首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Background

There is a need for simple tools such as the M.tuberculosis specific IFN-γ release assays (IGRA) to improve diagnosis of M.tuberculosis-infection in children. The aim of the study was to evaluate the performance of an IP-10 and IL-2 based tests for the diagnosis of M.tuberculosis-infection in recently exposed children from Nigeria.

Methodology and Principal Findings

Samples were obtained from 59 children at high risk of infection with M.tuberculosis (contacts of adults with smear and culture-positive tuberculosis) and 61 at low risk (contacts of smear-negative/culture-positive tuberculosis or community controls). IP-10 and IL-2 was measured in plasma after stimulation of whole-blood with M.tuberculosis specific antigens and mitogen. Previously developed criteria for positive IP-10 and IL-2 tests were used and the diagnostic performances of the IP-10 and IL-2 tests were compared with the Quantiferon In-Tube (QFT-IT) and the Tuberculin Skin Tests (TST). In response to M.tuberculosis specific antigens, the high-risk children expressed significantly higher levels of IP-10 (1358 pg/ml[IQR 278–2535 pg/ml]) and IL-2 (164 pg/ml[11–590 pg/ml]) than low risk groups 149 pg/ml(25–497 pg/ml), and 0 pg/ml(0–3 pg/ml), respectively. There was excellent agreement (>89%,k>0.80) between IP-10, IL-2 tests and QFT-IT, better than with TST (>74%,k>0.49). The IP-10 and IL-2 responses were strongly associated with M.tuberculosis exposure and with grade of infectiousness of the index cases (p<0.0001). IP-10, IL-2, and TST but not QFT-IT was associated with age of the child in the low risk groups (p<0.02).

Conclusions/Significance

IP-10 is expressed in high levels and results of the IP-10 test were comparable to the QFT-IT. IL-2 was released in low amounts in response to the antigens and not in response to the mitogen therefore IL-2 seems a less useful marker. We have demonstrated that IP-10 and possibly IL-2 could be alternative or adjunct markers to IFN-γ in the diagnosis infection with M.tuberculosis.  相似文献   

2.

Background

There are limited data comparing the performance of the two commercially available interferon gamma (IFN-γ) release assays (IGRAs) for the diagnosis of tuberculosis (TB) in children. We compared QuantiFERON-TB gold In Tube (QFT-IT), T-SPOT.TB and the tuberculin skin test (TST) in children at risk for latent TB infection or TB disease.

Methods and Findings

The results of both IGRAs were compared with diagnosis assigned by TST-based criteria and assessed in relation to TB contact history. Results from the TST and at least one assay were available for 96 of 100 children. Agreement between QFT-IT and T-SPOT.TB was high (93% agreement, κ = 0.83). QFT-IT and T-SPOT.TB tests were positive in 8 (89%) and 9 (100%) children with suspected active TB disease. There was moderate agreement between TST and either QFT-IT (75%, κ = 0.50) or T-SPOT.TB (75%, κ = 0.51). Among 38 children with TST-defined latent TB infection, QFT-IT gold and T-SPOT.TB assays were positive in 47% and 39% respectively. Three TST-negative children were positive by at least one IGRA. Children with a TB contact were more likely than children without a TB contact to have a positive IGRA (QFT-IT LR 3.9; T-SPOT.TB LR 3.9) and a positive TST (LR 1.4). Multivariate linear regression analysis showed that the magnitude of both TST induration and IGRA IFN-γ responses was significantly influenced by TB contact history, but only the TST was influenced by age.

Conclusions

Although a high level of agreement between the IGRAs was observed, they are commonly discordant with the TST. The correct interpretation of a negative assay in a child with a positive skin test in clinical practice remains challenging and highlights the need for longitudinal studies to determine the negative predictive value of IGRAs.  相似文献   

3.
4.
5.
Interferon -gamma release assays (IGRAs) provide a new diagnostic method for Mycobacterium tuberculosis (TB) infection. However, the diagnostic value of IGRAs for extrapulmonary TB (EPTB) has not been clarified. We searched several databases and selected papers with strict inclusion criteria, evaluated the evidence of commercially available IGRAs (QuantiFERON(?) -TB Gold QFT-G or QFT-GIT and T-SPOT(?) .TB) on blood and the tuberculin skin test (TST) using random effects models. Twenty studies with 1711 patients were included. After excluding indeterminate results, pooled sensitivity for the diagnosis of EPTB was 72% [95% confidence interval (CI) 65-79%] for QFT-G or GIT and 90% (95% CI, 86-93%) for T-SPOT; in high-income countries the sensitivity of QFT-G or GIT (79%, 95% CI 72-86%) was much higher than that (29%, 95% CI 14-48%) in low/middle-income countries. Pooled specificity for EPTB was 82% (95% CI 78-87%) for QFT-G or GIT and 68% (95% CI 64-73%) for T-SPOT. Pooled sensitivity of TST from four studies in high-income countries was lower than that of IGRAs. T-SPOT was more sensitive in detecting EPTB than QFT-G or GIT and TST. However, both IGRAs and TST have similar specificity for EPTB. IGRAs have limited value as diagnostic tools to screen and rule out EPTB, especially in low/middle-income countries. The immune status of patients does not affect the diagnostic accuracy of IGRAs for EPTB.  相似文献   

6.
Bovine tuberculosis (bTB) is one of the most serious economic animal health problems affecting the cattle industry in Great Britain (GB), with incidence in cattle herds increasing since the mid-1980s. The single intradermal comparative cervical tuberculin (SICCT) test is the primary screening test in the bTB surveillance and control programme in GB and Ireland. The sensitivity (ability to detect infected cattle) of this test is central to the efficacy of the current testing regime, but most previous studies that have estimated test sensitivity (relative to the number of slaughtered cattle with visible lesions [VL] and/or positive culture results) lacked post-mortem data for SICCT test-negative cattle. The slaughter of entire herds ("whole herd slaughters" or "depopulations") that are infected by bTB are occasionally conducted in GB as a last-resort control measure to resolve intractable bTB herd breakdowns. These provide additional post-mortem data for SICCT test-negative cattle, allowing a rare opportunity to calculate the animal-level sensitivity of the test relative to the total number of SICCT test-positive and negative VL animals identified post-mortem (rSe). In this study, data were analysed from 16 whole herd slaughters (748 SICCT test-positive and 1031 SICCT test-negative cattle) conducted in GB between 1988 and 2010, using a Bayesian hierarchical model. The overall rSe estimate of the SICCT test at the severe interpretation was 85% (95% credible interval [CI]: 78-91%), and at standard interpretation was 81% (95% CI: 70-89%). These estimates are more robust than those previously reported in GB due to inclusion of post-mortem data from SICCT test-negative cattle.  相似文献   

7.
8.
9.
10.
Chen J  Zhang R  Wang J  Liu L  Zheng Y  Shen Y  Qi T  Lu H 《PloS one》2011,6(11):e26827

Background

Interferon-gamma release assays (IGRAs) have provided a new method for the diagnosis of Mycobacterium tuberculosis infection. However, the role of IGRAs for the diagnosis of active tuberculosis (TB), especially in HIV-infected patients remains unclear.

Methods

We searched PubMed, EMBASE and Cochrane databases to identify studies published in January 2001–July 2011 that evaluated the evidence of using QuantiFERON-TB Gold in-tube (QFT-GIT) and T-SPOT.TB (T-SPOT) on blood for the diagnosis of active TB in HIV-infected patients.

Results

The search identified 16 eligible studies that included 2801 HIV-infected individuals (637 culture confirmed TB cases). The pooled sensitivity for the diagnosis of active TB was 76.7% (95%CI, 71.6–80.5%) and 77.4% (95%CI, 71.4–82.6%) for QFT-GIT and T-SPOT, respectively, while the specificity was 76.1% (95%CI, 74.0–78.0%) and 63.1% (95%CI, 57.6–68.3%) after excluding the indeterminate results. Studies conducted in low/middle income countries showed slightly lower sensitivity and specificity when compared to that in high-income countries. The proportion of indeterminate results was as high as 10% (95%CI, 8.8–11.3%) and 13.2% (95%CI, 10.6–16.0%) for QFT-GIT and T-SPOT, respectively.

Conclusion

IGRAs in their current formulations have limited accuracy in diagnosing active TB in HIV-infected patients, and should not be used alone to rule out or rule in active TB cases in HIV-infected patients. Further modification is needed to improve their accuracy.  相似文献   

11.
12.

Background

In areas endemic for visceral leishmaniasis (VL), a large number of infected individuals mount a protective cellular immune response and remain asymptomatic carriers. We propose an interferon-gamma release assay (IFN-γRA) as a novel marker for latent L. donovani infection.

Methods and Findings

We modified a commercial kit (QuantiFERON) evaluating five different leishmania-specific antigens; H2B, H2B-PSA2, H2B-Lepp12, crude soluble antigen (CSA) and soluble leishmania antigen (SLA) from L. donovani with the aim to detect the cell-mediated immune response in VL. We evaluated the assay on venous blood samples of active VL patients (n = 13), cured VL patients (n = 15), non-endemic healthy controls (n = 11) and healthy endemic controls (n = 19). The assay based on SLA had a sensitivity of 80% (95% CI = 54.81–92.95) and specificity of 100% (95% CI = 74.12–100).

Conclusion

Our findings suggest that a whole-blood SLA-based QuantiFERON assay can be used to measure the cell-mediated immune response in L. donovani infection. The positive IFN-γ response to stimulation with leishmania antigen in patients with active VL was contradictory to the conventional finding of a non-proliferative antigen-specific response of peripheral blood mononuclear cells and needs further research.  相似文献   

13.
14.
Zhu C  Cui Z  Zheng R  Yang H  Jin R  Qin L  Liu Z  Wang J  Hu Z 《PloS one》2011,6(9):e24435

Objective

To evaluate the performance of phage amplified biologically assay (PhaB) for detecting tuberculosis (TB) in sputum in the pulmonary tuberculosis (PTB) patients.

Methods

Shanghai Tuberculosis Key Laboratory of Shanghai Pulmonary Hospital participated in the project in collaboration with the laboratories of six hospitals and a total of 1660 eligible participants (1351 PTB patients and 309 non-TB patients) were included in the study. The sputum samples from the participants were detected by smear microscopy, PhaB, and Löwenstein-Jensen (L-J) culture method, respectively.

Results

The overall sensitivity of PhaB were higher than that of L-J culture and smear microscopy (p<0.05). The sensitivity of PhaB for detecting smear-negative specimens was obviously higher than that of L-J culture (p<0.05). Compared with L-J culture, the overall sensitivity, specificity, PPV, NPV, ACC and Kappa value of PhaB were 98.4 (95% Cl: 96.9–99.3), 71.6 (95% Cl: 68.4–74.6), 67.7, 98.7, 81.7% and 0.643, respectively. The detection median time of PhaB only needed 48 hours, which was significantly less than that (31 days) of L-J culture method.

Conclusion

PhaB method is a rapid and sensitive method for detecting TB in sputum in PTB patients; especially for the diagnosis of smear-negative PTB, PhaB method is obviously more sensitive than L-J culture method.  相似文献   

15.
A cohort of 123 adult contacts was followed for 18‐24 months (86 completed the follow-up) to compare conversion and reversion rates based on two serial measures of QuantiFERON (QFT) and tuberculin skin test (TST) (PPD from TUBERSOL, Aventis Pasteur, Canada) for diagnosing latent tuberculosis (TB) in household contacts of TB patients using conventional (C) and borderline zone (BZ) definitions. Questionnaires were used to obtain information regarding TB exposure, TB risk factors and socio-demographic data. QFT (IU/mL) conversion was defined as <0.35 to ≥0.35 (C) or <0.35 to >0.70 (BZ) and reversion was defined as ≥0.35 to <0.35 (C) or ≥0.35 to <0.20 (BZ); TST (mm) conversion was defined as <5 to ≥5 (C) or <5 to >10 (BZ) and reversion was defined as ≥5 to <5 (C). The QFT conversion and reversion rates were 10.5% and 7% with C and 8.1% and 4.7% with the BZ definitions, respectively. The TST rates were higher compared with QFT, especially with the C definitions (conversion 23.3%, reversion 9.3%). The QFT conversion and reversion rates were higher for TST ≥5; for TST, both rates were lower for QFT <0.35. No risk factors were associated with the probability of converting or reverting. The inconsistency and apparent randomness of serial testing is confusing and adds to the limitations of these tests and definitions to follow-up close TB contacts.  相似文献   

16.
17.
18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏