首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

2.
A sensitive high‐performance liquid chromatographic (HPLC) method was developed for the determination of nizatidine in human plasma. Nizatidine was derivatized by 4‐fluoro‐7‐nitrobenzofurazan (NBD‐F). Chromatographic separation was performed on a Inertsil C18 column (150 mm × 4.6 mm, 5 µm) using isocratic elution by a mobile phase consisting of methanol/water (55:45) at a flow rate of 1.2 mL/min. Amlodipine was used as the internal standard (IS). Fluorescence detector was used operated at 461 nm (excitation) and 517 nm (emission), respectively. The calibration curve was linear over the range of 50–2000 ng/mL. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (150 mg) of nizatidine. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

4.
A highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of forsythiaside in rat plasma using epicatechin as internal standard. The analytes were extracted by solid-phase extraction and chromatographied on a C18 column eluted with a gradient mobile phase of acetonitrile and water both containing 0.2% formic acid. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 623 → 161 and m/z 289 → 109 for forsythiaside and epicatechin, respectively. The assay was linear over the concentration ranges of 2.0–50.0 and 50.0–5000.0 ng/mL with limits of detection and quantification of 0.2 and 1.0 ng/mL, respectively. The precision was <10.8% and the accuracy was >91.9%, and extraction recovery ranged from 81.3% to 85.0%. This method was successfully applied to a pharmacokinetic study of forsythiaside in rats after intravenous (20 mg/kg) and oral (100 mg/kg) administration, and the result showed that the compound was poorly absorbed with an absolute bioavailability being approximately 0.5%.  相似文献   

5.
Letosteine has been found to be effective in treating patients with chronic bronchopneumopathies in clinical practice. To provide robust support for its pharmacokinetic and clinical studies, a rapid and sensitive method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the analysis of letosteine in plasma samples. After protein precipitation, the plasma samples were separated on a reversed-phase C(18) column in less than 1.5 min. The LC-MS/MS system was performed in the positive ion multiple-reaction-monitoring (MRM) mode to produce intensive product ions of m/z 280.1→160.0 for letosteine and m/z 248.1→121.1 for the internal standard, tinidazole. The method was found to have excellent linearity (r ≥ 0.9974), precision (RSD ≤ 5.83%), extraction recovery (71.8-73.0%) and stability (RE, -8.45% to 9.03%) over a concentration range of 0.1140-152.0 μgL(-1). Compared to the previous published radioactive method, LC-MS/MS method showed many advantages including shorter analysis time, simpler preparation procedure, increased sensitivity as well as lower safety risks. In addition, this method was successfully applied to study the pharmacokinetics of letosteine following a single and multiple dose oral administration in Chinese healthy volunteers.  相似文献   

6.
We described the development and full validation of rapid and accurate liquid chromatography method, coupled with tandem mass spectrometry detection, for quantification of meprobamate in human plasma with [(13)C-(2)H(3)]-meprobamate as internal standard. Plasma pretreatment involved a one-step protein precipitation with acetonitrile. Separation was performed by reversed-phase chromatography on a Luna MercuryMS C18 (20 mm×4 mm×3 μm) column using a gradient elution mode. The mobile phase was a mix of distilled water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid. The selected reaction monitoring transitions, in electrospray positive ionization, used for quantification were 219.2→158.2 m/z and 223.1→161.1m/z for meprobamate and internal standard, respectively. Qualification transitions were 219.2→97.0 and 223.1→101.1 m/z for meprobamate and internal standard, respectively. The method was linear over the concentration range of 1-300 mg/L. The intra- and inter-day precision values were below 6.4% and accuracy was within 95.3% and 103.6% for all QC levels (5, 75 and 200 mg/L). The lower limit of quantification was 1 mg/L. Total analysis time was reduced to 6 min including sample preparation. The present method is successfully applied to 24/7 clinical toxicology and demonstrated its usefulness to detect meprobamate poisoning.  相似文献   

7.
A selective, sensitive, and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of aripiprazole and its active metabolite dehydroaripiprazole in human plasma has been developed using papaverine as internal standard (IS). LC-MS/MS analysis was carried out on a Finnigan LC-TSQ Quantum mass spectrometer using positive ion electrospray ionization (ESI+) and selected reaction monitoring (SRM). The assays for aripiprazole and dehydroaripiprazole were linear over the ranges of 0.1 to 600 ng/ml and 0.01 to 60 ng/ml, respectively. The average recoveries in plasma samples both were better than 85%. The intra- and interrun precision and accuracy values were found to be within the assay variability criteria limits according to the US Food and Drug Administration guidelines. The developed method was proved to be suitable for use in a clinical pharmacokinetic study after a single oral administration of a 5-mg aripiprazole tablet in healthy Chinese volunteers.  相似文献   

8.
Helicid is a traditional Chinese medicine used to treat headache and insomnia with definite effects. To facilitate pharmacokinetic studies of helicid in man, a sensitive and specific LC-MS/MS method for the quantitative detection of helicid in human plasma was developed and validated. The method involved the addition of bergeninum as the internal standard (IS), protein precipitation, HPLC separation, and quantification by MS/MS system using negative electrospray ionization in the multiple reaction monitoring mode (MRM). The precursor→product ion transitions were monitored at m/z 282.8→120.9 for helicid and m/z 326.9→192.2 for the IS, respectively. The lower limit of quantification (LLOQ) was 0.2 μg/L. The calibration curves for helicid was linear over a concentration range of 0.2-20 μg/L. The intra- and inter-batch analyses of QC samples at 0.4, 2, 20 μg/L indicated good precision (%R.S.D. between 2.69 and 5.47%) and accuracy (between 96.15 and 105.05%). The helicid was stable in human plasma stored at room temperature for at least 24h, 4°C for at least 24h, -20°C for at least 1 month, and for routine three freeze-thaw cycles. This accurate and specific assay provides a useful method for evaluating the pharmacokinetic profile of helicid in humans.  相似文献   

9.
A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the determination of human plasma homocysteine (Hcy), an important independent risk factor for cardiovascular disease, with a simplified sample pretreatment procedure and a zero blank free of endogenous Hcy for calibrator/QC preparation. Following protein precipitation, chromatographic separation was performed on Hypersil Aquasil C18 column (50 mm x 2.1mm, 5 microm, Thermo) using mobile phase of aqueous 10% methanol containing 0.02% formic acid at 0.25 mL/min. Hcy and deuterated internal standard were detected in the multiple reaction monitoring mode with precursor to product ion transitions of m/z 136.1/90.0 and 140.1/94.0, respectively. The retention time was 1.2 min, and the total run time was 2 min per injection. A streamlined three-point calibration curve and one-point QC was used. Excellent linearity was observed with correlation coefficient (r)>0.99. The intra- and inter-batch were < or =3.24% and < or =4.04%, and accuracy was within +/-10%. Method comparison between the proposed method (y) and FPIA assay (x) demonstrated a correlation equation of y=1.003x + 0.4318 (r=0.9589). The developed method, improved for automation with cost-effective reagents, was proven to be suitable for high-throughput quantitative determination of Hcy in clinical practice by successfully applying it to the cardiovascular disease study.  相似文献   

10.
A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the determination of cycloserine in human plasma is developed using niacin as internal standard (IS). The analyte and IS were extracted from 500 μL of human plasma via solid phase extraction on Waters Oasis MCX cartridges. Chromatographic separation was achieved on a Peerless Basic C18 (100 mm × 4.6mm, 3 μm) column under isocratic conditions. Detection of analyte and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for cycloserine and niacin were at m/z 103.1 → 75.0 and 124.1 → 80.1 respectively. The method was fully validated for its selectivity, interference check, sensitivity, carryover check, linearity, precision and accuracy, reinjection reproducibility, recovery, matrix effect, ion suppression/enhancement, stability and dilution integrity. The limit of detection (LOD) and lower limit of quantitation of the method were 0.0013 and 0.20 μg/mL respectively with a linear dynamic range of 0.20-30.00 μg/mL for cycloserine. The intra-batch and inter-batch precision (%CV) across six quality control levels was less than 8.0% for cycloserine. The method was successfully applied to a bioequivalence study of 250 mg cycloserine capsule formulation in 24 healthy Indian male subjects under fasting condition.  相似文献   

11.
Cloperastine is a central antitussive used to reduce the frequency and intensity of coughing on a short-term basis. In this study, a reliable chiral LC-MS/MS technology has been developed for the quantification of cloperastine enantiomers in the rat plasma. Carbinoxamine was selected as the internal standard. The enantioseparation of cloperastine was performed on a Chiralpak IA column with a mobile phase composed of acetonitrile-water-ammonium hydroxide (80:20:0.1, v/v/v) at a flow rate of 0.6 mL/min. Cloperastine enantiomers were detected by mass spectrometry in multiple reaction monitoring mode with a positive electrospray ionization source. The method was validated over the linear concentration range of 0.05 to 10.0 ng/mL (5.0 × 10−4 ng to 0.10 ng) for both enantiomers. The lower limit of quantification (LLOQ) for each analyte was determined as 0.05 ng/mL. The relative standard deviations (RSDs) of intraday and interday precision was less than 13.9%, and the relative error (RE) of accuracy ranged from −5.4% to 6.1%, which were within the acceptance criteria. Finally, an application to the stereoselective pharmacokinetics of cloperastine in rats was successfully realized in our assay. The developed method on a commercially available Chiralpak IA column under isocratic mobile phase is advantageous to analyze cloperastine enantiomers in plasma samples collected for enantioselective metabolism or drug interaction studies.  相似文献   

12.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for simultaneous quantitative determination of valproic acid and three major metabolites (3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid) in human plasma. The analytes and internal standard were isolated from 200 μL samples by solid phase extraction using a ZORBAX SB-C? column (3.5 μm, 2.1×100 mm) with an isocratic mobile phase consisting of methanol-10mM ammonium acetate (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. The method had a chromatographic total run time of 2.0 min. The lower limit of quantification of valproic acid, 3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid of the method was 2030, 51.5, 50.15 and 51.25 ng/mL, respectively. The method was linear for valproic acid and the three metabolites with correlation coefficients >0.995 for all analytes. The intra-day and inter-day accuracy and precision of the assay were less than 15.0%. This analytical method was successfully used to assay plasma concentrations of valproic acid and the three metabolites in human plasma from epileptic patients.  相似文献   

13.
A sensitive and reproducible high performance liquid chromatography (HPLC)-UV method for determination of nicousamide, an inhibitor of rennin and transforming growth factor-beta1 (TGF-beta1) type II receptors, has been developed and validated. Following acetonitrile deproteiniation, samples were separated by isocratic reversed-phase HPLC on an Aichrom Bond-AQ C(18) column and quantified using UV detection at 320 nm. The mobile phase was acetonitrile/water (ratio 62:38 containing 0.1% H(3)PO(4)), with a flow-rate of 1.0 ml/min. A linear curve over the concentration range 5-200 ng/ml (r(2)=0.9978) was obtained. The coefficients of the variation for the intra- and inter-day precisions ranged from 1.4-10.7% and 1.8-7.1%, respectively. The percentage of relative recovery was 91.56-105.45%. The method was used to determine the plasma concentration-time profiles for nicousamide after oral doses of 30, 100 and 300 mg/kg in dogs. A nonlinear pharmacokinetics was found in dogs at doses from 30 to 300 mg/kg. Following 30 mg/kg oral dose, the C(max) and AUC in females were lower than that in male. There is a potential for accumulation in dogs following multiple doses.  相似文献   

14.
This paper describes an HPLC method for the determination of tramadol and its major active metabolite, O-desmethyltramadol (ODT), in human plasma. Sample preparation involved liquid-liquid extraction with diethyl ether-dichloromethane-butanol (5:3:2, v/v/v) and back extraction with sulphuric acid. Tramadol, ODT and the internal standard, sotalol, were separated by reversed phase HPLC using 35% acetonitrile and an aqueous solution containing 20 mM sodium phosphate buffer, 30 mM sodium dodecyl sulphate and 15 mM tetraethylammonium bromide pH 3.9. Detection was by fluorescence with excitation and emission wavelengths of 275 and 300 nm, respectively. The method was linear for tramadol (3-768 ng/ml) and ODT (1.5-384 ng/ml) with mean recoveries of 87.2% and 89.8%, respectively. Intra- and inter-day precisions were 10.34% and 8.43% for tramadol and 9.43% and 8.75% for ODT at the respective limits of quantitation (3 and 1.5 ng/ml). Accuracy for tramadol ranged from 96.2% to 105.3%. The method was applied to a pharmacokinetic study of tramadol in human volunteers.  相似文献   

15.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed to determine cefixime ((6R,7R)-7-[(Z)-2-(2-amino-4-thiazolyl)-2-(carboxymethoxyimino)acetamido]-8-oxo-3-vinyl-5-thia-1-azabicyclo-[4,2,0]-oct-2-ene-2-carboxylic acid) in human plasma. After a simple protein precipitation using acetonitrile, the post-treatment samples were analyzed on a C(8) column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water-formic acid (40:60:0.5, v/v/v). The analyte and internal standard cefetamet were both detected by use of selected reaction monitoring mode. The method was linear in the concentration range of 0.05-8.0 microg/ml. The lower limit of quantification was 0.05 microg/ml. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 12.7%. The accuracy determined at three concentrations (0.05, 0.80 and 7.2 microg/ml for cefixime) was within +/-2.0% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method herein described was successfully applied for the evaluation of pharmacokinetic profiles of cefixime capsule in 24 healthy volunteers.  相似文献   

16.
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in human plasma. HSYA was extracted from human plasma by using solid-phase extraction technique. Puerarin was used as the internal standard. A Shim-pack VP-ODS C(18) (150mm x 4.6mm, 5 microm) column and isocratic elution system composing of methanol and 5mM ammonium acetate (80:20, v/v) provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 611.19-->491.19 for HSYA and m/z 415.19-->295.10 for puerarin. The proposed method has been validated with a linear range of 1-1000 ng/ml for HSYA with a correlation coefficient >/=0.999. The lower limit of quantitation was 1 ng/ml. The intra-batch and inter-batch precision and accuracy were within 10%. The average extraction recovery was 81.7%. The total run time was 5.5 min. The validated method was successfully applied to the study on pharmacokinetics of HSYA in 12 healthy volunteers after a single oral administration of safflower oral solution containing 140 mg of HSYA.  相似文献   

17.
Buprenorphine (BUP), a synthetic opioid analgesic, is frequently abused alone, and in association with benzodiazepines. Fatalities involving buprenorphine alone seem very unusual while its association with benzodiazepines, such as flunitrazepam (FNZ), has been reported to result in severe respiratory depression and death. The quantitative relationship between these drugs remain, however, uncertain. Our objective was to develop an analytical method that could be used as a means to study and explore, in animals, the toxicity and pharmacological interaction mechanisms between buprenorphine, flunitrazepam and their active metabolites. A procedure based on gas chromatography-mass spectrometry (GC-MS) is described for the simultaneous analysis of buprenorphine, norbuprenorphine (NBUP), flunitrazepam, N-desmethylflunitrazepam (N-DMFNZ) and 7-aminoflunitrazepam (7-AFNZ) in rat plasma. The method was set up and adapted for the analysis of small plasma samples taken from rats. Plasma samples were extracted by liquid-liquid extraction using Toxi-tubes A. Extracted compounds were derivatized with N,O-bis-(trimethylsilyl)trifluoroacetamide (BSTFA), using trimethylchlorosilane (TMCS) as a catalyst. They were then separated by GC on a crosslinked 5% phenyl-methylpolysiloxane analytical column and determined by a quadrupole mass spectrometer detector operated under selected ion monitoring mode. Excellent linearity was found between 0.125 and 25 ng/microl plasma for BUP, 0.125 and 12.5 ng/microl for NBUP and N-DMFNZ, 0.125 and 5 ng/microl for FNZ, and between 0.025 and 50 ng/microl for 7-AFNZ. The limit of quantification was 0.025 ng/microl plasma for 7-AFNZ and 0.125 ng/microl for the four other compounds. A good reproducibility (intra-assay CV=0.32-11.69%; inter-assay CV=0.63-9.55%) and accuracy (intra-assay error=2.58-12.73%; inter-assay error=0.83-11.07%) were attained. Recoveries were 71, 67 and 81%, for BUP, FNZ and N-DMFNZ, respectively, and 51% for NBUP and 7-AFNZ, with CV ranging from 5.4 to 13.9%, and were concentration-independent. The GC-MS method was successfully applied to the pharmacokinetic study of BUP, NBUP, FNZ, DMFNZ and 7-AFNZ in rats, after administration of BUP and FNZ.  相似文献   

18.
A rapid, specific, and reliable LC-MS/MS based bioanalytical method was developed and validated for the simultaneous determination of naloxone (NLX) and its two metabolites, 6β-naloxol (NLL) and naloxone-3β-D-glucuronide (NLG) in mouse plasma. The optimal chromatographic behavior of these analytes was achieved on an Aquasil C18 column (50 mm × 2.1 mm, 5 μm) using reversed phase chromatography. The total LC analysis time per injection was 2.5 min with a flow rate of 1.0 mL/min with gradient elution. Sample preparation via protein precipitation with acetonitrile in a 96-well format was applied for analyses of these analytes. The analytes were monitored by electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. Modification of collision energy besides chromatographic separation was applied to further eliminate interference peaks for NLL and NLG. The method validation was conducted over the curve range of 0.200/0.400/0.500 to 100/200/250 ng/mL for NLX/NLL/NLG, respectively, using 0.0250 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤ 6.5% relative standard deviation (RSD) and -8.3 to -2.5% relative error (RE). The method was successfully applied to determine the concentrations of NLX, NLL, and NLG in incurred mouse plasma samples.  相似文献   

19.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

20.
A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 microl plasma of rats. Sample preparation was carried out by deproteinization with 100 microl of acetonitrile. A 20 microl of supernatant was directly injected into the HPLC system with methanol-double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a microBondapak C(18) column at 30 degrees C. The peak was detected at 278 nm. The calibration curve was linear (r(2)=0.9989) in the concentration range of 0.028-2.80 microg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号