首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A model for fluid and drug transport through the leaky neovasculature and porous interstitium of a solid tumour is developed. The transport problems are posed on a micro-scale characterized by the inter-capillary distance, and the method of multiple scales is used to derive the continuum equations describing fluid and drug transport on the length scale of the tumour (under the assumption of a spatially periodic microstructure). The fluid equations comprise a double porous medium, with coupled Darcy flow through the interstitium and vasculature, whereas the drug equations comprise advection–reaction equations; in each case the dependence of the transport coefficients on the vascular geometry is determined by solving micro-scale cell problems.  相似文献   

2.
低功率高频超声抑制蓝藻生长的研究   总被引:7,自引:0,他引:7  
为防治蓝藻水华,从超声的生物效应出发提出了新的抑藻思路。低功率高频(1.7MHz)超声高效节能地破坏藻胆体和叶绿素等蓝藻天线复合物的关键组分,或抑制其生物合成,导致光合作用受阻,从而抑制蓝藻生长。在纯顶螺旋藻对照实验中,5min超声辐照为最佳处理时间,可显著降低蓝藻浓度,并使其生长速度大大减缓。实验发现藻蓝蛋白受到的超声破坏作用尤其强烈,即高频超声对蓝藻细胞不同成分的破坏具有选择性,据此提出了高频超声量子效应的解释。  相似文献   

3.
Current diagnosis of bone loss and osteoporosis is based on the measurement of the bone mineral density (BMD) or the apparent mass density. Unfortunately, in most clinical ultrasound densitometers: 1) measurements are often performed in a single anatomical direction, 2) only the first wave arriving to the ultrasound probe is characterized, and 3) the analysis of bone status is based on empirical relationships between measurable quantities such as speed of sound (SOS) and broadband ultrasound attenuation (BUA) and the density of the porous medium. However, the existence of a second wave in cancellous bone has been reported, which is an unequivocal signature of poroelastic media, as predicted by Biot’s poroelastic wave propagation theory. In this paper, the governing equations for wave motion in the linear theory of anisotropic poroelastic materials are developed and extended to include the dependence of the constitutive relations upon fabric—a quantitative stereological measure of the degree of structural anisotropy in the pore architecture of a porous medium. This fabric-dependent anisotropic poroelastic approach is a theoretical framework to describe the microarchitectural-dependent relationship between measurable wave properties and the elastic constants of trabecular bone, and thus represents an alternative for bone quality assessment beyond BMD alone.  相似文献   

4.
ABSTRACT: Tumor shape and size effect on drug delivery to solid tumors are studied, based on the application of the governing equations for fluid flow, i.e., the conservation laws for mass and momentum, to physiological systems containing solid tumors. The discretized form of the governing equations, with appropriate boundary conditions, is developed for predefined tumor geometries. The governing equations are solved using a numerical method, the element-based finite volume method. Interstitial fluid pressure and velocity are used to show the details of drug delivery in a solid tumor, under an assumption that drug particles flow with the interstitial fluid. Drug delivery problems have been most extensively researched in spherical tumors, which have been the simplest to examine with the analytical methods. With our numerical method, however, more complex shapes of the tumor can be studied. The numerical model of fluid flow in solid tumors previously introduced by our group is further developed to incorporate and investigate non-spherical tumors such as prolate and oblate ones. Also the effects of the surface area per unit volume of the tissue, vascular and interstitial hydraulic conductivity on drug delivery are investigated.  相似文献   

5.
Thyroid echography was carried out on 100 patients with thyroid abnormalities to evaluate the diagnostic accuracy of ultrasound in differentiating simple thyroid cysts from solid thyroid nodules.In all 46 proven cases, the ultrasonic diagnosis of the solid or cystic nature of thyroid nodules was correct.A proposed diagnostic workup of a hypofunctioning (cold) thyroid nodule is suggested with primary needle aspiration and cytologic examination of the cyst fluid being recommended if the nodule is shown to be entirely cystic by ultrasound.  相似文献   

6.
Interstitial fluid is a solution that bathes and surrounds the human cells and provides them with nutrients and a way of waste removal. It is generally believed that elevated tumor interstitial fluid pressure (IFP) is partly responsible for the poor penetration and distribution of therapeutic agents in solid tumors, but the complex interplay of extravasation, permeabilities, vascular heterogeneities and diffusive and convective drug transport remains poorly understood. Here we consider–with the help of a theoretical model–the tumor IFP, interstitial fluid flow (IFF) and its impact upon drug delivery within tumor depending on biophysical determinants such as vessel network morphology, permeabilities and diffusive vs. convective transport. We developed a vascular tumor growth model, including vessel co-option, regression, and angiogenesis, that we extend here by the interstitium (represented by a porous medium obeying Darcy''s law) and sources (vessels) and sinks (lymphatics) for IFF. With it we compute the spatial variation of the IFP and IFF and determine its correlation with the vascular network morphology and physiological parameters like vessel wall permeability, tissue conductivity, distribution of lymphatics etc. We find that an increased vascular wall conductivity together with a reduction of lymph function leads to increased tumor IFP, but also that the latter does not necessarily imply a decreased extravasation rate: Generally the IF flow rate is positively correlated with the various conductivities in the system. The IFF field is then used to determine the drug distribution after an injection via a convection diffusion reaction equation for intra- and extracellular concentrations with parameters guided by experimental data for the drug Doxorubicin. We observe that the interplay of convective and diffusive drug transport can lead to quite unexpected effects in the presence of a heterogeneous, compartmentalized vasculature. Finally we discuss various strategies to increase drug exposure time of tumor cells.  相似文献   

7.
超声波检测骨密度技术研究   总被引:1,自引:0,他引:1  
人体骨密度能够体现人体的很多信息,如骨质疏松、骨折、骨龄等。研究利用超声波在固体中产生波形转换的原理,采用一种特殊角度的双晶探头。利用定量超声技术检测出胫骨中超声横波的传播速度SOS(speedofsound),从中得到的骨密度信息,能够从一种新的角度来对估量减少,骨质疏松进行诊断和预测。分别对不同年龄层的人进行实验。得到的结果验证了系统的正确性。  相似文献   

8.
The aim of this study was to investigate the effects of tablet porosity and particle size fraction of compacted Starch acetate powders, with and without model drug caffeine, on acoustic properties of tablets. The ultrasound velocity was determined from the transmission measurements. Tablets of starch acetate (SA DS 2.7) powder with two particle size fractions of 0–53 and 0–710 μm were compressed with a compaction simulator. Porosities of tablets varied in the range from 12% to 43% for both particle size fractions. Strong associations were found between the ultrasound velocity and physical properties of the tablets such as porosity and particle size fraction. Interestingly, ultrasound velocity was practically insensitive to inclusion of the model drug caffeine with the concentrations used. Based on this study ultrasound transmission method is a potential non-destructive tool for studying structural changes of tablets and other solid dosage forms.  相似文献   

9.
The ultrastructure of staphylococci from the peritoneal fluid of mice treated with oxacillin and from sputum of a patient treated with ampicillin was comparable to the structure of staphylococci grown on filter membranes exposed to oxacillin, but was different from the same organisms grown in broth with oxacillin. The selection of a solid phase support growth medium, such as a filter membrane for in vitro studies of drug induced morphology, appears necessary if such studies are to reflect bacterial ultrastructure in vivo.  相似文献   

10.
11.
12.
Fine needle aspiration (FNA) was performed on 102 hepatic lesions under ultrasound control. Eighty-eight lesions were solid and 14 were cystic. Ninety aspirates provided adequate material for cytodiagnosis. Aspirates from the solid lesions were assessed for the presence or absence of 20 cytological features. It was found that on a univariate statistical analysis, 11 of the features were significantly associated with hepatocellular carcinomas. Five of these 11 were considered diagnostic of the lesion on a step-wise multiple linear regression analysis. Two other features (not included among the 11) were found to be significantly associated with metastatic neoplasms. Cystic lesions were diagnosed as being either abscesses, hydatid cysts or congenital cysts. the physical appearance of the cyst fluid proved to be of diagnostic value in many cases.  相似文献   

13.
Cancellous bone is a highly porous material, and two types of waves, fast and slow, are observed when ultrasound is used for detecting bone diseases. There are several possible stimuli for bone remodelling processes, including bone fluid flow, streaming potential, and piezoelectricity. Poroelasticity has been widely used for elucidating the bone fluid flow phenomenon, but the combination of poroelasticity with charge density has not been introduced. Theoretically, general poroelasticity with a varying charge density is employed for determining the relationship between wave velocity and attenuation with charge density. Fast wave velocity and attenuation are affected by porosity as well as charge density; however, for a slow wave, both slow wave velocity and attenuation are not as sensitive to the effect of charge density as they are for a fast wave. Thus, employing human femoral data, we conclude that charged ions gather on trabecular struts, and the fast wave, which moves along the trabecular struts, is significantly affected by charge density.  相似文献   

14.
目的:探讨剪切波弹性成像在乳腺实性病变良恶性鉴别中的诊断价值。方法:收集2012年3月-2013年6月于我院收治的乳腺实性病变患者54例,共65个病灶,先后给予乳腺二维超声检查与剪切波弹性成像检查,采用弹性模量值与钼靶BI-RADS分级方法诊断,比较两种方法诊断的准确性。结果:良性病灶组弹性最小、最大值以及平均值、标准差与恶性病灶组比较差异具有统计学意义(P0.05);ROC曲线分析显示,在乳腺实性病变良恶性的鉴别中,弹性最大值明显优于平弹性均值;剪切波弹性成像对乳腺实性病变良恶性鉴别的敏感度、特异度、准确度、阳性预测值、阴性预测值高于二维超声技术(P0.05)。结论:剪切波弹性成像在乳腺实性病变良恶性鉴别中具有良好的诊断价值,能够提高诊断的准确性。  相似文献   

15.
Solid lipid nanoparticles (SLNs) of duloxetine hydrochloride (DLX) were prepared to circumvent the problems of DLX, which include acid labile nature, high first-pass metabolism, and high-dosing frequency. The DLX-SLNs were prepared by using two different techniques, viz. solvent diffusion method and ultrasound dispersion method, and evaluated for particle size, zeta potential, entrapment efficiency, physical characteristics, and chemical stability. Best results were obtained when SLNs were prepared by ultrasound dispersion method using glyceryl mono stearate as solid lipid and DLX in ratio of 1:20 and mixture of polysorbate 80 and poloxamer 188 as surfactant in concentration of 3%. The mean particle size of formulation and entrapment efficiency was 91.7 nm and 87%, respectively, and had excellent stability in acidic medium. Differential scanning calorimetry and X-ray diffraction data showed complete amorphization of DLX in lipid. In vitro drug release from SLNs was observed for 48 h and was in accordance with Higuchi kinetics. In vivo antidepressant activity was evaluated in mice by forced swim test. DLX-SLNs showed significant enhancement in antidepressant activity at 24 h when administered orally in comparison to drug solution. These results confirm the potential of SLNs in enhancing chemical stability and improving the efficacy of DLX via oral route. The SLN dispersion was converted into solid granules by adsorbing on colloidal silicon dioxide and characterized for particle size after redispersion, morphology, and flow properties. Results indicated that nanoparticles were successfully adsorbed on the carrier and released SLNs when dispersed in water.  相似文献   

16.
The effect of cytochalasin B on F-actin amount and organization was measured in chick embryo fibroblasts (CEF) grown on solid substratum at low density, at high density, and suspended in a fluid medium. It was found that: 1) Cytochalasin B induced decrease in F-actin content only in cells growing at low density, in density-inhibited or suspended cells cytochalasin B had no effect on F-actin amount. 2) In cells grown at low density F-actin filaments organized in stress fibers are more resistant to cytochalasin B than F-actin which is not organized in fibrils. In cell density-inhibited or suspended in a fluid medium F-actin filaments are insensitive to the action of cytochalasin B, although they are not organized in stress fibers. These results are interpreted to reflect the influence of contact reactions on treadmilling in F-actin filaments.  相似文献   

17.
The purpose of this report was to compile relevant technical information on various alternative strategies that can be used as feasible approaches in the development of solid dispersions. The technologies discussed in the report are spray coating on sugar beads with a fluidized bed coating system, hot melt extrusion, direct capsule filling, electrostatic spinning, surface active carriers, and supercritical fluid technology. The focus is on basic principles, the equipment involved, and the relevant scale-up work. These technologies have been found to eliminate several drawbacks posed by the conventional methods of manufacturing of solid dispersions such as laborious preparation methods, reproducibility, scaling up of manufacturing processes, stability of drug, and vehicle.  相似文献   

18.
Mechanics of articular cartilage can be represented using poroelastic theories where fluid and solid displacements are viscously coupled to create a time-dependent spatially heterogeneous behavior. In recent models of this tissue, finite element methods have been used to predict tissue deformation as a function of time for adult articular cartilage bearing a characteristic depth-dependent structure and composition. However, current experimental methods are limited in providing verification of these predictions. The current study presents an apparatus for imaging the radial displacement profile of cartilage in unconfined compression using an ultrasound technique called elastography. We acquired ultrasound A-scans across the lateral diameter of full-thickness cartilage disks containing a thin layer of underlying bone, during axial compression. Elastography was then applied to correlate temporally sequential A-scans to estimate the solid radial displacement profile in articular cartilage while it undergoes compression and stress-relaxation. Both time-dependent and depth-dependent solid radial displacement profiles were obtained with a precision better than 0.2 micro The results generally agree with predictions of poroelastic models, demonstrating lateral expansion with an effective Poisson's ratio just after completion of the compression phase of the mechanical tests reaching values from 0.18 to 0.4 (depending on compression speed), followed by contraction to lower values. A more restricted movement was observed at both the articular surface and near to the subchondral bone than at regions midway between these two locations.  相似文献   

19.
Transdermal drug delivery offers an attractive alternative to injections and oral medications. However, applications of transdermal drug delivery are limited to only a few drugs as a result of low skin permeability. Application of low-frequency ultrasound enhances skin permeability, a phenomenon referred to as low-frequency sonophoresis. In this method, a short application of ultrasound is used to permeabilize skin for a prolonged period of time. During this period, ultrasonically permeabilized skin may be utilized for drug delivery. In addition, a sample of interstitial fluid or its components may be extracted through permeabilized skin for diagnostic applications. In this paper, we report our in vivo studies that demonstrate the principles of both of these concepts. Detailed studies on drug delivery are performed using inulin and mannitol as model drugs. Studies on diagnostics are performed using glucose as a model analyte. Applications of this technology to drug delivery and diagnostics are discussed.  相似文献   

20.
The purpose of this study was to develop and evaluate a solid nonaqueous oral dosage form for a new hepatitis C drug, PG301029, which is insoluble and unstable in water. Hydroxypropyl-β-cyclodextrin (HPβCD) and PG301029 were dissolved in glacial acetic acid. The acetic acid was removed by rotoevaporation such that the drug exists primarily in the complexed form. The stability of formulated PG301029 was determined upon dry storage and after reconstitution in simulated intestinal fluid (SIF), simulated gastric fluid (SGF), and water. Formulated PG301029 was found to be stable upon storage and can be reconstituted with water to a concentration 200 times that of the intrinsic solubility. Once reconstituted, the powder dissolves rapidly and PG301029 remains stable for 21 hours in SGF, SIF, and water. The unique use of acetic acid and HPβCD results in a solid dosage form of PG301029 that is both soluble and stable in water. Published: February 24, 2006  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号