首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The glucuronide and sulfate conjugates of benzene metabolites as well as muconic acid and pre-phenyl- and phenylmercapturic acids were separated by ion-pairing HPLC. The HPLC method developed was suitable for automated analysis of a large number of tissue or excreta samples. p-Nitrophenyl [14C]glucuronide was used as an internal standard for quantitation of these water-soluble metabolites. Quantitation was verified by spiking liver tissue with various amounts of phenylsulfate or glucuronides of phenol, catechol, or hydroquinone and analyzing by HPLC. Values determined by HPLC analysis were within 10% of the actual amount with which the liver was spiked. The amount of metabolite present in urine following exposure to [3H]benzene was determined using p-nitrophenyl [14C]glucuronide as an internal standard. Phenylsulfate was the major water-soluble metabolite in the urine of F344 rats exposed to 50 ppm [3H]benzene for 6 h. Muconic acid and an unknown metabolite which decomposed in acidic media to phenylmercapturic acid were also present. Liver, however, contained a different metabolic profile. Phenylsulfate, muconic acid, and pre-phenylmercapturic acids as well as an unknown with a HPLC retention time of 7 min were the major metabolites in the liver. This indicates that urinary metabolite profiles may not be a true reflection of what is seen in individual tissues.  相似文献   

2.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

3.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 microg/ml for iohexol and iothalamate, 5 to 40 microg/ml for PAH and 2.5 to 40 microg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.  相似文献   

4.
A sensitive and specific high-performance liquid chromatographic–tandem mass spectrometric (HPLC–MS–MS) method was developed for the determination of 3-hydroxypropylmercapturic acid (3-HPMA) in human urine. Samples were extracted using ENV+ cartridges and then injected onto a C8 Superspher Select B column with acetonitrile and formic acid as eluent (5:95, v/v). N-Acetylcysteine was used as internal standard for HPLC–MS–MS. Linearity was given in the tested range of 50–5000 ng/ml urine. The limit of quantification was 50 ng/ml. Precision, as C.V., in the tested range of 50–5000 ng/ml was 1.47–6.04%. Accuracy ranged from 87 to 114%. 3-HPMA was stable in human urine at 37°C for 24 h. The method was able to quantify 3-HPMA in urine of non-smokers and smokers.  相似文献   

5.
A high-performance liquid chromatographic (HPLC) assay suitable for the analysis of the enantiomers of ketoprofen (KT), a 2-arylpropionic acid (2-APA) non-steroidal antiinflammatory drug (NSAID), in plasma and urine was developed. Following the addition of racemic fenoprofen as internal standard (I.S.), plasma containing the KT enantiomers and I.S. was extracted by liquid-liquid extraction at an acidic pH. After evaporation of the organic layer, the drug and I.S. were reconstituted in mobile phase and injeted into the HPLC system. The enantiomers were separated at ambient temperature on a commercially available 250 × 4.3 mm amylose carbamate-packed chiral column (Chiralpak AD) column with hexane-isopropyl alcohol-trifluoroacetic acid (80:19.9:0.1, v/v/v) as the mobile phase pumped at 1.0 ml/min. The enantiomers of KT were quantified by ultraviolet detection with the wavelength set at 254 nm. The assay described allows for the direct quantification of KT enantiomers without pre-column derivatization, and is suitable for clinical studies of KT enantiomers in human plasma and urine after administration of therapeutic doses.  相似文献   

6.
A gas chromatography-mass spectrometry method for measurement of the main urinary metabolites of benzene, namely, phenol, catechol, hydroquinone, 1,2,4-trihydroxybenzene (trihydroxybenzene), t,t-muconic acid (muconic acid), and S-phenylmercapturic acid (phenylmercapturic acid), is reported. The method is considerably simpler than existing assays. It was applied to urine from benzene-exposed subjects and controls from Shanghai, China. When subjects were divided into controls (n = 44), those exposed to 31 ppm benzene (n = 19), Spearman correlations with exposure category were >/= 0.728 (p < 0.0001) for all metabolites except trihydroxybenzene. When exposed subjects were compared on an individual basis, all metabolites, including trihydroxybenzene, were significantly correlated with benzene exposure (Pearson r >/= 0.472, p /= 0.708, p < 0.0001). Ratios of individual metabolite levels to total metabolite levels provided evidence of competitive inhibition of CYP 2E1 enzymes leading to increased production of phenol, catechol, and phenylmercapturic acid at the expense of hydroquinone, trihydroxybenzene, and muconic acid. Since all metabolites were detected in all control subjects, the method can be applied to persons exposed to environmental levels of benzene.  相似文献   

7.
A method is described for the qualiitative and quantitative determination of phenylbutazone and oxyphenbutazone in horse urine and plasma samples viewing antidoping control. A horse was administered intravenously with 3 g of phenylbutazone. For the qualitative determination, a screening by HPLC was performed after acidic extraction of the urine samples and the confirmation process was realized by GC-MS. Using the proposed method it was possible to detect phenylbutazone and oxyphenbutazone in urine for up to 48 and 120 h, respectively. For the quantitation of these drugs the plasma was deproteinized with acetonitrile and 20 gml were injected directly into the HPLC system equipped with a UV detector and LiChrospher RP-18 column. The mobile phase used was 0.01 M acetic acid in methanol (45:55, v/v). The limit of detection was 0.5 μg/ml for phenylbutazone and oxyphenbutazone and the limit of quantitation was 1.0 μg/ml for both drugs. Using the proposed method it was possible to quantify phenylbutazone up to 30 h and oxyphenbutazone up to 39 h after administration.  相似文献   

8.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated, according to U.S. Food and Drug Administration guidance, for the simultaneous determination of phenylmercapturic acid, benzylmercapturic acid and o-methylbenzyl mercapturic acid in human urine as biomarkers of exposure to benzene, toluene and xylenes (BTX). After solid phase extraction and LC separation, samples were analyzed by a triple-quadrupole mass spectrometer operated in negative ion mode, using isotope-labeled analogs as internal standards (ISs). The method meets all the validation criteria required. The limits of detection of the three analytes, ranging from 0.30 to 0.40microgl(-1), and the high throughput make the method suitable for the routine biological monitoring of co-exposure to BTX both in the occupational and environmental settings. The validated method was applied to assess exposure to BTX in a group of 354 urban traffic wardens.  相似文献   

9.
An HPLC method has been developed for the separation and the determination of caffeine and its metabolites in urine samples using a one extraction–analysis run and UV detection. The compounds were extracted by liquid–liquid extraction using chloroform–isopropylalcohol (85:15, v/v). Chromatographic separation was accomplished on an ODS analytical column with a mobile phase containing 0.05% acetic acid/methylalcohol (92.5:7.5, v/v). Compounds were monitored at 280 nm. The method was validated for the determination of AFMU, 1X, 1U, 17X and 17U caffeine metabolites required to assess the metabolic activity of the enzymes subject to in vivo caffeine testing. The validated assay was applied to urine samples from ten healthy volunteers. The method was proved to be suitable to assess simultaneously the enzymatic activity of cytochrome P450 CYP1A2 and CYP2A6, as well as N-acetyltransferase and xanthine oxidase.  相似文献   

10.
A sensitive and selective reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL; CrEL), which requires only microvolumes (20 μl) of plasma, has been developed and validated. The procedure is based on saponification of CrEL in alcoholic KOH, followed by extraction of the released fatty acid ricinoleic acid with chloroform and derivatization with 1-naphthylamine. Margaric acid was used as the internal standard. The products are separated using an HPLC system consisting of an analytical column packed with Spherisorb ODS-1 material and a mobile phase of methanol-acetonitrile-10 mM potassium phosphate buffer pH 7.0 (72:13:15, v/v). Detection was executed by UV absorption at 280 nm. The lower limit of quantitation and the lower limit of detection in plasma are 0.01 and 0.005% (v/v) of CrEL, respectively. The percentage deviation and precision of the procedure, over the validated concentration range of 0.01 to 1.0% (v/v) of CrEL in plasma, are ≤8.0% and ≤ 6.6%, respectively. Compared to the previously described bioassay, the presented HPLC method possesses superior sensitivity and reliability. Preliminary pharmacokinetic studies of CrEL in mice and patients receiving paclitaxel formulated in CrEL have demonstrated the applicability of the presented assay.  相似文献   

11.
A simple and rapid solid-phase microextraction method was developed for the enantioselective analysis of ibuprofen in urine. The sampling was made with a polydimethylsiloxane-divinylbenzene coated fiber immersed in the liquid sample. After desorptioning from the fiber, ibuprofen enantiomers were analyzed by HPLC using a Chiralpak AD-RH column and UV detection. The mobile phase was made of methanol-pH 3.0 phosphoric acid solution (75:25, v/v), at a flow rate of 0.45 mL/min. The mean recoveries of SPME were 19.8 and 19.1% for (-)-R-ibuprofen and (+)-(S)-ibuprofen, respectively. The method was linear at the range of 0.25-25 microg/mL. Within-day and between-day assay precision and accuracy were below 15% for both ibuprofen enantiomers at concentrations of 0.75, 7.5 and 20 microg/mL. The method was tested with urine quality control samples and human urine fractions after administration of 200 mg rac-ibuprofen.  相似文献   

12.
A novel high-performance liquid chromatography (HPLC) assay for the estimation of formoterol in urine samples was developed and validated. A solid phase extraction (SPE) using Oasis HLB was optimised to isolate formoterol from a urine matrix followed by HPLC with UV detection. This extraction procedure concentrated the final analyte forty times so that UV detection can be used to determine even a low concentration of formoterol in urine samples. The urinary assay was performed in accordance with FDA and ICH regulations for the validation of bioanalytical samples. The samples were injected onto a C18 Spherisorb (250 mm x 4.6 mm x 5 microm) analytical column maintained at 30 degrees C. The mobile phase consisted of 5 mM of potassium dihydrogen orthophosphate buffer (adjusted to pH 3 with ortho phosphoric acid):acetonitrile (ACN) (70:30, v/v), and the formoterol peak was detected at wavelength 214 nm. The extraction recovery of formoterol from the urine sample was >95%. The calibration curve was linear (r2=0.99) over formoterol concentrations ranging from 1.5 to 25 ng/mL (n=6). The method had an accuracy of >92% and intra and inter-day precision CV% of <3.9% and <2.2%, respectively, at three different concentrations low, medium and high (10, 15, 20 ng/mL). The limit of quantification (LOQ) for formoterol was found to be 1.50 ng/mL. The accuracy and precision at the LOQ level were 95% and %CV <3.7% (n=10), respectively. The method reported is simple, reliable, precise, and accurate and has the capacity to be used for determination of formoterol in urine samples.  相似文献   

13.
Doxepin is a tricyclic antidepressant marketed as an irrational mixture of cis- and trans-geometric isomers in the ratio of 15:85. A convenient high-performance liquid chromatographic (HPLC) procedure for simultaneous quantitation of geometric isomers of doxepin and N-desmethyldoxepin in plasma and urine is described. The HPLC procedure employed a normal phase system with a silica column and a mobile phase consisting of hexane-methanol-nonylamine (95:5:0.3, v/v/v), a UV detector and nortriptyline as the internal standard. The liquid-liquid extraction solvent was a mixture of n-pentane-isopropanol (95:5, v/v). The limit of quantitation was 1 ng/ml for each isomer. The calibration curves were linear over the ranges 1–200 ng/ml (plasma) and 1–400 ng/ml (urine). In plasma, the accuracy (mean±S.D.) (97.53±1.67%) and precision (3.89±1.65%) data for trans-doxepin were similar to corresponding values for urine, i.e., 97.10±2.40 and 3.82±1.14%. Accuracy and precision data for trans-N-desmethyldoxepin in plasma were 97.57±2.06 and 4.38±3.24%, and in urine were 97.64±3.32 and 5.26±1.83%, respectively. Stability tests under three different conditions of storage indicated no evidence of degradation. The recovery of doxepin was 61–64% from plasma and 63–68% from urine. The method has been applied to analyses of plasma and urine samples from human volunteers and animals dosed with doxepin.  相似文献   

14.
A rapid, selective and highly sensitive reversed-phase high-performance liquid chromatography (HPLC) method was developed for the determination of levosulpiride, 5-(aminosulfonyl)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-2-methoxy benzamide, in human serum and urine. The method involved the extraction with a dichloromethane followed by back-extraction into 0.025 M sulfuric acid. HPLC analysis was carried out using reversed-phase isocratic elution with a Luna C(18)(2) 5 microm column, a mobile phase of acetonitrile-0.01 M potassium hydrogen phosphate (30:70, v/v, adjusted to pH 8.5 with triethylamine), and a fluorescence detector with excitation at 300 nm and emission at 365 nm. The chromatograms showed good resolution and sensitivity and no interference of human serum and urine. The calibration curves were linear over the concentration range 0.25-200 ng/ml for serum and 0.2-20 microg/ml for urine with correlation coefficients greater than 0.997. Intra- and inter-day assay precision and accuracy fulfilled the international requirements. The mean absolute recovery for human serum was 89.8+/-3.7%. The lower limits of quantitation in human serum and urine were 0.25 ng/ml and 0.2 microg/ml, respectively, which were sensitive enough for pharmacokinetic studies. Stability studies showed that levosulpiride in human serum and urine was stable during storage, or during the assay procedure. This method was successfully applied to the study of pharmacokinetics of levosulpiride in human volunteers following a single oral administration of levosulpiride (25 mg) tablet.  相似文献   

15.
A column-switching HPLC method using an internal-surface phenylboronic acid precolumn for the selective extraction of β-blockers from biological fluids has been developed. Filtered urine and plasma samples (50 μl) were injected onto the precolumn equilibrated with methanol-0.05 M disodium hydrogenphosphate (5:95, v/v). After the precolumn had been washed breifly, the selectively retained β-blockers were eluted with methol-0.05 M phosphate buffer (pH 2.0) and transferred to a reversed-phase analytical column, on which they were then separated. Even after exposure to at least 160 injections of non-treated urine and plasma samples, the retention efficiency of the precolumn was maintained with no increase in back pressure. Quantitative recoveries and good reproducibility were demonstrated with pindolol.  相似文献   

16.
We have developed a sensitive and reproducible high performance liquid chromatography (HPLC)-UV method for the quantification of the p38 MAPkinase inhibitor SB202190 in serum, kidney homogenates and urine samples. Liquid-liquid extraction of SB202190 from the samples was performed using diethylether after adding a derivative of SB202190 as internal standard (I.S.). Chromatography was carried out using a C8 reversed-phase column with an isocratic mobile phase consisting of acetonitrile-water-trifluoroacetic acid (30:70:0.1, v/v/v; pH 2.0). Both drug and I.S. were measured at 350 nm and eluted at 5.0 and 10.6 min, respectively. Peak-height ratios of the drug and the I.S. were used for the quantification of SB202190 from the different matrixes. The limit of quantitation of SB202190 in serum, kidney and urine were 0.25 microg/ml, 1 microg/g and 1 microg/ml, respectively. The average recoveries were 74, 75 and 92% in serum, kidney and urine, respectively. The intra- and inter-day precision (% CV) and accuracy (% bias) were below 15% for all concentrations. The method was successfully applied for a pharmacokinetic study of SB202190 in rats.  相似文献   

17.
An HPLC method for determining a flavonoid naringin and its metabolite, naringenin, in human urine is presented for application to the pharmacokinetic study of naringin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using hesperidin for naringin or hesperetin for naringenin as internal standard and solid-phase extraction using a strong anion exchanger, Sep-Pak Accell QMA cartridge. The HPLC assay was carried out using an Inertsil ODS-2 column (250×4.6 mm I.D., 5 μm particle size). The mobile phases were acetonitrile–0.1 M ammonium acetate–acetic acid (18:81:1, v/v; pH 4.7) for naringin and acetonitrile–0.1 M ammonium acetate–triethylamine (25:75:0.05; v/v; pH 8.0) for naringenin. The flow-rate was 1.0 ml min−1. The analyses were performed by monitoring the wavelength of maximum UV absorbance at 282 nm for naringin and at 324 nm for naringenin. The lower limits of quantification were ca. 25 ng/ml for naringin and naringenin with R.S.D. less than 10%. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 5 ng for naringin and 1 ng for naringenin. A preliminary experiment to investigate the urinary excretion of naringin, naringenin and naringenin glucuronides after oral administration of 500 mg of naringin to a healthy volunteer demonstrated that the present method was suitable for determining naringin and naringenin in human urine.  相似文献   

18.
A high-performance liquid chromatographic (HPLC) method was developed using solid-phase extraction, o-phthalaldehyde (OPA) derivatization and fluorescence detection for the determination of the direct thrombin inhibitor bivalirudin in human plasma and urine. The use of this assay will facilitate the study of the pharmacodynamics of bivalirudin in studies of special patient populations. A C(18) bioanalytical column at a flow rate of 1 ml/min with an aqueous trifluoroacetic acid (0.1% TFA in deionized water, pH 2.2, v/v) mobile phase and methanol gradient was used. The assay demonstrated linearity from 3 to 20 microg/ml bivalirudin in plasma, with a detection limit of 1 microg/ml. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of bivalirudin in patients undergoing percutaneous coronary interventions (PCIs).  相似文献   

19.
The aim of this study was to develop an analytical method for free and conjugated 3-methoxy-4-hydroxy-phenylethyleneglycol (MHPG) in urine. After hydrolysis of the conjugated forms, the urinary MHPG was purified by solid-phase extraction on anion exchanger and eluted with a water-methanol (1:1, v/v) mixture. After addition of ethyl acetate to the eluate and back-extraction into acetic acid, the aqueous phase was separated on a C18 column by HPLC and detected amperometrically. The results obtained from forty healthy human subjects were compared with the literature values. The precision and accuracy of the assay were studied using 4-methoxy-3-hydroxyphenylethyleneglycol (iso-MHPG) as internal standard.  相似文献   

20.
A simple, sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3,000 mass spectrometer was equipped with a TurboIonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100 ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput of urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号