首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Epidemiological data on the health effects of A-bomb radiation in Hiroshima and Nagasaki provide the framework for setting limits for radiation risk and radiological protection. However, uncertainty remains in the equivalent dose, because it is generally believed that direct derivation of the relative biological effectiveness (RBE) of neutrons from the epidemiological data on the survivors is difficult. To solve this problem, an alternative approach has been taken. The RBE of polyenergetic neutrons was determined for chromosome aberration formation in human lymphocytes irradiated in vitro, compared with published data for tumor induction in experimental animals, and validated using epidemiological data from A-bomb survivors. The RBE of fission neutrons was dependent on dose but was independent of the energy spectrum. The same RBE regimen was observed for lymphocyte chromosome aberrations and tumors in mice and rats. Used as a weighting factor for A-bomb survivors, this RBE system was superior in eliminating the city difference in chromosome aberration frequencies and cancer mortality. The revision of the equivalent dose of A-bomb radiation using DS02 weighted by this RBE system reduces the cancer risk by a factor of 0.7 compared with the current estimates using DS86, with neutrons weighted by a constant RBE of 10.  相似文献   

2.
The lineal energy distribution and several other dosimetric parameters were measured for the neutrons emitted from a replica of the Hiroshima bomb to determine their usefulness in biological experiments designed to estimate the effectiveness of actual Hiroshima neutrons. The "Little-Boy" replica (LBR) was constructed at the Los Alamos National Laboratory in support of the recent atomic-bomb dose reevaluation and was made of identical materials and had nearly identical dimensions and geometry as the Hiroshima bomb. However, the LBR was operated as a steady-state nuclear reactor, which permitted measurements under controlled conditions. Detailed dosimetric measurements and calculations were made at distances of up to 2.1 m from the center of the LBR uranium core. At these distances, the in-air kerma was approximately 97% from neutrons and kerma rates were shown to be particularly useful for biological experiments (up to approximately 7 Gy/h was possible). Quantitative intercomparisons of neutron energy spectra, lineal energy distributions, and measured cytogenetic results for several fission-neutron sources indicate that Hiroshima and LBR neutrons should be of similar biological effectiveness. Based on these evaluations, and cytogenetic results for LBR neutrons reported in a companion paper (this issue), it is estimated that Hiroshima neutrons were 20 to 30% more effective than the fission neutrons commonly used in radiobiology.  相似文献   

3.
V A Lisin 《Radiobiologiia》1989,29(3):399-402
A study was made of the dependence of relative biological effectiveness (RBE) and isoeffective dose of fast neutrons (produced by U-120 cyclotron) upon the depth of the exposed tissue. It was shown that the isoeffective dose and RBE vary significantly with the depth of the tissue-equivalent medium. The investigations were carried out with the purpose of improving the radiobiological and dosimetric techniques for the treatment of malignant tumors using a neutron beam from U-120 cyclotron.  相似文献   

4.
PurposeThe purpose of this study was to; (1) investigate employing a novel position-sensitive mega-size polycarbonate (MSPC) dosimeter for photoneutron (PN) depth, profile and dose equivalent distributions studies in a multilayer polyethylene phantom in a Siemens ONCOR accelerator, and (2) develop depth dose equivalent distribution matrix data at different depths and positions of the phantom for patient PN dose equivalent determination and in particular for PN secondary cancer risk estimation.MethodsPosition-sensitive MSPC dosimeters were successfully exposed at 9 different depths of the phantom in a 10 × 10 cm2 X-ray field. The dosimeters were processed in mega-size electrochemical chambers at optimum conditions. Each MSPC dosimeter was placed at a known phantom depth for PN depth dose equivalents and profiles on transverse, longitudinal and diagonal axes and isodose equivalent distribution studies in and out of the X-ray beam.ResultsPN dose equivalent distributions at any depth showed the highest value at the beam central axis and decreases as the distance increases. PN dose equivalent at any position studied in the axes has a maximum value on the phantom surface which decreases as depth increases due to flux reduction by multi-elastic scattering interactions.ConclusionsExtensive PN dose equivalent matrix data at different depths and positions in the phantom were determined. The position-sensitive MSPC dosimeters proved to be highly efficient for PN depth, profile and isodose equivalent distribution studies. The extensive data obtained highly assists for determining PN dose equivalent of a patient undergoing high-energy X-ray therapy and for PN secondary cancer risk estimation.  相似文献   

5.
The effective dose of combined spectrum energy neutrons and high energy spectrum γ-rays in A-bomb survivors in Hiroshima and Nagasaki has long been a matter of discussion. The reason is largely due to the paucity of biological data for high energy photons, particularly for those with an energy of tens of MeV. To circumvent this problem, a mathematical formalism was developed for the photon energy dependency of chromosomal effectiveness by reviewing a large number of data sets published in the literature on dicentric chromosome formation in human lymphocytes. The chromosomal effectiveness was expressed by a simple multiparametric function of photon energy, which made it possible to estimate the effective dose of spectrum energy photons and differential evaluation in the field of mixed neutron and γ-ray exposure with an internal reference radiation. The effective dose of reactor-produced spectrum energy neutrons was insensitive to the fine structure of the energy distribution and was accessible by a generalized formula applicable to the A-bomb neutrons. Energy spectra of all sources of A-bomb γ-rays at different tissue depths were simulated by a Monte Carlo calculation applied on an ICRU sphere. Using kerma-weighted chromosomal effectiveness of A-bomb spectrum energy photons, the effective dose of A-bomb neutrons was determined, where the relative biological effectiveness (RBE) of neutrons was expressed by a dose-dependent variable RBE, RBE(γ, D n), against A-bomb γ-rays as an internal reference radiation. When the newly estimated variable RBE(γ, D n) was applied to the chromosome data of A-bomb survivors in Hiroshima and Nagasaki, the city difference was completely eliminated. The revised effective dose was about 35% larger in Hiroshima, 19% larger in Nagasaki and 26% larger for the combined cohort compared with that based on a constant RBE of 10. Since the differences are significantly large, the proposed effective dose might have an impact on the magnitude of the risk estimates deduced from the A-bomb survivor cohort.  相似文献   

6.
Measurements were performed on the 30, 40 and 60-mm 90Sr/Y beta-emitter source trains used in the Novoste Beta-Cath system to determine the dosimetric characteristics of the sources at millimeter distances and provide the necessary TG-60 dosimetry parameters for mapping the dose distributions. These measurements were carried out in a Solid Water phantom where MD-55-2 Gafchromic films were placed in direct contact with a 5 French (F) catheter used for the 30 and 60-mm source trains and a 3.5 F catheter used for a thinner 40-mm source train. The dosimetric analysis was performed according to the AAPM TG-60 formalism. For the 30-mm source train, data were collected with the source axis at distances of 0.41 and 1.19 mm from the film surface, respectively, in order to investigate possible dosimetric effects due to the intrinsic off centering of the source train lumen within the 5 F catheter. Absolute dose rates at 2 mm were determined by calibrating the radiochromic film in a high energy electron beam from a radiotherapy accelerator. The dose rates at a radial distance of 2 mm were found to be within 10% of the values provided by Novoste. Radial dose functions from this study were in good agreement (< or = 10%) with a 30-mm, 90Sr/Y source train dose data generated from C. G. Soares et al. 90Sr/Y single seed data. However, larger differences were observed at distances shorter than 1 mm when compared to radial dose functions from the Novoste Monte Carlo data.  相似文献   

7.
The partial tolerance type of 'top-up' experiment has been investigated to determine the resolution of this approach for studying the damage to mouse skin from very small doses of X-rays and neutrons. The effect of 20 fractions, each as small as 0.10 Gy of X-rays or of 0.05 Gy of neutrons, can be detected if 3 MeV neutrons are used as the 'top-up' reference radiation. This capability results from the almost linear underlying dose-response curve and highly reproducible dose-effect relationship for the low energy neutrons. The data fit the linear quadratic model of dose fractionation for X-rays down to fractional doses of 0.75 Gy, but at lower doses there is a trend towards an increase in the skin radiosensitivity. Modelling shows that this might be consistent with a sub-population of the cells showing an exceptional radiosensitivity, and a replenishment of this subpopulation occurring in the 8 h between small dose fractions. More experiments are needed at very low doses in order to confirm this hypothesis for skin and for other tissues.  相似文献   

8.
9.
The experimental design consisting of a partial tolerance dose followed by a top-up dose, is used as a method of comparing the effects of different radiations and irradiation schedules in vivo. It complements the usual approach of giving multiple equal fractions of a single radiation type to obtain an iso-effect, as it enables low doses per fraction to be studied without the need to use a large number of fractions or a long overall time. For normal tissues in animals, the effect of X-ray doses as low as 0.1 Gy per fraction can be detected when given as 20-40 fractions followed by a top-up dose of neutrons. In order to minimize variations in the effect of the top-up dose, neutrons are used as a top-up radiation in preference to X-rays. The methods of implementing this approach are explained in detail. Analysis of the data is described, with emphasis on the Linear Quadratic model of radiation dose-fractionation. However, it is not necessary to adopt this or any particular mathematical model in order to intercompare directly the effects of different radiations or irradiation schedules using the top-up approach. Such models nevertheless simplify the design of top-up experiments. Whilst any type of radiation can in principle be used as the top-up, this is given optimally as a dose of fast neutrons split into two fractions.  相似文献   

10.
In the context of accidental or intentional radiation exposures (nuclear terrorism), it is essential to separate rapidly those individuals with substantial exposures from those with exposures that do not constitute an immediate threat to health. Low-frequency electron paramagnetic resonance (EPR) spectroscopy provides the potential advantage of making accurate and sensitive measurements of absorbed radiation dose in teeth without removing the teeth from the potential victims. Up to now, most studies focused on the dose-response curves obtained for gamma radiation. In radiation accidents, however, the contribution of neutrons to the total radiation dose should not be neglected. To determine how neutrons contribute to the apparent dose estimated by EPR dosimetry, extracted whole human teeth were irradiated at the SILENE reactor in a mixed neutron and gamma-radiation field simulating criticality accidents. The teeth were irradiated in free air as well as in a paraffin head phantom. Lead screens were also used to eliminate to a large extent the contribution of the gamma radiation to the dose received by the teeth. The EPR signals, obtained with a low-frequency (1.2 GHz) spectrometer, were compared to dosimetry measurements at the same location. The contribution of neutrons to the EPR dosimetric signal was negligible in the range of 0 to 10 Gy and was rather small (neutron/gamma-ray sensitivity in the range 0-0.2) at higher doses. This indicates that the method essentially provides information on the dose received from the gamma-ray component of the radiation.  相似文献   

11.
The neoplastic transformation of C3H mouse 10T1/2 cells was measured induced by fission-spectrum neutrons delivered at a high dose rate in five fractions over 4 days. The transformation frequency was significantly enhanced over that due to single equivalent total doses. These new data, in the low dose region, demonstrate an increased transformation frequency by fractionated versus single exposures of high-dose-rate fission-spectrum neutrons; an increase equal to that observed with low-dose-rate fission-spectrum neutrons (i.e., 0.086 rad/min). Estimates of the dose modifying factor (DMF), based upon the ratio of the initial linear portions of the induction curves for high and for low dose rates, suggest the same DMF (approximately 7.8) for both five daily fractions of high-dose-rate neutrons and for low-dose-rate neutrons. However, when these results are compared to those following high-dose-rate 60Co gamma rays (100 rad/min), the relative biological effectiveness (RBE) for low-dose-rate fission-spectrum neutrons based upon slope ratios is 19.6; similarly, the RBE relative to five daily fractions of 60Co gamma rays is 78.8.  相似文献   

12.
In order to provide fundamental data required for dose evaluation due to environmental exposures, effective dose conversion coefficients, that is, the effective dose rate per unit activity per unit area, were calculated for a number of potentially important radionuclides, assuming an exponential distribution in ground, over a wide range of relaxation depths. The conversion coefficients were calculated for adults and a new-born baby on the basis of dosimetric methods that the authors and related researchers have previously developed, using Monte Carlo simulations and anthropomorphic computational phantoms. The differences in effective dose conversion coefficients due to body size between the adult and baby phantoms were found to lie within 50?%, for most cases; however, for some low energies, differences could amount to a factor of 3. The effective dose per unit source intensity per area was found to decrease by a factor of 2–5, for increasing relaxation depths from 0 to 5?g/cm2, above a source energy of 50?keV. It is also shown that implementation of the calculated coefficients into the computation of the tissue weighting factors and the adult reference computational phantoms of ICRP Publication 103 does not significantly influence the effective dose conversion coefficients of the environment. Consequently, the coefficients shown in this paper could be applied for the evaluation of effective doses, as defined according to both recommendations of ICRP Publications 103 and 60.  相似文献   

13.

Background

Glioblastoma multiform (GBM) is the most common and most aggressive type of primary brain tumour in humans. It has a very poor prognosis despite multi-modality treatments consisting of open craniotomy with surgical resection, followed by chemotherapy and/or radiotherapy. Recently, a new treatment has been proposed – Boron Neutron Capture Therapy (BNCT) – which exploits the interaction between Boron-10 atoms (introduced by vector molecules) and low energy neutrons produced by giant accelerators or nuclear reactors.

Methods

The objective of the present study is to compute the deposited dose using a natural source of neutrons (atmospheric neutrons). For this purpose, Monte Carlo computer simulations were carried out to estimate the dosimetric effects of a natural source of neutrons in the matter, to establish if atmospheric neutrons interact with vector molecules containing Boron-10.

Results

The doses produced (an average of 1 μGy in a 1 g tumour) are not sufficient for therapeutic treatment of in situ tumours. However, the non-localised yet specific dosimetric properties of 10B vector molecules could prove interesting for the treatment of micro-metastases or as (neo)adjuvant treatment. On a cellular scale, the deposited dose is approximately 0.5 Gy/neutron impact.

Conclusion

It has been shown that BNCT may be used with a natural source of neutrons, and may potentially be useful for the treatment of micro-metastases. The atmospheric neutron flux is much lower than that utilized during standard NBCT. However the purpose of the proposed study is not to replace the ordinary NBCT but to test if naturally occurring atmospheric neutrons, considered to be an ionizing pollution at the Earth''s surface, can be used in the treatment of a disease such as cancer. To finalize this study, it is necessary to quantify the biological effects of the physically deposited dose, taking into account the characteristics of the incident particles (alpha particle and Lithium atom) and radio-induced effects (by-stander and low dose effect). One of the aims of the presented paper is to propose to experimental teams (which would be interested in studying the phenomena) a simple way to calculate the dose deposition (allometric fit of free path, transmission factor of brain).  相似文献   

14.
PurposeScanning proton therapy has dosimetric advantage over passive treatment, but has a large penumbra in low-energy region. This study investigates the penumbra reduction when multi-leaf collimators (MLCs) are used for line scanning proton beams and secondary neutron production from MLCs.MethodsScanning beam plans with and without MLC shaping were devised. Line scanning proton plan of 36 energy layers between 71.2 and 155.2 MeV was generated. The MLCs were shaped according to the cross-sectional target shape for each energy layer. The two-dimensional doses were measured through an ion-chamber array, depending on the presence of MLC field, and Monte Carlo (MC) simulations were performed. The plan, measurement, and MC data, with and without MLC, were compared at each depth. The secondary neutron dose was simulated with MC. Ambient neutron dose equivalents were computed for the line scanning with 10 × 10 × 5 cm3 volume and maximum proton energy of 150 MeV, with and without MLCs, at lateral distances of 25–200 cm from the isocenter. The neutron dose for a wobbling plan with 10 × 10 × 5 cm3 volume was also evaluated.ResultsThe lateral penumbra width using MLC was reduced by 23.2% on average, up to a maximum of 32.2%, over the four depths evaluated. The ambient neutron dose equivalent was 18.52% of that of the wobbling beam but was 353.1% larger than the scanning open field.ConclusionsMLC field shaping with line scanning reduced the lateral penumbra and should be effective in sparing normal tissue. However, it is important to investigate the increase in neutron dose.  相似文献   

15.
Selective irradiation of the vasculature of the rat spinal cord was used in this study, which was designed specifically to address the question as to whether it is the endothelial cell or the glial progenitor cell that is the target responsible for late white matter necrosis in the CNS. Selective irradiation of the vascular endothelium was achieved by the intraperitoneal (ip) administration of a boron compound known as BSH (Na(2)B(12)H(11)SH), followed by local irradiation with thermal neutrons. The blood-brain barrier is known to exclude BSH from the CNS parenchyma. Thirty minutes after the ip injection of BSH, the boron concentration in blood was 100 microg (10)B/ g, while that in the CNS parenchyma was below the detection limit of the boron analysis system, <1 microg (10)B/g. An ex vivo clonogenic assay of the O2A (oligodendrocyte-type 2 astrocyte) glial progenitor cell survival was performed 1 week after irradiation and at various times during the latent period before white matter necrosis in the spinal cord resulted in myelopathy. One week after 4.5 Gy of thermal neutron irradiation alone (approximately one-third of the dose required to produce a 50% incidence of radiation myelopathy), the average glial progenitor cell surviving fraction was 0.03. The surviving fraction of glial progenitor cells after a thermal neutron irradiation with BSH for a comparable effect was 0.46. The high level of glial progenitor cell survival after irradiation in the presence of BSH clearly reflects the lower dose delivered to the parenchyma due to the complete exclusion of BSH by the blood-brain barrier. The intermediate response of glial progenitor cells after irradiation with thermal neutrons in the presence of a boron compound known as BPA (p-dihydroxyboryl-phenylalanine), again for a dose that represents one-third the ED(50) for radiation-induced myelopathy, reflects the differential partition of boron-10 between blood and CNS parenchyma for this compound, which crosses the blood-brain barrier, at the time of irradiation. The large differences in glial progenitor survival seen 1 week after irradiation were also maintained during the 4-5-month latent period before the development of radiation myelopathy, due to selective white matter necrosis, after irradiation with doses that would produce a high incidence of radiation myelopathy. Glial progenitor survival was similar to control values at 100 days after irradiation with a dose of thermal neutrons in the presence of BSH, significantly greater than the ED(100), shortly before the normal time of onset of myelopathy. In contrast, glial progenitor survival was less than 1% of control levels after irradiation with 15 Gy of thermal neutrons alone. This dose of thermal neutrons represents the approximate ED(90-100) for myelopathy. The response to irradiation with an equivalent dose of X rays (ED(90): 23 Gy) was intermediate between these extremes as it was to thermal neutrons in the presence of BPA at a slightly lower dose equivalent to the approximate ED(60) for radiation myelopathy. The conclusions from these studies, performed at dose levels approximately iso-effective for radiation-induced myelopathy as a consequence of white matter necrosis, were that the large differences observed in glial progenitor survival were directly related to the dose distribution in the parenchyma. These observations clearly indicate the relative importance of the dose to the vascular endothelium as the primary event leading to white matter necrosis.  相似文献   

16.
PurposeTo investigate the dosimetric accuracy of synthetic computed tomography (sCT) images generated by a clinically-ready voxel-based MRI simulation package, and to develop a simple and feasible method to improve the accuracy.Methods20 patients with brain tumor were selected to undergo CT and MRI simulation. sCT images were generated by a clinical MRI simulation package. The discrepancy between planning CT and sCT in CT number and body contour were evaluated. To resolve the discrepancies, an sCT specific CT-relative electron density (RED) calibration curve was used, and a layer of pseudo-skin was created on the sCT. The dosimetric impact of these discrepancies, and the improvement brought about by the modifications, were evaluated by a planning study. Volumetric modulated arc therapy (VMAT) treatment plans for each patient were created and optimized on the planning CT, which were then transferred to the original sCT and the modified-sCT for dose re-calculation. Dosimetric comparisons and gamma analysis between the calculated doses in different images were performed.ResultsThe average gamma passing rate with 1%/1 mm criteria was only 70.8% for the comparison of dose distribution between planning CT and original sCT. The mean dose difference between the planning CT and the original sCT were −1.2% for PTV D95 and −1.7% for PTV Dmax, while the mean dose difference was within 0.7 Gy for all relevant OARs. After applying the modifications on the sCT, the average gamma passing rate was increased to 92.2%. Mean dose difference in PTV D95 and Dmax were reduced to −0.1% and −0.3% respectively. The mean dose difference was within 0.2 Gy for all OAR structures and no statistically significant difference were found.ConclusionsThe modified-sCT demonstrated improved dosimetric agreement with the planning CT. These results indicated the overall dosimetric accuracy and practicality of this improved MR-based treatment planning method.  相似文献   

17.
Human lymphocytes were irradiated in vitro during G0 stage by graded doses of thermal neutrons and of neutrons with mean energy of 0.04; 0.09; 0.35; 0.85 and 14.7 MeV as well as by 60Co gamma-rays. The data were fitted to the linear and linear-quadratic relations. The neutrons of low and intermediate energies showed the linear dependence on the dose, 14.7 MeV neutrons and gamma-rays--a linear-quadratic one, whereas the data obtained with 0.85 MeV neutrons fitted well the both models. Terminal and interstitial deletions produced by both gamma-rays and neutrons showed different dependencies upon the dose. Some qualitative pecularities of aberration spectra were found in the experiments with neutrons as compared with the data on gamma-irradiation: the ratio of exchanges to fragments was greater, and aberrations of chromatid type were produced. The specially designed experiments and calculations showed that the last effect was not connected with induced radioactivity.  相似文献   

18.
Summary When detailed neutron energy spectrum data are lacking for a mixed field of neutrons and photons, it is permissible when estimating the dose equivalent to assume that the quality factor for the neutrons is 10. With this assumption, it is shown that the responses of a tissue-equivalent ionization chamber and a Geiger-Müller dosimeter can be used to obtain an acceptable approximation of the dose equivalent in the mixed field without requiring precise knowledge of the relative neutron sensitivity of the Geiger-Müller dosimeter.This investigation was supported by Contract EP-78-S-02-4733 from the Department of Energy to the Radiological Research Laboratory/Department of Radiology and by Grant No. CA13696 to the Cancer Center/Institute of Cancer Research, awarded by National Cancer Institute, DHEW  相似文献   

19.
The Comet assay (microgel electrophoresis) was used to study DNA damage in Raji cells, a B-lymphoblastoid cell line, after treatment with different doses of neutrons (0.5 to 16 Gy) or gamma rays (1.4 to 44.8 Gy). A better growth recovery was observed in cells after gamma-ray treatments compared with neutron treatments. The relative biological effectiveness (RBE) of neutron in cell killing was determined to be 2.5. Initially, the number of damaged cells per unit dose was approximately the same after neutron and gamma-ray irradiation. One hour after treatment, however, the number of normal cells per unit dose was much lower for neutrons than for gamma rays, suggesting a more efficient initial repair for gamma rays. Twenty-four hours after treatment, the numbers of damaged cells per unit dose of neutrons or gamma rays were again at comparable level. Cell cycle kinetic studies showed a strong G2/M arrest at equivalent unit dose (neutrons up to 8 Gy; gamma rays up to 5.6 Gy), suggesting a period in cell cycle for DNA repair. However, only cells treated with low doses (up to 2 Gy) seemed to be capable of returning into normal cell cycle within 4 days. For the highest dose of neutrons, decline in the number of normal cells seen at already 3 days after treatment was deeper compared with equivalent unit doses of gamma rays. Our present results support different mechanisms of action by these two irradiations and suggest the generation of locally multiply damaged sites (LMDS) for high linear energy transfer (LET) radiation which are known to be repaired at lower efficiency.  相似文献   

20.
The risks and dose conversion coefficients for residential and occupational exposures due to radon were determined with applying the epidemiological risk models to ICRP representative populations. The dose conversion coefficient for residential radon was estimated with a value of 1.6 mSv year?1 per 100 Bq m?3 (3.6 mSv per WLM), which is significantly lower than the corresponding value derived from the biokinetic and dosimetric models. The dose conversion coefficient for occupational exposures with applying the risk models for miners was estimated with a value of 14 mSv per WLM, which is in good accordance with the results of the dosimetric models. To resolve the discrepancy regarding residential radon, the ICRP approaches for the determination of risks and doses were reviewed. It could be shown that ICRP overestimates the risk for lung cancer caused by residential radon. This can be attributed to a wrong population weighting of the radon-induced risks in its epidemiological approach. With the approach in this work, the average risks for lung cancer were determined, taking into account the age-specific risk contributions of all individuals in the population. As a result, a lower risk coefficient for residential radon was obtained. The results from the ICRP biokinetic and dosimetric models for both, the occupationally exposed working age population and the whole population exposed to residential radon, can be brought in better accordance with the corresponding results of the epidemiological approach, if the respective relative radiation detriments and a radiation-weighting factor for alpha particles of about ten are used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号