首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Rationale

Adipose tissue produces adiponectin, an anti-inflammatory protein. Adiponectin deficiency in mice is associated with abnormal post-natal alveolar development.

Objective

We hypothesized that lower serum adiponectin concentrations are associated with lower lung function in humans, independent of obesity. We explored mediation of this association by insulin resistance and systemic inflammation.

Methods and Measurements

Spirometry testing was conducted at years 10 and 20 follow-up evaluation visits in 2,056 eligible young adult participants in the Coronary Artery Risk Development in Young Adults (CARDIA) study. Body mass index, serum adiponectin, serum C-reactive protein (a marker of systemic inflammation), and insulin resistance were assessed at year 15.

Main Results

After controlling for body mass index, years 10 and 20 forced vital capacity (FVC) were 81 ml and 82 ml lower respectively (p = 0.004 and 0.01 respectively) in the lowest vs. highest adiponectin quartiles. Similarly, years 10 and 20 forced expiratory volume in one second (FEV1) were 50 ml and 38 ml lower (p = 0.01 and 0.09, respectively) in the lowest vs. highest adiponectin quartiles. These associations were no longer significant after adjustment for insulin resistance and C-reactive protein. Serum adiponectin was not associated with FEV1/FVC or peak FEV1.

Conclusions

Independent of obesity, lower serum adiponectin concentrations are associated with lower lung function. The attenuation of this association after adjustment for insulin resistance and systemic inflammation suggests that these covariates are on a causal pathway linking adiponectin and lung function.  相似文献   

2.

Backgrounds/objectives

Evidence on the association between physical activity and lung function in children is sparse. The aim of this study was to evaluate children’s lung function growth in relation to their physical activity level in Chinese children.

Methods

A total of 1713 school children aged 9.89±0.86 years who were asthma-free at baseline were followed-up for 18 months from 2006 to 2008 in Guangzhou, China. Information on physical activity and other socio-economic status were obtained from self-administered questionnaires. Lung function tests were performed with a standard procedure.

Results

At the baseline survey, physically active girls had significantly higher forced vital capacity (FVC) than inactive girls (1.79 l vs. 1.75 l, p<0.05). The growth rates for lung function indices were significantly higher for girls who were physically active at either or both follow-up surveys than those inactive at both surveys during the follow-up period forced expiratory flows at 25% (FEF25) difference per year (dpy) (0.20 l/s vs. 0.15 l/s), forced expiratory flows at 75% (FEF75) dpy (0.57 l/s vs. 0.45 l/s) and forced expiratory flows between 25% and 75% (FEF25-75) dpy (0.36 l/s vs. 0.28 l/s) (all p<0.05).

Conclusions

Physical activity is positively associated with lung function growth among Chinese school-aged girls. Promotion of physical activity among children is of great importance.  相似文献   

3.

Purpose

We aimed to study the association between lung function decline and quantitative computed tomography (CT) air trapping.

Materials and Methods

Current and former heavy smokers in a lung cancer screening trial underwent volumetric low-dose CT in inspiration and expiration. Spirometry was obtained at baseline and after 3 years. The expiratory to inspiratory ratio of mean lung density (E/I-ratioMLD) was used to quantify air trapping. CT emphysema was defined as voxels in inspiratory CT below −950 Hounsfield Unit. Linear mixed modeling was used to determine the association between CT air trapping and lung function.

Results

We included 985 subjects with a mean age of 61.3 years. Independent of CT emphysema, CT air trapping was significantly associated with a reduction in forced expiratory volume in one second (FEV1) and the ratio of FEV1 over the forced vital capacity (FEV1/FVC); FEV1 declines with 33 mL per percent increase in CT air trapping, while FEV1/FVC declines 0.58% per percent increase (both p<0.001). CT air trapping further elicits accelerated loss of FEV1/FVC (additional 0.24% reduction per percent increase; p = 0.014).

Conclusion

In a lung cancer screening cohort, quantitatively assessed air trapping on low-dose CT is independently associated with reduced lung function and accelerated decline of FEV1/FVC.  相似文献   

4.

Background and objective

This study examined whether zinc intake was associated with lower risk of smoking-induced obstructive lung disorder through interplay with cadmium, one of major toxicants in cigarette smoke.

Methods

Data were obtained from a sample of 6,726 subjects aged 40+ from the Third National Health and Nutrition Examination Survey. The forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) were measured using spirometry. Gender-, ethnicity-, and age-specific equations were used to calculate the lower limit of normal (LLN) to define obstructive lung disorder as: observed FEV1/FVC ratio and FEV1 below respective LLN. Zinc intake was assessed by questionnaire. Logistic regression analysis was applied to investigate the associations of interest.

Results

The analyses showed that an increased prevalence of obstructive lung disorder was observed among individuals with low zinc intake regardless of smoking status. The adjusted odds of lung disorder are approximately 1.9 times greater for subjects in the lowest zinc-intake tertile than those in the highest tertile (odds ratio = 1.89, 95% confidence interval = 1.22-2.93). The effect of smoking on lung function decreased considerably after adjusting for urinary cadmium. Protective association between the zinc-to-cadmium ratio (log-transformed) and respiratory risk suggests that zinc may play a role in smoking-associated lung disorder by modifying the influence of cadmium.

Conclusions

While zinc intake is associated with lower risk of obstructive lung disorder, the role of smoking cession and/or prevention are likely to be more important given their far greater effect on respiratory risk. Future research is warranted to explore the mechanisms by which zinc could modify smoking-associated lung disease.  相似文献   

5.

Background

Little is known about the influencing potential of specific characteristics on lung function in different populations. The aim of this analysis was to determine whether lung function determinants differ between subpopulations within Germany and whether prediction equations developed for one subpopulation are also adequate for another subpopulation.

Methods

Within three studies (KORA C, SHIP-I, ECRHS-I) in different areas of Germany 4059 adults performed lung function tests. The available data consisted of forced expiratory volume in one second, forced vital capacity and peak expiratory flow rate. For each study multivariate regression models were developed to predict lung function and Bland-Altman plots were established to evaluate the agreement between predicted and measured values.

Results

The final regression equations for FEV1 and FVC showed adjusted r-square values between 0.65 and 0.75, and for PEF they were between 0.46 and 0.61. In all studies gender, age, height and pack-years were significant determinants, each with a similar effect size. Regarding other predictors there were some, although not statistically significant, differences between the studies. Bland-Altman plots indicated that the regression models for each individual study adequately predict medium (i.e. normal) but not extremely high or low lung function values in the whole study population.

Conclusions

Simple models with gender, age and height explain a substantial part of lung function variance whereas further determinants add less than 5% to the total explained r-squared, at least for FEV1 and FVC. Thus, for different adult subpopulations of Germany one simple model for each lung function measures is still sufficient.  相似文献   

6.

Background

The obese-asthma phenotype is not well defined. The aim of this study was to examine both mechanical and inflammatory influences, by comparing lung function with body composition and airway inflammation in overweight and obese asthma.

Methods

Overweight and obese (BMI 28-40 kg/m2) adults with asthma (n = 44) completed lung function assessment and underwent full-body dual energy x-ray absorptiometry. Venous blood samples and induced sputum were analysed for inflammatory markers.

Results

In females, android and thoracic fat tissue and total body lean tissue were inversely correlated with expiratory reserve volume (ERV). Conversely in males, fat tissue was not correlated with lung function, however there was a positive association between android and thoracic lean tissue and ERV. Lower body (gynoid and leg) lean tissue was positively associated with sputum %neutrophils in females, while leptin was positively associated with android and thoracic fat tissue in males.

Conclusions

This study suggests that both body composition and inflammation independently affect lung function, with distinct differences between males and females. Lean tissue exacerbates the obese-asthma phenotype in females and the mechanism responsible for this finding warrants further investigation.  相似文献   

7.

Background

The relationship between patient-reported symptoms and objective measures of lung function is poorly understood.

Aim

To determine the association between responsiveness to bronchodilator and respiratory symptoms in random population samples.

Methods

4669 people aged 40 years and older from 8 sites in Canada completed interviewer-administered respiratory questionnaires and performed spirometry before and after administration of 200 ug of inhaled salbutamol. The effect of anthropometric variables, smoking exposure and doctor-diagnosed asthma (DDA) on bronchodilator responsiveness in forced expiratory volume in 1 second (FEV1) and in forced vital capacity (FVC) were evaluated. Multiple logistic regression was used to test for association between quintiles of increasing changes in FEV1 and in FVC after bronchodilator and several respiratory symptoms.

Results

Determinants of bronchodilator change in FEV1 and FVC included age, DDA, smoking, respiratory drug use and female gender [p<0.005 to p<0.0001 ]. In subjects without doctor-diagnosed asthma or COPD, bronchodilator response in FEV1 was associated with wheezing [p for trend<0.0001], while bronchodilator response for FVC was associated with breathlessness. [p for trend <0.0001].

Conclusions

Bronchodilator responsiveness in FEV1 or FVC are associated with different respiratory symptoms in the community. Both flow and volume bronchodilator responses are useful parameters which together can be predictive of both wheezing and breathlessness in the general population.  相似文献   

8.

Background

Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers.

Methods

Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT). CTs were analyzed with software, which allows quantification of total emphysema (emphysema%). The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models.

Results

A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1)%, and forced vital capacity (FVC)% fit best with the rib cage measurements (R2 = 64% for the rib cage area variation at the lower anatomical level). Gender had the biggest impact on rib cage diameter and area (105.3 cm2; 95% CI: 111.7 to 98.8 for male lower area). Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%). Lower rib cage areas decreased as FVC% decreased (5.1 cm2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation).

Conclusions

This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.  相似文献   

9.

Objective

To determine the impact of sarcopenia and obesity on pulmonary function and quality of life (QOL) in chronic obstructive pulmonary disease (COPD) patients.

Research Design and Methods

Data were obtained from the Korea National Health and Nutrition Examination Survey, including data from health interviews, health examinations, nutritional questionnaires, and laboratory findings. Laboratory data included pulmonary function assessment and dual energy X-ray absorptiometry results. Sarcopenia was measured by dual energy X-ray absorptiometry, and obesity was defined by body mass index. Male COPD patients were then classified into 4 groups according to the presence of sarcopenia and obesity.

Results

In male patients with COPD, the prevalence of sarcopenia was found to be 29.3%, and that of sarcopenic obesity was 14.2%. Furthermore, 22.5% of the patients observed in this study had impaired QOL. Following multivariable statistical analysis, both sarcopenia and obesity were independent risk factors for worsening lung function. Adjusted values of forced vital capacity and forced expiratory volume in 1 second were the lowest in the sarcopenic obesity group. Sarcopenia was also associated with more subjective activity limitation and poorer QOL; however obesity was related to less subjective limitation and better QOL after multivariable analysis. Adjusted value of QOL was the lowest in sarcopenic subjects without obesity, and the highest in obese subject without sarcopenia.

Conclusions

Both sarcopenia and obesity were found to be associated with worsening lung function in male COPD patients. However, obesity was positively correlated with improved QOL while sarcopenia was negatively correlated with QQL.  相似文献   

10.

Background and Objectives

Poor adherence to medications is one of the major public health challenges. Only one-third of the population reported successful control of blood pressure, mostly caused by poor drug adherence. However, there are relatively few reports studying the adherence levels and their associated factors among Chinese patients. This study aimed to study the adherence profiles and the factors associated with antihypertensive drug adherence among Chinese patients.

Methods

A cross-sectional study was conducted in an outpatient clinic located in the New Territories Region of Hong Kong. Adult patients who were currently taking at least one antihypertensive drug were invited to complete a self-administered questionnaire, consisting of basic socio-demographic profile, self-perceived health status, and self-reported medication adherence. The outcome measure was the Morisky Medication Adherence Scale (MMAS-8). Good adherence was defined as MMAS scores greater than 6 points (out of a total score of 8 points).

Results

From 1114 patients, 725 (65.1%) had good adherence to antihypertensive agents. Binary logistic regression analysis was conducted. Younger age, shorter duration of antihypertensive agents used, job status being employed, and poor or very poor self-perceived health status were negatively associated with drug adherence.

Conclusion

This study reported a high proportion of poor medication adherence among hypertensive subjects. Patients with factors associated with poor adherence should be more closely monitored to optimize their drug taking behavior.  相似文献   

11.

Background

Chronic obstructive pulmonary disease (COPD) is characterized by expiratory flow limitation, causing air trapping and lung hyperinflation. Hyperinflation leads to reduced exercise tolerance and poor quality of life in COPD patients. Total lung capacity (TLC) is an indicator of hyperinflation particularly in subjects with moderate-to-severe airflow obstruction. The aim of our study was to identify genetic variants associated with TLC in COPD.

Methods

We performed genome-wide association studies (GWASs) in white subjects from three cohorts: the COPDGene Study; the Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints (ECLIPSE); and GenKOLS (Bergen, Norway). All subjects were current or ex-smokers with at least moderate airflow obstruction, defined by a ratio of forced expiratory volume in 1 second to forced vital capacity (FEV1/FVC) <0.7 and FEV1 < 80% predicted on post-bronchodilator spirometry. TLC was calculated by using volumetric computed tomography scans at full inspiration (TLCCT). Genotyping in each cohort was completed, with statistical imputation of additional markers. To find genetic variants associated with TLCCT, linear regression models were used, with adjustment for age, sex, pack-years of smoking, height, and principal components for genetic ancestry. Results were summarized using fixed-effect meta-analysis.

Results

Analysis of a total of 4,543 COPD subjects identified one genome-wide significant locus on chromosome 5p15.2 (rs114929486, β = 0.42L, P = 4.66 × 10−8).

Conclusions

In COPD, TLCCT was associated with a SNP in dynein, axonemal, heavy chain 5 (DNAH5), a gene in which genetic variants can cause primary ciliary dyskinesia. DNAH5 could have an effect on hyperinflation in COPD.

Electronic supplementary material

The online version of this article (doi:10.1186/s12931-014-0097-y) contains supplementary material, which is available to authorized users.  相似文献   

12.

Background

Reduced forced expiratory volume in 1 second (FEV1) and the ratio of FEV1 to forced vital capacity (FVC) are strong predictors of mortality and lung function is higher among individuals with exceptional longevity. However, genetic factors associated with lung function in individuals with exceptional longevity have not been identified.

Method

We conducted a genome wide association study (GWAS) to identify novel genetic variants associated with lung function in the Long Life Family Study (LLFS) (n = 3,899). Replication was performed using data from the CHARGE/SpiroMeta consortia. The association between SNPs and FEV1 and FEV1/FVC was analyzed using a linear mixed effects model adjusted for age, age2, sex, height, field center, ancestry principal components and kinship structure to adjust for family relationships separately for ever smokers and never smokers. In the linkage analysis, we used the residuals of the FEV1 and FEV1/FVC, adjusted for age, sex, height, ancestry principal components (PCs), smoking status, pack-years, and field center.

Results

We identified nine SNPs in strong linkage disequilibrium in the CYP2U1 gene to be associated with FEV1 and a novel SNP (rs889574) associated with FEV1/FVC, none of which were replicated in the CHARGE/SpiroMeta consortia. Using linkage analysis, we identified a novel linkage peak in chromosome 2 at 219 cM for FEV1/FVC (LOD: 3.29) and confirmed a previously reported linkage peak in chromosome 6 at 28 cM (LOD: 3.33) for FEV1.

Conclusion

Future studies need to identify the rare genetic variants underlying the linkage peak in chromosome 6 for FEV1.

Electronic supplementary material

The online version of this article (doi:10.1186/s12931-014-0134-x) contains supplementary material, which is available to authorized users.  相似文献   

13.

Background

In older adults, an independent association exists between impaired lung function and cardiovascular disease. This interaction might be related to the effects of aging and/or smoking. In order to explore possible childhood antecedents to this association, we hypothesized that decreased lung function and vascular stiffness might be related, in early life.

Objective

To determine the relationship between lung function and carotid augmentation index (AIx), a measure of vascular stiffness, in 8-year old children.

Methods

Data on brachial blood pressure, lung function (FEV1, FVC, FEV1/FVC, obtained by spirometry) and carotid AIx75 (AIx standardised to an arbitrary heart rate of 75 beats per minute, obtained by applanation tonometry) was available in 249 community-based 8-year old children. These healthy children had been subjects in a randomised controlled trial of two interventions (omega-3 fatty acid supplementation and house-dust mite avoidance) to prevent asthma. Smoking in pregnancy and childhood environmental tobacco smoke (ETS) exposure was prospectively collected by questionnaire. The association between lung function and carotid AIx75 was assessed in multivariate models that included sex, height, smoking status during pregnancy, ETS exposure and randomisation groups (house dust mite avoidance and dietary intervention) as covariates.

Results

In the fully adjusted models, Carotid AIx75 was independently associated with FEV1 (standardised β = −0.17,b = −6.72, partial R2 = .02, p = 0.03), FVC (standardised β = −0.29, b = −9.31, partial R2 = 0.04, p<0.001) and FEV1/FVC (standardised β = .13, b = 18.4, partial R2 = 0.02, p = 0.04).

Conclusion

Lower lung volumes are associated with increased vascular stiffness at an early age. The interaction between lung function and vascular stiffness may thus represent more than just age-related alterations in both the pulmonary and vascular systems.  相似文献   

14.

Background

Computed tomographic (CT) airway lumen narrowing is associated with lower lung function. Although volumetric CT measures of airways (wall volume [WV] and lumen volume [LV]) compared to cross sectional measures can more accurately reflect bronchial morphology, data of their use in never smokers is scarce. We hypothesize that native tracheobronchial tree morphology as assessed by volumetric CT metrics play a significant role in determining lung function in normal subjects. We aimed to assess the relationships between airway size, the projected branching generation number (BGN) to reach airways of <2mm lumen diameter –the site for airflow obstruction in smokers- and measures of lung function including forced expiratory volume in 1 second (FEV1) and forced expiratory flow between 25% and 75% of vital capacity (FEF 25–75).

Methods

We assessed WV and LV of segmental and subsegmental airways from six bronchial paths as well as lung volume on CT scans from 106 never smokers. We calculated the lumen area ratio of the subsegmental to segmental airways and estimated the projected BGN to reach a <2mm-lumen-diameter airway assuming a dichotomized tracheobronchial tree model. Regression analysis was used to assess the relationships between airway size, BGN, FEF 25–75, and FEV1.

Results

We found that in models adjusted for demographics, LV and WV of segmental and subsegmental airways were directly related to FEV1 (P <0.05 for all the models). In adjusted models for age, sex, race, LV and lung volume or height, the projected BGN was directly associated with FEF 25–75 and FEV1 (P = 0.001) where subjects with lower FEV1 had fewer calculated branch generations between the subsegmental bronchus and small airways. There was no association between airway lumen area ratio and lung volume.

Conclusion

We conclude that in never smokers, those with smaller central airways had lower airflow and those with lower airflow had less parallel airway pathways independent of lung size. These findings suggest that variability in the structure of the tracheobronchial tree may influence the risk of developing clinically relevant smoking related airway obstruction.

Electronic supplementary material

The online version of this article (doi:10.1186/s12931-015-0181-y) contains supplementary material, which is available to authorized users.  相似文献   

15.

Background

Oxidative stress related genes modify the effects of ambient air pollution or tobacco smoking on lung function decline. The impact of interactions might be substantial, but previous studies mostly focused on main effects of single genes.

Objectives

We studied the interaction of both exposures with a broad set of oxidative-stress related candidate genes and pathways on lung function decline and contrasted interactions between exposures.

Methods

For 12679 single nucleotide polymorphisms (SNPs), change in forced expiratory volume in one second (FEV1), FEV1 over forced vital capacity (FEV1/FVC), and mean forced expiratory flow between 25 and 75% of the FVC (FEF25-75) was regressed on interval exposure to particulate matter <10 µm in diameter (PM10) or packyears smoked (a), additive SNP effects (b), and interaction terms between (a) and (b) in 669 adults with GWAS data. Interaction p-values for 152 genes and 14 pathways were calculated by the adaptive rank truncation product (ARTP) method, and compared between exposures. Interaction effect sizes were contrasted for the strongest SNPs of nominally significant genes (pinteraction<0.05). Replication was attempted for SNPs with MAF>10% in 3320 SAPALDIA participants without GWAS.

Results

On the SNP-level, rs2035268 in gene SNCA accelerated FEV1/FVC decline by 3.8% (pinteraction = 2.5×10−6), and rs12190800 in PARK2 attenuated FEV1 decline by 95.1 ml pinteraction = 9.7×10−8) over 11 years, while interacting with PM10. Genes and pathways nominally interacting with PM10 and packyears exposure differed substantially. Gene CRISP2 presented a significant interaction with PM10 (pinteraction = 3.0×10−4) on FEV1/FVC decline. Pathway interactions were weak. Replications for the strongest SNPs in PARK2 and CRISP2 were not successful.

Conclusions

Consistent with a stratified response to increasing oxidative stress, different genes and pathways potentially mediate PM10 and tobacco smoke effects on lung function decline. Ignoring environmental exposures would miss these patterns, but achieving sufficient sample size and comparability across study samples is challenging.  相似文献   

16.

Background

The use of noninvasive intermittent positive pressure ventilation (NIPPV) in chronic obstructive pulmonary disease (COPD) patients with chronic hypercapnic respiratory failure remains controversial as long-term data are almost lacking.The aim was to compare the outcome of 2-year home-based nocturnal NIPPV in addition to rehabilitation (NIPPV + PR) with rehabilitation alone (PR) in COPD patients with chronic hypercapnic respiratory failure.

Methods

Sixty-six patients could be analyzed for the two-year home-based follow-up period. Differences in change between the NIPPV + PR and PR group were assessed by a linear mixed effects model with a random effect on the intercept, and adjustment for baseline values. The primary outcome was health-related quality of life (HRQoL); secondary outcomes were mood state, dyspnea, gas exchange, functional status, pulmonary function, and exacerbation frequency.

Results

Although the addition of NIPPV did not significantly improve the Chronic Respiratory Questionnaire compared to rehabilitation alone (mean difference in change between groups -1.3 points (95% CI: -9.7 to 7.4)), the addition of NIPPV did improve HRQoL assessed with the Maugeri Respiratory Failure questionnaire (-13.4% (-22.7 to -4.2; p = 0.005)), mood state (Hospital Anxiety and Depression scale -4.0 points (-7.8 to 0.0; p = 0.05)), dyspnea (Medical Research Council -0.4 points (-0.8 to -0.0; p = 0.05)), daytime arterial blood gases (PaCO2 -0.4 kPa (-0.8 to -0.2; p = 0.01); PaO2 0.8 kPa (0.0 to 1.5; p = 0.03)), 6-minute walking distance (77.3 m (46.4 to 108.0; p < 0.001)), Groningen Activity and Restriction scale (-3.8 points (-7.4 to -0.4; p = 0.03)), and forced expiratory volume in 1 second (115 ml (19 to 211; p = 0.019)). Exacerbation frequency was not changed.

Conclusions

The addition of NIPPV to pulmonary rehabilitation for 2 years in severe COPD patients with chronic hypercapnic respiratory failure improves HRQoL, mood, dyspnea, gas exchange, exercise tolerance and lung function decline. The benefits increase further with time.

Trial registration

ClinicalTrials.Gov (ID NCT00135538).  相似文献   

17.

Background

There is mounting evidence that estimates of intakes of a range of dietary nutrients are related to both lung function level and rate of decline, but far less evidence on the relation between lung function and objective measures of serum levels of individual nutrients. The aim of this study was to conduct a comprehensive examination of the independent associations of a wide range of serum markers of nutritional status with lung function, measured as the one-second forced expiratory volume (FEV1).

Methods

Using data from the Third National Health and Nutrition Examination Survey, a US population-based cross-sectional study, we investigated the relation between 21 serum markers of potentially relevant nutrients and FEV1, with adjustment for potential confounding factors. Systematic approaches were used to guide the analysis.

Results

In a mutually adjusted model, higher serum levels of antioxidant vitamins (vitamin A, beta-cryptoxanthin, vitamin C, vitamin E), selenium, normalized calcium, chloride, and iron were independently associated with higher levels of FEV1. Higher concentrations of potassium and sodium were associated with lower FEV1.

Conclusion

Maintaining higher serum concentrations of dietary antioxidant vitamins and selenium is potentially beneficial to lung health. In addition other novel associations found in this study merit further investigation.  相似文献   

18.

Background

NVA237 is a once-daily dry-powder formulation of the long-acting muscarinic antagonist glycopyrronium bromide in development for the treatment of chronic obstructive pulmonary disease (COPD). The glycopyrronium bromide in COPD airways clinical study 1 (GLOW1) evaluated the efficacy, safety and tolerability of NVA237 in patients with moderate-to-severe COPD.

Methods

Patients with COPD with a smoking history of ≥ 10 pack-years, post-bronchodilator forced expiratory volume in 1 second (FEV1) < 80% and ≥ 30% predicted normal and FEV1/forced vital capacity < 0.70 were enrolled. Patients were randomized to double-blind treatment with NVA237 50 μg once daily or placebo for 26 weeks with inhaled/intranasal corticosteroids or H1 antagonists permitted in patients stabilized on them prior to study entry. The primary outcome measure was trough FEV1 at Week 12.

Results

A total of 822 patients were randomized to NVA237 (n = 552) or placebo (n = 270). Least squares mean (± standard error) trough FEV1 at Week 12 was significantly higher in patients receiving NVA237 (1.408 ± 0.0105 L), versus placebo (1.301 ± 0.0137 L; treatment difference 108 ± 14.8 mL, p < 0.001). Significant improvements in trough FEV1 were apparent at the end of Day 1 and sustained through Week 26. FEV1 was significantly improved in the NVA237 group versus placebo throughout the 24-hour periods on Day 1 and at Weeks 12 and 26, and at all other visits and timepoints. Transition dyspnoea index focal scores and St. George''s Respiratory Questionnaire scores were significantly improved with NVA237 versus placebo at Week 26, with treatment differences of 1.04 (p < 0.001) and-2.81 (p = 0.004), respectively. NVA237 significantly reduced the risk of first moderate/severe COPD exacerbation by 31% (p = 0.023) and use of rescue medication by 0.46 puffs per day (p = 0.005), versus placebo. NVA237 was well tolerated and had an acceptable safety profile, with a low frequency of cardiac and typical antimuscarinic adverse effects.

Conclusions

Once-daily NVA237 was safe and well tolerated and provided rapid, sustained improvements in lung function, improvements in dyspnoea, and health-related quality of life, and reduced the risk of exacerbations and the use of rescue medication.

Trial registration

ClinicalTrials.gov: NCT01005901  相似文献   

19.

Background and Aim

In patients with cystic fibrosis (CF) the architecture of the developing lungs and the ventilation of lung units are progressively affected, influencing intrapulmonary gas mixing and gas exchange. We examined the long-term course of blood gas measurements in relation to characteristics of lung function and the influence of different CFTR genotype upon this process.

Methods

Serial annual measurements of PaO2 and PaCO2 assessed in relation to lung function, providing functional residual capacity (FRCpleth), lung clearance index (LCI), trapped gas (VTG), airway resistance (sReff), and forced expiratory indices (FEV1, FEF50), were collected in 178 children (88 males; 90 females) with CF, over an age range of 5 to 18 years. Linear mixed model analysis and binary logistic regression analysis were used to define predominant lung function parameters influencing oxygenation and carbon dioxide elimination.

Results

PaO2 decreased linearly from age 5 to 18 years, and was mainly associated with FRCpleth, (p < 0.0001), FEV1 (p < 0.001), FEF50 (p < 0.002), and LCI (p < 0.002), indicating that oxygenation was associated with the degree of pulmonary hyperinflation, ventilation inhomogeneities and impeded airway function. PaCO2 showed a transitory phase of low PaCO2 values, mainly during the age range of 5 to 12 years. Both PaO2 and PaCO2 presented with different progression slopes within specific CFTR genotypes.

Conclusion

In the long-term evaluation of gas exchange characteristics, an association with different lung function patterns was found and was closely related to specific genotypes. Early examination of blood gases may reveal hypocarbia, presumably reflecting compensatory mechanisms to improve oxygenation.  相似文献   

20.

Background

Systemic inflammation is associated with reduced lung function in both healthy individuals and those with chronic obstructive pulmonary disease (COPD). Whether systemic inflammation in healthy young adults is associated with future impairment in lung health is uncertain.

Methodology/Principal Findings

We evaluated the association between plasma fibrinogen and C-reactive protein (CRP) in young adults and lung function in the Coronary Artery Risk Development in Young Adults cohort study. Higher year 7 fibrinogen was associated with greater loss of forced vital capacity (FVC) between years 5 and 20 (439 mL in quartile 4 vs. 398 mL in quartile 1, P<0.001) and forced expiratory volume in 1 second (FEV1) (487 mL in quartile 4 vs. 446 mL in quartile 1, P<0.001) independent of cigarette smoking, body habitus, baseline lung function and demographic factors. Higher year 7 CRP was also associated with both greater loss of FVC (455 mL in quartile 4 vs. 390 mL in quartile 1, P<0.001) and FEV1 (491 mL in quartile 4 vs. 442 mL in quartile 1, P = 0.001). Higher year 7 fibrinogen and CRP were associated with abnormal FVC at year 20 (odds ratio (OR) per standard deviation 1.51 (95% confidence interval (CI): 1.30–1.75) for fibrinogen and 1.35 (95% CI: 1.14–1.59) for CRP). Higher year 5 fibrinogen was additionally associated with abnormal FEV1. A positive interaction was observed between pack-years cigarette smoking and year 7 CRP for the COPD endpoint, and among participants with greater than 10 pack-years of cigarette exposure, year 7 CRP was associated with greater odds of COPD at year 20 (OR per standard deviation 1.53 (95% CI: 1.08–2.16).

Conclusion/Significance

Systemic inflammation in young adults is associated with abnormal lung function in middle age. In particular, elevated CRP may identify vulnerability to COPD among individuals who smoke.

Trial Registration

ClinicalTrials.gov NCT00005130  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号