首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Chen Z  Liu G  Chen M  Peng Y  Wu M 《Analytical biochemistry》2009,384(2):337-653
A new high-sensitivity detection of protein assay at the nanogram level is proposed based on the decreased resonance light scattering (RLS) signals of zwitterionic gemini surfactant (phosphodiesters quaternary ammonium salt [PQAS]). It was found that PQAS self-assembled into nanometer-scale PQAS aggregates, which induced intense RLS signal in Britton-Robinson (BR) buffer solution (pH 10.5). Under the optimum conditions, the RLS intensity quenching extent of PQAS aggregation was in proportion to the concentration of proteins in the range of 0.0012-1.08 μg/ml for bovine serum albumin, 0.0015-0.95 μg/ml for human serum albumin, and 0.0025-1.3 μg/ml for γ-globulin. The detection limits were 0.8, 1.2, and 2.0 ng/ml, respectively. The proposed method was successfully applied to determine total protein in human serum samples, and the results were identical to those obtained by the Bradford assay. The mechanism of interaction between PQAS and protein was studied using RLS, fluorescence, and time-resolved fluorescence, which indicated that the new complex formed between them, disaggregating self-aggregation of PQAS, resulted in the dominated quenching of RLS signal of the assay system.  相似文献   

2.
3.
A competitive aptamer bioassay was developed for the selective detection of adenosine triphosphate (ATP). The proposed bioassay employed the T-Hg-T induced hairpin-structure as the molecule conformational switch (MCS), aptamer as a specific recognizer, and mercaptoundecanoic acid modified gold nanoclusters (MUA-AuNCs) as a sensitive signal reporter. The T-rich MCS ssDNA with the sequence complementary with that for the aptamer of ATP was bound with Hg(2+) to form the metal-paired hairpin-structure. Addition of the aptamer and its target biomolecule ATP resulted in a competitive aptamer bioassay. The aptamer competed with Hg(2+) to hybridize with T-rich MCS ssDNA, thereby destroyed the hairpin-structure. As a result, the Hg(2+) was released and the signal transduction was achieved. The ATP affected the interaction between aptamer and hairpin-structure, thus mediated the release of Hg(2+), which was sensitively quantified by fluorescent MUA-AuNCs. Under selected conditions, the developed method allowed sensitive and selective detection of ATP with a linear range of 100-2000 nM and a detection limit (3s) of 48 nM. The relative standard deviation for sixty replicate detections of 200 nM ATP was 2.1%, and the recoveries of the spiked ATP in urine samples ranged from 89% to 105%. The developed metal-paired MCS can be easily extended to the sensitive and selective detection of other biomolecules by changing the base sequence of hairpin structure and choosing the corresponding aptamer for the target biomolecule.  相似文献   

4.
We describe the first validated scintillation proximity assay (SPA) binding method for quantitation of 3H-labeled d-lysergic acid diethylamide (LSD) binding to recombinant human 5-hydroxytryptamine 6 (5-HT6) receptors expressed in Chinese hamster ovary (CHO)-Dukx and HeLa cells. The assay was developed using intact cells as a receptor source because membrane fractions derived from these cells failed to discern specific binding from a high level of nonspecific binding. The pharmacological binding profile of seven 5-HT6 agonists and antagonists using intact CHO-Dukx/5-HT6 cells in the SPA format was similar to data obtained from a filtration binding assay using HeLa/5-HT6 membranes. Ki values and rank order of potencies obtained in the SPA format were consistent with published filtration data as follows: SB-271046 (Ki = 1.9 nM) > methiothepin (Ki = 6.2 nM) > mianserin (Ki = 74.3 nM) > 5-methoxytryptamine (5-MeOT, Ki = 111 nM) > 5-HT (Ki = 150 nM) > ritanserin (Ki = 207 nM) > 5-carboxamidotryptamine (5-CT, Ki = 704 nM). Additional evaluation with four antipsychotics demonstrated strong agreement with previous literature reports. A high specific binding signal and low assay variability, as determined by Z′ = 0.81 ± 0.017, make the SPA format amenable to automation and higher throughput; hence, this assay can be a viable alternative to the more labor-intensive filtration and centrifugation methods.  相似文献   

5.
This study reports a sensitive analytical method suitable for the quantitative analysis of ethylenethiourea (ETU) in human urine and its application to samples from the general population. Sample preparation involved the use of diatomaceous earth extraction columns to remove matrix interferences. Quantification was achieved by liquid chromatography–mass spectrometry using positive ion atmospheric pressure chemical ionisation. Within-day and between-day variability of 14% (n = 10) and 11% (n = 6), respectively, were obtained at 98 nmol/l (10 μg l−1). The assay was linear over the investigated range 2.5–245 nmol/l, with a limit of detection of 2.5 nmol/l. The method was applied to monitoring background levels of ETU in urine samples from the general population in the UK. Results obtained from 361 spot samples contained ETU levels ranging from less than the detection limit (54% of samples) to a maximum of 15.8 μmol/mol creatinine (14.3 μg/g creatinine). The 95th percentile was 5.7 μmol/mol creatinine (5.2 μg/g creatinine).  相似文献   

6.
N-Arachidonoylethanolamine (AEA, anandamide) was the first endocannabinoid to be identified and has since become associated with the mediation of several physiological functions and disease states. AEA has been isolated from numerous tissues and biofluids, in the low nanomolar range, using lipid extraction techniques with organic solvents. These techniques require the drying down of relatively large volumes of solvents, making them unsuitable for high-throughput analysis. Here we describe a solid-phase extraction (SPE) method for the investigation of AEA concentrations in human plasma, serum, milk, urine, amniotic fluid, peritoneal fluid, saliva, follicular fluid, and fluid from an ovarian cyst. AEA was detected in serum and plasma from blood isolated from 20 adult women (means ± standard deviations: 0.68 ± 0.29 and 0.64 ± 0.28 nM, respectively), from pregnant women at term (1.37 ± 0.42 nM), and from umbilical vein (1.26 ± 0.33 nM) and umbilical artery (1.14 ± 0.35 nM), in milk (0.12 ± 0.05 nM) and from amniotic (0.03 ± 0.02 nM), peritoneal (0.93 ± 0.27 nM), follicular (1.17 ± 0.51 nM), and ovarian cyst (0.32 ± 0.01 nM) fluids. AEA was undetectable in saliva and urine. The 60% AEA extraction efficiency achieved with SPE from plasma was superior to the 19% efficiency achieved using the existing organic solvent extraction method. Limits of quantification and detection for AEA were also improved dramatically using SPE (8 and 4 fmol/ml) compared with organic extraction (25 and 18.75 fmol/ml plasma). These improvements allow the use of smaller plasma samples with SPE. Intra- and interday variability were comparable, and the mean AEA concentration of pooled plasma samples (1.18 nM, n = 15) was identical with the two techniques. Similarly, when 56 plasma samples from laboring and nonlaboring women were analyzed using both techniques, no extraction method-dependent differences were observed. Consequently, we provide evidence for a robust SPE technique for the extraction of AEA from biomatrices to replace the existing liquid extraction methods, with the SPE technique being superior in terms of speed, extraction efficiency, and sample size required.  相似文献   

7.
A homogeneous chemiluminescent immunoassay of thyroxine (T4) enhanced by microchip electrophoresis separation has been developed. The method deployed the competitive immunoreaction of T4 and horseradish peroxidase (HRP)-labeled T4 (HRP-T4) with anti-T4 mouse monoclonal antibody (Ab). HRP-T4 and the HRP-T4-Ab complex were separated and quantified by using microchip electrophoresis (MCE) with chemiluminescence (CL) detection. Highly sensitive CL detection was achieved by means of HPR-catalyzed luminol-H2O2 reaction. Due to the effective MCE separation, the CL analytical signal was less prone to sample matrix interference. Under the selected assay conditions, the MCE separation was accomplished within 60 s. The linear range for T4 was 5-250 nM with a detection limit of 2.2 nM (signal/noise ratio = 3). The current method was successfully applied for the quantification of T4 in human serum samples. It was demonstrated that the current MCE-CL-enhanced competitive immunoassay was quick, sensitive, and highly selective. It may serve as a tool for clinical analysis of T4 to assist in the diagnosis of thyroid gland functions.  相似文献   

8.
In this protocol, the authors report a time-resolved fluorescence biosensor based on home-made europium complexes for highly sensitive detection of small molecules using adenosine as a model analyte. The fluorophore that used is europium complexes. Its signal can be measured in a time-resolved manner that eliminates most of the unspecific fluorescent background. The amino modified aptamer probe, which is designed to specifically recognize adenosine, is combined to the aldehyde-group modified glass slide by covalent bond. Europium complex-labeled a short ssDNA, designed to segment hybridize with aptamer probe is immobilized on the glass slide by hybridization reaction. In the presence of adenosine, the aptamer part is more inclined to bounds with adenosine and triggers structure-switching of the aptamer from aptamer/ssDNA duplex to aptamer/target complex. As a result, europium complexes-labeled ssDNA is forced to dissociate from the sensor interface, resulting in time-resolved fluorescence intensity decrease. The decrement intensity is proportional to the amount of adenosine. Under optimized assay conditions, a linear range (1.0×10(-8)M to 1.0×10(-7)M) is got with low detection limit of 5.61nM. The biosensor exhibits excellent selectivity and can provide a promising potential for aptamer-based adenosine detection.  相似文献   

9.
Zhao S  Wang J  Ye F  Liu YM 《Analytical biochemistry》2008,378(2):127-131
A simple and sensitive method based on capillary electrophoresis (CE) with chemiluminescence (CL) detection has been developed for the determination of uric acid (UA). The sensitive detection was based on the enhancement effect of UA on the CL reaction between luminol and potassium ferricyanide (K3[Fe(CN)6]) in alkaline solution. A laboratory-built reaction flow cell and a photon counter were deployed for the CL detection. Experimental conditions for CL detection were studied in detail to achieve a maximum assay sensitivity. Optimal conditions were found to be 1.0 × 10−4 M luminol added to the CE running buffer and 1.0 × 10−4 M K3[Fe(CN)6] in 0.2 M NaOH solution introduced postcolumn. The proposed CE-CL assay showed good repeatability (relative standard deviation [RSD] = 3.5%, n = 11) and a detection limit of 3.5 × 10−7 M UA (signal/noise ratio [S/N] = 3). A linear calibration curve ranging from 6.0 × 10−7 to 3.0 × 10−5 M UA was obtained. The method was evaluated by quantifying UA in human urine and serum samples with satisfactory assay results.  相似文献   

10.
A method for the detection of trehalose-6-phosphate (T6P) in tissue of the model plant Arabidopsis thaliana is presented. Liquid-liquid extraction (LLE) and mixed mode solid-phase extraction (SPE) were used for sample pretreatment followed by anion exchange chromatography (AEC) coupled with electrospray ionization mass spectrometry (MS) for highly selective quantitative analysis. LLE of plant material was performed with chloroform/acetonitrile/water (3:7:16, v/v/v) followed by SPE with Oasis MAX material, which significantly reduced the complexity of the extracts. On-line coupling of MS with gradient AEC using a sodium hydroxide eluent was accomplished with a postcolumn ion suppressor. The method allows specific quantification of T6P with good linearity for spiked plant extracts, from 80 nM to 1.3 μM (r2 > 0.98). The limit of detection in plant extracts was 40 nM. The recovery of the method was above 80% for relevant T6P levels. The method was applied to the determination of T6P in seedlings from four mutant A. thaliana lines (TRR1-4) resisting growth arrest caused by external supply of trehalose. Results reveal that T6P accumulation differed substantially in the four mutant lines and wild type (WT). It is concluded that the mutants circumvent the growth arrest observed in WT seedlings on 100 mM trehalose by different mechanisms.  相似文献   

11.
There is heightened interest in determining antioxidant status of individuals in experimental and clinical studies investigating progression of diseases or diverse aspects of oxidative stress, among others. The aim of this study was to evaluate the copper(II) reduction assay with bathocuproinedisulfonic acid disodium salt as chelating agent (the CUPRAC-BCS assay) for the total antioxidant capacity (TAC) assessment in human plasma and urine. Samples from 20 individuals were determined with four spectrophotometric assays—CUPRAC-BCS, ferric reducing ability of plasma (FRAP), trolox equivalent antioxidant capacity (TEAC), and 1,1-diphenyl-2-picrylhydrazyl assay (DPPH)—to compare these methods. CUPRAC-BCS was significantly correlated with FRAP and TEAC for plasma and urine samples (r > 0.5, P < 0.05 for all) and with DPPH for urine samples (r = 0.925, P < 0.001) but not with DPPH for plasma samples (r = 0.366, P = 0.112). However, the four methods do not agree given that lines of equality and regression were not matched up. The imprecision of the method is less than 6%, the detection limit is 41.8 μmol trolox equivalents/L, it is linear up to 2 mM trolox, and ethylenediaminetetraacetic acid dihydrate disodium salt (EDTA) binds to Cu(II), avoiding the formation of Cu(I)-BCS complex. This study shows that CUPRAC-BCS is a simple, fast, inexpensive, and suitable method for TAC assessment in human urine and heparinized plasma samples.  相似文献   

12.
A simple colorimetric biosensing technique based on the interaction of gold nanoparticles (AuNPs) with the aptamer was developed for detection of p53, a tumor suppressor protein, in the current study. Aggregation of AuNPs was induced by desorption of the p53 binding RNA aptamer from the surface of AuNPs as a result of the aptamer target interaction leading to the color change of AuNPs from red to purple. The detection limit of p53 protein by the colorimetric approach was 0.1 ng/ml after successful optimization of the amount of aptamer, AuNPs, salts, and incubation time. Furthermore, the catalytic activity of the aggregated AuNPs was greatly enhanced by chemiluminescence (CL) reaction, where the detection limit was enhanced to 10 pg/ml with a regression coefficient of R2 = 0.9907. Here the sensitivity was increased by 10-fold compared with the AuNP-based colorimetric method. Hence, the sensitivity of detection was increased by employing CL, by using the catalytic activity of aggregated AuNPs, on the luminol–hydrogen peroxide reaction. Thus, the combination of colorimetric and CL-based aptasensor can be of great advantage in increasing the sensitivity of detection for any target analyte.  相似文献   

13.
This paper proposes an aptasensor for progesterone (P4) detection in human serum and urine based on the aggregating behavior of gold nanoparticles (AuNPs) controlled by the interactions among P4-binding aptamer, target P4 and cationic surfactant hexadecyltrimethylammonium bromide (CTAB). The aptamer can form an aptamer-P4 complex with P4, leaving CTAB free to aggregate AuNPs in this aptasensor. Thus, the sensing solution will turn from red (520 nm) to blue (650 nm) in the presence of P4 because P4 aptamers are used up firstly owing to the formation of an aptamer-P4 complex, leaving CTAB free to aggregate AuNPs. However, in the absence of P4, CTAB combines with aptamers so that AuNPs still remain dispersed. Therefore, this assay makes it possible to detect P4 not only by absorbance measurement but also through naked eyes. By monitoring the variation of absorbance and color, a CTAB-induced colorimetric assay for P4 detection was established with a detection limit of 0.89 nM. Besides, the absorbance ratio A650/A520 has a linear correlation with the P4 concentration of 0.89–500 nM. Due to the excellent recoveries in serum and urine, this biosensor has great potential with respect to the visual and instrumental detection of P4 in biological fluids.  相似文献   

14.
In this article, we describe a simple, sensitive, accurate, and repeatable method for the measurement of phenol and p-cresol (4-methylphenol) in human urine and feces. We examined a number of parameters to identify an optimal extraction protocol. Purification of sample extracts was achieved by low-temperature vacuum microdistillation. Separation was achieved in approximately 15 min by high-performance liquid chromatography (HPLC) with quantification by fluorescence at 284/310 nm. Limits of detection for phenol were 2 ng/ml for urine and 20 ng/g for feces, and those for p-cresol were 10 ng/ml for urine and 100 ng/g for feces. For comparison, approximate mean values for urine are 3 μg/ml for phenol and 30 μg/ml for p-cresol, and those for feces are 1 μg/g for phenol and 50 μg/g for p-cresol. An experienced analyst can process 60 samples each day using this method.  相似文献   

15.
16.
Here, we describe the fabrication of an electrochemical immunoglobulin E (IgE) aptasensor using enzyme-linked aptamer in the sandwich assay method and thionine as redox probe. In this protocol, 5′-amine-terminated IgE aptamer and thionine were covalently attached on glassy carbon electrode modified with carbon nanotubes/ionic liquid/chitosan nanocomposite. Furthermore, another IgE aptamer was modified with biotin and enzyme horseradish peroxidase (HRP), which attached to the aptamer via biotin–streptavidin interaction. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry were performed at each stage of the chemical modification process to confirm the resulting surface changes. The presence of IgE induces the formation of a double aptamer sandwich structure on the electrode, and the electrocatalytic reduction current of thionine in the presence of hydrogen peroxide was measured as the sensor response. Under optimized conditions and using differential pulse voltammetry as the measuring technique, the proposed aptasensor showed a low detection limit (6 pM) and high sensitivity (1.88 μA nM−1). This aptasensor also exhibited good stability and high selectivity for IgE detection without an interfering effect of some other proteins such as bovine serum albumin (BSA) and lysozyme. The application of the aptasensor for IgE detection in human serum sample was also investigated. The proposed protocol is quite promising as an alternative sandwich approach for various protein assays.  相似文献   

17.
An interesting electrochemical sensor has been constructed by the electrodeposition of palladium nanoclusters (Pdnano) on poly(N-methylpyrrole) (PMPy) film-coated platinum (Pt) electrode. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS), and scanning electron microscopy were used to characterize the properties of the modified electrode. It was demonstrated that the electroactivity of the modified electrode depends strongly on the electrosynthesis conditions of the PMPy film and Pdnano. Moreover, the modified electrode exhibits strong electrocatalytic activity toward the oxidation of a mixture of dopamine (DA), ascorbic acid (AA), and uric acid (UA) with obvious reduction of overpotentials. The simultaneous analysis of this mixture at conventional (Pt, gold [Au], and glassy carbon) electrodes usually struggles. However, three well-resolved oxidation peaks for AA, DA, and UA with large peak separations allow this modified electrode to individually or simultaneously analyze AA, DA, and UA by using differential pulse voltammetry (DPV) with good stability, sensitivity, and selectivity. This sensor is also ideal for the simultaneous analysis of AA, UA and either of epinephrine (E), norepinephrine (NE) or l-DOPA. Additionally, the sensor shows strong electrocatalytic activity towards acetaminophen (ACOP) and other organic compounds. The calibration curves for AA, DA, and UA were obtained in the ranges of 0.05 to 1 mM, 0.1 to 10 μM, and 0.5 to 20 μM, respectively. The detection limits (signal/noise [S/N] = 3) were 7 μM, 12 nM, and 27 nM for AA, DA, and UA, respectively. The practical application of the modified electrode was demonstrated by measuring the concentrations of AA, DA, and UA in injection sample, human serum, and human urine samples, respectively, with satisfactory results. The reliability and stability of the modified electrode gave a good possibility for applying the technique to routine analysis of AA, DA, and UA in clinical tests.  相似文献   

18.
In the present study, we report a novel sensitive method for the detection of adenosine using surface-enhanced Raman scattering (SERS) sensing platform based on a structure-switching aptamer. First, Ag-clad Au colloids film on a polished gold disc is prepared as enhanced substrate and modified with thiolated capture DNA. The formation of an aptamer/DNA duplex of expanded anti-adenosine aptamer and tetramethylrhodamine-labeled DNA (denoted TMR-DNA) is then developed, in which TMR-DNA could also hybridize completely with capture DNA. The introduction of adenosine thus triggers structure switching of the aptamer from aptamer/DNA duplex to aptamer/target complex. As a result, the released TMR-DNA is captured onto the SERS substrate, resulting in an increase of SERS signal. Under optimized assay conditions, a wide linear dynamic range (2.0x10(-8)M to 2x10(-6)M) was reached with low detection limit (1.0x10(-8)M). Moreover, high selectivity, stability and facile regeneration are achieved. The successful test demonstrates the feasibility of the strategy for adenosine assay.  相似文献   

19.
Hollow fiber liquid-phase microextraction (HF-LPME) coupled with high-performance liquid chromatography was used to simultaneously determine three Aconitum alkaloids, including aconitine (AC), hypaconitine (HA) and mesaconitine (MA) in human urine sample. Analytes were extracted from 5 mL urine sample containing 1.0 mmol/L NaOH into 1-octanol membrane phase impregnated in the pores of hollow fiber wall, and then back extracted into acidified aqueous solution in the lumen of the hollow fiber. After extraction, 10 μL of the acceptor phase was analyzed directly by HPLC. In this method, some important extraction parameters, such as organic solvent, extraction time, stirring rate, pH of donor phase and acceptor phase, temperature, and the volume of acceptor phase were optimized. This method provided 98- to 288-fold enrichment factors within 60 min of extraction and good repeatability with RSDs of 0.99–7.22%. The calibration curves were linear over the ranges of 16.0–128.0 μg/L for AC, 11.0–88.0 μg/L for HA and 8.1–64.8 μg/L for MA in human urine sample, with correlation coefficients of 0.9949, 0.9969 and 0.9904, respectively. Limits of detection were from 0.7 to 1.5 μg/L, and recoveries from spiked urine sample varied from 84.4% to 106.2% for AC, 77.3% to 85.6% for HA and 90.1% to 100.8% for MA.  相似文献   

20.
Plasma renin activity (PRA) is a well-established biomarker for assessing the efficacy of various antihypertensive agents such as direct renin inhibitors, angiotensin receptor blockers, and angiotensin-converting enzyme inhibitors (ACEIs). PRA measurements are obtained through the detection and quantification of angiotensin I (Ang I) produced by the action of renin on its natural substrate angiotensinogen. The most accepted and reproducible method for PRA measurement uses an antibody capture Ang I methodology that employs specific antibodies that recognize and protect Ang I against angiotensinase activities contained in plasma. The amount of Ang I is then quantified by either radioimmunoassay (RIA) or enzyme immunoassay (EIA). In the current report, we describe the optimization of a novel homogeneous immunoassay based on the AlphaScreen technology for the detection and quantification of antibody-captured Ang I using AlphaLISA acceptor beads in buffer and in the plasma of various species (human, rat, and mouse). Ex vivo measurements of renin activity were performed using 10 μl or less of a reaction mixture, and concentrations as low as 1 nM Ang I were quantified. Titration curves obtained for the quantification of Ang I in buffer and plasma gave similar EC50 values of 5.6 and 14.4 nM, respectively. Both matrices generated an equivalent dynamic range that varies from approximately 1 to 50 nM. Renin inhibitors have been successfully titrated and IC50 values obtained correlated well with those obtained using EIA methodology (r2 = 0.80). This assay is sensitive, robust, fast, and less tedious than measurements performed using nonhomogeneous EIA. The AlphaLISA methodology is homogeneous, does not require wash steps prior to the addition of reagents, and does not generate radioactive waste.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号