1.
In order to measure changes in physiological CO concentrations in blood with good accuracy, a method was developed using gas chromatography with flame ionisation detection (250 degrees C). A nickel catalyst system was fitted to convert CO to methane at 375 degrees C after separation with a molecular sieve column at 35 degrees C. Helium was used as carrier at 30 ml/min. Porcine or human blood (400 microl) was sampled in gastight tubes and treated with sulfuric acid and saponin (800 microl). Accuracy was 1.4% and 1.5% (RSD), respectively. Precision was 2.8% (porcine blood). Limit of detection was 0.01 nmol/ml gas and limit of quantification 12 nmol/ml blood. Calibration was made in the interval 12-514 nmol/ml blood (corresponding to 0.1-6% COHb). Samples were stable for at least a month at +4 degrees C. This paper describes a method with high sensitivity and good accuracy, suitable for analysis of low CO concentrations.  相似文献   

2.
A rapid, sensitive and selective gas chromatographic method with flame ionization detection was developed for the determination of paraldehyde in small blood samples taken from children. Whole blood samples (300 microl) collected in a 3 ml Wheaton glass sample vial were spiked with acetone (internal standard: 15 ng) followed by addition of concentrated hydrochloric acid. The mixture was heated in the sealed airtight sample vial in a water bath (96 Celsius; 5 min) to depolymerize paraldehyde to acetaldehyde. A 2 ml aliquot of the headspace was analyzed by gas chromatography with flame ionization detector using a stainless steel column (3 m x 4 mm i.d.) packed with 10% Carbowax 20 M/ 2% KOH on 80/100 Chromosorb WAW. Calibration curves were linear from 1.0-20 microg (r2>0.99). The limit of detection was 1.5 microg/ml, while relative mean recoveries at 2 and 18 microg were 105.6 +/- 8.4 and 101.2 +/- 5.9%, respectively (n = 10 for each level). Intra- and inter-assay relative standard deviations at 2, 10 and 18 microg were <15%. There was no interference from other drugs concurrently used in children with severe malaria, such as anticonvulsants (diazepam, phenytoin, phenobarbitone), antipyretics/analgesics (paracetamol and salicylate), antibiotics (gentamicin, chloramphenicol, benzyl penicillin) and antimalarials (chloroquine, quinine, proguanil, cycloguanil, pyrimethamine and sulfadoxine). The method was successfully applied for pharmacokinetic studies of paraldehyde in children with convulsions associated with severe malaria.  相似文献   

3.
The purpose of this study was to develop a simple and accurate analytical method to determine amino acids in urine samples. The developed method involves the employment of an extract derivatization technique together with gas chromatography-mass spectrometry (GC-MS). Urine samples (300 microl) and an internal standard (10 microl) were placed in a screw tube. Ethylchloroformate (50 microl), methanol-pyridine (500 microl, 4:1, v/v) and chloroform (1 ml) were added to the tube. The organic layer (1 microl) was injected to a GC-MS system. In this proposed method, the amino acids in urine were derivatized during an extraction, and the analytes were then injected to GC-MS without an evaporation of the organic solvent extracted. Sample preparation was only required for ca. 5 min. The 15 amino acids (alanine, aspartic acid, cysteine, glutamic acid, glycine, histidine, isoleucine, leucine, lysine, methionine, phenylalanine, proline, tyrosine, tryptophan, valine) quantitatively determined in this proposed method. However, threonine, serine, asparagine, glutamine, arginine were not derivatized using any tested derivatizing reagent. The calibration curves showed linearity in the range of 1.0-300 microg/ml for each amino acid in urine. The correlation coefficients of the calibration curves of the tested amino acids were from 0.966 to 0.998. The limit of detection in urine was 0.5 microg/ml except for aspartic acid. This proposed method demonstrated substantial accuracy for detection of normal levels. This proposed method was limited for the determination of 15 amino acids in urine. However, the sample preparation was simple and rapid, and this method is suitable for a routine analysis of amino acids in urine.  相似文献   

4.
A sensitive and reproducible high performance liquid chromatography method with UV detection was described for the determination of aesculin in rat plasma. After deproteinization by methanol using metronidazole as internal standard (I.S.), solutes were evaporated to dryness at 40 degrees C under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of mobile phase and a volume of 20 microl was injected into the HPLC for analysis. Solutes were separated on a Diamonsil C18 column (250 mm x 4.6 mm i.d., 5 microm particle size, Dikma) protected by a ODS guard column (10 mm x 4.0 mm i.d., 5 microm particle size), using acetonitrile-0.1% triethylamine solution (adjusted to pH 3.0 using phosphoric acid) (10:90, v/v) as mobile phase (flow-rate 1.0 ml/min), and wavelength of the UV detector was set at 338 nm. No interference from any endogenous substances was observed during the elution of aesculin and internal standard (I.S., metronidazole). The retention times for I.S and aesculin were 10.4 and 12.4 min, respectively. The limit of quantification was evaluated to be 57.4 ng/ml and the limit of detection was 24.0 ng/ml. The method was used in the study of pharmacokinetics of aesculin after intraperitoneal injection (i.p.) administration in rats.  相似文献   

5.
Iodixanol is a widely used iso-osmolar contrast medium agent. Similar to iohexol, it can also be a good exogenous marker for the measurement of glomerular filtration rate (GFR). This article describes the development and validation of an HPLC-UV method for quantification of iodixanol in human plasma. Internal standard, iohexol (20 microl, 1 mg/ml), and perchloric acid (30 microl, 20%, v/v) were added to plasma samples (300 microl), followed by neutralization with 10 microl potassium carbonate (5M). Samples were centrifuged and 10 microl of the supernatant was injected onto a C(18) EPS analytical column (3 microm particle size, 150 mm x 4.6 mm). The extraction method yielded >95% recovery for both iodixanol and iohexol. The mobile phase consisted of 0.1% (w/v) sodium formate buffer and acetonitrile. Iohexol and iodixanol peaks were eluted at approximately 5 and 9 min, respectively using a fast gradient method. The assay lower limit of detection was 2.0 microg/ml and lower limit of quantification was 10 microg/ml. The calibration curves, assessed in six replicates, were linear over an iodixanol concentration range of 10-750 microg/ml. Intra- and inter-day accuracy was >95% and precision expressed as % coefficient of variation was <10%. This method is simple, accurate, precise and robust and can potentially be used for iodixanol quantification in large-scale clinical studies.  相似文献   

6.
A simple and rapid method was applied for direct measurement of nitric oxide (NO) gas produced by cultured macrophages using a modified chemiluminescence detector, the thermal energy analyzer (TEA). HD11 chicken macrophages (1-3 x 10(6)/ml) were cultured on microcarrier beads (100 mg/ml) in 140 ml air-tight glass jars (5 ml cell suspension per jar) containing 0.5 micrograms/ml of LPS and different concentrations of L-arginine. Headspace gas was sampled at 24 hours of culture via a rubber septum and directly injected into a TEA with a liquid nitrogen trap set at -130 to -140 degrees C. The concentration of NO in the gas sample was quantified using a standard gas mixture of NO (2 microliters/L) in nitrogen. Gas samples from L-arginine-supplemented cultures contained NO (0.028-0.066 pl/microliter), whereas NO was not detected in samples from controls. These results suggest that chicken macrophages synthesize NO gas in a dose-dependent manner relative to L-arginine concentration.  相似文献   

7.
We have established an ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood sample containing ethanol and isobutyl alcohol (internal standard, IS) in a 7.0-ml vial at 55°C for 15 min, 5 ml of the headspace vapor was drawn into a glass syringe and injected into a GC port. All vapor was introduced into an Rtx-BAC2 wide-bore capillary column in the splitless mode at −60°C oven temperature to trap entire analytes, and then the oven temperature was programmed up to 240°C for GC measurements with flame ionization detection. The present method gave sharp peaks of ethanol and IS, and low background noise for whole blood samples. The mean partition into the gaseous phase for ethanol and IS was 3.06±0.733 and 8.33±2.19%, respectively. The calibration curves showed linearity in the range 0.02–5.0 μg/ml whole blood. The detection limit was estimated to be 0.01 μg/ml. The coefficients of intra-day and inter-day variation for spiked ethanol were 8.72 and 9.47%, respectively. Because of the extremely high sensitivity, we could measure low levels of endogenous ethanol in whole blood of subjects without drinking. The concentration of endogenous ethanol measured for 10 subjects under uncontrolled conditions varied from 0 to 0.377 μg/ml (mean, 0.180 μg/ml). Data on the diurnal changes of endogenous ethanol in whole blood of five subjects under strict food control are also presented; they are in accordance with the idea that endogenous blood ethanol is of enteric bacterial origin.  相似文献   

8.
A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 microl plasma of rats. Sample preparation was carried out by deproteinization with 100 microl of acetonitrile. A 20 microl of supernatant was directly injected into the HPLC system with methanol-double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a microBondapak C(18) column at 30 degrees C. The peak was detected at 278 nm. The calibration curve was linear (r(2)=0.9989) in the concentration range of 0.028-2.80 microg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.  相似文献   

9.
产气荚膜梭菌实时荧光PCR方法的建立   总被引:3,自引:0,他引:3  
目的:利用荧光定量PCR技术,建立快速敏感特异的检测产气荚膜梭菌的方法。方法:以产气荚膜梭菌基因为靶序列设计引物和探针,以自产气荚膜梭菌菌株中提取的DNA为模板,优化引物和探针的浓度比,同时验证方法的特异性、敏感性。结果:建立的反应体系在上游引物浓度为0.45μmol/L、下游引物浓度为0.15μmol/L、探针浓度为0.3μmol/L时,具有良好的特异性和敏感性,与创伤弧菌等12种相关细菌均无交叉反应;对纯菌检测的灵敏度低于10 CFU/反应体系。结论:建立的实时荧光PCR方法特异、灵敏、快速,能对战时气性坏疽做出快速准确的报告,实现对这种战时高发疾病的安全、快速和定量检测。  相似文献   

10.
Measurements of nitric oxide (NO) pulmonary diffusing capacity (DL(NO)) multiplied by alveolar NO partial pressure (PA(NO)) provide values for alveolar NO production (VA(NO)). We evaluated applying a rapidly responding chemiluminescent NO analyzer to measure DL(NO) during a single, constant exhalation (Dex(NO)) or by rebreathing (Drb(NO)). With the use of an initial inspiration of 5-10 parts/million of NO with a correction for the measured NO back pressure, Dex(NO) in nine healthy subjects equaled 125 +/- 29 (SD) ml x min(-1) x mmHg(-1) and Drb(NO) equaled 122 +/- 26 ml x min(-1) x mmHg(-1). These values were 4.7 +/- 0.6 and 4.6 +/- 0.6 times greater, respectively, than the subject's single-breath carbon monoxide diffusing capacity (Dsb(CO)). Coefficients of variation were similar to previously reported breath-holding, single-breath measurements of Dsb(CO). PA(NO) measured in seven of the subjects equaled 1.8 +/- 0.7 mmHg x 10(-6) and resulted in VA(NO) of 0.21 +/- 0.06 microl/min using Dex(NO) and 0.20 +/- 0.6 microl/min with Drb(NO). Dex(NO) remained constant at end-expiratory oxygen tensions varied from 42 to 682 Torr. Decreases in lung volume resulted in falls of Dex(NO) and Drb(NO) similar to the reported effect of volume changes on Dsb(CO). These data show that rapidly responding chemiluminescent NO analyzers provide reproducible measurements of DL(NO) using single exhalations or rebreathing suitable for measuring VA(NO).  相似文献   

11.
A sensitive, specific and reproducible method for the quantitative determination of kavain in human hair has been developed. The sample preparation involved a decontamination step of the hair with methylene chloride. The hair sample (about 50 mg) was incubated in 1 ml of methanol for 1 h, in an ultrasonic bath, in presence of 20 ng of methaqualone-d7 used as internal standard. The methanolic solution was evaporated to dryness, and the residue reconstituted by adding 30 microl of methanol. A 2 microl aliquot of the extract was injected onto the column (Optima5-MS capillary column, 5% phenyl-95% methylsiloxane, 30 m x 0.25 mm i.d. x 0.25 mm film thickness) of a Hewlett-Packard (Palo Alto, CA) gas chromatograph (5890). Kavain was detected by its parent ion at m/z 230 and daughter ions at m/z 111 and 202 through a Finnigan TSQ 700 MS/MS system. The assay was capable of detecting 30 pg/mg of kavain (limit of detection (LOD)). Linearity was observed for kavain concentrations ranging from 100 to 2000 pg/mg with a correlation coefficient of 0.998. Intra-day precision at 400 pg/mg was 13.7%. The analysis of a segment of hair, obtained from an occasional consumer, revealed the presence of kavain at the concentration of 418 pg/mg. A higher concentration (1708 pg/mg) was detected in the corresponding pubic hair.  相似文献   

12.
F2-isoprostanes are produced by the non-enzymatic peroxidation of arachidonic acid in membrane phospholipids. This paper describes a new method for the determination of all four classes of F2-isoprostanes in human cerebrospinal fluid (CSF) involving separation on a 1 mm x 150 mm porous graphitic carbon (PGC) column and detection by triple quadrupole mass spectrometry in negative-ion electrospray mode. The sample pre-treatment consisted of an ultrafiltration step, following which 300 microl of CSF sample could be injected directly onto a 1 mm x 10 mm PGC guard column functioning as a trap for the analytes. The loading solvent was Milli-Q water at 125 microl/min. After 3 min, the sample was switched into the separation column. The F2-isoprostanes were separated in 20 min using a linear solvent gradient comprising water, methanol, acetonitrile and ammonium hydroxide at a pH of 9.5 and a flow of 50 microl/min The limit of detection (calculated as 3S/N) was approximately 40 pM (14 pg/ml). The assay was linear within the examined range (18-450 pg/ml), using CSF spiked with iPF2alpha-III standard (r(2)>0.995). Repeatability data were calculated for CSF spiked to 90 pg/ml and the relative standard deviation (RSD) obtained was 3% (n=6).  相似文献   

13.
Andoh T 《Zoological science》2005,22(9):1023-1030
A time-resolved fluoroimmunoassay system (TR-FIA) for measuring flounder insulin-like growth factor-I (IGF-I) was developed using biotinylated flounder IGF-I, anti-fish IGF-I antiserum and europium-avidin conjugate. The detection limit per well was <5 pg/well corresponding to <0.5 ng/ml in a basic procedure for sample of 10 microl/well and to <0.08 ng/ml in a procedure modified for high volume samples (up to 70 microl/well). Specificity of the assay was validated using various IGF-Is and insulins. All IGFs except seabream IGF-I showed very low or no crossreactivity. Binding inhibition curves for flounder and seabream IGF-Is were completely identical to each other. Intra- and interassay variations ranged from coefficients of variations of 3.9% to 7.2%. Recovery tests using barfin flounder plasma varied from 82.7 to 101.6% in the added range from 20 to 160 ng/ml. This assay system was applied for measuring total plasma IGF-I in barfin flounder injected porcine growth hormone (GH). A group injected with GH at the dose of 0.05 IU/gBW showed a significant increase of total plasma IGF-I compared with those of albumin-injected (control) and initial groups. In addition, I was able to substitute time-resolved fluorometric detection in this assay system with enzymatic fluorometric detection (FIA). Binding inhibition curve for flounder IGF-I in this substituted assay system showed equal performance with that of the TR-FIA system. Correlation of IGF-I levels between TR-FIA and FIA was high (r(2)=0.957) in plasma samples from barfin flounders in various physiological conditions. Thus, the present study shows precision and efficiency of two non-radioisotopic immunoassay systems for measuring flounder IGF-I.  相似文献   

14.
The objective of this study was to develop an assay system that allows continuous monitoring of nitric oxide (NO) released from crystalloid perfused hearts. We utilized chemiluminescence reaction between NO and luminol-H(2)O(2) to quantify the NO level in coronary effluent. Isolated rat hearts were subjected to ordinary Langendorff's perfusion, and the right ventricle was cannulated to sample coronary effluent. After equilibration, the coronary flow rate was set constant and the hearts were paced at 300 bpm. Coronary effluent was continuously sampled and mixed with the chemiluminescent probe containing 0.018 mmol/l luminol plus 10 mmol/l H(2)O(2). Chemiluminescence from the mixture of coronary effluent and the probe was continuously measured. NO concentration was calibrated by various concentrations (0.5-400 pmol/l) of standard NO solution. The lower detection limit of NO was 1 pmol/l. Basal NO release from isolated perfused rat heart was 0.41 +/- 0.17 pmol/min/g of heart weight, and that was significantly suppressed by 0.1 mmol/l of L-NAME to 0.18 +/- 0.10 pmol/min/g of heart weight (n = 7). Application of 0.1 and 0.3 micromol/l acetylcholine increased NO level in the coronary effluent, in a concentration-dependent manner, from 6.6 +/- 1.7 in a baseline condition to 16.3 +/- 7.4 and 30.3 +/- 16.1 pmol/l at each peak, respectively. Thrombin at 1 and 10 U/ml also increased NO level from 17.6 +/- 4.3 in control to 35.5 +/- 10.4 and 48.7 +/- 8.7 pmol/l at each peak, respectively (n = 7). Thus, this assay system is applicable to the continuous real-time measurement of NO released from crystalloid perfused hearts, and it may be useful for the study of physiological or pathophysiological role of NO in coronary circulation.  相似文献   

15.
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-day and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 microl plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 microl of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively.  相似文献   

16.
Study of the effect of atmospheric relative humity (RH) on the adsorption of paraformaldehyde-generated formaldehyde gas on various surfaces and the effect of the adsorbed formaldehyde on the death rate of bacterial spores showed that increasing the RH caused a corresponding increase of formaldehyde levels on all surfaces. The amount peaked at 83% RH. The levels obtained at 100% RH were slightly below those at 83% RH. Cotton cloth had a much greater affinity for the gas at all RH than either glass or stainless steel. The death rate of bacterial spores on surfaces containing adsorbed formaldehyde was high for the first hour after removal from the formaldehyde atmosphere but decreased rapidly thereafter. This held true for both cotton and glass surfaces. Also, formaldehyde levels of 15 to 27 mug/ml of nutrient broth caused inhibition of bacterial growth, but levels above 27 mug/ml rendered broth sterile.  相似文献   

17.
A method for the detection of the nitric oxide radical (NO) in oxygen-containing aqueous solution by means of electron paramagnetic resonance spectroscopy (EPR) is described. NO evolving from the spontaneous decomposition of 3-morpholinosydnonimine (SIN-1) was trapped by Fe(2+)-diethyldithiocarbamate (DETC) complex dissolved in yeast cell membranes. The resulting mononitrosyl-Fe(2+)-(DETC)2 complex was stable and exhibited a characteristic EPR signal at g perpendicular = 2.04 and g parallel = 2.02 with an unresolved triplet hyperfine structure at g perpendicular in frozen solution and an isotropic triplet signal at gav = 2.03 at 37 degrees C. The amount of NO trapped was calculated from the amplitude of one of the triplet lines calibrated by means of a dinitrosyl-Fe(2+)-thiosulfate standard. The lower detection limit of NO was 0.5 nmol/(ml x h) due to a low background NO signal. The upper detection limit was about 10 nmol NO/40 mg traps (DETC-loaded yeast cells), because of saturation of traps. The trapping efficiency approached 60% under anaerobic conditions and with low concentrations of SIN-1, but decreased progressively with higher concentrations and in the presence of oxygen. Nitrite (up to 0.1 mM) did not increase the background NO level. The sensitivity was sufficient to follow the rate of NO release from SIN-1 on-line at 37 degrees C in a flat quartz cuvette. The time course of NO release detected by EPR spectrometry correlated with the time course of nitrite accumulation measured by diazotation. In conclusion, this method will permit the on-line detection of NO formation from endogenous and pharmacological sources in oxygen-containing aqueous media.  相似文献   

18.
Methotrexate (MTX) has been widely used at low dose for the treatment of different diseases including rheumatoid arthritis. MTX might be present in plasma in free form, and in blood cells in methotrexate polyglutamate (MTXPG). A rapid and sensitive HPLC method was developed for the determination of plasma MTX level, whole-blood MTX level, and whole-blood total MTX (MTX+MTXPG) level. To determine plasma MTX level or whole-blood MTX level, a 0.2-ml aliquot of plasma or whole blood (after a freeze-thaw cycle to break blood cells) was well mixed with 0.8 ml methanol and centrifuged. To determine whole-blood total MTX level, a 0.1-ml aliquot of whole blood (after a freeze-thaw cycle) was mixed with 80 microl ascorbic acid (114 mM) and incubated at 37 degrees C for 2h to enzymatically convert the MTXPG to MTX. Then 20 microl NaOH solution (0.5M) and 0.8 ml methanol were added and mixed well. After centrifugation, a 0.5-ml aliquot of the supernatant was evaporated to dryness and re-dissolved in 0.2 ml hydrochloric acid (10mM). Methylene chloride (0.2 ml) was added and mixed well. After centrifugation, the top aqueous layer was injected to HPLC for analysis. After the MTX was eluted from the HPLC column, it was electrochemically oxidized and detected by a fluorescence detector. Recoveries of spiked MTX at ppb (ng/ml) level were between 87.9 and 118% with within-day relative standard deviation less than 5.2% and day-to-day relative standard deviation less than 9.8%. The limit of detection (LOD) and limit of quantitation (LOQ) of the described method were 1.2 and 2.6 ng/ml, respectively.  相似文献   

19.
A high performance liquid chromatography (HPLC) method using fluorescence detection to determine 3-amino-5-mercapto-1,2,4-triazole (AMT) levels in serum has been developed. Sample preparation involved treatment with tributylphosphine (TBP) to reduce disulfides formed during storage, precipitation of proteins with acetonitrile (ACN), and precolumn derivatization using the thiol reactive fluorescent probe monobromobimane (MBB). The conjugate (AMT-MBB) was resolved by gradient elution from a C(18) reversed-phase column. The assay method was linear over a concentration range of 0.78-50 microg/ml and had a limit of detection (LOD) of 0.05 microg/ml AMT (10 microl injection). This method provides a sensitive and specific tool for the determination of AMT in serum and may have potential industrial hygiene application.  相似文献   

20.
Simultaneous removal of NO(x) and SO2 from exhausted gas were investigated by studying co-culture of sulfate reducing bacteria and anaerobic denitrifying bacteria, separated from landfill leachate. When H2S, generated by sulfate reducing bacteria was chosen as the sole electron donor for anaerobic denitrifying bacteria, the co-culture system demonstrated a faster NO removal rate, higher stability and better permanence. When the feed gas flow rates of N2 and SO2 were maintained constant at 0.1 m3/h and 16 ml/min respectively, the maximum NO-removal rate could be achieved at over 92% with NO feed gas kept between 2-6 ml/min, while the SO2 removal rate was always above 95%. Long-term continuous removal of NO exhibited an evident periodicity of five days, however, the fluctuation range of NO-removal was decreasing. Moreover, the decrease of the gas flow rate and the increase in NO inlet concentration could contribute to a higher NO- removal rate.  相似文献   