple and robust LC-MS/MS method can be used for measuring rimonabant concentrations in human plasma and hair either in clinical or in forensic toxicology.  相似文献   

10.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

11.
We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (II) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389>201 for I and m/z 502>467 for II. The limit of quantification and the dynamic range achieved were 0.5ng/mL and 0.5-500.0ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48h after oral administration of 5mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies.  相似文献   

12.
A sensitive method for the determination of carbamazepine and carbamazepine 10,11-epoxide in plasma is described, using high-performance liquid chromatographic separation with tandem mass spectrometry. Samples were purified using liquid-liquid extraction and separated on a Phenomenex Luna C18 5 microm. 150 x 2 mm column with a mobile phase consisting of acetonitrile, methanol and formic acid (0.1%) (10:70:20, v/v). Detection was performed by a Micromass Quattro Ultima mass spectrometer in the MRM mode (LC-MS-MS) using electro spray ionisation (ESI+), monitoring the transition of the protonated molecular ion for carbamazepine at m/z 237.05 and carbamazepine 10,11-epoxide at m/z 253.09 to the predominant ions of m/z 194.09 and 180.04, respectively. The mean recovery was 95% for carbamazepine and 101% for carbamazepine 10,11-epoxide, with a lower limit of quantification of 0.722 ng/ml for carbamazepine and 5.15 ng/ml for carbamazepine 10,11-epoxide, when using 0.5 ml plasma. This high-throughput method was used to quantify 230 samples per day, and is sufficiently sensitive to be employed in pharmacokinetic studies.  相似文献   

13.
Letosteine has been found to be effective in treating patients with chronic bronchopneumopathies in clinical practice. To provide robust support for its pharmacokinetic and clinical studies, a rapid and sensitive method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the analysis of letosteine in plasma samples. After protein precipitation, the plasma samples were separated on a reversed-phase C(18) column in less than 1.5 min. The LC-MS/MS system was performed in the positive ion multiple-reaction-monitoring (MRM) mode to produce intensive product ions of m/z 280.1→160.0 for letosteine and m/z 248.1→121.1 for the internal standard, tinidazole. The method was found to have excellent linearity (r ≥ 0.9974), precision (RSD ≤ 5.83%), extraction recovery (71.8-73.0%) and stability (RE, -8.45% to 9.03%) over a concentration range of 0.1140-152.0 μgL(-1). Compared to the previous published radioactive method, LC-MS/MS method showed many advantages including shorter analysis time, simpler preparation procedure, increased sensitivity as well as lower safety risks. In addition, this method was successfully applied to study the pharmacokinetics of letosteine following a single and multiple dose oral administration in Chinese healthy volunteers.  相似文献   

14.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

15.
Mass spectrometry of disaccharides in the negative-ion mode frequently generates product anions of m/z 221. With glucose-containing disaccharides, dissociation of isolated m/z 221 product ions in a Paul trap yielded mass spectra that easily differentiated between both anomeric configurations and ring forms of the ions. These ions were shown to be glucosyl-glycolaldehydes through chemical synthesis of their standards. By labeling the reducing carbonyl oxygen of disaccharides with 18O to mass discriminate between monosaccharides, it was established that the m/z 221 ions are comprised solely of an intact nonreducing sugar with a two-carbon aglycon derived from the reducing sugar, regardless of the disaccharide linkage position. This enabled the anomeric configuration and ring form of the ion to be assigned and the location of the ion to the nonreducing side of a glycosidic linkage to be ascertained. Detailed studies of experimental factors necessary for reproducibility in a Paul trap demonstrated that the unique dissociation patterns that discriminate between the isomeric m/z 221 ions could be obtained from month-to-month in conjunction with an internal energy-input calibrant ion that ensures reproducible energy deposition into isolated m/z 221 ions. In addition, MS/MS fragmentation patterns of disaccharide m/z 341 anions in a Paul trap enabled linkage positions to be assigned, as has been previously reported with other types of mass spectrometers.  相似文献   

16.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for simultaneous quantitation of dexamethasone palmitate and dexamethasone in human plasma was developed. After sample preparation by protein precipitation and liquid-liquid extraction, the analytes and internal standard (IS) were separated on a Venusil XBP-C8 column using gradient elution. Multiple reaction monitoring of dexamethasone palmitate, dexamethasone and IS used the precursor to product ion transitions at m/z 631.8-->373.1, m/z 393.2-->147.1 and m/z 264.2-->58.1, respectively. The method was linear over the ranges 1.5-1000ng/mL for dexamethasone palmitate and 2.5-250ng/mL for dexamethasone with intra- and inter-day precisions of <10% and accuracies of 100+/-7%. The assay was applied to a clinical pharmacokinetic study involving the injection of dexamethasone palmitate to healthy volunteers.  相似文献   

17.
Vinorelbine is a semi-synthetic vinca alkaloid with demonstrated high activities against various types of advanced cancer. To support a clinical pharmacokinetic study, a simple, rapid and sensitive method to determine vinorelbine in human plasma was developed using reversed phase liquid chromatography (LC) coupled with electrospray ionization mass spectrometry/mass spectrometry (ESI-MS/MS). Vinorelbine and vinblastine (the internal standard) were extracted from human plasma by one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether. The chromatographic separation was achieved on a Spursil polar-modified C(18) column (50 mm×2.1 mm, 3 μm, Dikma Technologies) with an isocratic mobile phase of a 75:25 (v/v) acetonitrile-4 mmol/L ammonium formate (pH 3.0) mixture at a flow-rate of 0.4 mL/min. The MS/MS detection was performed in the positive ion multiple reaction monitoring (MRM) mode by monitoring the precursor→product ion transitions at m/z 779.4→122.0 and m/z 811.3→224.2 for vinorelbine and the internal standard, respectively. The assay was validated in the range 0.1-200 ng/mL (r>0.997), the lowest level of this range being the lower limit of quantification (LLOQ) based on 50 μL of plasma. The intra- and inter-day precisions were within 6.0%, while the accuracy was within ±4.7% of nominal values. Detection and quantification of both analytes within 2 min make this method suitable for high-throughput analyses. The method was successfully applied to evaluate the systemic pharmacokinetics of vinorelbine after a 20-min intravenous infusion of 25 mg/m(2) of vinorelbine to patients with metastatic breast cancer.  相似文献   

18.
A highly sensitive and specific quantitative assay for the determination of albuterol in human plasma, based on selected ion monitoring gas chromatography chemical ionization mass spectrometry, has been developed. The [MH]+ ions from the tri-TMS derivatives of albuterol (m/z 456) and the internal standard (2H3)albuterol (m/z 459), were assayed simultaneously by selected ion monitoring. The lower limit of quantitation is 0.25 ng ml-1 and the average assay precision (CV) for albuterol concentrations ranging from 0.25 ng ml-1 to 25 ng ml-1 is approximately 4%. This method is currently being employed for the routine quantitation of albuterol in plasma following the administration of doses therapeutically effective to man.  相似文献   

19.
The structures of intact choline phospholipids were determined by positive and negative ion mode fast atom bombardment mass spectrometry, tandem mass spectrometry, and B2/E and B/E constant linked scan mass spectrometry. The molecular weight of the choline lipid could be clearly determined by the appearance of [M + H]+ or [M + Na]+ in the positive ion mode and triplet ions, e.g., [M - 15]-, [M - 60]-, and [M - 86]-, in the negative ion mode. The structures of the triplet ions were assigned to [M - CH3]-, [M - HN(CH3)3]-, and [M - CH2 = CHN(CH3)3]-, respectively, by the MS/MS of each triplet ion, and the origin of the triplet ions was found as the matrix-ion adduct to the target molecule by using the B2/E linked scan technique. The polar group could be identified by the existence of ions indicating glycerophosphocholine and its cleavage products and by the presence of the triplet ions in the negative ion mode. Positional determination of the distribution of constituent fatty acyl groups was carried out by comparing the intensity of deacylated ions from positions 1 and 2 in the positive ion mode and of the ions produced by MS/MS of the triplet ions. From the mass number of the [RCOO]- ion which appeared in the negative ion mode, the molecular weight and degree of unsaturation of the fatty acyl group were determined. The position of double bond(s) in the acyl group was determined from the MS/MS of the [RCOO]- ion.  相似文献   

20.
A sensitive method for the determination of clarithromycin in plasma is described, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Samples were prepared using liquid-liquid extraction and separated on a Supelco Discovery C18 column with a mobile phase consisting of acetonitrile, methanol and acetic acid. Detection was performed by a PE SCIEX API 2000 mass spectrometer in the multiple reaction monitoring (MRM) mode (LC-MS-MS) using TurbolonSpray ionization and monitoring the transition of the protonated molecular ion for clarithromycin at m/z 748.5 (M+1) to the predominant product ion of m/z 158.2. The mean recovery of clarithromycin was 87.3%, with a lower limit of quantification of 2.95 ng/ml when using 0.3-ml plasma. This high-throughput method was used to quantify 230 samples per day, and is sufficiently sensitive to be employed in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号