首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   

2.
An enantioselective and sensitive method was developed and validated for determination of doxazosin enantiomers in human plasma by liquid chromatography–tandem mass spectrometry. The enantiomers of doxazosin were extracted from plasma using ethyl ether/dichloromethane (3/2, v/v) under alkaline conditions. Baseline chiral separation was obtained within 9 min on an ovomucoid column using an isocratic mobile phase of methanol/5 mM ammonium acetate/formic acid (20/80/0.016, v/v/v) at a flow rate of 0.60 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 452 → 344 for doxazosin enantiomers, and m/z 384 → 247 for prazosin (internal standard). The method was linear in the concentration range of 0.100–50.0 ng/mL for each enantiomer using 200 μL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.100 ng/mL. The intra- and inter-assay precision was 5.0–11.1% and 5.7–7.6% for R-(−)-doxazosin and S-(+)-doxazosin, respectively. The accuracy was 97.4–99.5% for R-(−)-doxazosin and 96.8–102.8% for S-(+)-doxazosin. No chiral inversion was observed during the plasma storage, preparation and analysis. The method proved adequate for enantioselective pharmacokinetic studies of doxazosin after oral administration of therapeutic doses of racemic doxazosin.  相似文献   

3.
A rapid and sensitive liquid chromatography–electrospray ionization tandem mass spectrometry method (LC–ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis® HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 μL mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm × 150 mm, 5 μm, AQ type) column with a gradient elution of solvent A (0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 μL/min. The LC–MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor–product ion transitions consisted of m/z 635.7 → m/z 607.5 for goserelin and m/z 424.0 → m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra- and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1–20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL. Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits.  相似文献   

4.
A sensitive, selective and high throughput liquid chromatography tandem mass spectrometry (LC–ESI-MS/MS) method has been developed for the determination of teriflunomide, an active metabolite of leflunomide in human plasma. Plasma samples were prepared by liquid–liquid extraction of teriflunomide and valsartan as internal standard (IS) in ethyl acetate from 200 μL human plasma. The chromatographic separation was achieved on an Inertsil ODS-3 C18 (50 mm × 4.6 mm, 3 μm) analytical column using isocratic mobile phase, consisting of 20 mM ammonium acetate–methanol (25:75, v/v), at a flow-rate of 0.8 mL/min. The precursor → product ion transition for teriflunomide (m/z 269.0 → 82.0) and IS (m/z 434.1 → 350.3) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and negative ion mode. The method was validated over a wide dynamic concentration range of 10.1–4001 ng/mL. Matrix effect was assessed by post-column infusion experiment and the mean process efficiency were 91.7% and 88.2% for teriflunomide and IS respectively. The method was rugged and rapid with a total run time of 2.0 min and is applied to a bioequivalence study of 20 mg leflunomide (test and reference) tablet formulation in 12 healthy Indian male subjects under fasting condition.  相似文献   

5.
A sensitive and accurate method for determination of bicyclol in dog plasma was developed. Thermo Scientific TSQ Quantum triple quadrupole system with multiple ion monitoring (MIM) positive scanning mode was applied. Bicyclol and DDB (IS) sodium adduct molecular ions were monitored at m/z 413 and m/z 441 in both Q1 and Q3, respectively. The collision energy in Q2 was set to 15 eV. Precipitation method was employed in the extraction of bicyclol and DDB from the biological matrix. The method was validated over 1–500 ng/mL for bicyclol. The recovery was 96.5–109.5%, and the limit of quantitation (LOQ) detection was 1 ng/mL for bicyclol. The intra- and inter-day precision of the method at three concentrations was 3.3–14.3% with accuracy of 99.9–109.0%. The method was successfully applied to bioequivalence studies of bicyclol controlled-release formulation to obtain the pharmacokinetic parameters.  相似文献   

6.
A rapid, specific, and sensitive method utilizing reversed-phase ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed and validated to determine finasteride levels in human plasma. The plasma samples were prepared by liquid–liquid extraction with ethyl acetate, evaporation, and reconstitution. MS/MS analyses were performed on a triple–quadrupole tandem mass spectrometer by monitoring protonated parent → daughter ion pairs at m/z 373 → 305 for finasteride and m/z 237 → 194 for carbamazepine (internal standard, IS). The method was validated with respect to linearity, recovery, specificity, accuracy, precision, and stability. The method exhibited a linear response from 0.1 to 30 ng/mL (r2 > 0.998). The limit of quantitation for finasteride in plasma was 0.1 ng/mL. The relative standard deviation (RSD) of intra- and inter-day measurements was less than 15% and the method was accurate within −6.0% to 2.31% at all quality-control levels. The mean extraction recovery was higher than 83% for finasteride and 84% for the IS. Plasma samples containing finasteride were stable under the three sets of conditions tested and the processed samples were stable up to 29 h in an autosampler at 5 °C. Detection and quantitation of both analytes within 3 min make this method suitable for high-throughput analyses. The method was successfully applied to a pharmacokinetic study of finasteride in healthy volunteers following oral administration.  相似文献   

7.
A high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS–MS) method, using back-flush column-switching was developed for total drug concentrations of ropivacaine in serum and drainage blood in the measuring range 0.1–10 μg/mL. Samples were diluted with internal standard (2H7-ropivacaine) and extraction buffer, centrifuged and injected directly onto a BioTrap 500 MS extraction column. Using a time programmed six-port valve switch, ropivacaine was back-flushed onto a Zorbax SB-Aq analytical column, gradient eluted and finally detected after electro spray ionisation and multiple reaction monitoring (MRM) of the transitions m/z 275 → m/z 126 and m/z 282 → m/z 133 for ropivacaine and 2H7-ropivacaine, respectively. Accuracy (bias-%) was −1.5 to 5.8% and intermediate precision (C.V.) was 1.4–3.1%. The low sample amount required (10 μL), high specificity and short run time (6 min) makes it very suitable for determination of ropivacaine. Using the same methodology as described above and 200 μL ultrafiltrate, the free drug concentrations of ropivacaine in serum could be precisely determined with a C.V. below 3%. The method was used to investigate the safety of reinfusion of drainage blood after knee and hip arthroplasty when ropivacaine (Naropin®) was used for local analgesia. Data for 30 patients are summarised.  相似文献   

8.
A rapid, sensitive and specific method for the determination of cepharanthine in human plasma using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC–MS/MS) was described. Cepharanthine and the internal standard (I.S.), telmisartan, were extracted from human plasma by methanol to precipitate the protein. A centrifuged upper layer was then evaporated and reconstituted with 100 μL methanol. Chromatographic separation was performed on an AGILENT XDB-C8 column (150 mm × 2.1 mm, 5.0 μm, Agilent, USA) using a gradient mobile phase with 1 mmol/L ammonium acetate in water with 0.05% formic acid and methanol. Detection and quantitation was performed by MS/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the positive ion mode. The most intense [M+H]+ MRM transition of cepharanthine at m/z 607.3 → 365.3 was used for quantitation and the transition at m/z 515.5 → 276.4 was used to monitor telmisartan. The calibration curve was linear within the concentration range of 0.5–200.0 ng/mL (= 0.9994). The limit of quantification (LOQ) was 0.5 ng/mL. The extraction recovery was above 81.1%. The accuracy was higher than 92.3%. The intra- and inter-day precisions were less than 9.66%. The method was accurate, sensitive and simple and was successfully applied to a pharmacokinetic study after single intravenous administration of 50 mg cepharanthine in 12 healthy Chinese volunteers.  相似文献   

9.
A rapid, sensitive and simple high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was developed for determination of cefazedone in human plasma using metronidazole as internal standard (IS). The chromatographic separation was achieved on an Ultimate XB-CN column (2.1 mm × 150 mm, 5 μm) with an isocratic mobile phase of acetonitrile and 20 mM ammonium acetate in 0.1% formic acid in water (15:85, v/v). Detection was performed using electrospray ionization in positive ion multiple reaction-monitoring mode (SRM), monitoring the transitions m/z 548.2 → 344.1 for cefazedone and m/z 172.2 → 128.1 for IS. Calibration curves were linear over a wide range of 0.20–401.12 μg/mL for cefazedone in plasma. The lower limit of quantification (LLOQ) was 0.20 μg/mL. The intra- and inter-day precisions were less than 7.2%. The average recovery of cefazedone was 90.8–91.0%. The validated method was successfully applied to the pharmacokinetic study of cefazedone in Chinese healthy volunteers following intravenous (IV) administration of 500, 1000 and 2000 mg cefazedone injection.  相似文献   

10.
A sensitive and accurate ultra-performance liquid chromatography electrospray ionization tandem mass spectrometry (UPLC–ESI-MS/MS) method was developed and validated for the simultaneous determination of vitexin-4″-O-glucoside (VGL), vitexin-2″-O-rhamnoside (VRH), rutin (RUT) and vitexin (VIT) in rat plasma after intravenous administration of hawthorn leaves flavonoids (HLF). Following protein precipitation by methanol, the analytes were separated on an ACQUITY UPLC BEH C18 column packed with 1.7 μm particles by gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.20 mL/min. The analytes and diphenhydramine (internal standard, IS) were detected in the multiple reaction monitoring (MRM) mode by means of an electrospray ionization (ESI) interface (m/z 292.96 for vitexin-4″-O-glucoside, m/z 293.10 for vitexin-2″-O-rhamnoside, m/z 299.92 for rutin, m/z 310.94 for vitexin and m/z 166.96 for IS). The calibration curve was linear over the range 10–40,000 ng/mL for vitexin-4″-O-glucoside, 10–50,000 ng/mL for vitexin-2″-O-rhamnoside, 8–1000 ng/mL for rutin and 16–2000 ng/mL for vitexin. The intra- and inter-run precisions (relative standard deviation, RSD) of these analytes were all within 15% and the accuracy (the relative error, RE) ranged from −10% to 10%. The stability experiment indicated that the four analytes in rat plasma samples and plasma extracts under anticipated conditions were stable. The developed method was applied for the first time to pharmacokinetic studies of the four bioactive compounds of hawthorn leaves flavonoids following a single intravenous administration of 20 mg/kg in rats.  相似文献   

11.
A method for the quantitative analysis of cudratricusxanthone B (CXB) in rat plasma by high performance liquid chromatography–electrospray ionization-tandem mass spectrometry (HPLC–ESI-MS/MS) has been developed and validated. The method involved liquid–liquid extraction from plasma, simple chromatographic conditions on a Venusil XBP-PH C18 column with the mobile phase of 0.5% formic acid in methanol, and mass spectrometric detection using an API-3000 instrument. Multiple reaction monitoring (MRM) mode was used to monitor precursor/product ion transitions of m/z 397.1/285.0 for CXB and m/z 381.6/269.2 for the internal standard (I.S.) cudraxanthone H. The standard curves were linear over the concentration range of 1–500 ng/mL for CXB in rat plasma. The intra- and inter-batch accuracy for CXB at four concentrations was 89.4–99.5% and 89.4–100.8%, respectively. The RSDs were less than 7.92%. The lower limit of quantification for CXB was 1.0 ng/mL using 100 μL of plasma. The average extraction recoveries of CXB ranged from 80.1 to 95.4% at the concentrations of 2, 50 and 500 ng/mL, respectively. This method was successfully applied to the pharmacokinetic study after an intravenous administration of CXB in male Sprague–Dawley (SD) rats.  相似文献   

12.
A precise and sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for simultaneous determination of vinpocetine (VP) and its primary metabolite, apovincaminic acid (AVA), in rat plasma was developed and validated. The analytes and the internal standard-dimenhydrinate were extracted from 50 μL aliquots of rat plasma via solid–liquid extraction. Chromatographic separation was achieved in a run time of 3.5 min on a C18 column under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for VP, AVA and IS were m/z 351.4 → 280.2, 323.2 → 280.2 and 256.2 → 167.3 respectively. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect, stability study and dilution integrity. A linear dynamic range of 0.5–500 ng/mL for both VP and AVA was evaluated with mean correlation coefficient (r) of 0.9970 and 0.9984 respectively. The precision of the assay (RSD%) was less than 8.55% at all concentrations levels for both VP and AVA. This method was successfully applied to a pharmacokinetic study of VP in rats after intravenous (1 mg/kg) and oral (1 mg/kg) administration.  相似文献   

13.
A simple offline LC–MS/MS method for the quantification of sitagliptin in human plasma is described. Samples are prepared using protein precipitation. Filtration of the supernatants through a Hybrid-SPE-PPT plate was found to be necessary to reduce ionization suppression caused by co-elution of phospholipids with sitagliptin. The sitagliptin and its stable isotope labeled internal standard (IS) were chromatographed under hydrophilic interaction chromatography conditions on a Waters Atlantis HILIC Silica column (2.1 mm × 50 mm, 3 μm) using a mobile phase of ACN/H2O (80/20, v/v) containing 10 mM NH4Ac (pH 4.7). The sample drying after protein precipitation due to high organic content in the sample is not necessary, because HILIC column was used. The analytes were detected with a tandem mass spectrometer employing a turbo ion spray (TIS) interface in positive ionization mode. The multiple reaction monitoring (MRM) transitions were m/z 408 → 235 for sitagliptin and m/z 412 → 239 for IS. The lower limit of quantitation (LLOQ) for this method is 1 ng/mL when 100 μL of plasma is processed. The linear calibration range is 1–1000 ng/mL for sitagliptin. Intra-day precision and accuracy were assessed based on the analysis of six sets of calibration standards prepared in six lots of human control plasma. Intra-day precision (RSD%, n = 6) ranged from 1.2% to 6.1% and the intra-day accuracy ranged from 97.6% to 103% of nominal values.  相似文献   

14.
The present study aims at developing a simple, sensitive and specific liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the quantification of pantoprazole sodium (PS) in human plasma using pantoprazole D3 (PSD3) as internal standard (IS). Chromatographic separation was performed on Zorbax SB-C18, 4.6 mm × 75 mm, 3.5 μm, 80 Å column with an isocratic mobile phase composed of 10 mM ammonium acetate (pH 7.10): acetonitrile (30:70, v/v), pumped at 0.6 mL/min. PS and PSD3 were detected with proton adducts at m/z 384.2 → 200.1 and 387.1 → 203.1 in multiple reaction monitoring (MRM) positive mode, respectively. Precipitation method was employed in the extraction of PS and PSD3 from the biological matrix. This method was validated over a linear concentration range of 10.00–3000.00 ng/mL with correlation coefficient (r) ≥ 0.9997. Intra- and inter-day precision of PS were found to be within the range of 1.13–1.54 and 1.76–2.86, respectively. Both analytes were stable throughout freeze/thaw cycles, bench top and postoperative stability studies. This method was successfully utilized in the analysis of blood samples following oral administration of PS (40 mg) in healthy human volunteers.  相似文献   

15.
A rapid, simple and sensitive HPLC–ESI–MS/MS method was developed for the simultaneous determination of capsaicin and dihydrocapsaicin in rat plasma. Plasma samples containing capsaicin, dihydrocapsaicin and phenacetin (internal standard) were prepared based on a simple protein precipitation by the addition of two volumes of acetonitrile. The analytes and internal standard were separated on a Zorbax SB-C18 column (3.5 μm, 2.1 mm × 100 mm) with mobile phase of acetonitrile/water (55:45, v/v) containing 0.1% formic acid (v/v) at a flow rate of 0.2 mL/min with an operating temperature of 25 °C. Quantification was performed on a triple quadrupole mass spectrometer equipped with electrospray ionization (ESI) source by selected reaction monitoring (SRM) of the transitions at m/z 306–137 for capsaicin, m/z 308–137 for dihydrocapsaicin and m/z 180–110 for the IS. Linear detection responses were obtained for capsaicin and dihydrocapsaicin ranging from 1 to 500 ng/mL and the lower limits of quantitation (LLOQs) for the two compounds were 1 ng/mL. The intra- and inter-day precisions (R.S.D.%) were within 9.79% for the two analytes, while the deviations of assay accuracies were within ±10.63%. The average recoveries of the analytes were greater than 89.88%. The analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic studies of capsaicin and dihydrocapsaicin in rats after subcutaneous administration of capsaicin (natural, containing 65% capsaicin and 35% dihydrocapsaicin).  相似文献   

16.
A sensitive and specific liquid chromatography–electrospray ionization-mass spectrometry (LC–ESI-MS/MS) method has been developed and validated for the identification and quantification of clebopride in human plasma using itopride as an internal standard. The method involves a simple liquid–liquid extraction. The analytes were separated by isocratic gradient elution on a CAPCELL MG-III C18 (5 μm, 150 mm × 2.1 mm i.d.) column and analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H]+ ions, m/z 373.9 → m/z184.0 for clebopride, m/z 359.9 → m/z71.5 for itopride. The method was validated over the concentration range of 69.530–4450.0 pg/ml for clebopride. Within- and between-batch precision (RSD%) was all within 6.83% and accuracy ranged from −8.16 to 1.88%. The LLOQ was 69.530 pg/ml. The extraction recovery was on an average 77% for clebopride. The validated method was used to study the pharmacokinetics profile of clebopride in human plasma after oral administration of clebopride.  相似文献   

17.
Amphetamines are a group of sympathomimetic drugs that exhibit strong central nervous system stimulant effects. d-Amphetamine ((+)-alpha-methylphenetylamine) is the parent drug in this class to which all others are structurally related. In drug discovery, d-amphetamine is extensively used either for the exploration of novel mechanisms involving the catecholaminergic system, or for the validation of new behavioural animal models. Due to this extensive use of d-amphetamine in drug research and its interest in toxicologic–forensic investigation, a specific and high-throughput method, with minimal sample preparation, is necessary for routine analysis of d-amphetamine in biological samples. We propose here a sensitive, specific and high-throughput bioanalytical method for the quantitative determination of d-amphetamine in rat blood using MS3 scan mode on a hybrid triple quadrupole-linear ion trap mass spectrometer (LC–MS/MS/MS). Blood samples, following dilution with water, were prepared by fully automated protein precipitation with acetonitrile containing an internal standard. The chromatographic separation was achieved on a Waters XTerra C18 column (2.1 mm × 30 mm, 3.5 μm) using gradient elution at a flow rate of 1.0 mL/min over a 2 min run time. An Applied Biosystems API4000 QTRAP™ mass spectrometer equipped with turbo ion-spray ionization source was operated simultaneously in MS3 scan mode for the d-amphetamine and in multiple reaction monitoring (MRM) for the internal standard. The MS/MS/MS ion transition monitored was m/z 136.1 → 119.1 → 91.1 for the quantitation of d-amphetamine and for the internal standard (rolipram) the MS/MS ion transition monitored was m/z 276.1 → 208.2. The linear dynamic range was established over the concentration range 0.5–1000 ng/mL (r2 = 0.9991). The method was rugged and sensitive with a lower limit of quantification (LLOQ) of 0.5 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. This method was successfully applied to evaluate the pharmacokinetics of d-amphetamine in rat. On a more general extent, this work demonstrated that the selectivity of the fragmentation pathway (MS3) can be used as alternative approach to significantly improve detection capability in complex situation (e.g., small molecules in complex matrices) rather than increasing time for sample preparation and chromatographic separation.  相似文献   

18.
A sensitive and rapid HTLC–ESI-MS/MS method with an advanced online sample preparation was developed for determination of the γ-secretase inhibitor MK-0752 in human plasma using an internal standard. Plasma samples (100 μL) were diluted and injected directly onto an online extraction column (Cohesive Cyclone MAX 0.5 mm × 50 mm, >30 μm), the sample matrix was washed out with an aqueous solution, and retained analytes were eluted out and transferred directly to the analytical column (Phenomenex Gemini 3μ C18 110A, 50 mm × 2.0 mm at 50 °C) for separation using a gradient mobile phase. The eluted analytes were then detected on an API-3000 LC–MS/MS System with ESI and a negative multiple reaction monitoring mode. The monitored ion transitions were m/z 441 → 175 for MK-0752 and 496 → 175 for the internal standard. Online extraction recoveries were 81%. The method was validated and was linear in the range of 0.05–50 μg/mL. Within-day and between-day precisions were < 8.6%, and accuracies were 0.7 and 7.1%. This method was applied to the measurement of plasma MK-0752 levels in a Phase I study of pediatric patients with recurrent or refractory brain tumors.  相似文献   

19.
A fast and sensitive HPLC–APCI-MS/MS method was developed for the determination of ergosta-4,6,8(14),22-tetraen-3-one (ergone) in rat plasma. The plasma sample containing ergone and ergosterol (internal standard) were simply treated with acetone to precipitate and remove proteins and the isolated supernatants were directly injected into the HPLC–APCI-MS/MS system. Chromatographic separation was performed on a 1.8 μm Zorbax SB-C18 column (100 mm × 3.0 mm) with a 97:3 (v/v) mixed solution of methanol and 0.1% aqueous formic acid being used as mobile phase. Quantification was performed by multiple selected reactions monitoring (MRM) of the transitions with (m/z)+ 393–268 for ergone and (m/z)+ 379–69 for the IS. The method was validated in the concentration range of 5–1600 ng/mL for ergone. The precision of the assay (RSD%) was less than 10.5% at all concentrations levels within the tested range and adequate accuracy, and the limit of detection was 1.5 ng/mL. The absolute recoveries of both ergone and ergosterol from the plasma were more than 95%. The developed method has been successfully applied to the pharmacokinetic study of the drug in SD rats.  相似文献   

20.
Quantification of α- and γ-endorphins in rat brain using liquid chromatography-electrospray ionization-tandem mass spectrometry is described. [D-Ala2]-γ-endorphin is used as an internal standard. The precursor-to-product ion MRM transitions for α-endorphin, γ-endorphin, and [D-Ala2]-γ-endorphin were m/z 873.6 → 429.6; 929.6 → 542.3; 936.6 → 542.3, respectively. The method was validated in terms of linearity, specificity, sensitivity, recovery, precision, and accuracy. The assay was linear over a concentration range of 0.1-200 ng/mL with the limit-of-detection of 0.03 ng/mL and limit-of-quantification of 0.1 ng/mL. The endogenous concentrations of α- and γ-endorphins in rat brains were 13.8 ± 0.57 (mean ± SD; n = 5) and 2.5 ± 0.43 ng/g of wet tissue weight, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号