首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the quantitative analysis of cudratricusxanthone B (CXB) in rat plasma by high performance liquid chromatography–electrospray ionization-tandem mass spectrometry (HPLC–ESI-MS/MS) has been developed and validated. The method involved liquid–liquid extraction from plasma, simple chromatographic conditions on a Venusil XBP-PH C18 column with the mobile phase of 0.5% formic acid in methanol, and mass spectrometric detection using an API-3000 instrument. Multiple reaction monitoring (MRM) mode was used to monitor precursor/product ion transitions of m/z 397.1/285.0 for CXB and m/z 381.6/269.2 for the internal standard (I.S.) cudraxanthone H. The standard curves were linear over the concentration range of 1–500 ng/mL for CXB in rat plasma. The intra- and inter-batch accuracy for CXB at four concentrations was 89.4–99.5% and 89.4–100.8%, respectively. The RSDs were less than 7.92%. The lower limit of quantification for CXB was 1.0 ng/mL using 100 μL of plasma. The average extraction recoveries of CXB ranged from 80.1 to 95.4% at the concentrations of 2, 50 and 500 ng/mL, respectively. This method was successfully applied to the pharmacokinetic study after an intravenous administration of CXB in male Sprague–Dawley (SD) rats.  相似文献   

2.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

3.
BMS-708163 is a γ-secretase inhibitor that is being developed for the treatment of Alzheimer's disease. Several LC–MS/MS methods have been developed for the determination of BMS-708163 in both plasma and cerebrospinal fluid in support of dog, rat, mouse and human studies. To support non-clinical studies, an LC–MS/MS method with a lower limit of quantitation (LLOQ) of 5 ng/mL, was developed and validated in dog, rat, and mouse plasma by using the deprotonated ion as the precursor ion. To support clinical studies, an LC–MS/MS method with LLOQ of 0.1 ng/mL, was developed and validated in human plasma by using the formate adduct as the precursor ion. Formic acid (0.01%) in water and acetonitrile was found to be the most favorable mobile phases for both deprotonated and formate adduct ions in negative electrospray ionization mode. A combination of a 3M Empore™ C18 plate for SPE and a Waters Atlantis dC18 analytical column for separation was used to achieve a highly selective solid phase extraction and chromatographic procedure from plasma without dry down and reconstitution steps. In the development of an assay for BMS-708163 in cerebral spinal fluid (CSF), significant non-specific binding of BMS-708163 was observed and resolved with pre- or post-spike of 0.2% Tween 20 into CSF samples. A dilute-and-shoot LC–MS/MS method with LLOQ of 0.1 ng/mL was developed and validated to assess BMS-708163 exposure in human CSF.  相似文献   

4.
A rapid and specific LC–MS/MS based bioanalytical method was developed and validated for the determination of 18-(p-iodophenyl)octadecyl phosphocholine (CLR1401), a novel phosphocholine drug candidate, in rat plasma. The optimal chromatographic behavior of CLR1401 was achieved on a Kromasil silica column (50 mm × 3 mm, 5 μm) under hydrophilic interaction chromatography. The total LC analysis time per injection was 2.8 min with a flow rate of 1.5 mL/min under gradient elution. Liquid–liquid extraction in a 96-well format using ethyl acetate was developed and applied for method validation and sample analysis. The method validation was conducted over the curve range of 2.00–1000 ng/mL using 0.0500 mL of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed ≤ 5.9% relative standard deviation (RSD) and −10.8 to −1.4% relative error (RE). The method was successfully applied to determine the toxicokinetics of CLR1401 in rats from three dose groups of 0.4, 4.0, and 10.0 mg/kg/day via intravenous administration.  相似文献   

5.
A fast and sensitive HPLC–APCI-MS/MS method was developed for the determination of ergosta-4,6,8(14),22-tetraen-3-one (ergone) in rat plasma. The plasma sample containing ergone and ergosterol (internal standard) were simply treated with acetone to precipitate and remove proteins and the isolated supernatants were directly injected into the HPLC–APCI-MS/MS system. Chromatographic separation was performed on a 1.8 μm Zorbax SB-C18 column (100 mm × 3.0 mm) with a 97:3 (v/v) mixed solution of methanol and 0.1% aqueous formic acid being used as mobile phase. Quantification was performed by multiple selected reactions monitoring (MRM) of the transitions with (m/z)+ 393–268 for ergone and (m/z)+ 379–69 for the IS. The method was validated in the concentration range of 5–1600 ng/mL for ergone. The precision of the assay (RSD%) was less than 10.5% at all concentrations levels within the tested range and adequate accuracy, and the limit of detection was 1.5 ng/mL. The absolute recoveries of both ergone and ergosterol from the plasma were more than 95%. The developed method has been successfully applied to the pharmacokinetic study of the drug in SD rats.  相似文献   

6.
A precise and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for simultaneous determination of vinpocetine (VP) and its primary metabolite, apovincaminic acid (AVA), in rat plasma was developed and validated. The analytes and the internal standard-dimenhydrinate were extracted from 50 μL aliquots of rat plasma via solid–liquid extraction. Chromatographic separation was achieved in a run time of 3.5 min on a C18 column under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for VP, AVA and IS were m/z 351.4 → 280.2, 323.2 → 280.2 and 256.2 → 167.3 respectively. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect, stability study and dilution integrity. A linear dynamic range of 0.5–500 ng/mL for both VP and AVA was evaluated with mean correlation coefficient (r) of 0.9970 and 0.9984 respectively. The precision of the assay (RSD%) was less than 8.55% at all concentrations levels for both VP and AVA. This method was successfully applied to a pharmacokinetic study of VP in rats after intravenous (1 mg/kg) and oral (1 mg/kg) administration.  相似文献   

7.
A rapid and sensitive liquid chromatography–electrospray ionization tandem mass spectrometry method (LC–ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis® HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 μL mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm × 150 mm, 5 μm, AQ type) column with a gradient elution of solvent A (0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 μL/min. The LC–MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor–product ion transitions consisted of m/z 635.7 → m/z 607.5 for goserelin and m/z 424.0 → m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra- and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1–20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL. Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits.  相似文献   

8.
We have developed a gas chromatography–high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography–high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.  相似文献   

9.
A simple and sensitive HPLC method was established and validated for the determination of docetaxel (DTX) in rabbit plasma. Biosamples were spiked with paclitaxel (PCX) as an internal standard (I.S.) and pre-treated by solid-phase extraction (SPE). The SPE procedure followed a simple protein digestion was based on nylon6 electrospun nanofibers mats as sorbents. Under optimized conditions, target analytes in 500 μL of plasma sample can be completely extracted by only 2.5 mg nylon6 nanofibers mat and eluted by 100 μL solvent. The HPLC separation was obtained on C18 column and UV detector was used to quantify the target analytes. The extraction recovery was more than 85%; the standard curve was linear over the validated concentrations range of 10–5000 ng/mL and the limit of detection was 2 ng/mL. The inter-day coefficient of variation (CV%) of the calibration standards was below 5.0% and the mean accuracy was in the range of 92.8–113.4%. Moreover, analysing quality control plasma samples in 3 days, the results showed that the method was precise and accurate, for the intra- and inter-day CV% within 10% and the accuracy from 96.0% to 114.0%. The developed and validated method was successfully applied to relative bioavailability study for the preclinical evaluation of a new injectable DTX–sulfobutyl ether beta-cyclodextrin (DTX–SBE-β-CD) inclusion complex freeze-dried powder (test preparation), compared with the reference preparation (DTX injection, Taxotere®) in healthy rabbits. On the basis of the mean AUC(0–t) and AUC(0–infinity), the relative bioavailability of the test preparation was found to be 113.1%.  相似文献   

10.
A highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of forsythiaside in rat plasma using epicatechin as internal standard. The analytes were extracted by solid-phase extraction and chromatographied on a C18 column eluted with a gradient mobile phase of acetonitrile and water both containing 0.2% formic acid. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 623 → 161 and m/z 289 → 109 for forsythiaside and epicatechin, respectively. The assay was linear over the concentration ranges of 2.0–50.0 and 50.0–5000.0 ng/mL with limits of detection and quantification of 0.2 and 1.0 ng/mL, respectively. The precision was <10.8% and the accuracy was >91.9%, and extraction recovery ranged from 81.3% to 85.0%. This method was successfully applied to a pharmacokinetic study of forsythiaside in rats after intravenous (20 mg/kg) and oral (100 mg/kg) administration, and the result showed that the compound was poorly absorbed with an absolute bioavailability being approximately 0.5%.  相似文献   

11.
Rapid and sensitive analytical methods using liquid chromatography with tandem mass spectrometry (LC/MS/MS) were developed for the determination of ticagrelor, the first reversible oral platelet P2Y12 receptor inhibitor, and its metabolites AR-C124910XX and AR-C133913XX in human plasma. Ticagrelor and its metabolites were extracted using protein precipitation with acetonitrile. Chromatographic separations were performed on reversed phase columns and detection using atmospheric pressure chemical ionization (APCI). Ticagrelor and AR-C124910XX were analyzed in the same assay, with the internal standard, d7-ZD6140, on a C18 column using negative ionization; AR-C133913XX analyzed separately on a phenyl column using positive ionization. Full validation of the methods was performed including selectivity, lower limit of quantification, accuracy, precision stability and incurred sample reproducibility and incurred sample stability. Total analytical run time was short (2 min). Calibration curves were established in the range 5–5000 ng/mL for ticagrelor, 2.5–2500 ng/mL for AR-C124910XX and 2–1000 ng/mL for AR-C133913XX. Lower limits of quantification for ticagrelor, AR-C124910XX and AR-C133913XX were determined to be 5, 2.5 and 2.0 ng/mL, respectively from 100 μL of human plasma. For ticagrelor, AR-C124910XX and AR-C133913XX, mean intra-batch accuracy was 91.9–109.0%, 86.8–109.2% and 100.5–112.0%, respectively; intra-batch precision was 4.0–8.4%, 5.2–16.9% and 3.9–12.3%, respectively. The methods were also applied to quantification of ticagrelor, AR-C124910XX and AR-C133913XX in rabbit, rat, mouse and marmoset, using 25 μL of animal plasma. A modified methodology was developed to quantify ticagrelor and AR-C124910XX in plasma from dog and cynomolgus monkey. Human incurred samples were found to generate consistent reproducibility and stability results. This method was successfully applied to determine plasma concentrations following administration of ticagrelor in human volunteers and patients, and animal safety evaluation studies. This validated methods has the advantages of being straightforward, robust and allows a fast throughput of samples.  相似文献   

12.
Determination of estrogens in plasma is important in evaluation of effects of some anticancer drugs, such as aromatase inhibitors. However, as reported previously, high performance liquid chromatography–radio immunoassay (HPLC–RIA) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) with chemical derivatization require complicated sample preparation. In this study, a highly sensitive and simple method for determination of estrone (E1), 17β-estradiol (E2) and estrone 3-sulfate (E1S) in human plasma has been developed. Following diethylether extraction from plasma, analytes were purified by immunosorbents and then determined by LC–MS/MS using electrospray ionization (ESI). Immunosorbents were prepared by immobilization of specific antibodies raised against each analyte onto solid support. Use of selective immunosorbents in sample preparation removed interference in plasma samples that would cause ionization suppression, and markedly improved the sensitivity of LC–MS/MS for these analytes, without derivatization. Calibration curves of each analyte showed good linearity and reproducibility over the range of 0.05–50 pg/injection for E1, 0.2–50 pg/injection for E2 and 0.05–300 pg/injection for E1S, respectively. The mean values of lower limits of quantification (LLOQ) in human plasma corrected by recovery of deuterated estrogens (internal standard, I.S.) were 0.1892 pg/mL for E1, 0.7064 pg/mL for E2 and 0.3333 pg/mL for E1S, respectively. These LLOQ values were comparable to those previous reported using HPLC–RIA and LC–MS/MS. Using this method, the normal levels of three estrogens in healthy female plasma (n = 5) were determined. The mean values of E1, E2 and E1S were 38.0 pg/mL (range 24.8–53.0), 34.3 pg/mL (22.6–46.6) and 786 pg/mL (163–2080), respectively. The immunoaffinity LC–MS/MS described here allows sensitive and accurate quantification of E1, E2 and E1S without laborious sample preparation.  相似文献   

13.
The steroidal liver X receptor agonist, 3α,6α,24-trihydroxy-24,24-di(trifluoromethyl)-5β-cholane (ATI-829) is a potential therapeutic agent for the treatment of atherosclerosis. A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the quantification of ATI-829 in mouse plasma was developed and validated. Proteins in a 25 μL aliquot of mouse plasma were precipitated, and ATI-829 was extracted from the precipitate by the addition of 125 μL methanol. The overall extraction efficiency was greater than 99%. LC–MS–MS with negative ion electrospray and selected reaction monitoring was used for the quantitative analysis of ATI-829. The lower limit of quantitation of ATI-829 corresponded to 5.0 ng/mL (9.7 nM) plasma. Interference from matrix was negligible. The calibration curve was linear over the range 5–2000 ng/mL. The intra-day precision and inter-day precision of the analyses were <4.5% and <6%, respectively, and the accuracy ranged from 92% to 103%. ATI-829 in plasma was stable for at least 6 h at room temperature, 1 week at 4 °C, and 3 weeks at −20 °C. The validated method was then utilized for pharmacokinetic studies of ATI-829 administered to mice.  相似文献   

14.
A method for simultaneous bioanalysis of the three cytotoxic drugs cytosine arabinoside, daunorubicin and etoposide in human plasma was developed and validated. A HPLC method with ultra-violet and fluorescence detection, preceded by mixed-mode cation-exchange solid phase extraction sample preparation, was used for the quantification of the analytes. The assay was used for the simultaneous measurement of cytosine arabinoside, daunorubicin and etoposide with linearity in the ranges of 13–1500 ng/mL, 15–1000 ng/mL and 52.5–3500 ng/mL, respectively. The chromatographic run-time was 15.5 min. The overall precision (% relative standard deviation) was within 0.2–13.5% and the recovery ranged between 86.1% and 110.1% for the three drugs at all concentrations tested. Plasma samples were stable for at least two months when stored at −20 °C. The method was successfully applied to quantification of the three drugs in blood samples from patients undergoing induction treatment for acute myeloid leukaemia, thus demonstrating its suitability for clinical studies.  相似文献   

15.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   

16.
A rapid, specific, and sensitive method utilizing reversed-phase ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed and validated to determine finasteride levels in human plasma. The plasma samples were prepared by liquid–liquid extraction with ethyl acetate, evaporation, and reconstitution. MS/MS analyses were performed on a triple–quadrupole tandem mass spectrometer by monitoring protonated parent → daughter ion pairs at m/z 373 → 305 for finasteride and m/z 237 → 194 for carbamazepine (internal standard, IS). The method was validated with respect to linearity, recovery, specificity, accuracy, precision, and stability. The method exhibited a linear response from 0.1 to 30 ng/mL (r2 > 0.998). The limit of quantitation for finasteride in plasma was 0.1 ng/mL. The relative standard deviation (RSD) of intra- and inter-day measurements was less than 15% and the method was accurate within −6.0% to 2.31% at all quality-control levels. The mean extraction recovery was higher than 83% for finasteride and 84% for the IS. Plasma samples containing finasteride were stable under the three sets of conditions tested and the processed samples were stable up to 29 h in an autosampler at 5 °C. Detection and quantitation of both analytes within 3 min make this method suitable for high-throughput analyses. The method was successfully applied to a pharmacokinetic study of finasteride in healthy volunteers following oral administration.  相似文献   

17.
A novel, sensitive and reliable liquid chromatography–tandem mass spectrometric (LC–MS/MS) method was developed and validated for the determination of belinostat (PXD101) in human plasma. Oxamflatin was used as the internal standard. Liquid–liquid extraction of the plasma sample was performed using tert-butyl methyl ether as the organic solvent. Chromatographic separation was achieved on a BDS Hypersil C18 column (2.1 mm × 100 mm, 5 μm) using gradient elution mode using 0.05% formic acid in water and 0.05% formic acid in acetonitrile as solvents A and B, respectively, 60/40. The run time was 6 min. The mass spectrometer was operated under a positive electrospray ionization condition and a multiple reaction monitoring mode. An excellent linear calibration was achieved in the range of 0.5–1000 ng/mL. An average recovery of belinostat for four quality controls was 72.6% and the recovery of the internal standard at 1000 ng/mL was 67.8%. The intra-day and inter-day precisions for belinostat were ≤8.0 and ≤10.3%, respectively, and their accuracy ranged from 100.2 to 106.7%. No significant matrix effect was identified. In analysis of patient samples, belinostat glucuronide was identified and baseline separated from belinostat. This well-validated assay has been applied for quantification of belinostat in plasma samples within 24 h after the start of infusion for Asian hepatocellular carcinoma patients in a dose escalation study.  相似文献   

18.
Simple, sensitive and robust liquid chromatography–tandem mass spectrometer (LC–MS/MS) methods were developed and validated for the determination of lipopeptide polymyxins and glycopeptide vancomycin in rat plasma. The effect of trichloroacetic acid (TCA) concentration on sample recoveries (peak area of sample recovered from plasma/peak area of sample from neat solvent solutions) was studied and an optimized concentration of 30% TCA were determined that gives the best sample recovery for the peptides from rat plasma. The effect of the TCA concentration on the chromatographic behavior of peptides was studied on a Phenomenex Jupiter C18 5 μ 300 Å 50 mm × 2 mm column using a mobile phase with a pH of 2.8. Other than protein precipitation, TCA also acted as ion pairing reagent and was only present in the samples but not in the mobile phases. The data demonstrated that by increasing the TCA concentration, the analyte retention and sensitivity were improved. The absence of TCA in mobile phase helped to reduce the ion source contamination and to achieve good reproducibility. The plasma method was linearly calibrated from 5 to 5000 ng/mL for polymyxins with precisions to be of 2.3–10.8%, and accuracies to be 91.7–107.4% for polymyxin B1, B2, E1, E2, respectively. For vancomycin the calibration is from 1 to 5000 ng/mL with precisions to be of 7.8–10.3 and accuracies to be 96.2–102.0%. The LLOQs corresponding with a coefficient of variation less than 20% were 7.5, 18.1, 7.3, 5.0 and 1.0 ng/mL for polymyxin B1, B2, E1, E2 and vancomycin, respectively.  相似文献   

19.
Amphetamines are a group of sympathomimetic drugs that exhibit strong central nervous system stimulant effects. d-Amphetamine ((+)-alpha-methylphenetylamine) is the parent drug in this class to which all others are structurally related. In drug discovery, d-amphetamine is extensively used either for the exploration of novel mechanisms involving the catecholaminergic system, or for the validation of new behavioural animal models. Due to this extensive use of d-amphetamine in drug research and its interest in toxicologic–forensic investigation, a specific and high-throughput method, with minimal sample preparation, is necessary for routine analysis of d-amphetamine in biological samples. We propose here a sensitive, specific and high-throughput bioanalytical method for the quantitative determination of d-amphetamine in rat blood using MS3 scan mode on a hybrid triple quadrupole-linear ion trap mass spectrometer (LC–MS/MS/MS). Blood samples, following dilution with water, were prepared by fully automated protein precipitation with acetonitrile containing an internal standard. The chromatographic separation was achieved on a Waters XTerra C18 column (2.1 mm × 30 mm, 3.5 μm) using gradient elution at a flow rate of 1.0 mL/min over a 2 min run time. An Applied Biosystems API4000 QTRAP™ mass spectrometer equipped with turbo ion-spray ionization source was operated simultaneously in MS3 scan mode for the d-amphetamine and in multiple reaction monitoring (MRM) for the internal standard. The MS/MS/MS ion transition monitored was m/z 136.1 → 119.1 → 91.1 for the quantitation of d-amphetamine and for the internal standard (rolipram) the MS/MS ion transition monitored was m/z 276.1 → 208.2. The linear dynamic range was established over the concentration range 0.5–1000 ng/mL (r2 = 0.9991). The method was rugged and sensitive with a lower limit of quantification (LLOQ) of 0.5 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. This method was successfully applied to evaluate the pharmacokinetics of d-amphetamine in rat. On a more general extent, this work demonstrated that the selectivity of the fragmentation pathway (MS3) can be used as alternative approach to significantly improve detection capability in complex situation (e.g., small molecules in complex matrices) rather than increasing time for sample preparation and chromatographic separation.  相似文献   

20.
The present study aims at developing a simple, sensitive and specific liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the quantification of pantoprazole sodium (PS) in human plasma using pantoprazole D3 (PSD3) as internal standard (IS). Chromatographic separation was performed on Zorbax SB-C18, 4.6 mm × 75 mm, 3.5 μm, 80 Å column with an isocratic mobile phase composed of 10 mM ammonium acetate (pH 7.10): acetonitrile (30:70, v/v), pumped at 0.6 mL/min. PS and PSD3 were detected with proton adducts at m/z 384.2 → 200.1 and 387.1 → 203.1 in multiple reaction monitoring (MRM) positive mode, respectively. Precipitation method was employed in the extraction of PS and PSD3 from the biological matrix. This method was validated over a linear concentration range of 10.00–3000.00 ng/mL with correlation coefficient (r) ≥ 0.9997. Intra- and inter-day precision of PS were found to be within the range of 1.13–1.54 and 1.76–2.86, respectively. Both analytes were stable throughout freeze/thaw cycles, bench top and postoperative stability studies. This method was successfully utilized in the analysis of blood samples following oral administration of PS (40 mg) in healthy human volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号