首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Work by previous investigators has indicated that a substantial amount of oxygen diffuses from the precapillary circulation. These losses imply that there should be radial gradients of oxygen tension (PO(2)) in arterioles, leading to a non-uniform distribution of oxygen within these microvessels. We have employed the phosphorescence quenching method to measure oxygen, allowing us to evaluate the heterogeneity of PO(2) inside short segments of microvessels. The phosphorescence decay curve contains information about the distribution of oxygen within the excited volume and the distribution can be represented as a histogram, by decomposing the decay curve into several components with weights proportional to the volume fraction of plasma with different PO(2), under the condition of a high signal-to-noise ratio. Furthermore, the histogram can be converted into a radial profile of PO(2), based on the assumptions of a circular vascular lumen, axisymmetric distribution of oxygen and monotonic PO(2) profile. Albumin-bound Pd-porphyrin phosphor was infused into the circulation of hamsters and excited by flash illumination at 10 Hz, with a square region of excitation light just covering the entire lumen, (i.e. width of region equaled luminal diameter) of microvessels in the hamster mesentery. A set of 50 curves (5 s of data) was averaged to obtain a decay curve with low noise. Curves were analyzed with the above histogram procedure, and this analysis allowed us to distinguish between PO(2) values originating from intra and extravascular subvolumes. The intravascular PO(2) in these microvessels was very heterogeneous, which could be explained by the existence of significant radial PO(2) gradients. The radial PO(2) gradients were estimated to be approximately 1 mmHg/microm.  相似文献   

2.
A new method for analysis of phosphorescence lifetime distributions in heterogeneous systems has been developed. This method is based on decomposition of the data vector to a linearly independent set of exponentials and uses quadratic programming principles for x2 minimization. Solution of the resulting algorithm requires a finite number of calculations (it is not iterative) and is computationally fast and robust. The algorithm has been tested on various simulated decays and for analysis of phosphorescence measurements of experimental systems with descrete distributions of lifetimes. Critical analysis of the effect of signal-to-noise on the resolving capability of the algorithm is presented. This technique is recommended for resolution of the distributions of quencher concentration in heterogeneous samples, of which oxygen distributions in tissue is an important example. Phosphors of practical importance for biological oxygen measurements: Pd-meso-tetra (4-carboxyphenyl) porphyrin (PdTCPP) and Pd-meso-porphyrin (PdMP) have been used to provide experimental test of the algorithm.  相似文献   

3.
The analysis of the fluorescence decay using discrete exponential components assumes that a small number of species is present. In the absence of a definite kinetic model or when a large number of species is present, the exponential analysis underestimates the uncertainty of the recovered lifetime values. A different approach to determine the lifetime of a population of molecules is the use of probability density functions and lifetime distributions. Fluorescence decay data from continuous distributions of exponentially decaying components were generated. Different magnitudes of error were added to the data to simulate experimental conditions. The resolvability of the distributional model was studied by fitting the simulated data to one and two exponentials. The maximum width of symmetric distributions (uniform, gaussian, and lorentzian), which cannot be distinguished from single and double exponential fits for statistical errors of 1 and 0.1%, were determined. The width limits are determined by the statistical error of the data. It is also shown that, in the frequency domain, the discrete exponential analysis does not uniformly weights all the components of a distribution. This systematic error is less important when probability and distribution functions are used to recover the decay. Finally, it is shown that real lifetime distributions can be proved using multimodal probability density functions. In the companion paper that follows we propose a physical approach, which provides lifetime distribution functions for the tryptophan decay in proteins. In the third companion paper (Alcala, J.R., E. Gratton, and F.J. Prendergast, 1987, Biophys. J., in press) we use the distribution functions obtained to fit data from the fluorescence decay of single tryptophan proteins.  相似文献   

4.
This study describes the use of two-photon excitation phosphorescence lifetime measurements for quantitative oxygen determination in vivo. Doubling the excitation wavelength of Pd-porphyrin from visible light to the infrared allows for deeper tissue penetration and a more precise and confined selection of the excitation volume due to the nonlinear two-photon effect. By using a focused laser beam from a 1,064-nm Q-switched laser, providing 10-ns pulses of 10 mJ, albumin-bound Pd-porphyrin was effectively excited and oxygen-dependent decay of phosphorescence was observed. In vitro calibration of phosphorescence lifetime vs. oxygen tension was performed. The obtained calibration constants were kq = 356 Torr(-1) x s(-1) (quenching constant) and tau0 = 550 micros (lifetime at zero-oxygen conditions) at 37 degrees C. The phosphorescence intensity showed a squared dependency to the excitation intensity, typical for two-photon excitation. In vivo demonstration of two-photon excitation phosphorescence lifetime measurements is shown by step-wise PO2 measurements through the cortex of rat kidney. It is concluded that quantitative oxygen measurements can be made, both in vitro and in vivo, using two-photon excitation oxygen-dependent quenching of phosphorescence. The use of two-photon excitation has the potential to lead to new applications of the phosphorescence lifetime technique, e.g., noninvasive oxygen scanning in tissue at high spatial resolution. To our knowledge, this is the first report in which two-photon excitation is used in the setting of oxygen-dependent quenching of phosphorescence lifetime measurements.  相似文献   

5.
The reflection coefficient (sigma) and permeability (P) of urea and ethylene glycol were determined by fitting the equations of Kedem and Katchalsky (1958) to the change in light scattering produced by adding a permeable solute to a red cell suspension. The measurements incorporated three important modifications: (a) the injection artifact was eliminated by using echinocyte cells; (b) the use of an additional adjustable parameter (Km), the effective dissociation constant at the inner side of the membrane; (c) the light scattering is not directly proportional to cell volume (as is usually assumed) because refractive index and scattering properties of the cell depend on the intracellular permeable solute concentration. This necessitates calibrating for known changes in refractive index (by the addition of dextran) and cell volume (by varying the NaCl concentration). The best fit was for sigma = 0.95, Po = 8.3 X 10(-4) cm/s, and Km = 100 mM for urea and sigma = 1.0, Po = 3.9 X 10(-4) cm/s, and Km = 30 mM for ethylene glycol. The effects of the inhibitors copper, phloretin, p- chloromercuriphenylsulfonate, and 5,5'-dithiobis (2-nitro) benzoic acid on the urea, ethylene glycol, and water permeability were determined. The results suggest that there are three separate, independent transport systems: one for water, one for urea and related compounds, and one for ethylene glycol and glycerol.  相似文献   

6.
The single room temperature phosphorescent (RTP) residue of horse liver alcohol dehydrogenase (LADH). Trp-314, and of alkaline phosphatase (AP), Trp-109, show nonexponential phosphorescence decays when the data are collected to a high degree of precision. Using the maximum entropy method (MEM) for the analysis of these decays, it is shown that AP phosphorescence decay is dominated by a single Gaussian distribution, whereas for LADH the data reveal two amplitude packets. The lifetime-normalized width of the MEM distribution for both proteins is larger than that obtained for model monoexponential chromophores (e.g., terbium in water and pyrene in cyclohexane). Experiments show that the nonexponential decay is fundamental; i.e., an intrinsic property of the pure protein. Because phosphorescence reports on the state of the emitting chromophore, such nonexponential behavior could be caused by the presence of excited state reactions. However, it is also well known that the phosphorescence lifetime of a tryptophan residue is strongly dependent on the local flexibility around the indole moiety. Hence, the nonexponential phosphorescence decay may also be caused by the presence of at least two states of different local rigidity (in the vicinity of the phosphorescing tryptophan) corresponding to different ground state conformers. The observation that in the chemically homogeneous LADH sample the phosphorescence decay kinetics depends on the excitation wavelength further supports this latter interpretation. This dependence is caused by the wavelength-selective excitation of Trp-314 in a subensemble of LADH molecules with differing hydrophobic and rigid environments. With this interpretation, the data show that interconversion of these states occurs on a time scale long compared with the phosphorescence decay (0.1-1.0 s). Further experiments reveal that with increasing temperature the distributed phosphorescence decay rates for both AP and LADH broaden, thus indicating that either 1) the number of conformational states populated at higher temperature increases or 2) the temperature differentially affects individual conformer states. The nature of the observed heterogeneous triplet state kinetics and their relationship to aspects of protein dynamics are discussed.  相似文献   

7.
Time-resolved F?rster resonance energy transfer (trFRET) has been used to obtain interdye distance distributions. These distributions give the most probable distance as well as a parameter, sigma, that characterize the width of the distribution. This latter parameter contains information not only on the flexibility of the dyes tethered to macromolecules, but on the flexibility of the macromolecules. Both the most probable interdye distance as well as sigma provide insight into DNA static bending and DNA flexibility. Time-resolved fluorescence anisotropy and static anisotropy measurements can be combined to provide a measure of the cone angle within which the tethered dyes appear to wobble. When this motion is an order of magnitude faster than the average lifetime that characterizes transfer, an average value of the dipolar orientational parameter kappa2 can be calculated for various mutual dye orientations. The resulting kappa2 distribution is very much narrower than the limiting values of 0 and 4, allowing more precise distances and distance changes to be determined. Static and time-resolved fluorescence data can be combined to constrain the analyses of DNA-protein kinetics to provide thermodynamic parameters for binding and for conformational changes along a reaction coordinate. The parameter sigma can be used to model multiple DNA-protein complexes with varying DNA bend angles in a global fitting of trFRET data. Such a global fitting approach has shown how the range of bends in single base DNA variants, when bound by the TATA binding protein (TBP), can be understood in terms of two limiting forms. Time-resolved FRET, combined with steady-state FRET, can be used to show not only how osmolytes affect the binding of DNA to proteins, but also how DNA bending depends on osmolyte concentration in the DNA-protein complexes.  相似文献   

8.
双指数模型在高b值弥散加权成像中的初步研究   总被引:1,自引:0,他引:1  
目的采用双指数分析模型探讨弥散加权信号强度的衰减规律,揭示脑组织的弥散信息。材料和方法对豆状核、内囊、额叶自质、丘脑等感兴趣区的每一像素,使用Matlab优化工具箱中的lsqcurvefit()函数对b值从500s/mm。到3500s/mm。共计7个b值图像的信号强度值进行拟合,并与单指数拟合的结果进行比较。结果双指数模型对信号强度的拟合优于单指数模型,并能获得三个新参数。结论双指数模型能更好的拟合高b值时图像信号强度.所得的三个参数能从不同角度提供大脑的弥散信息.但其生理基础有待于进一步研究。  相似文献   

9.
A Building Block Model for Quantitative Genetics   总被引:2,自引:2,他引:0       下载免费PDF全文
H. Tachida  C. C. Cockerham 《Genetics》1989,121(4):839-844
We introduce a quantitative genetic model for multiple alleles which permits the parameterization of the degree, D, of dominance of favorable or unfavorable alleles. We assume gene effects to be random from some distribution and independent of the D's. We then fit the usual least-squares population genetic model of additive and dominance effects in an infinite equilibrium population to determine the five genetic components--additive variance sigma 2 a, dominance variance sigma 2 d, variance of homozygous dominance effects d2, covariance of additive and homozygous dominance effects d1, and the square of the inbreeding depression h--required to treat finite populations and large populations that have been through a bottleneck or in which there is inbreeding. The effects of dominance can be summarized as functions of the average, D, and the variance, sigma 2 D. An important distinction arises between symmetrical and nonsymmetrical distributions of gene effects. With symmetrical distributions d1 = -d2/2 which is always negative, and the contribution of dominance to sigma 2 a is equal to d2/2. With nonsymmetrical distributions there is an additional contribution H to sigma 2 a and -H/2 to d1, the sign of H being determined by D and the skew of the distribution. Some numerical evaluations are presented for the normal and exponential distributions of gene effects, illustrating the effects of the number of alleles and of the variation in allelic frequencies. Random additive by additive (a*a) epistatic effects contribute to sigma 2 a and to the a*a variance, sigma 2/aa, the relative contributions depending on the number of alleles and the variation in allelic frequencies.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Fluorescence correlation spectroscopy (FCS) is a sensitive and widely used technique for measuring diffusion. FCS data are conventionally modeled with a finite number of diffusing components and fit with a least-square fitting algorithm. This approach is inadequate for analyzing data obtained from highly heterogeneous systems. We introduce a Maximum Entropy Method based fitting routine (MEMFCS) that analyzes FCS data in terms of a quasicontinuous distribution of diffusing components, and also guarantees a maximally wide distribution that is consistent with the data. We verify that for a homogeneous specimen (green fluorescent protein in dilute aqueous solution), both MEMFCS and conventional fitting yield similar results. Further, we incorporate an appropriate goodness of fit criterion in MEMFCS. We show that for errors estimated from a large number of repeated measurements, the reduced chi(2) value in MEMFCS analysis does approach unity. We find that the theoretical prediction for errors in FCS experiments overestimates the actual error, but can be empirically modified to serve as a guide for estimating the goodness of the fit where reliable error estimates are unavailable. Finally, we compare the performance of MEMFCS with that of a conventional fitting routine for analyzing simulated data describing a highly heterogeneous distribution containing 41 diffusing species. Both methods fit the data well. However, the conventional fit fails to reproduce the essential features of the input distribution, whereas MEMFCS yields a distribution close to the actual input.  相似文献   

11.
Traditionally, enzyme populations have been treated as if they were either homogenous, or heterogeneous with distinct and separable subpopulations. The microheterogeneity model, however, assumes that there is a continuous distribution of properties in the population. In the area of enzyme deactivation kinetics, this model describes the heterogeneous population as having a continuous distribution of activation energy of deactivation. This distribution is characterized by mean activation energy, and a standard deviation of activation energy. The microheterogeneity model contains two parameters, (0) and sigma. Parameter (0) is the mean value of for a heterogeneous enzyme population; is the activation energy divided by absolute temperature and the ideal gas constant. Parameter sigma is the standard deviation of the Gaussian distribution of values in the population. If the population is homogeneous, then = (0) for all enzyme molecules and sigma = 0. There are certain ratios which are independent of (0) and dependent upon sigma. Two important ratios are t(1/4)/t(1/2) and t(1/2)/t(1/2) ('), where t(1/2) (') represents t(1/2) for a homogeneous enzyme population with the same mean ((0)), as the heterogeneous population. If there is experimental deactivation data for the heterogeneous population which is well behaved, the first ratio, t(1/4)/t(1/2), can be determined by estimating the time in minutes at which the enzyme has lost 25% of its activity (t(1/4)), and the time in minutes at which the enzyme has lost 50% of its activity (t(1/2)), and then taking the ratio t(1/4)/t(1/2). The corresponding value of sigma can be estimated from a graph. The ratio t(1/2)/t(1/2) (') can be found directly as a function of t(1/4)/t(1/2), and can be estimated from another graph. The value of (0) can then be calculated from the formulasgiven in the article.  相似文献   

12.
D Amir  E Haas 《Biochemistry》1987,26(8):2162-2175
A series of four bovine pancreatic trypsin inhibitor (BPTI) derivatives, site specifically labeled by (2-methoxy-1-naphthyl)methyl (MNA) at the N-terminal amino group and by [7-(dimethylamino)-coumarin-4-yl]acetyl (DA-coum) at one of the four epsilon-amino groups, was prepared. The four derivatives, N alpha-MNA-Arg1-N epsilon-DA-coum-Lysn-BPTI [(1-n)BPTI] (n = 15, 26, 41, and 46), were purified by affinity chromatography and high-performance liquid chromatography (HPLC). The homogeneity of each derivative and its site of labeling were characterized by HPLC tryptic peptide mapping. Nonradiative energy transfer from MNA (donor) to DA-coum (acceptor) was measured by monitoring donor emission and acceptor excitation spectra. Transfer efficiencies between 45% and 85% were observed. The fluorescence decay of MNA in MNA-BPTI, a derivative labeled by a donor without an acceptor, is monoexponential, with a lifetime of 6.8 +/- 0.15 ns. The decay kinetics of MNA fluorescence measured for derivatives labeled both by donor and acceptor showed a small deviation from monoexponential decay with shorter average lifetimes. Analysis of the experimental decay curves yielded the detailed intramolecular distance distribution functions for each pair of labeled sites. The averages of the calculated distance distribution functions are close to the values expected from the known structure of BPTI in the crystalline state. The derivatives thus obtained are suitable for investigation of conformational transitions of the labeled protein and for monitoring localized changes such as those involved in the folding or unfolding transitions.  相似文献   

13.
To clarify the transport of O(2) across the microvessels in skeletal muscle, we designed an intravital laser microscope that utilizes a phosphorescence quenching technique to determine both the microvascular and tissue PO(2). After we injected the phosphorescent probe into systemic blood, phosphorescence excited by a N(2)-dye pulse laser was detected with a photomultiplier over a 10 microm in diameter area. In vitro and in vivo calibrations confirmed that the present method is accurate for PO(2) measurements in the range of 7-90 Torr (r = 0.958) and has a rapid response time. This method was then used to measure the PO(2) of microvessels with different diameters (40-130 microm) and of interstitial spaces in rat cremaster muscle. These measurements showed a significant drop in PO(2) in the arterioles after branching (from 74.6 to 46.6 Torr) and the presence of a large PO(2) gradient at the blood-tissue interface of arterioles (15-20 Torr). These findings suggest that capillaries are not the sole source of oxygen supply to surrounding tissue.  相似文献   

14.
In this study we compare oxygen tension (PO2) histograms measured with O2 microelectrodes and a new optical PO2 measurement device, the OxyLite, in normal tissues (mouse spleen and thymus) and in tumors (R3230Ac in rats) (n = 5-6). The transient response to glucose infusion or 100% O2 breathing (hyperoxia) was also measured in tumors. PO2 histograms of spleen and thymus with the two devices were not different. The OxyLite tumor PO2 histogram, however, was left-shifted compared with the microelectrode (median PO2 1.0 vs. 4.0 mmHg, P = 0.016). Both probes responded to acute hyperglycemia with a mean increase of 3-6 mmHg, but the microelectrode change was not significant. The OxyLite consistently recorded large PO2 increases (approximately 28 mmHg) with hyperoxia, whereas the microelectrode response was variable. The OxyLite averages PO2 over an area that contains interstitial and vascular components, whereas the microelectrode measures a more local PO2. This study demonstrates the importance of considering the features of the measurement device when studying tissues with heterogeneous PO2 distributions (e.g., tumors).  相似文献   

15.
The conceptual design and development of a long-term, low-profile intracorporeal left ventricular assist device is a multifaceted project involving a series of technical, anatomic and physiologic considerations. Patients with severe left ventricular failure refractory to all other forms of therapy could benefit from such a device. Prior to fabrication of such a blood pump, consideration must be given to physiologic parameters of the projected patient population. The pump must be designed to meet physiologic demands and yet conform to the anatomic constraints posed by the patient population. We measured the body surface area (BSA) of a group of patients (n=50) and found the mean BSA for this group to be 1.804 +/- 0.161 m(2). Using 25 ml/m(2) as a stroke volume index indicative of left ventricular failure and a stroke volume index of 45 ml/m(2) as normal, distributions of stroke volumes (normal and in left ventricular failure) were plotted for a potential population and demonstrated that 63% of the projected population can be returned to normal by a pump with a stroke volume >/= 83 ml. Cadaver fitting studies established that 73% of the potential population can accommodate an ALVAD 10.8 cm in diameter. In-vitro tests demonstrated that a pump stroke volume >/= 83 ml could be achieved by the proposed pump with a 15 mmHg filling pressure at rates up to 125 B/min. A pusher-plate stroke of 0.56 inches would be necessary to provide a stroke volume >/= 83 ml. The percent of the patient population that could be served was determined by excluding those in whom the pump would not fit or in whom it would provide less than a normal resting stroke volume. Approximately 73% of the projected patient population would accommodate this pump and be returned to normal circulatory dynamics.  相似文献   

16.
Measurements of homogeneous and heterogeneous fluorescence intensity decays using a hybrid time-correlated single photon counting/multifrequency phase fluorometer are reported. A trio of fluorophores exhibiting a range of decay profiles was selected. p-Terphenyl, 1,4-bis[2-(4-methyl-5-phenyloxazolyl)]benzene [(Me)2POPOP], and p-bis[2-(5-phenyloxazolyl)]benzene (POPOP), commonly used reference fluorophores, were analyzed initially; their emissions were characterized by monoexponential decay functions. Additionally, emissions from two single tryptophan proteins with different decay profiles were measured. Scorpion neurotoxin variant 3 required three exponentials to fit the emission decay properly (average lifetime approximately 500 ps). At pH 5.5, the fluorescence emission of ribonuclease T1 showed a monoexponential decay with a measured lifetime of approximately 4.0 ns. Thus, in each case, the results from both measurements were consistent between the two detection systems, confirming the view that the two approaches for measuring fluorescence lifetimes are equivalent.  相似文献   

17.
This study presents a generic numerical model to simulate the coupled solute and solvent transport in human ovarian tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA). The model accounts for the axial and radial diffusion of the solute (CPA) as well as axial convection of the CPA, and a variable vascular surface area (A) during the transport process. In addition, the model also accounts for the radial movement of the solvent (water) into and out of the vascular spaces. Osmotic responses of various cells within an human ovarian tissue section are predicted by the numerical model with three model parameters: permeability of the tissue cell membrane to water (L(p)), permeability of the tissue cell membrane to the solute or CPA (omega) and the diffusion coefficient of the solute or CPA in the vascular space (D). By fitting the model results with published experimental data on solute/water concentrations within an human ovarian tissue section, I was able to determine the permeability parameters of ovarian tissue cells in the presence of 1.5M solutions of each of the following: dimethyl sulphoxide (DMSO), propylene glycol (PROH), ethylene glycol (EG), and glycerol (GLY), at two temperatures (4 degrees C and 27 degrees C). Modeling Approach 1: Assuming a constant value of solute diffusivity (D = 1.0 x 10(-9) m(2)/sec), the best fit values of L(p) ranged from 0.35 x 10(-14) to 1.43 x 10(-14) m(3)/N-sec while omega ranged from 2.57 x 10(-14) to 70.5 x 10(-14) mol/N-sec. Based on these values of L(p) and omega, the solute reflection coefficient, sigma defined as sigma = 1-omega v(CPA)/L(P) ranged from 0.9961 to 0.9996. Modeling Approach 2: The relative values of omega and sigma from our initial modeling suggest that the embedded ovarian tissue cells are relatively impermeable to all the CPAs investigated (or omega approximately 0 and sigma approximately 1.0). Consequently the model was modified and used to predict the values of L(p) and D assuming omega = 0 and sigma = 1.0. The best fit values of L(p) ranged from 0.44 x 10(-14) to 1.2 x 10(-14) m(3)/N-sec while D ranged from 0.85 x 10(-9) to 2.08 x 10(-9) m(2)/sec. Modeling Approach 3: Finally, the best fit values of D from modeling approach 2 were incorporated into model 1 to re-predict the values of L(p) and omega. It is hoped that the ovarian tissue cell parameters reported here will help to optimize chemical loading and unloading procedures for whole ovarian tissue sections and consequently, tissue cryopreservation procedures.  相似文献   

18.
We have previously proposed the osmofiltration method based on a modified Hanss hemorheometer to analyze distributions of erythrocytes in their ability to pass through membrane filters with 3 microns pores. Upon decrease in medium osmolality (u) the erythrocyte volume increases. When cell volume becomes V = Vcr at u = ucr, such cell loses its ability to pass through a 3 microns pore. The flow rate of erythrocyte suspension containing cells with different ucr through a filter gradually decreases with decreasing medium osmolality. This rate becomes zero at some u = omega, when the number of non-filterable cells in the applied sample approaches the number of pores in filter. Experimental determination of the dependencies of the filtration rate on medium osmolality for various hematocrit values allows to obtain omega for each hematocrit and, thereby, to assess the distribution of erythrocytes in ucr. Here, we propose a simplified version of this method, which allows screening of the erythrocytes in heterogeneous suspensions for the distribution in ucr by measuring omega for only two hematocrit values, 0.1% and 1%. Applications of the proposed method are exemplified by analysing the erythrocyte populations of healthy donors, of patients with microspherocytosis, hemochromatosis and normal erythrocyte populations in an acidic environment.  相似文献   

19.
Abstract. The growth in volume of human peripheral blood lymphocytes after stimulation with various concentrations of PHA was measured with an electronic particle counter. The percentage of growing cells and averaged values describing their growth rates during the elapsed period of culture were estimated by fitting to the observed data the volume distributions derived from a mathematical model. With sub-optimal doses, the percentage of cells stimulated, and their incremental growth rate, increased with increasing dose of PHA, but the time-course of recruitment into the G1-phase was similar with all PHA concentrations studied. The results provide strong support for the 'trigger' hypothesis that there is a distribution of stimulation thresholds within the lymphocyte population: consequently, increasing mitogen concentration will be expected to result in increased numbers of responding cells within the suboptimal concentration range.  相似文献   

20.
There are large differences in the frequencies of different kinds of neoplasms in a human or animal population. The question arises, whether the set of these frequencies shows some characteristic feature. Our fitting results on neoplasm frequency data relating to laboratory rats show that the frequencies are approximately lognormally distributed. At the same time, fitting results with the logarithmic series distribution, also frequently used in similar studies, are poor. A good fit of the Zipf-Mandelbrot distribution, fitted to the descendingly ordered dominant and subdominant frequencies can be achieved, sometimes after omitting some diagnoses. We point out the possibility that the omitted frequencies may be considered "unnatural" ones. The good fit of a particular frequency distribution to the diagnosis frequency set suggests a corresponding chance mechanism in forming the occurrence probabilities of different kinds of neoplasms. A frequently used scalar feature of frequency distributions of categorical data is the concentration or diversity. It was found that in the female rat population the diagnoses are more concentrated among the diagnosis categories. A possible explanation may involve the fact that females mature faster than males. The study of the distribution properties of the diagnosis frequencies promises the observation of new epidemiological phenomena.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号