1.
Objective: The objective of this study was to fabricate a successful implant for temporomandibular joint (TMJ) disorder patients who could not be treated through conventional surgeries.

Methods: A custom-made implant was fabricated using rapid prototyping (RP) for the TMJ surgery. The stability of the metallic implant was validated using a finite element analysis.

Results: The results of finite elements were stable and the design of the TMJ implant was suitable as per the patient's need. The customised implant was made using a fused deposition modelling method of RP and a vertical machining centre. The implant has provided normal jaw function for over 2 years since surgery.

Conclusions: The approach utilised will be helpful in providing successful treatment to the deformed mandible and the mandible joints. This method allows to customise and to accurately fabricatie the implant. Advantages of this approach are that the physical model of the implant was tested for stability before the implantation, the surgeon can plan and rehearse the surgery in advance, it is a less invasive and less time-consuming surgical procedure.  相似文献   

2.
3.
This study was mainly performed to investigate the effects of high maxillary expansion forces on the skull with fresh and thiel-fixed human skulls. The maxillary suture was not weakened except in one experiment. This study compares the strain measured on the zygomatic process of the skull with the results of a finite element model generated for this purpose. An increasing transversal force was applied on the alveolar process (teeth) until rupture. Strain on the zygomatic process, maxilla displacement and the expanding forces were registered.The results of this study show linear material behaviour of the skull before rupture. The highest stress during the experiments and FE simulation was observed on the alveolar process.Conclusions of this study are the necessity of the existence of appropriate models and that female specimens seem to rupture at a lower force than male ones. Both male and female specimens show a similar linear behaviour in the force/strain curve within each gender group. The probability of maxillary suture opening in adults during ultra-rapid maxillary expansion with tooth anchorage is very low. Complications and unwanted rupture could occur.  相似文献   

4.
A validation study was conducted to determine the extent to which computational ankle contact finite element (FE) results agreed with experimentally measured tibio-talar contact stress. Two cadaver ankles were loaded in separate test sessions, during which ankle contact stresses were measured with a high-resolution (Tekscan) pressure sensor. Corresponding contact FE analyses were subsequently performed for comparison. The agreement was good between FE-computed and experimentally measured mean (3.2% discrepancy for one ankle, 19.3% for the other) and maximum (1.5% and 6.2%) contact stress, as well as for contact area (1.7% and 14.9%). There was also excellent agreement between histograms of fractional areas of cartilage experiencing specific ranges of contact stress. Finally, point-by-point comparisons between the computed and measured contact stress distributions over the articular surface showed substantial agreement, with correlation coefficients of 90% for one ankle and 86% for the other. In the past, general qualitative, but little direct quantitative agreement has been demonstrated with articular joint contact FE models. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces (e.g., those from an intact versus those with residual intra-articular fracture incongruity).  相似文献   

5.
Abstract

Orthodontic tooth movement is mainly regulated by the biomechanical responses of loaded periodontal ligament (PDL). We investigated the effective intervals of orthodontic force in pure maxillary canine intrusion and extrusion referring to PDL hydrostatic stress and logarithmic strain. Finite element analysis (FEA) models, including a maxillary canine, PDL and alveolar bone, were constructed based on computed tomography (CT) images of a patient. The material properties of alveolar bone were non-uniformly defined using HU values of CT images; PDL was assumed to be a hyperelastic–viscoelastic material. The compressive stress and tensile stress ranging from 0.47 to 12.8?kPa and 18.8 to 51.2?kPa, respectively, were identified as effective for tooth movement; a strain 0.24% was identified as the lower limit of effective strain. The stress/strain distributions within PDL were acquired in canine intrusion and extrusion using FEA; root apex was the main force-bearing area in intrusion–extrusion movements and was more prone to resorption. Owing to the distinction of PDL biomechanical responses to compression and tension, the effective interval of orthodontic force was substantially lower in canine intrusion (80–90?g) than in canine extrusion (230–260?g). A larger magnitude of force remained applicable in canine extrusion. This study revised and complemented orthodontic biomechanical behaviours of tooth movement with intrusive–extrusive force and could further help optimize orthodontic treatment.  相似文献   

6.
7.
Magnetic resonance (MR) imaging has been widely used to evaluate the thickness and volume of articular cartilage both in vivo and in vitro. While morphological information on the cartilage can be obtained using MR images, image processing for extracting geometric boundaries of the cartilage may introduce variations in the thickness of the cartilage. To evaluate the variability of using MR images to construct finite element (FE) knee cartilage models, five investigators independently digitized the same set of MR images of a human knee. The topology of cartilage thickness was determined using a minimal distance algorithm. Less than 8 percent variation in cartilage thickness was observed from the digitized data. The effect of changes in cartilage thickness on contact stress analysis was then investigated using five FE models of the knee. One FE model (average FE model) was constructed using the mean values of the digitized contours of the cartilage, and the other four were constructed by varying the thickness of the average FE model by +/- 5 percent and +/- 10 percent, respectively. The results demonstrated that under axial tibial compressive loading (up to 1,400 N), variations of cartilage thickness caused by digitization of MR images may result in a difference of approximately 10 percent in peak contact stresses (surface pressure, von Mises stress, and hydrostatic pressure) in the cartilage. A reduction of cartilage thickness caused increases of contact stresses, while an increase of cartilage thickness reduced contact stresses. Furthermore, the effect of variation of material properties of the cartilage on contact stress analysis was investigated. The peak contact stress increased almost linearly with the Young's modulus of the cartilage. The peak von Mises stress was dramatically reduced when the Poisson,s ratio was increased from 0.05 to 0.49 under an axial compressive load of 1,400 N, while peak hydrostatic pressure was dramatically increased. Peak surface pressure was also increased with the Poisson's ratio, but with a lower magnitude compared to von Mises stress and hydrostatic pressure. In conclusion, the imaging process may cause 10 percent variations in peak contact stress, and the predicted stress distribution is sensitive to the accuracy of the material properties of the cartilage model, especially to the variation of Poisson's ratio.  相似文献   

8.
A 3D anatomically based patient-specific finite element (FE) model of patello-femoral (PF) articulation is presented to analyse the main features of patella biomechanics, namely, patella tracking (kinematics), quadriceps extensor forces, surface contact and internal patella stresses. The generic geometries are a subset from the model database of the International Union of Physiological Sciences (IUPS) (http://www.physiome.org.nz) Physiome Project with soft tissue derived from the widely used visible human dataset, and the bones digitised from an anatomically accurate physical model with muscle attachment information. The models are customised to patient magnetic resonance images using a variant of free-form deformation, called 'host-mesh' fitting. The continuum was solved using the governing equation of finite elasticity, with the multibody problem coupled through contact mechanics. Additional constraints such as tissue incompressibility are also imposed. Passive material properties are taken from the literature and implemented for deformable tissue with a non-linear micro-structurally based constitutive law. Bone and cartilage are implemented using a 'St-Venant Kirchoff' model suitable for rigid body rotations. The surface fibre directions have been estimated from anatomy images of cadaver muscle dissections and active muscle contraction was based on a steady-state calcium-tension relation. The 3D continuum model of muscle, tendon and bone is compared with experimental results from the literature, and surgical simulations performed to illustrate its clinical assessment capabilities (a Maquet procedure for reducing patella stresses and a vastus lateralis release for a bipartite patella). Finally, the model limitations, issues and future improvements are discussed.  相似文献   

9.
Objective: Develop a finite element (FE) model of a skull to perform biomechanical studies of maxillary expansion using bone anchors (BA).

Materials and methods: A skull model was developed and assigned material properties based on Hounsfield unit (HU) values of cone-beam computerized tomography (CBCT) images. A 3 mm diameter cylindrical BA was modelled and inserted in the palatal bone. A 4 mm transverse displacement was applied on the anchor. An evaluation on the effect on local stresses of BA implantation inclination angle was performed.

Results: Proper displacement results and strain–stress trends for the expansion process were present. Stress distribution patterns were similar as reported in the literature. No significant difference between BA inclination angles was found.

Conclusion: This work leads to a better understanding and prediction of craniofacial and maxillary bone remodelling during ME with BA treatments and is a first step towards the development of patient specific treatments.  相似文献   

10.
OBJECTIVE: Develop a finite element (FE) model of a skull to perform biomechanical studies of maxillary expansion using bone anchors (BA). MATERIALS AND METHODS: A skull model was developed and assigned material properties based on Hounsfield unit (HU) values of cone-beam computerized tomography (CBCT) images. A 3 mm diameter cylindrical BA was modelled and inserted in the palatal bone. A 4 mm transverse displacement was applied on the anchor. An evaluation on the effect on local stresses of BA implantation inclination angle was performed. RESULTS: Proper displacement results and strain-stress trends for the expansion process were present. Stress distribution patterns were similar as reported in the literature. No significant difference between BA inclination angles was found. CONCLUSION: This work leads to a better understanding and prediction of craniofacial and maxillary bone remodelling during ME with BA treatments and is a first step towards the development of patient specific treatments.  相似文献   

11.
The development of a three-dimensional finite element model of a posteriorly plated canine cervical spine (C3-C6) including contact nonlinearities is described. The model was created from axial CT scans and the material properties were derived from the literature. The model demonstrated sufficient accuracy from the results of a mesh convergence test. Significant steps were taken toward establishing model validation by comparison of plate surface strains with a posteriorly plated canine cervical spine under three-point bending. This model was developed to better characterize the contact pressures at the various interfaces under average physiologic canine loading. The analysis showed that the screw-plate interfaces had the highest values of all the mechanical parameters evaluated.  相似文献   

12.
Wu W  Wang WQ  Yang DZ  Qi M 《Journal of biomechanics》2007,40(11):2580-2585
Coronary restenosis after angioplasty has been reduced by stenting procedure, but in-stent restenosis (ISR) has not been eliminated yet, especially in tortuous vessels. In this paper, we proposed a finite element method (FEM) to study the expansion of a stent in a curved vessel (the CV model) and their interactions. A model of the same stent in a straight vessel (the SV model) was also studied and mechanical parameters of both models were researched and compared, including final lumen area, tissue prolapse between stent struts and stress distribution. Results show that in the CV model, the vessel was straightened by stenting and a hinge effect can be observed at extremes of the stent. The maximum tissue prolapse of the CV model was more severe (0.079 mm) than the SV model (0.048 mm); and the minimum lumen area of the CV was decreased (6.10 mm(2)), compared to that of the SV model (6.28 mm(2)). Tissue stresses of the highest level were concentrated in the inner curvature of the CV model. The simulations offered some explanations for the clinical results of ISR in curved vessels and gave design suggestions of the stent and balloon for tortuous vessels. This FEM provides a tool to study mechanisms of stents in curved vessels and can improve new stent designs especially for tortuous vessels.  相似文献   

13.
14.
15.
Extracortical bone growth with osseointegration of bone onto the shaft of massive bone tumour implants is an important clinical outcome for long-term implant survival. A new computational algorithm combining geometrical shape changes and bone adaptation in 3D Finite Element simulations has been developed, using a soft tissue envelope mesh, a novel concept of osteoconnectivity, and bone remodelling theory. The effects of varying the initial tissue density, spatial influence function and time step were investigated. The methodology demonstrated good correspondence to radiological results for a segmental prosthesis.  相似文献   

16.
The modal analysis of a human tibia consisted of characterizing its dynamic behavior by determining natural frequency, damping ratio and mode shapes. Two methods were used to perform the modal analysis: (1) a finite element method (structural model); (2) an experimental modal analysis (modal model). The experimental modal model was used to optimize the structural model. After optimization, differences in results between the two models were found to be due only to mechanical properties and mass distribution. The influences of boundary conditions and geometric properties (such as inertia and length) were eliminated by the finite element model itself. The percent relative error between the two methods was approximately 3%, corresponding to the standard deviation of the measured frequencies. For the frequency range considered, the mode shapes were bending modes in two different vibration planes (latero-medial and sagittal), with a slight torsion effect due to the twisted geometry of the tibia.  相似文献   

17.
Biomechanics and Modeling in Mechanobiology - In orthopaedics, conventional implant plates such as locking compression plate (LCP) made from non-biodegradable materials play a vital role in the...  相似文献   

18.
Objectives: The accuracy of cone-beam technique, cone-beam computed tomography (CBCT), compared with that of the multislice spiral CT (MSCT), for image-based linear measurements of midpalatal suture was assessed.

Material and Methods: Two measurements were performed by one investigator on the dry skull by using one digital caliper and in the axial cuts by using software. A 2D object-based image registration process was applied to determine the best affine transformation that maps a 2D input image (CBCT) in a reference image (MSCT).

Results: The value of the intraclass correlation coefficient was approximately 0.9%. The results suggest that differences between two scanners did not exist (observation 1, p = 0.964 and observation 2, p = 0.795). With regard to the dry skull and the image, the significance probabilities equaled zero (observation 1, p = 0.002 and observation 2, p = 0.004), therefore, indicating significant differences.

Conclusion: Measurements acquired in the images were similar and these findings contribute to stimulate the use of CBCT for evaluation of the maxillary expansion procedure.  相似文献   

19.
20.
To enable large-scale multi-factorial finite element (FE) studies, the FE models used must be as computationally efficient as is feasible, while maintaining a suitable level of definition. The present study seeks to find an optimum level of model complexity for use in such large-scale studies by investigating which model attributes are most influential over the chosen model outputs of principal stress and strain in the intact acetabulum. A multi-factorial sensitivity study was carried out using 128 FE models, representing combinations of the following variables: bone stiffness distribution, imposed muscle loading, boundary condition location, hip joint contact conditions and patient's bone anatomy. The relative sensitivity of each input factor was analysed, and it was concluded that the optimum level of model definition must include CT-dependent trabecular bone properties and a sliding interface at the hip joint. It was found that it was not essential to describe the ligamentous sacroiliac and pubic symphysis joints; these could be rigidly fixed in space; and for the normal walking load case, muscle forces may be neglected. It was also concluded that a variety of bone anatomies should be included in a multi-factorial analysis if results are to be inferred for a wider population.  相似文献   