首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid method is described that uses the tetrazolium salt 2-( p -iodophenyl-3-( p -nitrophenyl)-5-phenyl tetrazolium chloride (INT) to stain viable micro-organisms retained on a filter membrane. Good correlation exists between numbers of INT stained cells and aerobic plate counts of single strain cultures of bacteria and yeasts. A pre-treatment step allows the technique to be used for pasteurized milk.  相似文献   

2.
The growth patterns of microcolonies of 59 different pure cultures were studied on eight selective solid media. A method of growing microcolonies on the surface of polycarbonate membrane filters, placed on the selective agar media, followed by staining and examination by epifluorescent microscopy was developed. The patterns of growth of the pure cultures as microcolonies were studied on the eight selective media. Only four media proved to be reliable for this purpose and the relationship between the microcolony count and plate count was studied on these media together with nutrient agar. Microcolony counts using three of these media (enriched lauryl sulphate aniline blue, pseudomonas selective agar (C-F-C) and Baird-Parker medium) were capable of giving reliable estimates of coliforms (r = 0.89), pseudomonads (r = 0.93) and staphylococci (r = 0.92) after incubation at 30 degrees C for 3 or 6 h (staphylococci) at contamination levels of above 10(3) bacteria/g in a variety of foods. The results are available within a working day and should allow the more efficient management of food supplies.  相似文献   

3.
The growth patterns of macrocolonies of 59 different pure cultures were studied on eight selective solid media. A method of growing microcolonies on the surface of polycarbonate membrane filters, placed on the selective agar media, followed by staining and examination by epifluorescent microscopy was developed. The patterns of growth of the pure cultures as microcolonies were studied on the eight selective media. Only four media proved to be reliable for this purpose and the relationship between the microcolony count and plate count was studied on these media together with nutrient agar. Microcolony counts using three of these media (enriched lauryl sulphate aniline blue, pseudomonas selective agar (C-F-C) and Baird-Parker medium) were capable of giving reliable estimates of coliforms (r = 0·89), pseudomonads (r = 0·93) and staphylococci (r = 0·92) after incubation at 30°C for 3 or 6 h (staphylococci) at contamination levels of above 103 bacteria/g in a variety of foods. The results are available within a working day and should allow the more efficient management of food supplies.  相似文献   

4.
AIMS: A method for rapid and simultaneous detection, identification and enumeration of specific micro-organisms using Peptide Nucleic Acid (PNA) probes is presented. METHODS AND RESULTS: The method is based on a membrane filtration technique. The membrane filter was incubated for a short period of time. The microcolonies were analysed by in situ hybridization, using peroxidase-labelled PNA probes targeting a species-specific rRNA sequence, and visualized by a chemiluminescent reaction. Microcolonies were observed as small spots of light on film, thereby providing simultaneous detection, identification and enumeration. The method showed 95-100% correlation to standard plate counts along with definitive identification due to the specificity of the probe. CONCLUSION: Using the same protocol, results were generated approximately three times faster than culture methods for Gram-positive and -negative bacterial species and yeast species. SIGNIFICANCE AND IMPACT OF THE STUDY: The method is an improvement on the current membrane filtration technique, providing rapid determination of the level of specific pathogens, spoilage or indicator micro-organisms.  相似文献   

5.
A preliminary evaluation of an automated direct epifluorescent filter technique instrument, COBRA, showed that it enumerated rapidly bacteria in cultures, raw milk, meat and fish. The correlation coefficients of regression lines with corresponding pour plate counts were 0·99 (pure cultures), 0·81 (raw milk) and 0·91 (raw meat and fish), respectively. The system was simple to use, one operator could process > 100 samples/h and results were available in < 1 h.  相似文献   

6.
7.
A rapid, simple and inexpensive method has been devised to determine the proportion of colonies of ureolytic organisms in cultures of complex microbial populations. Spiral plated cultures displaying well separated colonies are tested for ureolytic micro-organisms by imprinting the colonies onto filter papers impregnated with a solution of 1 mol/l urea and phenol red (0·1% w/v) in 0·1 mol/l phosphate buffer (pH 6·8). A rapid colour change indicates ureolytic activity. The proportion of ureolytic colony-forming units in cultures of saliva specimens from 90 school children ranged from less than 1% to 40% (mean 9·9%± 7·7). Saliva and dental plaque specimens from 16 adult subjects were also tested and the occurrence of urease-positive organisms was substantially less in plaque (3·6%± 3·7, range 0·1–12) than saliva (18·7%± 13·8, range 1·3–51). The predominant ureolytic oral species was Streptococcus salivarius , 75 (54·7%) of 137 tested isolates being urease-positive.  相似文献   

8.
A carrier-mediated counter transport process is proposed to separate and to purify an amino acid produced by microbial fermentation. The case of L-valine permeation through a liquid membrane, constituted by a solution of Aliquat 336 in decanol and supported by a hydrophobic microporous membrane, is reported. A mathematical model was developed to estimate distribution coefficients and permeabilities and to predict the influence of hydrodynamic and pH conditions on supported liquid membrane (SLM) performances. Optimum conditions for the transport and the concentration of valine were achieved with synthetic aqueous valine solutions. Series of experiments on fermentation broths, where molasses and biomass contents were varied, permitted pointing out the role of the broth composition on the kinetics and yields of separation. The selectivity of transport of valine by an Aliquat 336/decanol liquid membrane was about 10 toward molasses dyes, 100 toward glucose, and beyond 1000 toward sucrose. This allowed us to achieve the recovery and one step of purification of the product in a single operation. The stability of the Aliquat 336/decanol liquid membrane was sufficient to ensure a selective transport of valine during a continuous run lasting 18 days.  相似文献   

9.
The highest purity ratio of phycocyanin extract was obtained when fresh biomass was used as raw material. The crude extract was purified by membrane process using microfiltration and ultrafiltration. Membrane of pore sizes 5 μm, at feed flow rate of 150 mL min−1, permeate flux of 58.5 L h−1 m−2 was selected for coarse filtration and membrane with pore size 0.8/0.2 μm at the flow rate of 100 mL min−1, permeate flux of 336 L h−1 m−2 was selected for fine filtration, giving phycocyanin recovery of 88.6% and 82.9%, respectively. For ultrafiltration, membrane with MWCO at 50 kDa, 69 kPa and 75 mL min−1 of flow rate with a mean permeate flux 26.8 L h−1 m−2 and a retention rate of 99% was found to be optimal. Under these filtration conditions, food grade phycocyanin with the purity around 1.0 containing c-phycocyanin as the major component was obtained.  相似文献   

10.
11.
Zhang T  Wang RY  Bao QY  Rawson DM 《Theriogenology》2006,66(4):982-988
Information on fish embryo membrane permeability is vital in their cryopreservation. Whilst conventional volumetric measurement based assessment methods have been widely used in fish embryo membrane permeability studies, they are lengthy and reduce the capacity for multi-embryo measurement during an experimental run. A new rapid 'real-time' measurement technique is required to determine membrane permeability during cryoprotectant treatment. In this study, zebrafish (Danio rerio) embryo membrane permeability to cryoprotectants was investigated using impedance spectroscopy. An embryo holding cell, capable of holding up to 10 zebrafish embryos was built incorporating the original system electrods for measuring the impedance spectra. The holding cell was tested with deionised water and a series of KCl solutions with known conductance values to confirm the performance of the modified system. Untreated intact embryos were then tested to optimise the loading capacity and sensitivity of the system. To study the impedance changes of zebrafish embryos during cryoprotectant exposure, three, six or nine embryos at 50% epiboly stage were loaded into the holding cell in egg water, which was then removed and replaced by 0.5, 1.0, 2.0 or 3M methanol or dimethyl sulfoxide (DMSO). The impedance changes of the loaded embryos in different cryoprotectant solutions were monitored over 30 min at 22 degrees C, immediately following embryo exposure to cryoprotectants, at the frequency range of 10-10(6)Hz. The impedance changes of the embryos in egg water were used as controls. Results from this study showed that the optimum embryo loading level was six embryos per cell for each experimental run. The optimum frequency was identified at 10(3.14) or 1,380 Hz which provided good sensitivity and reproducibility. Significant impedance changes were detected after embryos were exposed to different concentrations of cryoprotectants. The results agreed well with those obtained from conventional volumetric based studies.  相似文献   

12.
A rapid method based on bacterial adhesion was developed for the detection of Salmonella in an enriched meat system. Minced beef samples inoculated with Salm. enteritidis (10 cfu g-1) were incubated overnight (18 h) at 37 degrees C in buffered peptone water. Salmonella enteritidis cells were isolated from the enriched meat sample by surface adhesion onto a polycarbonate membrane attached to a glass slide. The organisms attached to this polycarbonate membrane were subsequently visualized using immunofluorescent microscopy. The technique had a detection level of log10 3.5 Salmonella ml-1. The surface adhesion immunofluorescent technique correlated well with Salmonella plate counts (r2 = 0.99). Application of the rapid method to retail beef and poultry samples (n = 100) confirmed the correlation between this technique and traditional microbiological procedures. Thirty-one retail samples were reported positive for Salmonella species. No false positives or negatives were recorded for the rapid method.  相似文献   

13.
The use of a novel surface adhesion technique to isolate Listeria monocytogenes and Listeria innocua from an enrichment meat system was developed. Minced beef samples inoculated with L. monocytogenes (10 cfu g(-1)) were incubated at 30 degrees C for 14-18 h in a suitable enrichment broth. Listeria monocytogenes cells were isolated from the enriched meat sample by surface adhesion onto a polycarbonate membrane which was attached to a glass microscope slide. The Listeria cells on the membrane were subsequently visualized using an immunofluorescent microscopy procedure. The antibody used in this technique reacts with L. monocytogenes and L. innocua. The technique was demonstrated to have a detection level of log10 3.11 cfu ml(-1). There was excellent correlation (r2 = 0.98) between the counts obtained by this surface adhesion immunofluorescent (SAIF) technique and counts obtained using traditional methods, i.e. plate counts on PALCAM. When the regression equation relating the rapid and standard methods was validated using the data from 50 retail beef mince samples, an rsd value of +/- 0.25 was obtained. No false-negative or false-positive results were recorded for L. monocytogenes or L. innocua species using the SAIF technique.  相似文献   

14.
A modified mPA medium, designated mPA-C, was shown to recover Pseudomonas aeruginosa from a variety of water sources with results comparable to those with mPA-B and within the confidence limits of a most-probable-number technique. Enumeration of P. aeruginosa on mPA-C was possible after only 24 h of incubation at 41.5 degrees C, compared with 72 h of incubation required for mPA-B and 96 h of incubation for a presumptive most probable number.  相似文献   

15.
A modified mPA medium, designated mPA-C, was shown to recover Pseudomonas aeruginosa from a variety of water sources with results comparable to those with mPA-B and within the confidence limits of a most-probable-number technique. Enumeration of P. aeruginosa on mPA-C was possible after only 24 h of incubation at 41.5 degrees C, compared with 72 h of incubation required for mPA-B and 96 h of incubation for a presumptive most probable number.  相似文献   

16.
Fecal coliforms growing in a selective lactose-based broth medium at 44.5 degrees C generate a change in the electrical impedance of the culture relative to a sterile control when populations reach 10(6) to 10(7) per ml. The ratio of these changes was measured automatically, and the data were processed by computer. A linear relation was found between the log10 of the number of fecal coliforms in an inoculum and the time required for an electrical impedance ratio signal to be detected. Pure culture inocula consisting of 100 fecal coliforms in log phase or stationary phase were detected in 6.5 and 7.7 h, respectively. Standard curves of log10 fecal coliforms in wastewater inocula versus detection time, based on samples collected at a sewage treatment plant over a 4-month period, were found to vary from one another with time. Nevertheless, detection times were rapid and ranged from 5.8 to 7.9 h for 200 fecal coliforms to 8.7 to 11.4 h for 1 fecal coliform. Variations in detection times for a given number of fecal coliforms were also found among sewage treatment plants. A strategy is proposed which takes these variations into account and allows for rapid, automated enumeration of fecal coliforms in wastewater by the electrical impedance ratio technique.  相似文献   

17.
Fecal coliforms growing in a selective lactose-based broth medium at 44.5 degrees C generate a change in the electrical impedance of the culture relative to a sterile control when populations reach 10(6) to 10(7) per ml. The ratio of these changes was measured automatically, and the data were processed by computer. A linear relation was found between the log10 of the number of fecal coliforms in an inoculum and the time required for an electrical impedance ratio signal to be detected. Pure culture inocula consisting of 100 fecal coliforms in log phase or stationary phase were detected in 6.5 and 7.7 h, respectively. Standard curves of log10 fecal coliforms in wastewater inocula versus detection time, based on samples collected at a sewage treatment plant over a 4-month period, were found to vary from one another with time. Nevertheless, detection times were rapid and ranged from 5.8 to 7.9 h for 200 fecal coliforms to 8.7 to 11.4 h for 1 fecal coliform. Variations in detection times for a given number of fecal coliforms were also found among sewage treatment plants. A strategy is proposed which takes these variations into account and allows for rapid, automated enumeration of fecal coliforms in wastewater by the electrical impedance ratio technique.  相似文献   

18.
The separation and concentration of L-phenylalanine (L-Phe) using a supported liquid membrane (SLM) is investigated. A cation complex agent, di-2-ethylhexyl phosphoric acid (D2EHPA), is used as a carrier in the SLM with n-Heptane as a solvent. The reaction order and equilibrium constant in the formation reaction of L-Phe-carrier complex are obtained from the extraction experment. A mathematical model for a carrier mediated counter transport process is proposed to estimate the diffusion coefficient of L-Phe-carrier complex in the liquid membrane. Permeation experiments of L-Phe using a SLM are performed under various operating conditions and optimum conditions for the transport of L-Phe are obtained. Concentration of L-Phe in the strip phase against its concentration is observed. Transport rate of glucose through liquid membrane is less than that of L-Phe in the competitive transport of L-Phe and glucose. And the existence of glucose reduced the transport rate of L-Phe. The performance of separation with continuous strip phase is increased due to the dilution effect in the strip phase.  相似文献   

19.
The membrane filter technique with AC agar medium supplemented with 0.04% NaN3 and 0.00015% 2,3,5-triphenyltetrazolium chloride for enumeration of enterococci in water is described. An appropriate volume of a water sample was filtered through the membrane filter. The membrane filter was put on an AC agar plate (designated as the AC.MF technique), which was incubated at 37 C for 18 hr and further at 45 C for 24 hr. By this AC.MF technique, all the colonies grown on the membrane filters were identified as enterococci, and the count of enterococci obtained by the AC.MF technique was similar to that by the AC.MPN technique. The AC.MF technique may be useful for accurate and rapid enumeration of enterococci in water and serve as a simple method for determining the sanitary quality of water.  相似文献   

20.
Processing tissue for transmission electron microscopy by standard laboratory methods can take two to three days. This makes the development of new techniques time consuming and generally restricts the use of the electron microscope in routine diagnostic work. The possibility of viewing tissue with the electron microscope five hours after sampling using rapid processing techniques is presented. The morphology of the tissue appears undamaged with cell and organelle ultrastructures being readily recognized, as is the presence of virus and its replicating stages. When combined with immunoelectron microscopy a rapid labeling protocol is possible. We have used the technique to develop protein A-gold (6 and 16 nm particles) and ferritin immunoelectron microscopic techniques to demonstrate viral antigens in brain cell cultures and brain tissue from mice infected with Semliki Forest virus.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号