共查询到20条相似文献,搜索用时 0 毫秒
1.
Advances in quantitative proteomics via stable isotope tagging and mass spectrometry 总被引:9,自引:0,他引:9
The high-throughput identification and accurate quantification of proteins are essential components of proteomic strategies for studying cellular functions and processes. Techniques that are largely based on stable isotope protein or peptide labeling and automated tandem mass spectrometry are increasingly being applied in quantitative proteomic studies. Over the past year, significant progress has been made toward improving and diversifying these technologies with respect to the methods for stable isotope labeling, process automation and data processing and analysis. Advances in stable isotope protein labeling and recent biological studies that used stable isotope based quantitative proteomics techniques are reviewed. 相似文献
2.
Advances in proteome analysis by mass spectrometry 总被引:4,自引:0,他引:4
3.
Advances in proteome analysis by mass spectrometry 总被引:4,自引:0,他引:4
Proteome characterization using mass spectrometry is essential for the systematic investigation of biological systems and for the study of gene function. Recent advances in this multifaceted field have occurred in four general areas: protein and peptide separation methodologies; selective labeling chemistries for quantitative measurement of peptide and protein abundances; characterization of post-translational protein modifications; and instrumentation. 相似文献
4.
Since most cellular processes depend on interactions between proteins, information about protein–protein interactions (PPIs) provide valuable insights into protein function. Over the last years, quantitative affinity purification followed by mass spectrometry (q-AP-MS) has become a powerful approach to investigate PPIs in an unbiased manner. In q-AP-MS the protein of interest is biochemically enriched together with its interaction partners. In parallel, a control experiment is performed to control for non-specific binding. Quantitative mass spectrometry is then employed to compare protein levels in both samples and to exclude non-specific contaminants. Here, we provide two detailed q-AP-MS protocols for pull-downs with immobilized bait proteins or transient transfection of tagged expression constructs. We discuss benefits and limitations of q-AP-MS and highlight critical parameters that need to be considered. The protocols and background information presented here allow the reader to adapt the generic q-AP-MS strategy for a wide range of biological questions. 相似文献
5.
Genotyping single-nucleotide polymorphisms by matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry 总被引:6,自引:0,他引:6
Sauer S Gut IG 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,782(1-2):73-87
In recent years matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI) has emerged as a very powerful method for genotyping single nucleotide polymorphisms. The accuracy, speed of data accumulation, and data structure are the major features of MALDI. Several SNP genotyping methods have been implemented with a high degree of automation and are being applied for large-scale association studies. Most methods for SNP genotyping using MALDI mass spectrometric detection and their potential application for high-throughput are reviewed here. 相似文献
6.
Yohei Murayama Shuya Satoh Akinori Hashiguchi Ken Yamazaki Hiroyuki Hashimoto Michiie Sakamoto 《Analytical biochemistry》2015
Time-of-flight secondary ion mass spectrometry (MS) provides secondary ion images that reflect distributions of substances with sub-micrometer spatial resolution. To evaluate the use of time-of-flight secondary ion MS to capture subcellular chemical changes in a tissue specimen, we visualized cellular damage showing a three-zone distribution in mouse liver tissue injured by acetaminophen overdose. First, we selected two types of ion peaks related to the hepatocyte nucleus and cytoplasm using control mouse liver. Acetaminophen-overdosed mouse liver was then classified into three areas using the time-of-flight secondary ion MS image of the two types of peaks, which roughly corresponded to established histopathological features. The ion peaks related to the cytoplasm decreased as the injury became more severe, and their origin was assumed to be mostly glycogen based on comparison with periodic acid–Schiff staining images and reference compound spectra. This indicated that the time-of-flight secondary ion MS image of the acetaminophen-overdosed mouse liver represented the chemical changes mainly corresponding to glycogen depletion on a subcellular scale. In addition, this technique also provided information on lipid species related to the injury. These results suggest that time-of-flight secondary ion MS has potential utility in histopathological applications. 相似文献
7.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry with delayed ion extraction (DE MALDI-TOF MS) was applied for the first time for the quantitation of sulfatide content in serum at the picomole level. The total lipids extracted by n-hexane:isopropanol (3:2, v/v) from 100 microliter of serum were saponified to convert sulfatide to its lyso form, and then the lysosulfatide was directly determined using DE MALDI-TOF MS in the presence of other degraded lipids. Hydrogenated N-acetyl lysosulfatide was used as an internal standard. The relative peak height of sulfatide was calculated and plotted versus its contents. This plot showed linearity between 2 pmol and 1 nmol of sulfatide (regression coefficient r > 0.95). Sulfatide contents of normal human sera and rabbit serum were quantitated by this method. The results corresponded well to the reported data determined by gas-liquid chromatography. This new approach was found to be sensitive, convenient, and reliable. It is expected to be applied to quantitate sulfatide from other small amounts of body fluids or tissues and to clinical examination. It is also expected to be applicable to quantitate other glycosphingolipids. 相似文献
8.
Steven B. Levery Catharina Steentoft Adnan HalimYoshiki Narimatsu Henrik ClausenSergey Y. Vakhrushev 《Biochimica et Biophysica Acta (BBA)/General Subjects》2015
Background
Global analyses of proteins and their modifications by mass spectrometry are essential tools in cell biology and biomedical research. Analyses of glycoproteins represent particular challenges and we are only at the beginnings of the glycoproteomic era. Some of the challenges have been overcome with N-glycoproteins and proteome-wide analysis of N-glycosylation sites is accomplishable today but only by sacrificing information of structures at individual glycosites. More recently advances in analysis of O-glycoproteins have been made and proteome-wide analysis of O-glycosylation sites is becoming available as well.Scope of review
Here we discuss the challenges of analysis of O-glycans and new O-glycoproteomics strategies focusing on O-GalNAc and O-Man glycoproteomes.Major conclusions
A variety of strategies are now available for proteome-wide analysis of O-glycosylation sites enabling functional studies. However, further developments are still needed for complete analysis of glycan structures at individual sites for both N- and O-glycoproteomics strategies.General significance
The advances in O-glycoproteomics have led to identification of new biological functions of O-glycosylation and a new understanding of the importance of where O-glycans are positioned on proteins. 相似文献9.
10.
Woods AS Ugarov M Jackson SN Egan T Wang HY Murray KK Schultz JA 《Journal of proteome research》2006,5(6):1484-1487
Most MALDI instrumentation uses UV lasers. We have designed a MALDI-IM-oTOF-MS which employs both a Nd:YAG laser pumped optical parametric oscillator (OPOTEK, lambda = 2.8-3.2 microm at 20 Hz) to perform IR-LDI or IR-MALDI and a Nd:YLF laser (Crystalaser, lambda = 249 nm at 200 Hz) for the UV. Ion mobility (IM) gives a fast separation and analysis of biomolecules from complex mixtures in which ions of similar chemical type fall along well-defined "trend lines". Our data shows that ion mobility allows multiply charged monomers and multimers to be resolved; thus, yielding pure spectra of the singly charged protein ion which are virtually devoid of chemical noise. In addition, we have demonstrated that IR-LDI produced similar results as IR-MALDI for the direct tissue analysis of phospholipids from rat brain. 相似文献
11.
12.
Adachi J Yoshioka N Funae R Nushida H Asano M Ueno Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,806(1):41-46
An improved technique for the analysis of phosphatidylcholine (PC) monohydroperoxides was developed using quadrupole time-of-flight (Q-TOF) mass spectrometry with electrospray ionization. Separation was obtained using an HPLC C8 column with a gradient of methanol and 10 mM aqueous ammonium acetate. Monohydroperoxides of palmitoyl-linoleoyl (C16:0/C18:2) PC, stearoyl-linoleoyl (C18:0/C18:2) PC, and oleoyl-linoleoyl (C18:1/C18:2) PC were detected mainly as MH(+) and [M+Na](+) ions in the heart of the intact rat. Using standard synthetic PCOOH (C16:0/C18:2-OOH), the lipid extract component was identified as (C16:0/C18:2-OOH) PC based on the product ions of ESI-MS-MS and, the PCOOH concentration was quantitated using HPLC with chemiluminescence detection. Two epoxyhydroxy derivatives of the three PCs mentioned above were also detected. This is the first report to show the presence of monohydroperoxides and epoxyhydroxy-derivatives of (C16:0/C18:2)PC, (C18:0/C18:2)PC, and (C18:1/C18:2) PC in the rat heart. 相似文献
13.
14.
The aim of this study was to discriminate 30 Vibrio strains isolated from two wastewater treatment plants from Agadir, Morocco by two molecular typing methods, pulsed-field gel electrophoresis (PFGE) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Out of the 30 strains of Vibrio examined in this study, 5 isolates could not be typed by PFGE and consistently appeared as a smear on the gel. In general, high genetic biodiversity among the Vibrio strains was found regardless to the isolation source. The results of MALDI TOF analysis show a high congruence of strain grouping demonstrating the accuracy and reliability of MALDI-TOF MS. 相似文献
15.
Multiplex single-nucleotide polymorphism genotyping by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry 总被引:1,自引:0,他引:1
A robust high-throughput single-nucleotide polymorphism (SNP) genotyping method is reported, which applies allele-specific extension to achieve allelic discrimination and uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to measure the natural molecular weight difference of oligonucleotides for determination of the base in a single-nucleotide polymorphic location. Tenfold PCR is performed successfully by carefully designing the primers and adjusting the conditions of PCR. In addition, two ways used for PCR product purification are compared and the matrix used in mass spectrometry for high-throughput oligonucleotide analysis is evaluated. The result here shows that the method is very effective and suitable for high-throughput genotyping of SNPs. 相似文献
16.
Lipid specificity of surfactant protein B studied by time-of-flight secondary ion mass spectrometry
下载免费PDF全文

One of the key functions of mammalian pulmonary surfactant is the reduction of surface tension to minimal values. To fulfill this function it is expected to become enriched in dipalmitoylphosphatidylcholine either on its way from the alveolar type II pneumocytes to the air/water interface of the lung or within the surface film during compression and expansion of the alveoli during the breathing cycle. One protein that may play a major role in this enrichment process is the surfactant protein B. The aim of this study was to identify the lipidic interaction partner of this protein. Time-of-flight secondary ion mass spectrometry was used to analyze the lateral distribution of the components in two SP-B-containing model systems. Either native or partly isotopically labeled lipids were analyzed. The results of both setups give strong indications that, at least under the specific conditions of the chosen model systems (e.g., concerning pH and lipid composition), the lipid interacting with surfactant protein B is not phosphatidylglycerol as generally accepted, but dipalmitoylphosphatidylcholine instead. 相似文献
17.
Steen H Jebanathirajah JA Rush J Morrice N Kirschner MW 《Molecular & cellular proteomics : MCP》2006,5(1):172-181
The mass spectrometric analysis of protein phosphorylation is still far from being routine, and the outcomes thereof are often unsatisfying. Apart from the inherent problem of substoichiometric phosphorylation, three arguments as to why phosphorylation analysis is so problematic are often quoted, including (a) increased hydrophilicity of the phosphopeptide with a concomitant loss during the loading onto reversed-phase columns, (b) selective suppression of the ionization of phosphopeptides in the presence of unmodified peptides, and (c) lower ionization/detection efficiencies of phosphopeptides as compared with their unmodified cognates. Here we present the results of a study investigating the validity of these three arguments when using electrospray ionization mass spectrometry. We utilized a set of synthetic peptide/phosphopeptide pairs that were quantitated by amino acid analysis. Under the applied conditions none of the experiments performed supports the notions of (a) generally increased risks of losing phosphopeptides during the loading onto the reversed-phase column because of decreased retention and (b) the selective ionization suppression of phosphopeptides. The issue of ionization/detection efficiencies of phosphopeptides versus their unphosphorylated cognates proved to be less straightforward when using electrospray ionization because no evidence for decreased ionization/detection efficiencies for phosphopeptides could be found. 相似文献
18.
Vogel JS 《BioTechniques》2005,(Z1):25-29
Accelerator mass spectrometry (AMS) counts individual rare, usually radio-, isotopes such as radiocarbon at high efficiency and specificity in milligram-sized samples. AMS traces very low chemical doses (micrograms) and radiative doses (100 Bq) of isotope-labeled compounds in animal models and directly in humans for pharmaceutical, nutritional, or toxicological research. Absorption, metabolism, distribution, binding, and elimination are all quantifiable with high precision after appropriate sample definition. 相似文献
19.
Quantification and confirmation of flunixin in equine plasma by liquid chromatography-quadrupole time-of-flight tandem mass spectrometry 总被引:1,自引:0,他引:1
Luo Y Rudy JA Uboh CE Soma LR Guan F Enright JM Tsang DS 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,801(2):173-184
The method describes quantification and confirmation of flunixin in equine plasma by liquid chromatography-quadrupole time-of-flight mass spectrometry (LC/Q-TOF/MS/MS). Samples were screened by enzyme-linked immunosorbent assay (ELISA) and only those samples presumptively declared positive were subjected to quantification and confirmation for the presence of flunixin by this method. The method is also readily adaptable to instrumental screening for the analyte. Flunixin was recovered from plasma by liquid-liquid extraction (LLE). The sample was diluted with 2 ml saturated phosphate buffer (pH 3.10) prior to LLE. The dried extract was reconstituted in acetonitrile:water:formic acid (50:50:0.1, v/v/v) and subsequently analyzed on a Q-TOF tandem mass spectrometer (Micromass) operated under electrospray ionization positive ion mode. The concentration of flunixin was determined by the internal standard (IS) calibration method using the peak area ratio with clonixin as the IS. The limits of detection (LOD) and quantification (LOQ) for flunixin in equine plasma were 0.1 and 1 ng/ml, respectively, whereas the limit of confirmation (LOC) was 2.5 ng/ml. The qualifying ions for the identification of flunixin were m/z 297 [M+H](+), 279 (BP), 264, 259, 239 and those for clonixin (IS) were m/z 263 [M+H](+), 245 (BP) and 210. The measurement uncertainty about the result was 8.7%. The method is simple, sensitive, robust and reliably fast in the quantification and confirmation of flunixin in equine plasma. Application of this method will assist racing authorities in the enforcement of tolerance plasma concentration of flunixin in the racehorse on race day. 相似文献
20.
Sinnaeve BA Decaestecker TN Claerhout IJ Kestelyn P Remon JP Van Bocxlaer JF 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,785(1):193-196
We investigated the corneal precipitate of a 6-year-old boy with vernal keratoconjunctivitis (VKC), treated with topical ofloxacin 0.3% eyedrops. Because of the extremely small sample amount (corneal scraping), a very sensitive and specific method was needed with the possibility of an unambiguous identification of ofloxacin, supposed to be present in the precipitate. In this respect, tandem Q-TOF mass spectrometry combined with micro LC (1 mm I.D.) was chosen. Confirmation of the presence of ofloxacin in the deposit was obtained by means of the characteristic product ion spectrum produced by CID. This clearly indicated that the precipitate, removed by corneal scraping from the 6-year-old boy with VKC, contained ofloxacin. 相似文献