首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Pulsatile flow in a model of a right coronary artery (RCA) was previously modeled as a single-phase fluid and as a two-phase fluid using experimental rheological data for blood as a function of hematocrit and shear rate. Here we present a multiphase kinetic theory model which has been shown to compute correctly the viscosity of red blood cells (RBCs) and their migration away from vessel walls: the Fahraeus–Lindqvist effect. The computed RBC viscosity decreases with shear rate and vessel size, consistent with measurements. The pulsatile computations were performed using a typical cardiac waveform until a limit cycle was well established. The RBC volume fractions, shear stresses, shear stress gradients, granular temperatures, viscosities, and phase velocities varied with time and position during each cardiac cycle. Steady-state computations were also performed and were found to compare well with time-averaged transient results. The wall shear stress and wall shear stress gradients (both spatial and temporal) were found to be highest on the inside area of maximum curvature. Potential atherosclerosis sites are identified using these computational results.  相似文献   

2.
Velocity and pressure fields, streamlines and wall shear stress distributions were numerically obtained for two-dimensional, steady and pulsatile flow in a carotid artery segment. Distinct regions of reverse flow near the bifurcation and wavy flow patterns in the branching channels were observed during portions of the pulse. These phenomena disappear at the end of the systolic phase of the cardiac cycle. A previously validated plaque formation model predicts that plaque sites and the local extent of atherosclerotic lesions are similar for those present on human angiograms.  相似文献   

3.
Pulsatile flow in a constricted channel.   总被引:1,自引:0,他引:1  
A nonuniform channel is used as a simple model of a constricted arterial vessel. Flow patterns have been calculated for pulsatile flow with both sinusoidal and nonsinusoidal flow rates for a range of Reynolds number, Re, and Strouhal number, St. The results show that even for relatively low frequency flows a strong vortex wave will be generated with a complex wall shear stress distribution and peak values much greater than those found in steady or unsteady parallel flow. The vortex wave increases in strength with increasing Re and St, with its total length and wavelength independent of Re but inversely proportional to St. The form of the imposed flow rate is found to have an important effect on the flow and the shear stress distribution.  相似文献   

4.
5.
6.
7.
Pulsatile flow past aortic valve bioprostheses in a model human aorta   总被引:1,自引:0,他引:1  
Pulsatile flow development past tissue valve prostheses in a model human aorta has been studied using qualitative flow visualization and quantitative laser-Doppler techniques. Experiments were conducted both in steady and physiological pulsatile flow situations and the measurements included the pressure drop across the valve, the instantaneous flow rate as well as the velocity profiles and turbulent stresses downstream to the valves. Our study shows that the velocity profiles with pericardial valves are closer to those measured past natural aortic valves. The porcine valves with a smaller valve opening area produce a narrower and stronger jet downstream from the valve with relatively larger turbulent axial stresses in the boundary of the jet. Our study suggests that the pericardial valves with turbulent stresses comparable to those of caged ball and tilting disc valves are preferable from a hemodynamic point of view.  相似文献   

8.
The fundamental study of blood flow past a circular cylinder filled with an oxygen source is investigated as a building block for an artificial lung. The Casson constitutive equation is used to describe the shear-thinning and yield stress properties of blood. The presence of hemoglobin is also considered. Far from the cylinder, a pulsatile blood flow in the x direction is prescribed, represented by a time periodic (sinusoidal) component superimposed on a steady velocity. The dimensionless parameters of interest for the characterization of the flow and transport are the steady Reynolds number (Re), Womersley parameter (alpha), pulsation amplitude (A), and the Schmidt number (Sc). The Hill equation is used to describe the saturation curve of hemoglobin with oxygen. Two different feed-gas mixtures were considered: pure O(2) and air. The flow and concentration fields were computed for Re=5, 10, and 40, 0< or =A< or =0.75, alpha=0.25, 0.4, and Schmidt number, Sc=1000. The Casson fluid properties result in reduced recirculations (when present) downstream of the cylinder as compared to a Newtonian fluid. These vortices oscillate in size and strength as A and alpha are varied. Hemoglobin enhances mass transport and is especially important for an air feed which is dominated by oxyhemoglobin dispersion near the cylinder. For a pure O(2) feed, oxygen transport in the plasma dominates near the cylinder. Maximum oxygen transport is achieved by operating near steady flow (small A) for both feed-gas mixtures. The time averaged Sherwood number, Sh, is found to be largely influenced by the steady Reynolds number, increasing as Re increases and decreasing with A. Little change is observed with varying alpha for the ranges investigated. The effect of pulsatility on Sh is greater at larger Re. Increasing Re aids transport, but yields a higher cylinder drag force and shear stresses on the cylinder surface which are potentially undesirable.  相似文献   

9.
This paper presents the detailed pulsatile pressure and flow velocity patterns inside an axis symmetric stenosis model with 75% constriction. The pressure and velocities have been calculated by solving the Navier-Stokes equations by the finite element method, the velocity profile in a straight tube caused by a pulsating driving pressure has been calculated first and then used as a boundary condition for the stenosis calculations. The results of the mathematical simulations of the stenosis model have been obtained in terms of velocity vectors, streamlines and isobars at 16 different instances in time, each 15 degrees apart during a cardiac cycle. The calculated velocity field shows that a vortex is developed at the wall distal to the stenosis as the velocity decreases from the peak systolic value. At the site of the vortex, a local pressure minimum is found due to the conversion of pressure to kinetic energy. When the flow is reversed, the reversal occurs first along the wall, thus forcing the vortex toward the the centre of the tube. As the reverse flow velocity increases, a vortex is also developed at the proximal site of the stenosis.  相似文献   

10.
11.
Numerical analysis of flow phenomena and wall shear stresses in the human carotid artery bifurcation has been carried out using a three-dimensional geometrical model. The primary aim of this study is the detailed discussion of non-Newtonian flow velocity and wall shear stress during the pulse cycle. A comparison of non-Newtonian and Newtonian results is also presented. The applied non-Newtonian behavior of blood is based on measured dynamic viscosity. In the foreground of discussion are the flow characteristics in the carotid sinus. The investigation shows complex flow patterns especially in the carotid sinus where flow separation occurs at the outer wall throughout the systolic deceleration phase. The changing sign of the velocity near the outer sinus wall results in oscillating shear stress during the pulse cycle. At the outer wall of the sinus at maximum diameter level the shear stress ranges from -1.92 N/m2 to 1.22 N/m2 with a time-averaged value of 0.04 N/m2. At the inner wall of the sinus at maximum diameter level the shear stress range is from 1.16 N/m2 to 4.18 N/m2 with a mean of 1.97 N/m2. The comparison of non-Newtonian and Newtonian results indicates unchanged flow phenomena and rather minor differences in the basic flow characteristics.  相似文献   

12.
This paper deals with the pulsatile blood flow in the lung alveolar sheets by idealizing each of them as a channel covered by porous media. As the blood flow in the lung is of low Reynolds number, a creeping flow is assumed in the channel. The analytical and numerical results for the velocity and pressure distribution in the porous medium are presented. The effect of an imposed slip condition is also studied. Comparisons with the corresponding results for the steady-state case are made at the end.  相似文献   

13.
The pressure and flow patterns within arterial aneurysms are little known. In the present work the equations describing pulsatile flow, the Navier-Stokes equations, are solved numerically using the finite element method with a computer. The solutions of the Navier-Stokes equations are obtained at 24 points in time during the cardiac cycle. At selected instants in time, the solutions are presented as velocity vectors, streamlines and isobars. The results demonstrate a vortex formation during most of the cycle. The pressure within the aneurysm is nearly constant. At the downstream end of the expansion,high pressure gradients are found.  相似文献   

14.
Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.  相似文献   

15.
The pulsatile blood flow and gas transport of oxygen and carbon dioxide through a cylindrical array of microfibers are numerically simulated. Blood is modeled as a homogeneous Casson fluid, and hemoglobin molecules in blood are assumed to be in local equilibrium with oxygen and carbon dioxide. It is shown that flow pulsatility enhances gas transport and the amount of gas exchange is sensitive to the blood flow field across the fibers. The steady Sherwood number dependence on Reynolds number was shown to have a linear relation consistent with experimental findings. For most cases, an enhancement in gas transport is accompanied with an increase in flow resistance. Maximum local shear stress is provided as a possible indicator of thrombosis, and the computed shear stress is shown to be below the threshold value for thrombosis formation for all cases evaluated.  相似文献   

16.
K Perktold  R Peter  M Resch 《Biorheology》1989,26(6):1011-1030
Blood flow is analysed by means of computer simulation in an idealized arterial bifurcation model which is pathologically altered by a saccular aneurysm. The theoretical study of the flow pattern and the paths of fluid particles is carried out under pulsatile Newtonian and non-Newtonian flow conditions. The governing equations are solved numerically with the use of the finite element method. The results show the disturbed blood flow in the bifurcation and the relatively low intra-aneurysmal flow circulation. In addition to the study of basic flow patterns in the segment, a comparison of non-Newtonian and Newtonian results is carried out. This comparison proves that for the considered large artery model under physiological flow conditions where the yield number is relatively low there is no essential difference in the results.  相似文献   

17.
Pulsatile pressure and flow in the skeletal muscle microcirculation   总被引:2,自引:0,他引:2  
Although blood flow in the microcirculation of the rat skeletal muscle has negligible inertia forces with very low Reynolds number and Womersley parameter, time-dependent pressure and flow variations can be observed. Such phenomena include, for example, arterial flow overshoot following a step arterial pressure, a gradual arterial pressure reduction for a step flow, or hysteresis between pressure and flow when a pulsatile pressure is applied. Arterial and venous flows do not follow the same time course during such transients. A theoretical analysis is presented for these phenomena using a microvessel with distensible viscoelastic walls and purely viscous flow subject to time variant arterial pressures. The results indicate that the vessel distensibility plays an important role in such time-dependent microvascular flow and the effects are of central physiological importance during normal muscle perfusion. In-vivo whole organ pressure-flow data in the dilated rat gracilis muscle agree in the time course with the theoretical predictions. Hemodynamic impedances of the skeletal muscle microcirculation are investigated for small arterial and venous pressure amplitudes superimposed on an initial steady flow and pressure drop along the vessel.  相似文献   

18.
Pulsatile poststenotic flow studies with laser Doppler anemometry   总被引:2,自引:1,他引:1  
The pulsatile flow field distal to axisymmetric constrictions in a straight tube was studied using laser Doppler anemometry. The upstream centerline velocity waveform was sinusoidal at a frequency parameter of 7.5 and mean Reynolds number of 600. Stenosis models of 25, 50 and 75% area reduction were employed and velocity data were derived by ensemble averaging methods. Extensive measurements of the pulsatile velocity profiles are reported, and wall shear rates were computed from the near wall velocity profile gradients. The experiments indicate that a permanent region of poststenotic flow separation does not exist even for the severest constriction, in contrast to results for steady flow. Values of wall shear stress were greatest near the throat of the constriction and were relatively low in the poststenotic region, including the region of most intense flow disturbance. Turbulence was found only for the 75% stenosis model and was created only during a segment of the cycle. Although much emphasis has been placed upon turbulence in the detection of arterial stenoses, particularly as identified by Doppler ultrasound spectral broadening, the present study implies that identification of flow disturbances of an organized nature may be more fundamental in recognizing mild to moderate disease. Additionally, the relationship of these flow field results to the animal aortic coarctation model often employed in atherogenesis studies is discussed.  相似文献   

19.
The noninvasive quantification of mitral regurgitation remains an important clinical goal. Recently, the flow convergence method was developed to estimate the regurgitant flow rate. This study used three-dimensional pulsatile flow computational simulations to evaluate the accuracy of the flow convergence method in the presence of complicating factors such as ventricular confinement, noncircular orifice shape, and the presence of aortic outflow. Results showed that in the absence of aortic outflow and ventricular confinement, there was a plateau zone where the calculated flow rate by the hemispheric formula approximated the true flow rate, independent of the orifice shape. In the presence of aortic outflow and in chambers of physiologic dimensions, there was no longer a clear zone where the hemispheric formula was valid. The hemi-elliptic modification of the flow convergence method worked in all cases, independent of the degree of ventricular confinement or the presence of aortic outflow. Therefore, application of the hemi-elliptic formula should be considered in future clinical studies.  相似文献   