首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Lead sulfide (PbS) nanoparticles were synthesized in aqueous solution and used as oligonucleotide labels for electrochemical detection of the 35 S promoter from cauliflower mosaic virus (CaMV) sequence. The PbS nanoparticles were modified with mercaptoacetic acid and could easily be linked with CaMV 35 S oligonucleotide probe. Target DNA sequences were covalently linked on a mercaptoacetic acid self-assembled gold electrode, and DNA hybridization of target DNA with probe DNA was completed on the electrode surface. PbS nanoparticles anchored on the hybrids were dissolved in the solution by oxidation of HNO3 and detected using a sensitive differential pulse anodic stripping voltammetric method. The detection results can be used to monitor the hybridization reaction. The CaMV 35 S target sequence was satisfactorily detected with the detection limit as 4.38 × 10−12 mol/L (3σ). The established method extends nanoparticle-labeled electrochemical DNA analysis to specific sequences from genetically modified organisms with higher sensitivity and selectivity.  相似文献   

2.
In the present study, a gold nanoparticle-modified gold electrode (nanogold electrode) was used to develop a novel fluorescein electrochemical DNA biosensor based on a target-induced conformational change. The nanogold electrode was obtained by electrodepositing gold nanoparticles onto a bare gold electrode. This modification not only immobilized probe oligonucleotides, but also adsorbed fluorescein onto the surface of the gold nanoparticles to form an “arch-like” structure. This article compares the electrochemical signal changes caused by the hybridization of “arch-like” DNA on nanogold electrode and linear DNA on bare gold electrode. The results showed that the adsorption effect of nanogold can enhance the sensitivity of the sensor. The linear range of target ssDNA is from 2.0 × 10−9 M to 2.0 × 10−8 M with a correlation coefficient of 0.9956 and detection limit (3σ) of 7.10 × 10−10 M. Additionally, the specificity and hybridization response of this simple sensor were investigated.  相似文献   

3.
We have designed a simple and novel electrochemical biosensor based on glassy carbon electrode (GCE) for DNA detection. GCE was modified with reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) by the electrochemical method, which is helpful for immobilization of thiolated bioreceptors. The electrode modification processes were characterized by scanning electron microscopy (SEM) and electrochemical methods. Then a single-stranded DNA (ssDNA) probe for BRCA1 5382 insC mutation detection was immobilized on the modified electrode for a specific time. The experimental conditions, such as probe immobilization time and target DNA (complementary DNA) hybridization time and temperature with probe DNA, were optimized using electrochemical methods. The electrochemical response for DNA hybridization and synthesis was measured using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) methods. The calibration graph contains two linear ranges; the first part is in the range of 3.0 × 10−20 to 1.0 × 10−12 M, and the second segment part is in the range of 1.0 × 10−12 to 1.0 × 10−7 M. The biosensor showed excellent selectivity for the detection of the complementary sequences from noncomplementary sequences, so it can be used for detection of breast cancer.  相似文献   

4.
A direct electrochemical DNA biosensor based on zero current potentiometry was fabricated by immobilization of ssDNA onto gold nanoparticles (AuNPs) coated pencil graphite electrode (PGE). One ssDNA/AuNPs/PGE was connected in series between clips of working and counter electrodes of a potentiostat, and then immersed into the solution together with a reference electrode, establishing a novel DNA biosensor for specific DNA detection. The variation of zero current potential difference (ΔE(zcp)) before and after hybridization of the self-assembled probe DNA with the target DNA was used as a signal to characterize and quantify the target DNA sequence. The whole DNA biosensor fabrication process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the use of ferricyanide as an electrochemical redox indicator. Under the optimized conditions, ΔE(zcp) was linear with the concentrations of the complementary target DNA in the range from 10nM to 1μM, with a detection limit of 6.9nM. The DNA biosensor showed a good reproducibility and selectivity. Prepared DNA biosensor is facile and sensitive, and it eliminates the need of using exogenous reagents to monitor the oligonucleotides hybridization.  相似文献   

5.
An electrochemical DNA sensor based on the hybridization recognition of a single-stranded DNA (ssDNA) probe immobilized onto a gold electrode to its complementary ssDNA is presented. The DNA probe is bound on gold surface electrode by using self-assembled monolayer (SAM) technology. An optimized mixed SAM with a blocking molecule preventing the nonspecific adsorption on the electrode surface has been prepared. In this paper, a DNA biosensor is designed by means of the immobilization of a single stranded DNA probe on an electrochemical transducer surface to recognize specifically Escherichia coli (E. coli) 0157:H7 complementary target DNA sequence via cyclic voltammetry experiments. The 21 mer DNA probe including a C6 alkanethiol group at the 5' phosphate end has been synthesized to form the SAM onto the gold surface through the gold sulfur bond. The goal of this paper has been to design, characterise and optimise an electrochemical DNA sensor. In order to investigate the oligonucleotide probe immobilization and the hybridization detection, experiments with different concentration of DNA and mismatch sequences have been performed. This microdevice has demonstrated the suitability of oligonucleotide Self-assembled monolayers (SAMs) on gold as immobilization method. The DNA probes deposited on gold surface have been functional and able to detect changes in bases sequence in a 21-mer oligonucleotide.  相似文献   

6.
For the detection of DNA hybridization, a new electrochemical biosensor was developed on the basis of the interaction of hematoxylin with 20-mer deoxyoligonucleotides (from human papilloma virus, HPV). The study was performed based on the interaction of hematoxylin with an alkanethiol DNA probe self-assembled gold electrode (ss-DNA/AuE) and its hybridization form (ds-DNA/AuE). The optimum conditions were found for the immobilization of HPV probe on the gold electrode (AuE) surface and its hybridization with the target DNA. Electrochemical detection of the self-assembled DNA and the hybridization process were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over the potential range where the accumulated hematoxylin at the modified electrode was electroactive. Observing a remarkable difference between the voltammetric signals of the hematoxylin obtained from different hybridization samples (non-complementary, mismatch and complementary DNAs), we confirmed the potential of the developed biosensor in detecting and discriminating the target complementary DNA from non-complementary and mismatch oligonucleotides. Under optimum conditions, the electrochemical signal had a linear relationship with the concentration of the target DNA ranging from 12.5 nM to 350.0 nM, and the detection limit was 3.8 nM.  相似文献   

7.
In this article, a supersandwich-type electrochemical biosensor for sequence-specific DNA detection is described. In design, single-strand DNA labeled with methylene blue (MB) was used as signal probe, and auxiliary probe was designed to hybridize with two different regions of signal probe. The biosensor construction contained three steps: (i) capture DNA labeled with thiol was immobilized on the surface of gold nanoparticles decorated reduced graphene oxide (Au NPs/rGO); (ii) the sandwich structure formation contained “capture–target–signal probe”; and (iii) auxiliary probe was introduced to produce long concatamers containing signal molecule MB. Differential pulse voltammetry (DPV) was used to monitor the DNA hybridization event using peak current changes of MB in phosphate-buffered saline (PBS) containing 1.0 M NaClO4. Under optimal conditions, the peak currents of MB were linear with the logarithm of the concentration of target DNA in the range of 0.1 μM to 0.1 fM with a detection limit of 35 aM (signal/noise = 3). In addition, this biosensor exhibited good selectivity even for single-base mismatched target DNA detection.  相似文献   

8.
The aim of this study was to construct a gene chip system based on a surface plasmon resonance technique, where peptide nucleic acid (PNA) oligomers are used as probes. Since the self-assembled monolayer (SAM) technology offers good control at the molecular level, we prepared 2D surface chemistry via SAM for probe attachments. PNA, which was designed according to the bioinformatics, was immobilized on the SAM-modified chip, and subsequently, relevant parameters of the experiment were ensured and optimized. Our results suggest that the ion strength and pH value of the buffer solution do not play significant roles in PNA or its complementary strand hybridization. The PNA probe binds to its complementary nucleic acid strand with a higher sensitivity and specificity compared to those of a traditional DNA probe. The PNA probe combined with surface plasmon resonance (SPR) technology has the benefits of being a label-free and in-real time monitor, as well as having improved hybridization and stability efficiency, which highlight the PNA gene chip detection system as a promising biosensor for clinical applications.  相似文献   

9.
An electrochemical genosensor for the detection of hypermethylation of the glutathione S-transferase P1 (GSTP1) gene, a specific marker of prostate cancer, was reported. This new sensor was used in combination with a single-use carbon graphite working electrode and differential pulse voltammetry, with the results of sample analysis based on the guanine oxidation signals obtained at +1.0 V before and after hybridization between probe and synthetic target or denatured PCR samples. The detected DNA hybridization was also characterized by electrochemical impedance spectroscopy with potassium ferri/ferrocyanide as a redox probe. The protocol consisted of 2 different modes: (i) capture probes selective for methylation-specific and unmethylated GSTP1 sequences were immobilized onto the sensor directly, and hybridization was formed on the electrode surface; (ii) probe/target or probe/noncomplementary target couples were mixed in solution phase, and the transducer was modified through simple adsorption. The limit of detection (S/N=3) was calculated as 2.92 pmol of target sequence in a 100-μl reaction volume. The optimum analytical detection parameters for the biosensor, as well as its future prospects, were also presented.  相似文献   

10.
We have designed an electrochemical DNA biosensor based on stem-loop structured probes for enzymatic detection of Pseudomonas aeruginosa 16S ribosomal RNA (rRNA) in composting degradation. The probe modified with a thiol at its 5′ end and a biotin at its 3′ end was immobilized on a gold electrode through self-assembly. The stem-loop structured probes were “closed” when target was absent, then the hybridization of the target induced the conformational changes to “open”, along with the biotin at its 3′ end binding with streptavidin-horseradish peroxidase (HRP), and subsequent quanti?cation of the target was detected via electrochemical detecting the enzymatic product in the presence of substrate. Under the optimum experiment conditions, the amperometric current response to HRP-catalyzed reaction was linearly related to the logarithm of the target nucleic acid concentration, ranging from 0.3 and 600 pg/μL, with the detection limit of 0.012 pg/μL. A correlation coefficient of 0.9960 was identified. The 16S rRNA extracted from P. aeruginosa was analyzed by this proposed sensor. The results were in agreement with the reference values deduced from UV spectrometric data. The biosensor was indicative of good precision, stability, sensitivity, and selectivity.  相似文献   

11.
A detection technique with a DNA probe was developed for the bloom‐forming alga Alexandrium affine harvested in Japan. The design of this probe was based on the sequence polymorphism within the 28S ribosomal DNA (rDNA) of this strain using the BIAcore? 2000 biosensor, which determines surface plasmon resonance. The specific DNA sequence in 28S rDNA for A. affine was determined by sequence data analysis, and a probe was designed for the detection of A. affine. A fragment of the 28S rDNA from A. affine was amplified by polymerase chain reaction and applied to the BIAcore? sensor system, and the target DNA was selectively recognized by species‐specific hybridization using two DNA probes: a fluorescein isothiocyanate (FITC)‐labeled probe and a biotin‐labeled DNA probe. Using FITC‐labeled anti‐immunogloblin G antibody, enhancement of the response for the target DNA can be detected directly as a resonant unit change. In this detection method, a difference within only 20 base pairs of the target could be detected, and specific detection of A. affine was achieved intraspecifically.  相似文献   

12.
Li XM  Zhan ZM  Ju HQ  Zhang SS 《Oligonucleotides》2008,18(4):321-327
A novel label-free electrochemical DNA biosensor based on 4,4'-diaminoazobenzene (4,4'-DAAB) and multiwalled carbon nanotube (MWNT)-modified glassy carbon electrode (GCE) for short DNA sequences related to the hepatitis B virus (HBV) hybridization detection was presented. Differential pulse voltammetry (DPV) was used to investigate hybridization event. The decrease in the peak current of 4,4'-DAAB was observed on hybridization of probe with the target. This electrochemical approach was sequence specific as indicated by the control experiments, in which no peak current change was observed when a noncomplementary DNA sequence was used. Numerous factors affecting the target hybridization were optimized to maximize the sensitivity. Under optimal conditions, this sensor showed a good calibration range between 7.94 x 10(-8) M and 1.58 x 10(-6) M, with HBV DNA sequence detection limit of 1.1 x 10(-8) M.  相似文献   

13.
In this work, we present an electrochemical DNA sensor based on silver nanoparticles/poly(trans-3-(3-pyridyl) acrylic acid) (PPAA)/multiwalled carbon nanotubes with carboxyl groups (MWCNTs-COOH) modified glassy carbon electrode (GCE). The polymer film was electropolymerized onto MWCNTs-COOH modified electrode by cyclic voltammetry (CV), and then silver nanoparticles were electrodeposited on the surface of PPAA/MWCNTs-COOH composite film. Thiol group end single-stranded DNA (HS-ssDNA) probe was easily covalently linked onto the surface of silver nanoparticles through a 5′ thiol linker. The DNA hybridization events were monitored based on the signal of the intercalated adriamycin by differential pulse voltammetry (DPV). Based on the response of adriamycin, only the complementary oligonucleotides gave an obvious current signal compared with the three-base mismatched and noncomplementary oligonucleotides. Under the optimal conditions, the increase of reduction peak current of adriamycin was linear with the logarithm of the concentration of the complementary oligonucleotides from 9.0 × 10−12 to 9.0 × 10−9 M with a detection limit of 3.2 × 10−12 M. In addition, this DNA sensor exhibited an excellent reproducibility and stability during DNA hybridization assay.  相似文献   

14.
We report on the study of immobilization DNA probes onto quartz crystal oscillators by self-assembly technique to form variety types of mono- and multi-layered sensing films towards the realization of DNA diagnostic devices. A 18-mer DNA probe complementary to the site of genetic beta-thalassaemia mutations was immobilized on the electrodes of QCM by covalent bonding or electrostatic adsorption on polyelectrolyte films to form mono- or multi-layered sensing films by self-assembled process. Hybridization was induced by exposure of the QCMs immobilized with DNA probe to a test solution containing the target nucleic acid sequences. The kinetics of DNA probe immobilization and hybridization with the fabricated DNA sensors were studied via in-situ frequency changes. The characteristics of QCM sensors containing mono- or multi-layered DNA probe constructed by direct chemical bonding, avidin-biotin interaction or electrostatic adsorption on polyelectrolyte films were compared. Results indicated that the DNA sensing films fabricated by immobilization of biotinylated DNA probe to avidin provide fast sensor response and high hybridization efficiencies. The effects of ionic strength of the buffer solution and the concentration of target nucleic acid used in hybridization were also studied. The fabricated DNA biosensor was used to detect a set of real samples. We conclude that the microgravimetric DNA sensor with its direct detection of amplified products provide a rapid, low cost and convenient diagnostic method for genetic disease.  相似文献   

15.
Although the analyses of HBV genomic DNA have traditionally been performed with commercial techniques, the high cost and long time consumed have hindered their applications in routinely diagnosis and prognosis of infection. We construct peptide nucleic acid (PNA) piezoelectric biosensor for real-time monitoring of hybridization of hepatitis B virus (HBV) genomic DNA. The PNA probe can combine to target DNA sequences more effectively and specifically than a DNA probe. The PNA probe was designed and immobilized on the surface of the biosensor to substitute the conventional DNA probe for direct detection of HBV genomic DNA without previous amplification by PCR. The hybridization assay was completed in 50 min. The detection limit was 8.6 pg/L and the clinical specificity was 94.44% compared with real time-PCR (RT-PCR). The PNA probe was able to distinguish sequences that differ only in one base. Detection sensitivity can be improved and detection time can be decreased by adding RecA protein-coated complementary ssDNA which complement to HBV gene regions. The QCM system we designed has the advantages of being rapid, label-free and highly sensitive and can be a useful supplement to commercial assay methods in clinical chemistry.  相似文献   

16.
Zhang J  Song S  Wang L  Pan D  Fan C 《Nature protocols》2007,2(11):2888-2895
We report a protocol for the amplified detection of target DNA by using a chronocoulometric DNA sensor (CDS). Electrochemistry is known to be rapid, sensitive and cost-effective; it thus offers a promising approach for DNA detection. Our CDS protocol is based on a 'sandwich' detection strategy, involving a capture probe DNA immobilized on a gold electrode and a reporter probe DNA loaded on gold nanoparticles (AuNPs). Each probe flanks one of two fragments of the target sequence. A single DNA hybridization event brings AuNPs, along with hundreds of reporter probes, in the proximity of the electrode. We then employ chronocoulometry to interrogate [Ru(NH3)6]3+ electrostatically bound to the captured DNA strands. This AuNP-amplified DNA sensor can selectively detect as low as femtomolar (zeptomoles) concentrations of DNA targets and conveniently analyze a breast cancer-associated BRCA-1 mutant DNA. The time range for the entire protocol is approximately 3 d, whereas the DNA sensing takes less than 2 h to complete.  相似文献   

17.
A novel hybridization indicator, bis(benzimidazole)cadmium(II) dinitrate (Cd(bzim)(2)(NO(3))(2)), was utilized to develop an electrochemical DNA biosensor for the detection of a short DNA sequence related to the hepatitis B virus (HBV). The sensor relies on the immobilization and hybridization of the 21-mer single-stranded oligonucleotide from the HBV long repeat at the glassy carbon electrode (GCE). The hybridization between the probe and its complementary sequence as the target was studied by enhancement of the peak of the Cd(bzim)(2)(2+) indicator using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Numerous factors affecting the probe immobilization, target hybridization, and indicator binding reactions were optimized to maximize the sensitivity and speed of the assay time. With this approach, a sequence of the HBV could be quantified over the range from 1.49x10(-7)M to 1.06x10(-6)M, with a linear correlation of r=0.9973 and a detection limit of 8.4x10(-8)M. The Cd(bzim)(2)(2+) signal observed from the probe sequence before and after hybridization with a four-base mismatch containing sequence was lower than that observed after hybridization with a complementary sequence, showing good selectivity. These results demonstrate that the Cd(bzim)(2)(2+) indicator provides great promise for the rapid and specific measurement of the target DNA.  相似文献   

18.
Disposable DNA electrochemical sensor for hybridization detection   总被引:3,自引:0,他引:3  
A disposable electrochemical sensor for the detection of short DNA sequences is described. Synthetic single-stranded oligonucleotides have been immobilized onto graphite screen printed electrodes with two procedures, the first involving the binding of avidinbiotinylated oligonucleotide and the second adsorption at a controlled potential. The probes were hybridized with different concentrations of complementary sequences. The formed hybrids on the electrode surface were evaluated by differential pulse voltammetry and chronopotentiometric stripping analysis using daunomycin hydrochloride as indicator of hybridization reaction. The probe immobilization step, the hybridization event and the indicator detection, have been optimized. The DNA sensor obtained by adsorption at a controlled potential was able to detect 1 microgram/ml of target sequence in the buffer solution using chronopotentiometric stripping analysis.  相似文献   

19.
A simple electrochemical sensor for sensitive and selective DNA detection was constructed based on gold nanorods (Au NRs) decorated graphene oxide (GO) sheets. The high-quality Au NRs–GO nanocomposite was synthesized via the electrostatic self-assembly technique, which is considered a potential sensing platform. Differential pulse voltammetry was used to monitor the DNA hybridization event using methylene blue as an electrochemical indicator. Under optimal conditions, the peak currents of methylene blue were linear with the logarithm of the concentrations of complementary DNA from 1.0 × 10−9 to 1.0 × 10−14 M with a detection limit of 3.5 × 10−15 M (signal/noise = 3). Moreover, the prepared electrochemical sensor can effectively distinguish complementary DNA sequences in the presence of a large amount of single-base mismatched DNA (1000:1), indicating that the biosensor has high selectivity.  相似文献   

20.
The synthesis and characterization of isotopomer tandem nucleic acid mass tag–peptide nucleic acid (TNT–PNA) conjugates is described along with their use as electrospray ionisation-cleavable (ESI-Cleavable) hybridization probes for the detection and quantification of target DNA sequences by electrospray ionisation tandem mass spectrometry (ESI-MS/MS). ESI-cleavable peptide TNT isotopomers were introduced into PNA oligonucleotide sequences in a total synthesis approach. These conjugates were evaluated as hybridization probes for the detection and quantification of immobilized synthetic target DNAs using ESI-MS/MS. In these experiments, the PNA portion of the conjugate acts as a hybridization probe, whereas the peptide TNT is released in a collision-based process during the ionization of the probe conjugate in the electrospray ion source. The cleaved TNT acts as a uniquely resolvable marker to identify and quantify a unique target DNA sequence. The method should be applicable to a wide variety of assays requiring highly multiplexed, quantitative DNA/RNA analysis, including gene expression monitoring, genetic profiling and the detection of pathogens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号