首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sparse MRI has been introduced to reduce the acquisition time and raw data size by undersampling the k-space data. However, the image quality, particularly the contrast to noise ratio (CNR), decreases with the undersampling rate. In this work, we proposed an interpolated Compressed Sensing (iCS) method to further enhance the imaging speed or reduce data size without significant sacrifice of image quality and CNR for multi-slice two-dimensional sparse MR imaging in humans. This method utilizes the k-space data of the neighboring slice in the multi-slice acquisition. The missing k-space data of a highly undersampled slice are estimated by using the raw data of its neighboring slice multiplied by a weighting function generated from low resolution full k-space reference images. In-vivo MR imaging in human feet has been used to investigate the feasibility and the performance of the proposed iCS method. The results show that by using the proposed iCS reconstruction method, the average image error can be reduced and the average CNR can be improved, compared with the conventional sparse MRI reconstruction at the same undersampling rate.  相似文献   

2.
Blood oxygen level-dependent (BOLD) MRI is a non-invasive diagnostic method for assessing tissue oxygenation level, by changes in the transverse relaxation time T2*. 3D BOLD imaging of lung tumours is challenging, because respiratory motion can lead to significant image quality degradation. The purpose of this work was to explore the feasibility of a three dimensional (3D) Cartesian multi gradient echo (MGRE) sequence for T2* measurements of non-small cell lung tumours during free-breathing. A non-uniform quasi-random reordering of the pahse encoding lines that allocates more sampling points near the k-space origin resulting in efficient undersampling pattern for parallel imaging was combined with multi echo acquisition and self-gating. In a series of three patients 3D T2* maps of lung carcinomas were generated with isotropic spatial resolution and full tumour coverage at air inhalation and after hyperoxic gas challenge in arbitrary respiratory phases using the proposed self-gated MGRE acquisition. The changes in T2* on the inhalation of hyperoxic gas relative to air were quantified. Significant changes in T2* were observed following oxygen inhalation in the tumour (p < 0.02). Thus, the self-gated MGRE sequence can be used for assessment of BOLD signal with isotropic resolution and arbitrary respiratory phases in non-small cell lung cancer.  相似文献   

3.
Coronary magnetic resonance imaging (MRI) requires a correctly timed trigger delay derived from a scout cine scan to synchronize k-space acquisition with the quiescent period of the cardiac cycle. However, heart rate changes between breath-held cine and free-breathing coronary imaging may result in inaccurate timing errors. Additionally, the determined trigger delay may not reflect the period of minimal motion for both left and right coronary arteries or different segments. In this work, we present a whole-heart coronary imaging approach that allows flexible selection of the trigger delay timings by performing k-space sampling over an enlarged acquisition window. Our approach addresses coronary motion in an interactive manner by allowing the operator to determine the temporal window with minimal cardiac motion for each artery region. An electrocardiogram-gated, k-space segmented 3D radial stack-of-stars sequence that employs a custom rotation angle is developed. An interactive reconstruction and visualization platform is then employed to determine the subset of the enlarged acquisition window for minimal coronary motion. Coronary MRI was acquired on eight healthy subjects (5 male, mean age = 37 ± 18 years), where an enlarged acquisition window of 166–220 ms was set 50 ms prior to the scout-derived trigger delay. Coronary visualization and sharpness scores were compared between the standard 120 ms window set at the trigger delay, and those reconstructed using a manually adjusted window. The proposed method using manual adjustment was able to recover delineation of five mid and distal right coronary artery regions that were otherwise not visible from the standard window, and the sharpness scores improved in all coronary regions using the proposed method. This paper demonstrates the feasibility of a whole-heart coronary imaging approach that allows interactive selection of any subset of the enlarged acquisition window for a tailored reconstruction for each branch region.  相似文献   

4.
Single band coherent anti‐Stokes Raman scattering (CARS) microscopy is one of the fastest implementation of nonlinear vibrational imaging allowing for video‐rate image acquisition of tissue. This is due to the large Raman signal in the C—H‐stretching region. However, the chemical specificity of such images is conventionally assumed to be low. Nonetheless, CARS imaging within the C—H‐stretching region enables detection of single cells and nuclei, which allows for histopathologic grading of tissue. Relevant information such as nucleus to cytoplasm ratio, cell density, nucleus size and shape is extracted from CARS images by innovative image processing procedures. In this contribution CARS image contrast within the C—H‐stretching region is interpreted by direct comparison with Raman imaging and correlated to the tissue composition justifying the use of CARS imaging in this wavenumber region for biomedical applications. (© 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

5.
This report presents a quantitative evaluation of the effect of the keyhole technique on contrast-enhanced dynamic MRI; specifically, the effect of the observed region of interest (ROI) on keyhole images was evaluated in comparison with a complete set of data. The limiting condition of the quantitative use of the keyhole approach was defined and exemplified. Results obtained by simulations, as well as on MR images, indicated that object size and noise level determine the minimum keyhole size and maximum size of the ROI, so that if keyhole parameters are properly selected, a quantitative analysis of MRI gives the same signal intensity as complete data acquisition. In this case the time resolution increases by factor N/L.  相似文献   

6.
PurposeEdge illumination (EI) X-ray phase-contrast imaging (XPCI) has been under development at University College London in recent years, and has shown great potential for both laboratory and synchrotron applications. In this work, we propose a new acquisition and processing scheme. Contrary to existing retrieval methods for EI, which require as input two images acquired in different setup configurations, the proposed approach can retrieve an approximate map of the X-ray phase from a single image, thus significantly simplifying the acquisition procedure and reducing data collection times.MethodsThe retrieval method is analytically derived, based on the assumption of a quasi-homogeneous object, i.e. an object featuring a constant ratio between refractive index and absorption coefficient. The noise properties of the input and retrieved images are also theoretically analyzed under the developed formalism. The method is applied to experimental synchrotron images of a biological object.ResultsThe experimental results show that the method can provide high-quality images, where the “edge” signal typical of XPCI images is transformed to an “area” contrast that enables an easier interpretation of the sample geometry. Moreover, the retrieved images confirm that the method is highly stable against noise.ConclusionsWe anticipate that the developed approach will become the method of choice for a variety of applications of EI XPCI, thanks to its ability to simplify the acquisition procedure and reduce acquisitions time and dose to the sample. Future work will focus on the adaptation of the method to computed tomography and to polychromatic radiation from X-ray tubes.  相似文献   

7.
Although magnetic resonance imaging (MRI) is a useful technique, only a few studies have investigated the dynamic behavior of small subjects using MRI owing to constraints such as experimental space and signal amount. In this study, to acquire high-resolution continuous three-dimensional gravitropism data of pea (Pisum sativum) sprouts, we developed a small-bore MRI signal receiver coil that can be used in a clinical MRI and adjusted the imaging sequence. It was expected that such an arrangement would improve signal sensitivity and improve the signal-to-noise ratio (SNR) of the acquired image. All MRI experiments were performed using a 3.0-T clinical MRI scanner. An SNR comparison using an agarose gel phantom to confirm the improved performance of the small-bore receiver coil and an imaging experiment of pea sprouts exhibiting gravitropism were performed. The SNRs of the images acquired with a standard 32-channel head coil and the new small-bore receiver coil were 5.23±0.90 and 57.75±12.53, respectively. The SNR of the images recorded using the new coil was approximately 11-fold higher than that of the standard coil. In addition, when the accuracy of MR imaging that captures the movement of pea sprout was verified, the difference in position information from the optical image was found to be small and could be used for measurements. These results of this study enable the application of a clinical MRI system for dynamic plant MRI. We believe that this study is a significant first step in the development of plant MRI technique.  相似文献   

8.
TIRF microscopy has emerged as a powerful imaging technology to study spatio-temporal dynamics of fluorescent molecules in vitro and in living cells. The optical phenomenon of total internal reflection occurs when light passes from a medium with high refractive index into a medium with low refractive index at an angle larger than a characteristic critical angle (i.e. closer to being parallel with the boundary). Although all light is reflected back under such conditions, an evanescent wave is created that propagates across and along the boundary, which decays exponentially with distance, and only penetrates sample areas that are 100-200 nm near the interface. In addition to providing superior axial resolution, the reduced excitation of out of focus fluorophores creates a very high signal to noise ratios and minimizes damaging effects of photobleaching. Being a widefield technique, TIRF also allows faster image acquisition than most scanning based confocal setups. At first glance, the low penetration depth of TIRF seems to be incompatible with imaging of bacterial and fungal cells, which are often surrounded by thick cell walls. On the contrary, we have found that the cell walls of yeast and bacterial cells actually improve the usability of TIRF and increase the range of observable structures. Many cellular processes can therefore be directly accessed by TIRF in small, single-cell microorganisms, which often offer powerful genetic manipulation techniques. This allows us to perform in vivo biochemistry experiments, where kinetics of protein interactions and activities can be directly assessed in living cells. We describe here the individual steps required to obtain high quality TIRF images for Saccharomyces cerevisiae or Bacillus subtilis cells. We point out various problems that can affect TIRF visualization of fluorescent probes in cells and illustrate the procedure with several application examples. Finally, we demonstrate how TIRF images can be further improved using established image restoration techniques.  相似文献   

9.
MRI-guided microwave ablation (MWA) is a minimally invasive treatment for localized cancer. MR thermometry has been shown to be able to provide vital information for monitoring the procedure in real-time. However, MRI during active MWA can suffer from image quality degradation due to intermittent electromagnetic interference (EMI). A novel approach to correct for EMI-contaminated images is presented here to improve MR thermometry during clinical hepatic MWA. The method was applied to MR-thermometry images acquired during four MR-guided hepatic MWA treatments using a commercially available MRI-configured microwave generator system. During the treatments MR thermometry data acquisition was synchronized to respiratory cycle to minimize the impact of motion. EMI was detected and corrected using uncontaminated k-space data from nearby frames in k-space. Substantially improved temperature and thermal damage maps have been obtained and the treatment zone can be better visualized. Our ex vivo tissue sample study shows the correction introduced minimal errors to the temperature maps and thermal damage maps.  相似文献   

10.
As data acquisition for retinal imaging with optical coherence tomography (OCT) becomes faster, efficient collection of photons becomes more important to maintain image quality. One approach is to use a larger aperture at the eye's pupil to collect more photons that have been reflected from the retina. A 2.8‐mm beam diameter system with only seven reflecting surfaces was developed for low‐loss retinal imaging. The larger beam size requires defocus and astigmatism correction, which was done in a closed loop adaptive optics method using a Shack‐Hartmann wavefront sensor and a deformable mirror (DM) with 140 actuators and a ±2.75 μm stroke. This DM facilitates defocus correction ranging from approximately ?3 D to +3 D. Comparing the new system with a standard 1.2‐mm system on a model eye, a signal‐to‐noise gain of 4.5 dB and a 2.3 times smaller speckle size were measured. Measurements on the retinas of five subjects showed even better results, with increases in dynamic range up to 13 dB. Note that the new sample arm only occupies 30 cm × 60 cm, which makes it highly suitable for imaging in a clinical environment. Figure: B‐scan images obtained over a width of 8 deg from the right eye of a 31‐year‐old Caucasian male. While the left side was imaged with a standard 1.2‐mm OCT system, the right side was imaged with the 2.8‐mm system. Both images were collected with the same integration time and incident power, after correction of aberrations. Using the dynamic range within the images, which is determined by comparing the highest pixel value to the noise floor, a difference in dynamic range of 10.8 dB was measured between the two systems.   相似文献   

11.
本文提出了一种基于空间频率滤波的多曝光融合的高动态投影层析三维成像方法,实现了活体斑马鱼(17 mm × 4 mm,最大厚度为2.33 mm,最小厚度为0.29 mm)的三维结构成像. 通过相机采用不同曝光时间记录系列吸收图像,将每张图像取变换到频域去除低频后,将各张滤波后叠加并逆傅里叶变换回空域,对变换后的图像进行归一化处理,最终获得高动态图像. 在每个投影角度获得这种高动态吸收投影图像,进行滤波反投影算法重建,获得高动态的整条斑马鱼三维结构信息. 实验成像结果表明,这种空间频率滤波多曝光融合的高动态光学投影层析三维成像研究,可以获得复杂结构更丰富的空间信息,对斑马鱼等模式生物早期胚胎生长发育进程进行监测和定量评估有一定的应用前景.  相似文献   

12.
A single-shot adaptation of Optical Projection Tomography (OPT) for high-speed volumetric snapshot imaging of dynamic mesoscopic biological samples is presented. Conventional OPT has been applied to in vivo imaging of animal models such as D. rerio, but the sequential acquisition of projection images typically requires samples to be immobilized during the acquisition. A proof-of-principle system capable of single-shot tomography of a ~1 mm3 volume is presented, demonstrating camera-limited rates of up to 62.5 volumes/s, which has been applied to 3D imaging of a freely swimming zebrafish embryo. This is achieved by recording eight projection views simultaneously on four low-cost CMOS cameras. With no stage required to rotate the sample, this single-shot OPT system can be implemented with a component cost of under £5000. The system design can be adapted to different sized fields of view and may be applied to a broad range of dynamic samples, including high throughput flow cytometry applied to model organisms and fluid dynamics studies.  相似文献   

13.
目的 声聚焦光声内窥成像具有成像深度大的优点,是一种非常有前景的功能成像技术,该技术被广泛应用于直肠、食道等内窥成像中。声聚焦光声内窥成像通常采用基于单个聚焦超声传感器的侧向扫描方式,同时采用传统的B扫描方法进行重建,会大大降低图像质量。为了获得高质量的图像,本文提出了几种动态聚焦的声聚焦光声内窥成像算法。方法 本文使用几种动态聚焦算法进行了数值仿真,并搭建系统进行了仿体实验验证,从横向分辨率和信噪比等多方面比较了各算法在动态聚焦中的成像效果。结果 相比B扫描方法,动态聚焦后的图像在离焦区域的横向分辨率与信噪比方面都有提升,仿真模拟中最高可将离焦区域的成像目标分辨率提升约26倍,其信噪比经动态聚焦后最高可提高2.3倍左右,实验中的远距离点目标经动态聚焦重建后分辨率提升3~6倍。结论 整体而言,基于时空响应的算法和合成孔径聚焦重建算法是在实验条件下更为适用的算法。本工作对后续的声聚焦光声内窥成像的设计具有指导意义。  相似文献   

14.
Physical contacts between organelles play a pivotal role in intracellular trafficking of metabolites. Monitoring organelle interactions in living cells using fluorescence microscopy is a powerful approach to functionally assess these cellular processes. However, detailed target acquisition is typically limited due to light diffraction. Furthermore, subcellular compartments such as lipid droplets and mitochondria are highly dynamic and show significant subcellular movement. Thus, high-speed acquisition of these organelles with extended-resolution is appreciated. Here, we present an imaging informatics pipeline enabling spatial and time-resolved analysis of the dynamics and interactions of fluorescently labeled lipid droplets and mitochondria in a fibroblast cell line. The imaging concept is based on multispectral confocal laser scanning microscopy and includes high-speed resonant scanning for fast spatial acquisition of organelles. Extended-resolution is achieved by the recording of images at minimized pinhole size and by post-processing of generated data using a computational image restoration method. Computation of inter-organelle contacts is performed on basis of segmented spatial image data. We show limitations of the image restoration and segmentation part of the imaging informatics pipeline. Since both image processing methods are implemented in other related methodologies, our findings will help to identify artifacts and the false-interpretation of obtained morphometric data. As a proof-of-principle, we studied how lipid load and overexpression of PLIN5, considered to be involved in the tethering of LDs and mitochondria, affects organelle association.  相似文献   

15.
Non‐invasive biological imaging is crucial for understanding in vivo structure and function. Optical coherence tomography (OCT) and reflectance confocal microscopy are two of the most widely used optical modalities for exogenous contrast‐free, high‐resolution, three‐dimensional imaging in non‐fluorescent scattering tissues. However, sample motion remains a critical barrier to raster‐scanned acquisition and reconstruction of wide‐field anatomically accurate volumetric datasets. We introduce spectrally encoded coherence tomography and reflectometry (SECTR), a high‐speed, multimodality system for simultaneous OCT and spectrally encoded reflectance (SER) imaging. SECTR utilizes a robust system design consisting of shared optical relays, scanning mirrors, swept laser and digitizer to achieve the fastest reported in vivo multimodal imaging rate of 2 gigapixels per second. Our optical design and acquisition scheme enable spatiotemporally co‐registered acquisition of OCT cross‐sections simultaneously with en face SER images for multivolumetric mosaicking. Complementary axial and lateral translation and rotation are extracted from OCT and SER data, respectively, for full volumetric estimation of sample motion with micron spatial and millisecond temporal resolution.   相似文献   

16.
Capturing dynamic processes in live samples is a nontrivial task in biological imaging. Although fluorescence provides high specificity and contrast compared to other light microscopy techniques, the photophysical principles of this method can have a harmful effect on the sample. Current advances in light sheet microscopy have created a novel imaging toolbox that allows for rapid acquisition of high-resolution fluorescent images with minimal perturbation of the processes of interest. Each unique design has its own advantages and limitations. In this review, we describe several cutting edge light sheet microscopes and their optimal applications.  相似文献   

17.
Slot blot hybridization of membrane-immobilized, single-stranded human DNA with the higher primate-specific alphoid probe D17Z1 is routinely used in forensic science to estimate the amount of DNA in biological samples. Typically, a chemiluminescent signal captured on film records the hybridization, and the quantity of the signal is related to the amount of immobilized DNA. Digital imaging using a cooled CCD camera offers an alternate non-film-based method for image acquisition with comparable sensitivity of detection, a greater dynamic range, enhanced capability of data interpretation, and often faster results than film. In addition, the data support the premise that more accurate and precise human DNA quantification should be obtained by not assuming a linear response of signal to known standards. Instead, quantity should be estimated using a second-order standard curve (R2 = 0.999). Finally, a CCD camera imaging system offers versatility for image capture of different signal sources and analysis of samples on a variety of support media.  相似文献   

18.
Visible and subvisible particles are a quality attribute in sterile pharmaceutical samples. A common method for characterizing and quantifying pharmaceutical samples containing particulates is imaging many individual particles using high-throughput instrumentation and analyzing the populations data. The analysis includes conventional metrics such as the particle size distribution but can be more sophisticated by interpreting other visual/morphological features. To avoid the hurdles of building new image analysis models capable of extracting such relevant features from scratch, we propose using well-established pretrained deep learning image analysis models such as EfficientNet. We demonstrate that such models are useful as a prescreening tool for high-level characterization of biopharmaceutical particle image data. We show that although these models are originally trained for completely different tasks (such as the classification of daily objects in the ImageNet database), the visual feature vectors extracted by such models can be useful for studying different types of subvisible particles. This applicability is illustrated through multiple case studies: (i) particle risk assessment in prefilled syringe formulations containing different particle types such as silicone oil, (ii) method comparability with the example of accelerated forced degradation, and (iii) excipient influence on particle morphology with the example of Polysorbate 80 (PS80). As examples of agnostic applicability of pretrained models, we also elucidate the application to two high-throughput microscopy methods: microflow and background membrane imaging. We show that different particle populations with different morphological and visual features can be identified in different samples by leveraging out-of-the-box pretrained models to analyze images from each sample.  相似文献   

19.
Acquiring information of the neural structures in the whole‐brain level is vital for systematically exploring mechanisms and principles of brain function and dysfunction. Most methods for whole brain imaging, while capable of capturing the complete morphology of neurons, usually involve complex sample preparation and several days of image acquisition. The whole process including optical clearing or resin embedding is time consuming for a quick survey of the distribution of specific neural circuits in the whole brain. Here, we develop a high‐throughput light‐sheet tomography platform (HLTP), which requires minimum sample preparation. This method does not require optical clearing for block face light sheet imaging. After fixation using paraformaldehyde, an aligned 3 dimensional image dataset of a whole mouse brain can be obtained within 5 hours at a voxel size of 1.30 × 1.30 × 0.92 μm. HLTP could be a very efficient tool for quick exploration and visualization of brain‐wide distribution of specific neurons or neural circuits.   相似文献   

20.
Full-field OCT     
Optical coherence tomography (OCT) is an emerging technique for imaging of biological media with micrometer-scale resolution, whose most significant impact concerns ophthalmology. Since its introduction in the early 1990's, OCT has known a lot of improvements and sophistications. Full-field OCT is our original approach of OCT, based on white-light interference microscopy. Tomographic images are obtained by combination of interferometric images recorded in parallel by a detector array such as a CCD camera. Whereas conventional OCT produces B-mode (axially-oriented) images like ultrasound imaging, full-field OCT acquires tomographic images in the en face (transverse) orientation. Full-field OCT is an alternative method to conventional OCT to provide ultrahigh resolution images (approximately 1 microm), using a simple halogen lamp instead of a complex laser-based source. Various studies have been carried, demonstrating the performances of this technology for three-dimensional imaging of ex vivo specimens. Full-field OCT can be used for non-invasive histological studies without sample preparation. In vivo imaging is still difficult because of the object motions. A lot of efforts are currently devoted to overcome this limitation. Ultra-fast full-field OCT was recently demonstrated with unprecedented image acquisition speed, but the detection sensitivity has still to be improved. Other research directions include the increase of the imaging penetration depth in highly scattering biological tissues such as skin, and the exploitation of new contrasts such as optical birefringence to provide additional information on the tissue morphology and composition.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号