1.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

2.
A simple and reliable method for analyzing the concentrations of clozapine and its biologically active metabolite, norclozapine, in human serum or plasma has been developed. This method is based on reversed-phase high-performance liquid chromatography (HPLC) with automated solid-phase extraction (SPE). For HPLC analysis, samples and standards are prepared with an ASPEC automatic sample preparator using 100 mg Bond-Elut C18 SPE columns. The HPLC assay is an isocratic method with a mobile phase of acetonitrile-methanol-10 mM dipotassium hydrogenphosphate, pH 3.7 (30:2:100, v/v/v) at a flow-rate of 1.5 ml/min with a C18 reversed-phase column. Detection is performed with a diode array detector set at 220 nm and with peak purity analyses at 210–365 nm. The absolute recovery varied from 85 and 95%. The intra-assay coefficients of variation (C.V.s) were from 4.2 and 8.0% and the inter-assay C.V.s were from 1.1. to 9.3% at therapeutic drug concentrations. The detection limit is 15 nmol/l. The method has been developed for use in a clinical laboratory for therapeutic drug monitoring.  相似文献   

3.
A sensitive method was developed and validated for the measurement of 17-(allylamino)-17-demethoxygeldanamycin (17AAG) and its active metabolite 17-amino-17-demethoxygeldanamycin (17AG) in human plasma using 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17DMAG) as an internal standard. After the addition of internal standard, 200 microL of plasma was extracted using ice cold acetonitrile followed by analysis on a Thermo Finnigan triple-quadruple mass spectrometer coupled to an Agilent 1100 HPLC system. Chromatography was carried out on a 50 mm x 2.1 mm Agilent Zorbax SB-phenyl 5 microm column coupled to a 3mm Varian metaguard diphenyl pre-column using glacial acetic acid 0.1% and a gradient of acetonitrile and water at a flow rate of 500 microL/min. Atmospheric pressure chemical ionization and detection of 17AAG, 17AG and 17DMAG were accomplished using selected reaction monitoring of m/z 584.3>541.3, 544.2>501.2, and 615.3>572.3, respectively in negative ion mode. Retention times for 17AAG, 17AG, and 17DMAG were 4.1, 3.5, and 2.9 min, respectively, with a total run time of 7 min. The assay was linear over the range 0.5-3000 ng/mL for 17AAG and 17AG. Replicate sample analysis indicated within- and between-run accuracy and precision within 15%. The recovery of 17AAG and 17AG from 200 microL of plasma containing 1, 25, 300, and 2500 ng/mL was 93% or greater. This high-performance liquid chromatographic tandem mass spectroscopy (HPLC/MS/MS) method is superior to previous methods. It is the first analytical method reported to date for the quantitation of both 17AAG and its metabolite 17AG and can reliably quantitate concentrations of both compounds as low as 0.5 ng/mL.  相似文献   

4.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

5.
A high-performance liquid chromatographic method was developed for the determination of a new non-narcotic analgesic, DA-5018 (I), in rat plasma, urine and bile samples, using propranolol for plasma samples and protriptyline for urine and bile samples as internal standards. The method involved extraction followed by injection of 100 μl of the aqueous layer onto a C18 reversed-phase column. The mobile phases were 5 mM methanesulfonic acid with 10 mM NaH2PO4 (pH 2.5)-acetonitrile, 70:30 (v/v) for plasma samples and 75:25 (v/v) for urine and bile samples. The flow-rates were 1.0 ml/min for plasma samples and 1.2 ml/min for urine and bile samples. The column effluent was monitored by a fluorescence detector with an excitation wavelength of 270 nm and an emission wavelength of 330 nm. The retention time for I was 4.8 min in plasma samples and 10.0 min in urine and bile samples. The detection limits for I in rat plasma, urine and bile were 20, 100 and 100 ng/ml, respectively. There was no interference from endogenous substances.  相似文献   

6.
A facile, sensitive and highly specific HPLC method for assaying 1-(2-chloroethyl)-3-sarcosinamide-1-nitrosourea (SarCNU) in plasma has been developed. The drug was efficiently isolated from plasma by extraction with tert.-butyl methyl ether. A structurally related compound with similar physicochemical properties served as the internal standard (I.S.). Following evaporation of the organic solvent, the extract was reconstituted with 0.05 M ammonium acetate buffer, pH 5.0, and loaded onto a 4 μm Nova-Pak C18 column (15 cm×3.9 mm), which was preceded by a 7 μm Brownlee RP-18 precolumn (1.5 cm×3.2 mm). Chromatography was performed at ambient temperature using a mobile phase of methanol-0.1 M ammonium formate buffer, pH 3.7 (25:75, v/v). UV absorbance of the effluent was monitored at 240 nm. A flow-rate of 1.0 ml/min was used for analyzing mouse and dog plasma extracts. Under these conditions, the drug eluted at 4.0 min and was followed by the I.S. at 6.1 min. An automatic switching valve was employed to allow the precolumn to be flushed 1.5 min into the run, without interrupting the flow of the mobile phase to the analytical column, thereby preventing the apparent build-up of extractable, strongly retained, UV-absorbing components present in mouse and dog plasma. Operating in this manner, more than 100 samples could be analyzed during a day using a refrigerated autosampler for overnight injection. The method was readily adapted to the determination of SarCNU in human plasma by simply decreasing the eluent flow-rate to 0.6 ml/min, whereby SarCNU and the I.S. eluted at approximately 5.8 and 9.1 min, respectively. Furthermore, the switching valve was not necessary for the analysis of human plasma samples. With a 50-μl sample volume, the lowest concentration of SarCNU included in the plasma standard curves, 0.10 μg/ml, was quantified with a 7.8% R.S.D. (n=27) over a 2 month period. Plasma standards, with concentrations of 0.26 to 5.1 μg/ml, exhibited R.S.D. values ranging from 1.3 to 4.7%. Thermospray-ionization MS detection was used to definitively establish the specificity of the method. The sensitivity of the assay was shown by application to be more than adequate for characterizing the plasma pharmacokinetics of SarCNU in mice.  相似文献   

7.
We extended the application of a sensitive high-performance liquid chromatography assay of amoxicillin developed in this laboratory for human plasma and middle ear fluid (MEF) to other sample matrices including chinchilla plasma or MEF and human and chinchilla whole blood with minor modification and validated the limit of quantitation at 0.25 μg/ml with a 50-μl sample size for human and chinchilla plasmas or MEFs. Amoxicillin and cefadroxil, the internal standard, were extracted from 50 μl of the samples with Bond Elut C18 cartridges. The extract was analyzed on a Keystone MOS Hypersil-1 (C8) column with UV detection at 210 nm. The mobile phase was 6% acetonitrile in 5 mM phosphate buffer, pH 6.5 and 5 mM tetrabutylammonium. The within-day coefficients of variation were 2.7–9.9 (n=4) and 1.7–7.2% (n=3) for chinchilla plasma and MEF samples, respectively; 2.8–8.1% (n=3) and 2.9–4.7% (n=3) for human and chinchilla whole blood, respectively. An alternative mobile phase composition for chinchilla plasma and MEF samples reduced the analysis time significantly.  相似文献   

8.
Measurement of nitrite and nitrate, the stable oxidation products of nitric oxide (NO), provides a useful tool to study NO synthesis in vivo and in cell cultures. A simple and rapid fluorometric HPLC method was developed for determination of nitrite through its derivatization with 2,3-diaminonaphthalene (DAN). Nitrite, in standard solution, cell culture medium, or biological samples, readily reacted with DAN under acidic conditions to yield the highly fluorescent 2,3-naphthotriazole (NAT). For analysis of nitrate, it was converted to nitrite by nitrate reductase, followed by the derivatization of nitrite with DAN to form NAT. NAT was separated on a 5-μm reversed-phase C8 column (150×4.6 mm, I.D.) guarded by a 40-μm reversed-phase C18 column (50×4.6 mm, I.D.), and eluted with 15 mM sodium phosphate buffer (pH 7.5) containing 50% methanol (flow-rate, 1.3 ml/min). Fluorescence was monitored with excitation at 375 nm and emission at 415 nm. Mean retention time for NAT was 4.4 min. The fluorescence intensity of NAT was linear with nitrite or nitrate concentrations ranging from 12.5 to 2000 nM in water, cell culture media, plasma and urine. The detection limit for nitrite and nitrate was 10 pmol/ml. Because NAT is well separated from DAN and other fluorescent components present in biological samples, our HPLC method offers the advantages of high sensitivity and specificity as well as easy automation for quantifying picomole levels of nitrite and nitrate in cell culture medium and biological samples.  相似文献   

9.
A method is reported for the measurement of quercetin in human plasma using reversed-phase high-performance liquid chromatography (HPLC). Quercetin and kaempferol (as internal standard) were spiked into plasma samples and extracted using C18 Sep-Pak Light cartridges (efficiency > 85%). Flavonoids were eluted with aqueous acetone (50% v/v, pH 3.5), dried down and redissolved in aqueous acetone (45% v/v, pH 3.5). The increased osmolarity promoted a phase separation and the water-saturated acetone layer, containing the flavonoids, was analysed by HPLC with aqueous acetone mobile phase (45% v/v acetone in 250 mM sodium dihydrogen sulphate. The mixture was adjusted to pH 3.5 with phosphoric acid and used at a flow-rate of 1.0 ml/min) and μBondapak C18 column (150 × 3.9 mm I.D., 10 μm particle size). The detection limit (A375 nm) for quercetin in plasma was 0.1 μg/ml (300 nM). The method also detects metabolites of quercetin, although these are not yet identified.  相似文献   

10.
A selective HPLC method is described for the determination of cefpodoxime levels in plasma and sinus mucosa. Sample preparation included solid-phase extraction with a C8 cartridge. Cefpodoxime and cefaclor (internal standard) were eluted with methanol and analyzed on an optimised system consisting of a C18 stationary phase and a ternary mobile phase (0.05 M acetate buffer pH 3.8—methanol—acetonitrile, 87:10:3, v/v) monitored at 235 nm. Linearity and both between- and within-day reproducibility were assessed for plasma and sinus mucosa samples. Inter-assay coefficients of variation were lower than 13.6% (n = 10) for plasma (0.2 μg/ml) and lower than 12.4% (n = 5) for sinus mucosa (0.25 μg/g). The quantification limit was 0.05 μg/ml for plasma and 0.13 μg/g for tissue. The method was used to study the diffusion of cefpodoxime in sinus mucosa.  相似文献   

11.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

12.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

13.
A stereoselective and sensitive achiral/chiral method for the determination of terfenadine acid metabolite in human plasma was developed. The metabolite was separated and quantitated using an achiral chromatographic procedure with a cyano column. The mobile phase was 1 mM sodium acetate buffer (pH 4.0) and acetonitrile (25:75% v/v) at a flow rate of 2 ml/min, at ambient temperature. The stereospecific resolution was accomplished using a chiral-AGP column and a mobile phase consisting of sodium acetate (0.01 M): methanol (98.7:1.3% v/v), and 20 mM di-n-butylamine at a flow rate of 1.2 ml/min. The column temperature was maintained at 32°C. The eluent was monitored at 230 nm (excitation) and 300 nm (emission) with a cut-off filter at 270 nm. This assay was used for a pharmacokinetic study in five subjects after administration of a single dose of 60 mg of terfenadine. The t½ values of the two enantiomers were similar, but the AUC values of the (+)-enantiomer were 2.05–2.35 times higher than those of (?)-enantiomer. © 1994 Wiley-Liss, Inc.  相似文献   

14.
A sensitive, selective and reproducible reversed-phase HPLC method with ultraviolet detection was developed for the quantification of diazepam in small plasma samples from children with severe malaria. The method involves plasma deproteinization with acetonitrile, followed by liquid–liquid extraction with ethyl acetate–n-hexane. Diazepam was eluted at ambient temperatures from a reversed-phase C18 column with an acidic (pH 3.5) aqueous mobile phase (10 mM KH2PO4–acetonitrile, 69:31, v/v). Calibration curves in spiked plasma were linear from 10 to 200 ng (r2≥0.99). The limit of detection was 5.0 ng/ml, and relative recoveries at 25 and 180 ng were >87%. Intra- and inter-assay relative standard deviations were <15%. There was no interference from drugs commonly administered to children with severe malaria (phenobarbitone, phenytoin, chloroquine, quinine, sulfadoxine, pyrimethamine, halofantrine, cycloguanil, chlorcycloguanil, acetaminophen and salicylate). This method has been used for monitoring plasma diazepam concentrations in children with seizures associated with severe malaria.  相似文献   

15.
A method for determining flavonoids in human plasma is presented for application to pharmacokinetic studies of two flavonoids, rhoifolin and daidzin. Isocratic reversed-phase high-performance liquid chromatography (HPLC) was used with genistin as an internal standard and solid-phase extraction using a Sep-Pak C18 cartridge. The mobile phases were acetonitrile—0.1 M ammonium acetate solution (20:80, v/v) for rhoifolin and methanol—0.1 M ammonium acetate solution (33:67, v/v) for daidzin. The detection limits on-column were 2 ng for rhoifolin and 0.5 ng for daidzin.  相似文献   

16.
A sensitive reversed-phase high-performance liquid chromatographic method for the determination of atevirdine and its primary metabolite in human saliva or cerebrospinal fluid using solid-phase extraction is described. Samples mixed with internal standard and sodium phosphate buffer were applied to an activated C18 solid-phase extraction column. The reconstituted eluate was injected onto a Zorbax RX C8 column utilizing a mobile phase of 100 mM ammonium acetate (pH 4.0)–isopropyl alcohol–acetonitrile (55:20:25, v/v/v). Fluorescence detection was employed with excitation at 295 nm and emission at 456 nm. Quantitation was achieved using peak-height ratios. The detection response curve was linear from 2 to 850 nM for atevirdine in both human saliva and cerebrospinal fluid and from 2 to 250 nM for the metabolite in human saliva. The method was utilized to analyze cerebrospinal fluid and saliva samples from clinical studies.  相似文献   

17.
An isocratic reversed-phase HPLC method was developed to determine cefepime levels in plasma and vitreous fluid. Cefepime and the internal standard cefadroxil were separated on a Shandon Hypersil BDS C18 column by using a mobile phase of 25 mM sodium dihydrogen phosphate monohydrate (pH 3) and methanol (87:13, v/v). Ultraviolet detection was carried out at 270 nm. The retention times were 4.80 min for cefepime and 7.70 min for cefadroxil. This fast procedure which involves an efficient protein precipitation step (addition of HClO4), allows a quantification limit of 2.52 μg ml−1 and a detection limit of 0.83 μg ml−1. Recoveries and absolute recoveries of cefepime from plasma were 96.13–99.44% and 94–102.5% respectively. The intra-day and inter-day reproducibilities were less than 2% for cefepime at 10, 30, 50 μg ml−1 (n=10).The method was proved to be suitable for determining cefepime levels in human plasma and was modified to measure vitreous fluid samples.  相似文献   

18.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

19.
We developed and characterized a high-performance liquid chromatography (HPLC) assay for the determination of saquinavir, an HIV protease inhibitor, in human plasma samples. Extraction of plasma samples with diethyl ether resulted in quantitative recovery of both saquinavir and its stereoisomer Ro 31-8533 which was used as an internal standard. The assay was performed isocratically using 5 mM H2SO4 (pH 3.5) and acetonitrile (75.5:24.5, v/v) containing 10 mM tetrabutylammonium hydrogen sulfate (TBA) as a mobile phase, a Nucleosil 3C8 column kept at 45°C and UV detection at 240 nm. Using this method, saquinavir and Ro 31-8533 can be separated from endogenous substances, and in the concentration range of 5–110 ng/ml the relative standard deviations for the determination of saquinavir were below 5%. The detection limit of saquinavir in human plasma was 1 ng/ml. The usefulness of the method was demonstrated by quantification of saquinavir in plasma of human subjects treated with 600 mg of saquinavir per os or 12 mg intravenously.  相似文献   

20.
We report a new HPLC procedure for measuring inulin in plasma and urine. Samples after dilution are boiled in mild acidic conditions and then analyzed on a C18 column. Solvent system A is 3.2 mM HCl, pH 2.5, and B is acetonitrile-3.2 mM HCl (60:40, v/v), pH 2.5. The separation is carried out in 8 min with a flow-rate of 1.0 ml/min and the absorbance monitored at 280 nm. The relationship between inulin and the recorded peak area is linear from 0.2 to 3.2 mg/ml with a correlation coefficient of 0.999 for plasma and 0.999 for urine. Within-run precision, measured at three inulin concentrations, ranged from 0.9 to 1.7% in plasma and from 0.8 to 1.2% in urine. Between-run precision varied in plasma from 2.7 to 3.2% and in urine from 3.0 to 3.3%. Analytical recovery ranged from 102 to 107% in plasma and from 101 to 105% in urine, respectively. The method is sensitive, selective and only 30-μl samples are required. Therefore, it could be used to evaluate the glomerular filtration rate even in small babies and to perform studies in animals.  相似文献   