首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel, simple and fast reversed-phase HPLC/UV method was developed, optimized for various chromatographic conditions, and validated according to international guidelines for simultaneous determination of all-trans-retinol and α-tocopherol in human serum using retinyl acetate as internal standard in the concentration of 0.5 μg/ml. A liquid-phase extraction was applied to the 250 μl of serum with n-hexane–dichloromethane mixture (70:30, v/v), in two steps, using ethanol–methanol mixture (95:5, v/v) for protein precipitation and BHT (butylated hydroxy toluene) as stabilizer for sample preparation. Both analytes were analyzed on Kromasil 100 C18 column (150 mm × 4.6 mm, 5 μm), Brownlee analytical (Perkin Elmer) C18 column (150 mm × 4.6 mm, 5 μm), and Supelco (Supelcosil) LC-18 column (150 mm × 3 mm, 3 μm), protected by a Perkin Elmer C18 (30 mm × 4.6 mm, 10 μm; Norwalk, USA) pre-column guard cartridge, at 292 nm wavelength, using methanol–water (99:1, v/v), in isocratic mode as mobile phase applied at flow rate of 1.5 ml/min and 1 ml/min for both 5 μm and 3 μm columns, respectively. Complete separation of all the analytes was achieved in 3 and 6 min on 3 μm and 5 μm columns, respectively by injecting 20 μl of sample into the HPLC system by autosampler, keeping column oven temperature at 25 °C. Different particulate reversed-phase chromatographic columns were evaluated in order to select the best column in terms of sensitivity, selectivity, resolution and short run time of both the analytes and it was concluded that 3 μm columns are better to be used in clinical set up as well as in laboratories for the separation of these analytes in a shorter time as compared with 5 μm columns. The method was validated and applied for the analysis of all-trans-retinol and α-tocopherol in the serum of human volunteers.  相似文献   

2.
A sensitive and rapid HTLC–ESI-MS/MS method with an advanced online sample preparation was developed for determination of the γ-secretase inhibitor MK-0752 in human plasma using an internal standard. Plasma samples (100 μL) were diluted and injected directly onto an online extraction column (Cohesive Cyclone MAX 0.5 mm × 50 mm, >30 μm), the sample matrix was washed out with an aqueous solution, and retained analytes were eluted out and transferred directly to the analytical column (Phenomenex Gemini 3μ C18 110A, 50 mm × 2.0 mm at 50 °C) for separation using a gradient mobile phase. The eluted analytes were then detected on an API-3000 LC–MS/MS System with ESI and a negative multiple reaction monitoring mode. The monitored ion transitions were m/z 441 → 175 for MK-0752 and 496 → 175 for the internal standard. Online extraction recoveries were 81%. The method was validated and was linear in the range of 0.05–50 μg/mL. Within-day and between-day precisions were < 8.6%, and accuracies were 0.7 and 7.1%. This method was applied to the measurement of plasma MK-0752 levels in a Phase I study of pediatric patients with recurrent or refractory brain tumors.  相似文献   

3.
A rapid, inexpensive, sensitive and specific HPLC-ECD method for the determination of lipoic acid in human plasma was developed and validated over the linearity range of 0.001–10 μg/ml using naproxen sodium as an internal standard (IS). Extraction of lipoic acid and IS from plasma (250 μl) was carried out with a simple one step liquid–liquid extraction using dichloromethane. Similarly solid-phase extraction was carried out using dichloromethane as extraction solvent. The separated organic layer was dried under the stream of nitrogen at 40 °C and the residue was reconstituted with the mobile phase. Complete separation of both lipoic acid and IS at 30 °C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 6 min using 0.05 M phosphate buffer (pH 2.5 adjusted with phosphoric acid):acetonitrile (50:50, v/v) as a mobile phase pumped at the rate of 1.5 ml/min using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification of lipoic acid were 200 pg/ml and 1 ng/ml, respectively. While on column limit of detection and limit of quantification of lipoic acid were 10 and 50 pg/ml, respectively. The absolute recoveries of lipoic acid with liquid–liquid and solid-phase extraction were 98.43, 95.65, 101.45, and 97.36, 102.73, 100.17% at 0.5, 1 and 5 μg/ml levels, respectively. Coefficient of variations for both intra-day and inter-day were between 0.28 and 4.97%. The method is validated and will be quite suitable for the analysis of lipoic acid in the plasma of human volunteers as well as patients with diabetes and cardiovascular diseases.  相似文献   

4.
In the present study, a simple and sensitive high performance liquid chromatography with fluorescence detection (HPLC-FD) method was developed to determine TJ0711 hydrochloride, a novel α- and β-receptor blocker. TJ0711 hydrochloride and verapamil hydrochloride (the internal standard) were separated on Knauer Eurospher C18 (250 mm × 4.0 mm i.d., 5 μm) column at 50 °C. The mobile phase was methanol:perchloric acid (12 nM, aq) (56:44, v:v), with a flow rate of 1.0 mL/min. The wavelengths of FD were set at 246 nm for excitation and 300 nm for emission. For plasma samples of rats, the analytes were extracted with acetic ether from alkalinized plasma, and then back-extracted into 10 mM dilute sulfuric acid. The linearity was over a concentration range of 20–10,000 ng/mL. The intra- and inter-day precisions referred by relative standard deviation were less than 2.0% and 4.3%, respectively. The mean analytical recoveries of TJ0711 hydrochloride at different concentrations (50, 1000 and 8000 ng/mL) ranged from 88.3% to 92.9%. The lower limit of quantification (LLOQ) was 20 ng/mL. Finally, this method was successfully applied to the estimation of pharmacokinetic parameters of TJ0711 hydrochloride after intravenous doses of 4, 8 and 16 mg/kg in rats.  相似文献   

5.
This work has undertaken liquid chromatographic separation of nucleosides and deoxynucleosides. Two different columns with three mobile phases (A, deionized water; B, 50 mM phosphate buffer (pH 4.0); C, methanol) and slightly different gradient programs were used. The elution order was as follows: cytidine (C), 2′-deoxycytidine (dC), uridine (U), 5-methyl-2′-cytidine (5mC), 5-methyl-2′-deoxycytidine (5mdC), guanosine (G), deoxyguanosine (dG), 2′-deoxythymidine (dT), adenosine (A), and 2′-deoxyadenine (dA). Using a Luna C18 Phenomenex column (150 × 4.6 mm, 5 μm), the separation was performed at 40 °C with a total flow rate of 1 ml/min and a run time of 10 min. The second column was an Agilent C18 (50 × 3 mm, 1.8 μm), for which the run time was 4.5 min with a flow rate of 0.6 ml/min (25 °C). In application to the DNA digests from human THP-1 cells, the quantification of C, dC, U, 5mC, 5mdC, G, dG, and A was performed. The percentages of global methylation were evaluated based on the 5mdC and dC concentrations (c5mdC / [c5mdC + cdC], where c is concentration in μg/ml) and compared with those calculated from the respective peak areas (A5mdC / [A5mdC + AdC], where A is peak area at 254 nm). For peak area measurements, excellent agreement was obtained with the results reported previously in the same cell line. In the quantitative approach, the results of DNA methylation were higher but consistent with the previous data obtained using mass spectrometric detection. Comparing the analytical features of the two procedures, the use of a smaller column could be recommended because it provides efficient separation (capacity factors in the range of 1.29-10.66), a short run time, and feasibility of nucleoside and deoxynucleoside quantification in real-world samples and because it also minimizes the use of reagents.  相似文献   

6.
Gene silencing induced by short interfering RNA (siRNA) has proven to be useful in genomic research and has great potential for therapeutic applications; however, siRNAs are not readily bioavailable. Cationic liposomes offer effective protection of drug product from nucleases and enable distribution to desired target organs. The amount of siRNA in the formulation must be determined accurately. We have developed a stability-indicating, ion-pair, reversed-phase high-performance liquid chromatography method to separate and accurately quantitate two siRNA duplexes in a liposome without sample pretreatment. The gradient mobile phase system consisted of 385 mM hexafluoro-2-propanol, 14.5 mM triethylamine, and 5% methanol (mobile phase A) and 385 mM hexafluoro-2-propanol, 14.5 mM triethylamine, and 90% methanol (mobile phase B). The column used was an XBridge C18 column (50 × 2.1 mm i.d., 2.5 μm particle size), and separation was performed at 60 °C. Quantitation was achieved with ultraviolet (UV) detection at 260 nm. Linearity was established for the single strands of both siRNA duplexes for concentrations ranging from 10 to 110 μg/ml. Accuracy of the method was determined by replicate analysis (n = 5) at four concentrations (R> 0.996 and relative standard deviations [RSDs] of 1-4%). The use of an ion-pairing reagent that is compatible with mass spectrometry detection makes this method amenable to liquid chromatography-mass spectrometry (LC-MS) impurity profiling.  相似文献   

7.
Nicotine can be determined in pharmaceuticals and biological fluids by micellar liquid chromatography (MLC) using a C18 column, a mobile phase containing sodium dodecyl sulphate 0.15 M–6% (v/v) pentanol–NaH2PO4 0.01 M (pH 6)–KCl 0.001 M, with electrochemical detection at 0.8 V. In the optimization step, the influence of the modifiers propanol, butanol and pentanol, and the voltage has been studied. With the proposed method the analysis time is below than 8 min, linearity better than 0.999, limits of detection and quantification (ng/ml) was 4 and 12 respectively, repeatability and intermediate precision below 1.8%, and all these parameters are adequate for the quantification of nicotine in chewing gum, dermal patches, tobacco and serum samples either by a pharmacologist, pathologist or toxicologist.  相似文献   

8.
A simple, fast and validated method is reported for the simultaneous analysis, in human plasma, of several drugs usually combined in cardiovascular therapy (atenolol, bisoprolol, hydrochlorothiazide, chlorthalidone, salicylic acid, enalapril and its active metabolite enalaprilat, valsartan and fluvastatin) using high performance liquid chromatography–tandem mass spectrometry (LC–MS/MS) with electrospray ionization (ESI), working in multiple reaction monitoring mode (MRM). Separation of analytes and internal standard (pravastatin) was performed on a Luna C18(2) (150 mm × 4.6 mm, 3 μm) column using a gradient elution mode with a run time of 15 min. The mobile phase consisted of a mixture of acetonitrile and water containing 0.01% formic acid and 10 mM ammonium formate at pH 4.1. Sample treatment consisted of a simple protein precipitation with acetonitrile, enabling a fast analysis. The method showed good linearity, precision (RSD% values between 0.7% and 12.7%) and accuracy (relative error values between 0.9% and 14.0%). Recoveries were within 68–106% range and the ion-suppression was not higher than 22% for any analyte. The method was successfully applied to plasma samples obtained from patients under combined cardiovascular treatment.  相似文献   

9.
The capacity of hydrophobic octadecyl (C18) and SDR HyperD materials to remove the combination of 1% (v/v) solvent (tri-n-butyl phosphate, TnBP) with 1% (v/v) nonionic detergents (Triton X-100 and Triton X-45) used for viral inactivation of plasma-derived polyvalent intravenous immunoglobulin G (IVIG) preparation has been evaluated. Efficient removal of TnBP (<10 ppm in IVIG preparation) was found at ratios of 0.5 g of C18/7 ml of IVIG and 0.22 g of dry SDR HyperD/7 ml of IVIG. Binding capacities of TnBP were greater than 140 mg/g of C18 and greater than 318 mg/g of dry SDR HyperD. Complete removal of Triton X-45 (<2 ppm) was obtained at ratios of 1 g of C18/7 ml of IVIG and 0.44 g of dry SDR HyperD/7 ml of IVIG or above, corresponding to binding capacities in excess of 70 mg/g of C18 and in excess of 159 mg/g of dry SDR HyperD. Residual Triton X-100 was less than 30 ppm at a ratio of 4 g/14 ml of immunoglobulin G (IgG) for the C18 sorbent. Triton X-100 was less than 10 ppm when using SDR HyperD at a ratio of 0.66 g/7 ml of IgG, corresponding to a binding capacity of approximately 106 mg of Triton X-100/g of dry SDR HyperD. Good recoveries of IVIG were achieved in the effluent from both sorbents.  相似文献   

10.
A simple and sensitive HPLC method was established and validated for the determination of docetaxel (DTX) in rabbit plasma. Biosamples were spiked with paclitaxel (PCX) as an internal standard (I.S.) and pre-treated by solid-phase extraction (SPE). The SPE procedure followed a simple protein digestion was based on nylon6 electrospun nanofibers mats as sorbents. Under optimized conditions, target analytes in 500 μL of plasma sample can be completely extracted by only 2.5 mg nylon6 nanofibers mat and eluted by 100 μL solvent. The HPLC separation was obtained on C18 column and UV detector was used to quantify the target analytes. The extraction recovery was more than 85%; the standard curve was linear over the validated concentrations range of 10–5000 ng/mL and the limit of detection was 2 ng/mL. The inter-day coefficient of variation (CV%) of the calibration standards was below 5.0% and the mean accuracy was in the range of 92.8–113.4%. Moreover, analysing quality control plasma samples in 3 days, the results showed that the method was precise and accurate, for the intra- and inter-day CV% within 10% and the accuracy from 96.0% to 114.0%. The developed and validated method was successfully applied to relative bioavailability study for the preclinical evaluation of a new injectable DTX–sulfobutyl ether beta-cyclodextrin (DTX–SBE-β-CD) inclusion complex freeze-dried powder (test preparation), compared with the reference preparation (DTX injection, Taxotere®) in healthy rabbits. On the basis of the mean AUC(0–t) and AUC(0–infinity), the relative bioavailability of the test preparation was found to be 113.1%.  相似文献   

11.
We report a rapid and simple HPLC method with fluorescence detection for the quantification of the major flaxseed lignan, secoisolarisiresinol diglucoside (SDG) and its major metabolites. The method is specific for SDG, secoisolarisiresinol (SECO), enterodiol (ED) and entrolactone (EL) in rat serum. The assay procedure involves chromatographic separation using a Waters Symmetry C18 reversed-phase column (4.6 mm × 150 mm, 5 μm) and mobile phase gradient conditions consisting of acetonitrile (0.1% formic acid) and water (0.1% formic acid). SDG extraction from serum requires the use of Centrifuge filters while SECO, ED and EL are extracted with diethyl ether. The organic layer is evaporated and reconstituted in 100 μL of mobile phase and 50 μL of reconstituted sample or filtrate is injected onto the column. Total run time is 25 min. Calibration curves are linear (r2 ≥ 0.997) from 0.05 to 10 μg/mL for SDG and EL and 0.01–10 μg/mL for SECO and ED. Precision and accuracy are within USFDA specified limits. The stability of all lignans is established in auto-injector, bench-top, freeze–thaw and long-term stability at −80 °C for 30 days. The method's reasonable sensitivity and reliance on more widely available HPLC technology should allow for its straightforward application to pharmacokinetic evaluations of lignans in animal model systems such as the rat.  相似文献   

12.
Fentanyl and its major metabolite norfentanyl often occur in low doses in biological samples. Therefore, a highly sensitive liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed and fully validated. Sample preparation was performed on a mixed-mode cation exchange solid phase extraction (SPE) cartridge with an additional alkaline wash step to decrease matrix effects and thus increase sensitivity. Ionization of fentanyl and norfentanyl with electrospray ionization (ESI) was more efficient than atmospheric pressure chemical ionization (APCI). The use of a mobile phase of high pH resulted in higher ESI signals than the conventional low pH mobile phases. In the final method, gradient elution with 10 mM ammonium bicarbonate (pH 9) and methanol was performed. A comparison of columns with different internal diameter and/or smaller particles showed optimal resolution and sensitivity when an Acquity C18 column (1.7 μm, 2.1 mm × 50 mm) was used. Deuterium labeled internal standards were used, but with careful evaluation of their stability since loss of deuteriums was seen. With limits of detection of 0.25 pg/ml for fentanyl and 2.5 pg/ml for norfentanyl in urine and 5 pg/ml for fentanyl and norfentanyl in whole blood the presented method is highly appropriate for the analysis of fentanyl and norfentanyl in forensic urine and blood samples.  相似文献   

13.
A sensitive, simple and rapid ultra fast liquid chromatography (UFLC)–ESI-MS/MS method was developed for the determination of 2-hydroxyflutamide in human plasma using tegafur as the internal standard. The plasma sample was pretreated with methanol for protein precipitation and the analytes were separated on an Ultimate C18 column (5 μm, 2.1 mm × 50 mm, MD, USA) with the mobile phase consisted of acetonitrile and water (2:1, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer under a negative multiple reaction-monitoring mode (MRM). The mass transition ion-pair was followed as m/z 290.90–204.8 for 2-hydroxyflutamide and 198.9–128.8 for tegafur. Linear calibration curves were obtained in the concentration range of 1.742–1452 ng/ml with a lower limit of quantification of 1.742 ng/ml. The intra- and inter-batch precision values were less than 8.1% and 5.6%, respectively. The established method was successfully applied to a bioequivalence study of two flutamide preparations (250 mg) in 20 healthy male volunteers.  相似文献   

14.
A sensitive, selective and high throughput liquid chromatography tandem mass spectrometry (LC–ESI-MS/MS) method has been developed for the determination of teriflunomide, an active metabolite of leflunomide in human plasma. Plasma samples were prepared by liquid–liquid extraction of teriflunomide and valsartan as internal standard (IS) in ethyl acetate from 200 μL human plasma. The chromatographic separation was achieved on an Inertsil ODS-3 C18 (50 mm × 4.6 mm, 3 μm) analytical column using isocratic mobile phase, consisting of 20 mM ammonium acetate–methanol (25:75, v/v), at a flow-rate of 0.8 mL/min. The precursor → product ion transition for teriflunomide (m/z 269.0 → 82.0) and IS (m/z 434.1 → 350.3) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and negative ion mode. The method was validated over a wide dynamic concentration range of 10.1–4001 ng/mL. Matrix effect was assessed by post-column infusion experiment and the mean process efficiency were 91.7% and 88.2% for teriflunomide and IS respectively. The method was rugged and rapid with a total run time of 2.0 min and is applied to a bioequivalence study of 20 mg leflunomide (test and reference) tablet formulation in 12 healthy Indian male subjects under fasting condition.  相似文献   

15.
A novel, sensitive and reliable liquid chromatography–tandem mass spectrometric (LC–MS/MS) method was developed and validated for the determination of belinostat (PXD101) in human plasma. Oxamflatin was used as the internal standard. Liquid–liquid extraction of the plasma sample was performed using tert-butyl methyl ether as the organic solvent. Chromatographic separation was achieved on a BDS Hypersil C18 column (2.1 mm × 100 mm, 5 μm) using gradient elution mode using 0.05% formic acid in water and 0.05% formic acid in acetonitrile as solvents A and B, respectively, 60/40. The run time was 6 min. The mass spectrometer was operated under a positive electrospray ionization condition and a multiple reaction monitoring mode. An excellent linear calibration was achieved in the range of 0.5–1000 ng/mL. An average recovery of belinostat for four quality controls was 72.6% and the recovery of the internal standard at 1000 ng/mL was 67.8%. The intra-day and inter-day precisions for belinostat were ≤8.0 and ≤10.3%, respectively, and their accuracy ranged from 100.2 to 106.7%. No significant matrix effect was identified. In analysis of patient samples, belinostat glucuronide was identified and baseline separated from belinostat. This well-validated assay has been applied for quantification of belinostat in plasma samples within 24 h after the start of infusion for Asian hepatocellular carcinoma patients in a dose escalation study.  相似文献   

16.
Flavanoid kaempferol is mainly present as glucuronides and sulfates in rat plasma, and small amounts of the intact aglycone are also detected. In the this study, a rapid, specific and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry method (HPLC–MS/MS) was developed and validated for determination of kaempferol and its major metabolite glucuronidated kaempferol in rat plasma. A liquid–liquid extraction with acetic ether was involved for the extraction of kaempferol and internal standard. Analytes were separated on a C18 column (150 mm × 2.1 mm, 4.5 μm, Waters Corp.) with isocratic elution at a flow-rate of 0.3 ml min−1. The mobile phase was consisted of 0.5% formic acid and acetonitrile (50:50, v/v). The Quattro Premier HPLC–MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. The method was validated according to the FDA guidelines for validation of bioanalytical method. The validated method was successfully applied to the study of the pharmacokinetics in rats after oral administration of kaempferol with different doses.  相似文献   

17.
A rapid, simple and sensitive HPLC–ESI–MS/MS method was developed for the simultaneous determination of capsaicin and dihydrocapsaicin in rat plasma. Plasma samples containing capsaicin, dihydrocapsaicin and phenacetin (internal standard) were prepared based on a simple protein precipitation by the addition of two volumes of acetonitrile. The analytes and internal standard were separated on a Zorbax SB-C18 column (3.5 μm, 2.1 mm × 100 mm) with mobile phase of acetonitrile/water (55:45, v/v) containing 0.1% formic acid (v/v) at a flow rate of 0.2 mL/min with an operating temperature of 25 °C. Quantification was performed on a triple quadrupole mass spectrometer equipped with electrospray ionization (ESI) source by selected reaction monitoring (SRM) of the transitions at m/z 306–137 for capsaicin, m/z 308–137 for dihydrocapsaicin and m/z 180–110 for the IS. Linear detection responses were obtained for capsaicin and dihydrocapsaicin ranging from 1 to 500 ng/mL and the lower limits of quantitation (LLOQs) for the two compounds were 1 ng/mL. The intra- and inter-day precisions (R.S.D.%) were within 9.79% for the two analytes, while the deviations of assay accuracies were within ±10.63%. The average recoveries of the analytes were greater than 89.88%. The analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic studies of capsaicin and dihydrocapsaicin in rats after subcutaneous administration of capsaicin (natural, containing 65% capsaicin and 35% dihydrocapsaicin).  相似文献   

18.
A new simple, sensitive and precise liquid chromatography-tandem mass spectrometry method has been developed and validated for the determination of valacyclovir-HCl and acyclovir in tsetse flies (Glossina pallipides). Tsetse flies were extracted by ultrasonication with acidified methanol/acetonitrile, centrifuged and cleaned up by solid phase dispersion using MgSO4 and MSPD C18 material. Samples were analysed using a Waters Alliance 2695 series HPLC with a C18 Gemini analytical column (150 mm × 4.6 mm × 5 μm) and a guard cartridge column connected to a Waters Quattro-Micro triple-quadrupole mass spectrometer. The isocratic mobile phase consisted of methanol:acetonitrile:water (60:30:10, v/v/v) plus formic acid (0.1%) at a flow rate of 0.25 ml/min. The precursor > product ion transition for valacyclovir (m/z 325.1 > 152) and acyclovir (m/z 226.1 > 151.9) were monitored in positive electrospray multiple reaction monitoring mode. The method was validated at fortification levels of 0.5, 1 and 2 μg/g. The range of calibration for both drugs was 0.45-4.5 μg/g. The overall accuracy of the method was 92% for valacyclovir and 95% for acyclovir with corresponding within-laboratory reproducibilities of 4.4 and 3.4%, respectively. Mean recoveries were above 80% for both drugs and repeatability ranged from 0.7 to 6.1%. For both drugs the limits of detection and quantification were 0.0625 and 0.2 μg/g, respectively. The method was applied in experiments on the mass rearing of tsetse flies for sterile insect technique (SIT) applications, in which the flies were fed with blood meals containing acyclovir or valcyclovir-HCl prior to analysis to assess effects on Glossina pallidipes Salivary Gland Hypertrophy syndrome.  相似文献   

19.
We investigated whether diapause pupae of Byasa alcinous exhibit pupal color diphenism (or polyphenism) similar to the diapause pupal color polyphenism shown by Papilio xuthus. All diapause pupae of B. alcinous observed in the field during winter showed pupal coloration of a dark-brown type. When larvae were reared and allowed to reach pupation under short-day conditions at 18 °C under a 60 ± 5% relative humidity, diapause pupae exhibited pupal color types of brown (33%), light-brown (25%), yellowish-brown (21%), diapause light-yellow (14%) and diapause yellow (7%). When mature larvae reared at 18 °C were transferred and allowed to reach pupation at 10 °C and 25 °C under a 60 ± 5% relative humidity after a gut purge, the developmental ratio of brown and light-brown, yellowish-brown, and diapause light-yellow and diapause yellow types was 91.2, 8.8 and 0.0% at 10 °C, and 12.2, 48.8 and 39.0% at 25 °C, respectively. On the other hand, when mature larvae reared at 18 °C were transferred and allowed to reach pupation at 10 °C, 18 °C and 25 °C under an over 90% relative humidity after a gut purge, the developmental ratio of brown and light-brown, yellowish-brown, and diapause light-yellow and diapause yellow types was 79.8, 16.9 and 3.3% at 10 °C, 14.5, 26.9 and 58.6% at 18 °C, and 8.3, 21.2 and 70.5% at 25 °C, respectively. These results indicate that diapause pupae of brown types are induced by lower temperature and humidity conditions, whereas yellow types are induced by higher temperature and humidity conditions. The findings of this study show that diapause pupae of B. alcinous exhibit pupal color diphenism comprising brown and diapause yellow types, and suggest that temperature and humidity experienced after a gut purge are the main factors that affect the diapause pupal coloration of B. alcinous as environmental cues.  相似文献   

20.
A highly sensitive HPLC method with automated column switching was developed for the simultaneous determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in plasma samples from man, Cynomolgus monkey, rabbit, rat and mouse. Plasma (0.4 ml) was deproteinated by adding ethanol (1.5 ml) containing the internal standard acitretin. After centrifugation, 1.4 ml of the supernatant were directly injected onto the precolumn packed with LiChrospher 100 RP-18 (5 μm). 1.25% ammonium acetate and acetic acid-ethanol (8:2, v/v) was used as mobile phase during injection and 1% ammonium acetate and 2% acetic acid-ethanol (102:4, v/v) was added, on-line, to decrease the elution strength of the injection solution. After backflush purging of the precolumn, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm. Two coupled Superspher 100 RP-18 endcapped columns (both 250×4 mm) were used for the separation, together with a mobile phase consisting of acetonitrile-water-10% ammonium acetate-acetic acid: (A) 600:300:60:10 (v/v/v/v), (B) 950:20:5:20 (v/v/v/v), and (C) 990:5:0:5 (v/v/v/v). The method was linear in the range 0.3–100 ng/ml, at least, with a quantification limit of 0.3 ng/ml. The mean recoveries from human plasma were 93.2%–94.4% and the mean inter-assay precision was 2.8%–3.2% (range 0.3–100 ng/ml). Similar results were obtained for animal plasma. The analytes were found to be stable in the plasma of all investigated species stored at −20°C for 4.3 months and at −80°C for 9 months, at least. At this temperature, human plasma samples were even stable for 2 years. The method was successfully applied to more than 6000 human and 1000 animal plasma samples from clinical and toxicokinetic studies. Endogenous levels determined in control patients and pregnant women were similar to published data from volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号