首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.

Unnatural temporal and spatial distributions of wall shear stress in the anastomosis of distal bypass grafts have been identified as possible factors in the development of anastomotic intimal hyperplasia in these grafts. Distal bypass graft anastomoses with an autologus vein cuff (a Miller cuff) interposed between the graft and artery have been shown to alleviate the effects of intimal hyperplasia. In this study, pulsatile flow through models of a standard end-to-side anastomosis and a Miller cuff anastomosis are computed and the resulting wall shear stress and pressure distributions analysed. The results are inconclusive, and could be taken to suggest that the unnatural distributions of shear stress that do occur along the anastomosis floor may not be particularly important in the development of intimal hyperplasia. However, it seems more likely that the positive effects of the biological and material properties of the vein cuff, which are not considered in this study, somehow outweigh the negative effects of the shear stress distributions predicted to occur on the floor of the Miller-cuff graft.  相似文献   

2.
Unnatural temporal and spatial distributions of wall shear stress in the anastomosis of distal bypass grafts have been identified as possible factors in the development of anastomotic intimal hyperplasia in these grafts. Distal bypass graft anastomoses with an autologus vein cuff (a Miller cuff) interposed between the graft and artery have been shown to alleviate the effects of intimal hyperplasia. In this study, pulsatile flow through models of a standard end-to-side anastomosis and a Miller cuff anastomosis are computed and the resulting wall shear stress and pressure distributions analysed. The results are inconclusive, and could be taken to suggest that the unnatural distributions of shear stress that do occur along the anastomosis floor may not be particularly important in the development of intimal hyperplasia. However, it seems more likely that the positive effects of the biological and material properties of the vein cuff, which are not considered in this study, somehow outweigh the negative effects of the shear stress distributions predicted to occur on the floor of the Miller-cuff graft.  相似文献   

3.
The development of intimal hyperplasia at arterial bypass graft anastomoses is a major factor responsible for graft failure. A revised surgical technique, involving the incorporation of a small section of vein (vein cuff) into the distal anastomosis of PTFE grafts, results in an altered distribution of intimal hyperplasia and improved graft patency rates, especially for below-knee grafts. Numerical simulations have been conducted under physiological conditions to identify the flow behaviour in a typical cuffed bypass model and to determine whether the improved performance of the cuffed system can be accounted for by haemodynamic factors. The flow patterns at the cuffed anastomosis are significantly different to those at the conventional end-to-side anastomosis. In the former case, the flow is characterised by an expansive, low momentum recirculation within the cuff. Separation occurs at the graft heel, and at the cuff toe as the blood enters the recipient artery. Wall shear stresses in the vicinity of the cuff heel are low, but high shear stresses and large spatial gradients in the shearing force act on the artery floor during systole. In contrast, a less disturbed flow prevails and the floor shear stress distribution is less adverse in the conventional model. In conclusion, aspects of the anastomotic haemodynamics are worsened when the cuff is employed. The benefits associated with the cuffed grafts may be related primarily to the presence of venous material at the anastomosis. Therefore, caution is advised with regard to the use of PTFE grafts, pre-shaped to resemble a cuffed geometry.  相似文献   

4.
《Biorheology》1996,33(4-5):305-317
The motion of guanine particles was recorded by video to visualize transitional flow phenomena in models of a proximal side-to-end anastomosis. Close examination of successive video fields revealed that above a critical Reynolds number, particles were periodically shed into the graft from a vortex situated near the anastomosis heel, and this disturbed the flow patterns in the graft causing vortex shedding to occur near to the toe of the anastomosis. The images clearly demonstrated that periodic flow structures propagated distally along the graft for over 15 tube diameters from the proximal anastomosis. The frequency of the vortex shedding was found to increase with Reynolds number. Under pulsatile conditions, the primary vortex at the heel of the anastomosis became unstable during the deceleration phase of the flow cycle and particles were shed downstream into the graft. Although it was possible briefly to observe the characteristic banded structure in the bypass graft, the flow patterns were highly three-dimensional and were quickly broken up by the accelerating flow. Dynamic flow visualization using guanine particles was found to be a complementary technique to particle tracer flow visualization and was highly effective in identifying transitional flow phenomena and the mass transport mechanisms associated with them.  相似文献   

5.
目的血管搭桥术后的内膜增生往往导致手术失败,而内膜增生与搭桥血管内的流场密切相关,为改善搭桥血管中的流场结构,作者设计了偏心搭桥手术方法,利用计算机数值模拟技术,探索偏心搭桥和传统搭桥血管中流场的变化,为血管搭桥方法提供优化设计方案。方法16只犬随机分为偏心搭桥组和传统搭桥组进行血管搭桥,测定搭桥前后血管几何数据,搭桥后近心端及远心端吻合口血流量和血压。按测定的血管几何数据,FLUENT 6.2模拟搭桥血管内的流场。结果偏心搭桥近心端和远心端吻合口不在同一平面。传统搭桥中,主体动脉远心端吻合口对应面处存在一个较低壁面剪切应力(WSS)区域及流体停滞点,离脚跟较近的一部分流体会形成涡漩,血流进入主体动脉后,还会表现出迪恩涡二次流;偏心搭桥中,主体动脉吻合口对应面上的低WSS区域和流体停滞点消失,血流接触到吻合口底面后,以切向旋转的方式改变其流动方向,不会形成涡漩,且当血流进入主体动脉后,立即发生螺旋流态且能持续很长一段。结论偏心搭桥能够产生血液旋动流,显著增加远心端血流量、提高WSS。  相似文献   

6.
Vortex shedding at vascular anastomoses were investigated in vitro using a 20 MHz pulsed-wave Doppler velocimeter. Centreline velocity measurements were made at various axial distances in simplified polyurethane models of proximal and distal end-to-side anastomoses of angles 15, 30, 45, 60 and 80 degrees using pulsatile flow waveforms similar to those in femoropopliteal bypass grafts. The in-phase and quadrature Doppler signals were recorded and the maximum frequency waveform, averaged over 64 cycles, was obtained using short-time Fourier transform. A fourth-order Butterworth low-pass filter was employed to separate the vortex velocity signal from the convective velocity. The vortex signal envelope was calculated using a Hilbert transform method and the vortex amplitude was taken as the maximum of this envelope. The results show that higher vortex amplitude were found in the proximal anastomoses and under resting flow conditions. Although the vortex amplitudes generally increased with angles of anastomosis, they were found to be higher in the 60 degrees than in the 80 degrees proximal anastomosis. The vortex structures were investigated using spectrograms and these show prominent features at 40-50 Hz indicative of the short-duration oscillatory signals during the decelerative phase of systole expected from the passage of vortices. The study indicates that flow disturbances due to vortex shedding may be a common feature in femoropopliteal bypass grafts.  相似文献   

7.
Arterio-venous grafts (AVGs), the second best option as long-term vascular access for hemodialysis, face major issues of stenosis mainly due to development of intimal hyperplasia at the venous anastomosis which is linked to unfavorable hemodynamic conditions. We have investigated computationally the utility of a coupled sequential venous anastomotic design to replace conventional end-to-side (ETS) venous anastomosis, in order to improve the hemodynamic environment and consequently enhance the patency of AVGs. Two complete vascular access models with the conventional and the proposed venous anastomosis configurations were constructed. Three-dimensional, pulsatile blood flow through the models was simulated, and wall shear stress (WSS)-based hemodynamic parameters were calculated and compared between the two models. Simulation results demonstrated that the proposed anastomotic design provides: (i) a more uniform and smooth flow at the ETS anastomosis, without flow impingement and stagnation point on the artery bed and vortex formation in the heel region of the ETS anastomosis; (ii) more uniform distribution of WSS and substantially lower WSS gradients on the venous wall; and (iii) a spare route for the blood flow to the vein, to avoid re-operation in case of stenosis. The distinctive hemodynamic advantages observed in the proposed anastomotic design can enhance the patency of AVGs.  相似文献   

8.
Pulsatile flows in glass models simulating fusiform and lateral saccular aneurysms were investigated by a flow visualization method. When resting fluid starts to flow, the initial fluid motion is practically irrotational. After a short period of time, the flow began to separate from the proximal wall of the aneurysm. Then the separation bubble or vortex grew rapidly in size and filled the whole area of the aneurysm circumferentially. During this period of time, the center of the vortex moved from the proximal end to the distal point of the aneurysm. The transient reversal flow, for instance, which may occur at the end of the ejection period, passed between the wall of the aneurysm and the centrally located vortex. When the rate and pulsatile frequency of flow were high, the vortex broke down into highly disturbed flow (or turbulence) at the distal portion of the aneurysm. The same effect was observed when the length of the aneurysm was increased. A reduction in pulsatile amplitude made the flow pattern close to that in steady flow. A finite element analysis was made to obtain velocity and pressure fields in pulsatile flow through a tube with an axisymmetric expansion. Calculations were performed with the pulsatile flows used in the visualization experiment in order to study the effects of change in the pulsatile wave form by keeping the time-mean Reynolds number and Womersley's parameter unchanged. Calculated instantaneous patterns of velocity field and stream lines agreed well with the experimental results. The appearance and disappearance of the vortex in the dilated portion and its development resulted in complex distributions of pressure and shear fields. Locally minimum and maximum values of wall shear stress occurred at points just upstream and downstream of the distal end of the expansion when the flow rate reached its peak.  相似文献   

9.
Numerical simulations of pulsatile flow in coronary arteries which take into account the curvature associated with the bending of arteries over the surface of the heart are presented for resting, excited and drug induced states. The study was motivated by reported observations of atherosclerotic plaque localization on the inner curvature of coronary arteries. The simulated flow field appears quasi-steady under resting conditions with wall shear stress always highest on the outside wall and only a single secondary flow vortex in the half tube. However, reversal of wall shear stress direction at the inside wall does occur under resting flow conditions and this is not a quasi-steady characteristic. The flow field is markedly unsteady under excited conditions with wall shear stress sometimes peaking on the inside wall and an increase in the magnitude of wall shear stress reversal on the inside wall. However, only a single secondary flow vortex in the half tube is observed. Implications of the simulations for the role of fluid mechanics in coronary artery atherosclerosis are also discussed.  相似文献   

10.
Rotating wall vessel bioreactors have been proposed as a means of controlling the fluid dynamic environment during long-term culture of mammalian cells and engineered tissues. In this study, we show how the delivery of oxygen to cells in an annular flow bioreactor is enhanced by the forced convective transport afforded by Taylor vortex flows. A fiberoptic oxygen probe with negligible lag time was used to measure the dissolved oxygen concentration in real time and under carefully controlled aeration conditions. From these data, the overall mass transfer coefficients were calculated and mass transport correlations determined under laminar Couette flow conditions and discrete Taylor vortex flow regimes, including laminar, wavy, and turbulent flows. While oxygen transport in Taylor vortex flows was significantly greater, and the available oxygen exceeded that consumed by murine fibroblasts in free suspension, the proportion of cells that remained viable decreased with increasing Reynolds number (101.8 < Rei < 1018), which we attribute to the action of fluid shear stresses on the cells as opposed to any limitation in mass transport. Nevertheless, the results of this study suggest that laminar Taylor-vortex flow regimes provide an effective means of maintaining the levels of oxygen transport required for long-term cell culture.  相似文献   

11.
The aim of our study is to investigate with computational fluid dynamics (CFD) whether different arterial anastomotic geometries result in a different hemodynamics at the arterial (AA) and venous anastomosis (VA) of hemodialysis vascular access grafts. We have studied a 6mm graft (CD) and a 4-7 mm graft (TG). A validated three-dimensional CFD model is developed to simulate flow in the two graft types. Only the arterial anastomosis (AA) geometry differs. The boundary conditions applied are a periodic velocity signal at the arterial inlet and a periodic pressure wave at the venous outlet. Flow rate is set to 1,000 ml/min. The time dependent Navier-Stokes equations are solved. Wall shear stress (WSS), wall shear stress gradient (WSSG) and pressure gradient (PG) are calculated. Anastomotic flow is asymmetric although the anastomosis geometry is symmetric. The hemodynamic parameters, WSS, WSSG and PG, values at the suture line of the arterial anastomosis of the TG are at least twice as much as in the CD. Comparing the parameters at the two AA indicate that little flow rate increase introduces the risk of hemolysis in the TG whereas the CD is completely free of hemolysis. The hemodynamic parameter values at the venous anastomosis of the CD are 24 till 35% higher compared to the values of the TG. WSS values (> 3 Pa) in the VA are in the critical range for stenosis development in both graft geometries. The zones where the parameters reach extreme values correspond to the locations where intimal hyperplasia formation is reported in literature. In all anastomoses, the hemodynamic parameter levels are in the range where leucocytes and platelets get activated. Our simulations confirm clinical results where TG did not show a better outcome when compared to the CD.  相似文献   

12.
The interrupted suture technique is most commonly used for microsurgical vascular anastomosis. For several reasons (e.g., exposure of suture material to blood, time needed), many attempts have been made to find other solutions. This article describes a new means of performing a microsurgical vascular anastomosis. The aim of this study was to show the feasibility and possible advantages of this new technique. The basic components at work here are a modified cuff and electrically generated heat used to unite the vessel walls. In this way, both endothelial layers are adapted without manipulating the inside of the vessel or leaving behind foreign matter. Various energy/coagulation time settings were used to perform arterial anastomoses (n = 42) in an isogeneic abdominal aorta interposition model in the rat. The quality of anastomosis was evaluated at days 1, 10, 21, and 120. Immediately after the welding process all anastomoses (n = 42) were patent. No stenosis was found at any observation time. Anastomosis time ranged from 3 to 18 minutes (average, 11 minutes). This new technique permits a vascular anastomosis to be performed easily and reliably with a high patency rate. With this technique, the authors are convinced that a skilled surgeon can create a high-quality anastomosis in a fraction of the time needed to sew an anastomosis.  相似文献   

13.
14.
Wall shear has been widely implicated as a contributing factor in the development of intimal hyperplasia in the anastomoses of chronic arterial bypass grafts. Earlier studies have been restricted to either: (1) in vitro or computer simulation models detailing the complex hemodynamics within an anastomosis without corresponding biological responses, or (2) in vivo models that document biological effects with only approximate wall shear information. Recently, a specially designed pulse ultrasonic Doppler wall shear rate (PUDWSR) measuring device has made it possible to obtain three near-wall velocity measurements nonintrusively within 1.05 mm of the vessel luminal surface from which wall shear rates (WSRs) were derived. It was the purpose of this study to evaluate the effect of graft caliber, a surgically controllable variable, upon local hemodynamics, which, in turn, play an important role in the eventual development of anastomotic hyperplasia. Tapered (4-7 mm I.D.) 6-cm-long grafts were implanted bilaterally in an end-to-side fashion with 30 deg proximal and distal anastomoses to bypass occluded common carotid arteries of 16 canines. The bypass grafts were randomly paired in contralateral vessels and placed such that the graft-to-artery diameter ratio, DR, at the distal anastomosis was either 1.0 or 1.5. For all grafts, the average Re was 432 +/- 112 and the average Womersley parameter, alpha, was 3.59 +/- 0.39 based on artery diameter. There was a sharp skewing of flow toward the artery floor with the development of a stagnation point whose position varied with time (up to two artery diameters) and DR (generally more downstream for DR = 1.0). Mean WSRs along the artery floor for DR = 1.0 and 1.5 were found to range sharply from moderate to high retrograde values (589 s-1 and 1558 s-1, respectively) upstream to high antegrade values (2704 s-1 and 2302 s-1, respectively) immediately downstream of the stagnation point. Although there were no overall differences in mean and peak WSRs between groups, there were significant differences (p < 0.05) in oscillatory WSRs as well as in the absolute normalized mean and peak WSRs between groups. There were also significant differences (p < 0.05) in mean and peak WSRs with respect to axial position along the artery floor for both DR cases. In conclusion, WSR varies widely (1558 s-1 retrograde to 2704 s-1 antegrade) within end-to-side distal graft anastomoses, particularly along the artery floor, and may play a role in the development of intimal hyperplasia through local alteration of mass transport and mechano-signal transduction within the endothelium.  相似文献   

15.

Purpose  

Coronary artery bypass graft (CABG) surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences in the patency rates of the two types of anastomosis. The purpose of this paper is to non-invasively quantify hemodynamic parameters, such as mass flow and wall shear stress (WSS), in end-to-side and side-to-side anastomoses of patients with CABG using computational fluid dynamics (CFD).  相似文献   

16.
How TV  Fisher RK  Hoedt MT  Brennan J  Harris PL 《Biorheology》2002,39(3-4):461-465
Clinical evidence suggests that the development of myointimal hyperplasia in prosthetic femorodistal bypass grafts may be reduced by the interposition of a cuff of autologous vein between the graft and the recipient artery. Previous experimental work has shown that some of the benefits may be attributed to the geometry of the cuffed anastomosis. Since the distal anastomosis in vivo is often non-planar we have carried out a preliminary study in a model where the graft is at an angle of 45 degrees to the anterior-posterior plane of the anastomosis. This out-of-plane angulation produces highly asymmetric flow patterns in the anastomosis with significant flow separation on the ipsilateral side of the cuff. In the proximal and distal outflow, however, the velocity vectors show significant helical motion with temporal instability in the distal outflow.  相似文献   

17.
The aim of this work is to develop a unique in vitro set-up in order to analyse the influence of the shear thinning fluid-properties on the flow dynamics within the bulge of an abdominal aortic aneurysm (AAA). From an experimental point of view, the goals are to elaborate an analogue shear thinning fluid mimicking the macroscopic blood behaviour, to characterise its rheology at low shear rates and to propose an experimental device able to manage such an analogue fluid without altering its feature while reproducing physiological flow rate and pressure, through compliant AAA. Once these experimental prerequisites achieved, the results obtained in the present work show that the flow dynamics is highly dependent on the fluid rheology. The main results point out that the propagation of the vortex ring, generated in the AAA bulge, is slower for shear thinning fluids inducing a smaller travelled distance by the vortex ring so that it never impacts the anterior wall in the distal region, in opposition to Newtonian fluids. Moreover, scalar shear rate values are globally lower for shear thinning fluids inducing higher maximum stress values than those for the Newtonian fluids. Consequently, this work highlights that a Newtonian fluid model is finally inadequate to obtain a reliable prediction of the flow dynamics within AAA.  相似文献   

18.
Blood flow dynamics in saccular aneurysm models of the basilar artery   总被引:1,自引:0,他引:1  
Blood flow dynamics under physiologically realistic pulsatile conditions plays an important role in the growth, rupture, and surgical treatment of intracranial aneurysms. The temporal and spatial variations of wall pressure and wall shear stress in the aneurysm are hypothesized to be correlated with its continuous expansion and eventual rupture. In addition, the assessment of the velocity field in the aneurysm dome and neck is important for the correct placement of endovascular coils. This paper describes the flow dynamics in two representative models of a terminal aneurysm of the basilar artery under Newtonian and non-Newtonian fluid assumptions, and compares their hemodynamics with that of a healthy basilar artery. Virtual aneurysm models are investigated numerically, with geometric features defined by beta = 0 deg and beta = 23.2 deg, where beta is the tilt angle of the aneurysm dome with respect to the basilar artery. The intra-aneurysmal pulsatile flow shows complex ring vortex structures for beta = 0 deg and single recirculation regions for beta = 23.2 deg during both systole and diastole. The pressure and shear stress on the aneurysm wall exhibit large temporal and spatial variations for both models. When compared to a non-Newtonian fluid, the symmetric aneurysm model (beta = 0 deg) exhibits a more unstable Newtonian flow dynamics, although with a lower peak wall shear stress than the asymmetric model (beta = 23.2 deg). The non-Newtonian fluid assumption yields more stable flows than a Newtonian fluid, for the same inlet flow rate. Both fluid modeling assumptions, however, lead to asymmetric oscillatory flows inside the aneurysm dome.  相似文献   

19.
The distally based radial artery forearm flap has become our workhorse flap for hand and finger coverage, relying on reversed or retrograde venous outflow through the venae comitantes. Free-flap transfer, however, has been used by us only with antegrade venous anastomoses. This study was intended to determine if a single retrograde venous anastomosis would be adequate for flap viability. Six groups of saphenous flaps were developed in New Zealand White rabbits. In situ flaps compared antegrade with retrograde venous outflow in groups 1 and 2. Microvascular venous anastomoses with antegrade or retrograde outflow were compared in groups 3 and 4. Free-flap transfer with antegrade or retrograde venous outflow was compared in groups 5 and 6. No significant differences in survival was found between groups 1 and 2. A significant difference in survival (p = 0.025) was found between groups 3 and 4, but technical differences make these groups incomparable. Significantly better survival (p = 0.014, chi-squared test) was found in group 5 with antegrade outflow versus group 6 with retrograde outflow.  相似文献   

20.
We consider the effect of geometrical configuration on the steady flow field of representative geometries from an in vivo anatomical data set of end-to-side distal anastomoses constructed as part of a peripheral bypass graft. Using a geometrical classification technique, we select the anastomoses of three representative patients according to the angle between the graft and proximal host vessels (GPA) and the planarity of the anastomotic configuration. The geometries considered include two surgically tunneled grafts with shallow GPAs which are relatively planar but have different lumen characteristics, one case exhibiting a local restriction at the perianastomotic graft and proximal host whilst the other case has a relatively uniform cross section. The third case is nonplanar and characterized by a wide GPA resulting from the graft being constructed superficially from an in situ vein. In all three models the same peripheral resistance was imposed at the computational outflows of the distal and proximal host vessels and this condition, combined with the effect of the anastomotic geometry, has been observed to reasonably reproduce the in vivo flow split. By analyzing the flow fields we demonstrate how the local and global geometric characteristics influences the distribution of wall shear stress and the steady transport of fluid particles. Specifically, in vessels that have a global geometric characteristic we observe that the wall shear stress depends on large scale geometrical factors, e.g., the curvature and planarity of blood vessels. In contrast, the wall shear stress distribution and local mixing is significantly influenced by morphology and location of restrictions, particular when there is a shallow GPA. A combination of local and global effects are also possible as demonstrated in our third study of an anastomosis with a larger GPA. These relatively simple observations highlight the need to distinguish between local and global geometric influences for a given reconstruction. We further present the geometrical evolution of the anastomoses over a series of follow-up studies and observe how the lumen progresses towards the faster bulk flow of the velocity in the original geometry. This mechanism is consistent with the luminal changes in recirculation regions that experience low wall shear stress. In the shallow GPA anastomoses the proximal part of the native host vessel occludes or stenoses earlier than in the case with wide GPA. A potential contribution to this behavior is suggested by the stronger mixing that characterizes anastomoses with large GPA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号