首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, sensitive and selective HPLC method with UV detection (315 nm) was developed and validated for quantitation of entacapone in human plasma, the newest addition to the group of antiparkinsonian agents. Following a single-step liquid-liquid extraction (LLE) with ethyl acetate/n-hexane (30/70, v/v), the analyte and internal standard (rofecoxib) were separated using an isocratic mobile phase of 30 mM phosphate buffer (pH 2.75)/acetonitrile (62/38, v/v) on a reverse phase C18 column. The lower limit of quantitation was 25 ng/mL, with a relative standard deviation of less than 8%. A linear range of 25-2500 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 2.2-4.2% and 1.7-7.8%, respectively. The between-batch and within-batch accuracy was 98.7-107.5% and 97.5-106.0%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of entacapone in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

2.
A simple, sensitive and selective HPLC method with UV detection (284 nm) was developed and validated for quantitation of rabeprazole in human plasma, the newest addition to the group of proton-pump inhibitors. Following solid-phase extraction using Waters Oasistrade mark SPE cartridges, the analyte and internal standard (Pantoprazole) were separated using an isocratic mobile phase of 5 mM ammonium acetate buffer (pH adjusted to 7.4 with sodium hydroxide solution)/acetonitrile/methanol (45/20/35, v/v) on reverse phase Waters symmetry C(18) column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 8%. A linear range of 20-1000 ng/mL was established. This HPLC method was validated with between- and within-batch precision of 2.4-7.2% and 2.2-7.3%, respectively. The between- and within-batch bias was -1.7 to 2.6% and -2.6 to 2.1%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of rabeprazole in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 3 months storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

3.
A rapid HPLC method was developed for quantification of unbound evernimicin in human plasma. Protein-free samples prepared by ultrafiltration were injected directly onto a polymeric reversed-phase column and the eluent monitored at 302 nm. Evernimicin that eluted within 3.5 min was well resolved from endogenous components. Linearity was established between peak height and evernimicin concentration from 25 to 2500 ng/ml. Assay precision (C.V.) was within 5% while bias was no greater than 3%. This method has been used for the ex vivo assessment of evernimicin protein binding in human plasma from safety and tolerance as well as liver dysfunction and renal insufficiency studies.  相似文献   

4.
5.
Multidimensional HPLC is a powerful tool for the analysis of samples of a high degree of complexity. This work reports the use of multidimensional HPLC by coupling a RAM column with a chiral polysaccharide column to the analysis of Pantoprazole in human plasma by direct injection. The enantiomers from the plasma samples were separated with high resolution on a tris(3,5-dimethoxyphenylcarbamate) of amylose phase after clean-up by a RAM BSA octyl column. Water was used as solvent for the first 5 min in a flow-rate of 1.0 ml/min for the elution of the plasmatic proteins and then acetonitrile-water (35:65 v/v) for the transfer and analysis of pantoprazole enantiomers, which were detected by UV at 285 nm. Analysis time was 28 min with no time spent on sample preparation. A good linear relationship was obtained in the concentration range of 0.20 to 1.5 microg/ml for each enantiomer. Inter and intra-day precision and accuracy were determined by one low (0.24 microg/ml), one medium (0.70 microg/ml) and one high (1.3 microg/ml) plasma concentration and gave a C.V. varying from 1.80 to 8.43% and accuracy from 86 to 92%. Recoveries of pantoprazole enantiomers were in the range of 93.7-101.2%. The validated method was applied to the analysis of the plasma samples obtained from ten Brazilian volunteers who received an 80 mg oral dose of racemic pantoprazole and was able to quantify the enantiomers of pantoprazole in all clinical samples analyzed.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of busulfan in plasma. Busulfan was extracted in toluene, derivatized by 2,3,5,6-tetrafluorothiophenol to obtain di-TFTP-butane, the derivatization product was then re-extracted in toluene and injected into the HPLC system with ultraviolet detection (wavelength: 275 nm). Recovery from extraction was 80%, the limit of quantification was 50 ng/ml and linearity ranged from 50 to 2000 ng/ml. In addition, forty-two samples obtained from pediatric patients treated with busulfan were analyzed by the HPLC and GC–MS assays based on the same derivatization procedure. The correlation between the di-TFTP-butane concentrations was highly significant (p<0.0001), demonstrating that the two methods were in good agreement.  相似文献   

7.
A sensitive high-performance liquid chromatography (HPLC) method using UV detection for the determination of gabapentin in human plasma has been developed. In this method, gabapentin was extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge followed by derivatization with phenylisothiocyanate. Analysis was achieved by using a HPLC system that was equipped with a UV detector. The quantitation limit of gabapentin in human plasma was 0.03 microg/ml. The method is sensitive with excellent selectivity and reproducibility and it has been applied to a bioequivalence clinical study with great success.  相似文献   

8.
Gangliosides are a family of glycosphingolipids characterized by mono- or polysialic acid-containing oligosaccharides linked through 1,3- and 1,4-β glycosidic bonds with subtle differences in structure that are abundantly present in the central nervous systems of many living organisms. Their cellular surface expression and physiological malfunction are believed to be pathologically implicated in considerable neurological disorders, including Alzheimer and Parkinson diseases. Recently, studies have tentatively elucidated that mental retardation or physical stagnation deteriorates as the physiological profile of gangliosides becomes progressively and distinctively abnormal during the development of these typical neurodegenerative syndromes. In this work, a reverse-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay using standard addition calibration for determination of GM2, GM3, GD2, and GD3 in human plasma has been developed and validated. The analytes and internal standard were extracted from human plasma using a simple protein precipitation procedure. Then the samples were analyzed by reverse-phase ultra-performance liquid chromatography (UPLC)/MS/MS interfaced to mass spectrometry with electrospray ionization using a multiple reaction monitoring mode to obtain superior sensitivity and specificity. This assay was validated for extraction recovery, calibration linearity, precision, and accuracy. Our quick and sensitive method can be applied to monitor ganglioside levels in plasma from normal people and neurodegenerative patients.  相似文献   

9.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

10.
A rapid and specific liquid chromatographic mass spectrometric (LC-MS-MS) method has been developed for the determination of paroxetine in human plasma. The procedure involves a liquid-liquid extraction of paroxetine and fluoxetine (internal standard) with cyclohexane-ethyl acetate. The standard curve was linear over a working range of 0.2-50 ng/ml. The lower limit of quantitation was 0.2 ng/ml. No endogenous compounds were found to interfere with the analysis. The absolute recovery was 70.8% for paroxetine and 84.1% for the internal standard. The accuracy of inter-assay and intra-assay accuracy was in the ranges -4.8 to -0.5% and -3.4 to 4.8%, respectively. This method proved to be suitable for bioequivalence studies by being simple, selective and reproducible.  相似文献   

11.
An isocratic high-performance liquid chromatography method has been developed for the quantification of the skin sensitisers trans-cinnamaldehyde and trans-cinnamic alcohol, and their cinnamic metabolites. The relative standard deviations (RSDs) between the gradients of eight sets of standard curves were 2.8, 3.1 and 1.9% for cinnamic alcohol, cinnamaldehyde and cinnamic acid, respectively. Sample analytes were derived from two series of experiments: in vitro full-thickness human skin absorption and metabolism studies and metabolism studies using human skin homogenates, with non-radiolabelled cinnamic compounds. Skin absorption and metabolism experiments were performed in the absence and presence of the alcohol dehydrogenase inhibitor, pyrazole. Samples from full-thickness skin absorption studies were analysed without extraction; cinnamic compounds from within skin were extracted into methanolic solutions using newly developed methods. The intra-assay RSDs ranged from 0.17 to 2.52% for cinnamic alcohol, 0.24 to 9.14% for cinnamaldehyde and 0.26 to 6.43% for cinnamic acid. The inter-assay RSDs for cinnamic alcohol, cinnamaldehyde and cinnamic acid, respectively, as determined from n=20 HPLC runs, were 2.10, 4.16 and 2.26%.  相似文献   

12.
This paper describes a simple, fast and sensitive liquid chromatography-mass spectrometry method for quantification of an anti-thrombocythemic agent, anagrelide in human plasma. The samples were subjected to a liquid-liquid extraction after addition of a buffer and an internal standard. Chromatography was performed on an Inertsil ODS2 column and the extract was injected onto a HPLC system coupled with mass spectrometric detection. Linear responses for standards were observed from 50 to 7500 pg/ml. The accuracy of intra-assay and inter-assay were in the ranges 4.3-4.4% and 4.8-5.6%, respectively. The method is simple and reproducible with a run time of less than 2 min.  相似文献   

13.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. After a simple protein precipitation using acetonitrile, the analytes were separated on a Zorbax SB-Aq C18 column using acetonitrile-10mM ammonium acetate (60:40, v/v, pH 4.5) as mobile phase at a flow rate of 1.2 mL/min. Valsartan and hydrochlorothiazide were eluted at 2.08 min and 1.50 min, respectively, ionized using ESI source, and then detected by multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 434.2-350.2 and m/z 295.9-268.9 were used to quantify valsartan and hydrochlorothiazide, respectively. The method was linear in the concentration range of 4-3600 ng/mL for valsartan and 1-900 ng/mL for hydrochlorothiazide. The method was successfully employed in a pharmacokinetic study after an oral administration of a dispersible tablet containing 80 mg valsartan and 12.5 mg hydrochlorothiazide to each of the 20 healthy volunteers.  相似文献   

14.
A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MS-MS) has been developed to quantitate clemastine in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using deuterated clemastine as an internal standard. Chromatographic separation used a C18 reversed phase polymer column giving an extremely fast total run time of 2 min. The method was validated and used for the bioequivalence study of clemastine tablets in healthy male volunteers (n=28). The lower limit of detection proved to be 0.01 ng/ml for clemastine.  相似文献   

15.
A simple high-performance liquid chromatographic (HPLC) method for the determination of flufenamic acid in rat plasma is described. After liquid-liquid extraction, the drug is separated by HPLC on a 5-μm octadecylsilica column (Nucleosil C18) with ultraviolet detection at 280 nm. Linear calibration graphs for flufenamic acid were constructed from 0.5 to 15 μg/ml. The method has been applied to a pharmacokinetic study in animals.  相似文献   

16.
A rapid, reproducible and accurate high-performance liquid chromatographic (HPLC) method for the quantitative determination of sphingomyelin in rat brain was developed and validated using normal-phase silica gel column, acetonitrile-methanol-water (65:18:17 (v/v)) at a flow rate of 1 ml/min, isocratic elution, UV detection at 207 nm and 1,2-dimyristoyl-sn-glycero-3-phosphocholine as an internal standard. Total run time was 10.0 min. The calibration curve was linear over the range of 0.025-0.4 mg/ml sphingomyelin (R2>0.99). The intra-day coefficient of variation ranged from 1.4% to 2.2%. The average inter-day coefficient of variation over a period of 4 days was 3.1%. The practical limit of detection was 0.005 mg/ml with a quantification limit of 0.01 mg/ml.  相似文献   

17.
18.
A robust, fully automated assay procedure for the determination of rosiglitazone (I, BRL-49653) in human plasma has been developed. Plasma concentrations of I were determined using automated sequential trace enrichment of dialysates (ASTED) coupled to reversed-phase high-performance liquid chromatography. Sequential automated dialysis of human plasma samples was followed by concentration of the dialysate by trace enrichment on a C18 cartridge. Drug and internal standard, SB-204882 (II) were eluted from the trace enrichment cartridge by mobile phase (0.01 M ammonium acetate, pH 8–acetonitrile, 65:35, v/v) onto the HPLC column (a Novapak C18, 4 μm, 100×5 mm radial compression cartridge) protected by a Guard-Pak C18 cartridge. The compounds were detected by fluorescence detection, using an excitation wavelength of 247 nm, and emission wavelength of 367 nm. The lower limit of quantitation of the method was 3 ng/ml (200 μl aliquot) with linearity demonstrated up to 100 ng/ml. Within- and between-run precision and accuracy of determination were better than 10% across the calibration range. There was no evidence of instability of I in human plasma following three complete freeze–thaw cycles and samples can be safely stored for at least 7 months at −20°C. This method has been successfully utilised to provide pharmacokinetic data throughout the clinical development of rosiglitazone.  相似文献   

19.
A method is described that allows the rapid and precise determination of the local anaesthetics bupivacaine and etidocaine from biological fluids. This method uses a fully automated system with solid-phase extraction in combination with a column-switching technique. Both sample extraction on a LiChrocart pre-column and elution onto the analytical LiChrospher column, were performed automatically and concomitantly using conventional HPLC equipment in conjunction with an OSP-2 on-line sample preparator from Merck combined with UV detection. Recoveries were found to be 96.7 and 96.4% for 2 μg/ml bupivacaine and etidocaine, respectively. Lower limits of quantification were found to be 0.05 μg/ml plasma for both of the compounds.  相似文献   

20.
Problems inherent in corticosterone radioimmunoassay (RIA) led to consideration of alternative methods. A high-performance liquid chromatography (HPLC) procedure was evaluated that separated and quantitated dichloromethane-extracted corticosterone by reverse-phase chromatography. The results were correlated (r = 0.92) with an RIA procedure. The HPLC recovered nearly 100% of corticosterone added to rat plasma and had excellent reproducibility. In addition, chromatogram profiles of dichloromethane-soluble components obtained from rat plasma, derived from drug effect studies, could have value for characterizing response patterns. Without automated sample injection equipment, HPLC is more appropriately applied in monitoring RIA results than in processing large numbers of samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号