首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ehlers-Danlos syndrome is an inherited collagen disorder characterized by skin hyperextensibility, joint laxity, and tissue friability. In this study, it was hypothesized that Ehlers-Danlos syndrome is frequently undiagnosed in patients who present for repair of ventral abdominal wall hernias. A retrospective chart review was conducted, and patients who had presented for elective repair of recurrent abdominal wall herniation were identified. In all patients, one or more prior attempts at repair with either mesh or autologous tissues had failed. Patients in whom abdominal wall components were lost secondary to extirpation or trauma, patients who had required acute closure, and patients with less than 2 months of follow-up were excluded. Twenty patients met these criteria. Twenty cases of recurrent ventral hernia repairs were reviewed, with special attention to identification of the preoperative diagnosis of Ehlers-Danlos syndrome. Patients ranged in age from 29 to 75 years, with a mean age of 54 years. Five patients were male (25 percent), and 15 were female (75 percent). The majority (95 percent) were Caucasian. The most common initial procedures were gynecologic in origin (35 percent). A precise closure technique that minimizes recurrence after ventral hernia repairs was used. With use of this technique, there was only one recurrence over a follow-up period that ranged from 2 to 60 months (mean follow-up duration, 25.7 months). Two patients with Ehlers-Danlos syndrome were identified, and their cases are presented in this article. The "components separation" technique with primary component approximation and mesh overlay was used for defect closure in the two cases presented. The identification of these two patients suggests the possibility of underdiagnosis of Ehlers-Danlos syndrome among patients who undergo repeated ventral hernia repair and who have had previous adverse postoperative outcomes. There are no previous reports in the literature that address recurrent ventral abdominal herniation in patients with Ehlers-Danlos syndrome.  相似文献   

2.
The repair of ventral hernia defects of the abdominal wall challenges both general and plastic surgeons. Ventral herniation is a postoperative complication in 10 percent of abdominal surgeries; the repair of such defects has a recurrence rate as high as 50 percent. The "components separation" technique has successfully decreased the recurrence rates of ventral abdominal hernias. However, this technique has been associated with midline dehiscence and a prolonged postoperative stay at the authors' institutions. The purpose of this study was to determine whether endoscopically assisted components separation could minimize operative damage to the vasculature of the abdominal wall and decrease postoperative wound dehiscence. The study group consisted of seven patients who underwent endoscopically assisted components separation; the control group consisted of 30 patients who underwent open components separation. The two groups were similar regarding demographic data and defect size. The endoscopic group had a higher initial success rate than the open group (100 versus 77 percent). Recurrence rates were not significantly different between the two groups. However, the endoscopically assisted components separation patients had fewer postoperative and long-term complications. In the authors' experience, endoscopically assisted components separation has proved to be a safe and effective method for the repair of complicated and recurrent midline ventral hernias.  相似文献   

3.
Large abdominal wall defects (ventral hernias) can be difficult to repair. Some defects are not amenable to primary repair or the use of synthetic mesh because of repeated recurrence or wound infection. In complicated situations such as that mentioned above, the extended latissimus dorsi muscle flap has been used to repair upper and middle abdominal wall defects. This method has been utilized in six patients, and there has been no recurrence of the defect or evidence of a lumbar hernia. The follow-up has been from 7 to 66 months. The extended latissimus dorsi muscle flap has proven to be an excellent alternative in the repair of complicated abdominal wall defects.  相似文献   

4.
Sublay prosthetic herniorrhaphy has become a widely accepted procedure for incisional hernias. To evaluate the effect of fascia closure on top of mesh repair on infection, and the recurrence rate, the authors reviewed their data regarding herniorrhaphy in the sublay technique. This study was a retrospective analysis of 175 consecutive patients who underwent hernia repair by implantation of prostheses by means of the Stoppa-Rives technique from December of 1994 to December of 2001. All 175 patients had the mesh implanted in the subfascial plane, 130 received a light-weight or heavy-weight polypropylene mesh (Vypro or Prolene) (74 percent), eight had a polyester mesh (Mersilene) (5 percent), and 37 had an expanded polytetrafluoroethylene patch (Gore-Tex) (21 percent). After sublay mesh positioning, the mesh could not be covered by the fascia in 50 cases; in 31 of these cases, a second mesh was placed into the fascial defect. To evaluate the influence of the fascia closing procedure on top of the sublay mesh, three groups were differentiated: initial fascia closure (n = 125), no fascia closure and concomitant mesh interposition (n = 31), and no fascia closure without mesh interposition (n = 19). After a mean follow-up of 20 months, 11 deep prosthetic infections (8 percent) and 15 hernia recurrences (9 percent) were observed. There was an increased risk of mesh infection when the fascia could not be closed, but there was no influence of fascia closure on hernia recurrence. When the fascia was left open, the placement of a second mesh inlay technique reduced mesh infection. The authors' data give evidence that closing the ventral fascia after mesh repair in the sublay position is beneficial. When the edges of the hernia defect could not be approximated, the suturing of a second mesh into the fascia defect was a useful tool for reducing the prosthetic infection rate; however, no significant influence on hernia recurrence was observed.  相似文献   

5.
The authors report the successful repair of large lower abdominal hernia defects after transverse rectus abdominis muscle (TRAM) flap breast reconstruction in 11 patients using a technique of intraperitoneal application of synthetic polypropylene (Prolene) mesh anchored to the peritoneal surface of the abdominal wall tissues. Five of these patients had previously failed hernia repairs after a unipedicle TRAM flap breast reconstruction employing the onlay mesh technique, with two of the patients having undergone three previous hernia repairs. The other six patients had developed large hernias after bipedicle TRAM flap reconstruction without previous mesh supplementation of the abdominal wall repair. After their successful hernia repairs, all of the patients healed without difficulty and demonstrated no sign of recurrence in an 8 to 36-month follow-up. Each patient returned to her activity level before breast reconstruction.  相似文献   

6.
Secondary repair of recurrent ventral hernia is difficult, and success depends on re-establishing the functional integrity of the abdominal wall. Current techniques used for closure of these defects have documented recurrence rates as high as 54 percent. The authors' 8-year experience utilizing variations of the components separation technique for autologous tissue repair of recalcitrant hernias emphasizes that recurrent or recalcitrant hernias benefit from the creation of a dynamic abdominal wall. A total of 389 patients were retrospectively identified as having abdominal wall defects, and 284 of these patients met the selection criteria. Study patients were grouped according to the type of surgical repair used. The recurrence rate was 20.7 percent over all study groups and was directly related to the extent of repair required. Group 1 patients (wide tissue undermining) had a recurrence rate of only 15 percent, while in group 2 (complete components separation), the recurrence rate was 22 percent. Group 3 patients (interpositional fascia lata graft) had a 29 percent recurrence rate. Time to recurrence was also significantly different across treatment groups, with study group 3 experiencing earlier hernia recurrence. The most frequent postoperative complication was wound infection, which was directly related to the repair performed. The relative odds of recurrence versus the risk factors of age, sex, perioperative steroid use, wound infection, defect size, and the presence of enterocutaneous fistula were studied with a logistic regression analysis. These factors did not possess statistical significance for predicting hernia recurrence. The preoperative presence of mesh was independently significant for hernia recurrence, increasing the relative odds 2.2 times (p = 0.01). Similarly, when other risk factors were controlled for, increasing the complexity of the treatment group, from study group 1 (wide tissue undermining) to study group 3 (interpositional fascia lata graft), also increased the odds of hernia recurrence 1.5-fold per group (p = 0.04). Average inpatient cost was $24,488. The length of inpatient stay ranged from 2 to 172 days (average, 12.8 days). The length of inpatient stay and costs were directly related to the extent of repair required. Using the analysis of variance test for multiple factors, the presence of an enterocutaneous fistula (p = 0.0014) or a postoperative wound infection (p = 0.008) independently increased the length of inpatient stay and hospital costs. A total of 108 successfully repaired patients were contacted by telephone and agreed to participate in a self-reported satisfaction survey. The patients noticed improvements in the appearance of their abdomen, in their postoperative emotional state, and in their ability to lift objects, arise from a chair or a bed, and exercise. These results suggest that recalcitrant hernia defects should be solved, when possible, by reconstructing a dynamic abdominal wall.  相似文献   

7.
Lowe JB  Lowe JB  Baty JD  Garza JR 《Plastic and reconstructive surgery》2003,111(3):1276-83; quiz 1284-5; discussion 1286-8
The reconstruction of complex abdominal wall defects can often pose a significant challenge to surgeons and their patients. Complex ventral hernias may result from large tumor resections, trauma from gunshot wounds, or infections following routine abdominal surgery. "Components separation" of the abdominal musculature uses advancement of local autologous tissue, when available, to close large ventral wall defects. The authors report on a retrospective chart review of 30 patients who underwent components separation for the closure of complex abdominal defects. The study group was 50 percent female, with a mean age of 45 years, body mass index of 33.2 kg/m2, and abdominal defect size of 240 cm2. On average, 20 percent of patients had preoperative wound infections, 30 percent had intraoperative bowel enterotomies, and 33 percent required prosthetic mesh for closure. Total surgery time averaged 4.8 hours, with a mean postoperative stay of 12.5 days and follow-up of 9.5 months. The recurrence rate was 10 percent; postoperative complications included midline ischemia, infection, and dehiscence occurring at rates of 20, 40, and 43 percent, respectively. This study provides a comprehensive review of the risks and complications associated with the treatment of complex ventral hernias and those associated with abdominal "components separation."  相似文献   

8.
Ten patients underwent abdominal wall reconstruction using the technique of abdominal wall partitioning. All defects were closed in the midline by approximating fascia to fascia with the assistance of a general surgeon. One patient had skin grafted small bowel. Five patients had chronically infected mesh and previous failed attempts at repair. Four patients had large ventral hernias following gastric reduction operations and massive weight loss. No defect in any dimension was less than 20 cm. All patients had secure abdominal wall repair by reconstruction of a midline anchor for the abdominal wall musculature. One patient was lost to follow-up after 3 weeks. The average follow-up time for the remaining nine patients was 18.6 months (range, 6 months to 4.7 years). One patient required readmission to the hospital for management of a limited area of skin necrosis. Two patients had minor wound infections, and three patients had subcutaneous seromas, all of which were managed on an outpatient basis. One patient developed a 2 x 2-cm subxiphoid hernia recurrence. Technical details include subcutaneous undermining of the abdominal skin to the anterior axillary lines bilaterally, mobilization of the viscera to expose the white lines of Toldt bilaterally, and parallel, parasagittal, staggered releases of the transversalis fascia, transversalis muscle, external oblique fascia, external oblique muscle, and rectus fascia. These multiple releases allow expansion and translation of the abdominal wall by an accordion-like effect. This accordion-like effect allows closure of abdominal wall defects that are substantially larger than what can be closed with current techniques.  相似文献   

9.
Levine JP  Karp NS 《Plastic and reconstructive surgery》2001,107(3):707-16; discussion 717-8
The management of primary and recurrent giant incisional hernias remains a complex and frustrating challenge even with multiple alloplastic and autogenous closure options. The purpose of this study was to develop a reconstructive technique of restoring abdominal wall integrity to a subcategory of patients, who have failed initial hernia therapy, by performing superior and lateral myofascial release. Over a 1.5-year period, 10 patients with previously unsuccessful treatment of abdominal wall hernias, using either primary repair or placement of synthetic material, were studied. The patients had either recurrence of the hernia or complications such as infections requiring removal of synthetic material. The hernias were not able to be treated with standard primary closure techniques or synthetic material. The average defect size was 19 x 9 cm. Each patient underwent wide lysis of bowel adhesions releasing the posterior abdominal wall fascia to the posterior axillary line, subcutaneous release of the anterior abdominal wall fascia to a similar level, and complete removal of any synthetic material (if present). The abdominal domain was reestablished by releasing the laterally retracted abdominal wall. The amount of available abdominal wall tissue was increased by wide release of the cephalic abdominal wall fascia overlying the costal margin and the external oblique fascia and muscle laterally. If needed, partial thickness of the internal oblique muscle and its anterior fascia were also released laterally to perform a tension-free primary closure of the defect. All repairs were closed with satisfactory functional and aesthetic results. All alloplastic material was removed. Fascial release was limited so as to close only the hernia defect without tension. No significant release of the rectus sheath and muscle was needed. Good, dynamic muscle function was noted postoperatively. All repairs have remained intact, and no further abdominal wall hernias have been noted on follow-up.  相似文献   

10.
Staged reconstruction after gunshot wounds to the abdomen.   总被引:6,自引:0,他引:6  
Immediate closure of abdominal incisions after exploration and treatment of gunshot wounds is not always feasible or advisable. Significant bowel edema after massive fluid resuscitation might preclude primary closure, whereas any attempt to close under tension might result in complications ranging from wound dehiscence, infection, and necrosis to the abdominal compartment syndrome with abdominal, cardiopulmonary, and renal complications. For these difficult cases, the open technique has been recommended. The abdomen is left open and is closed when the patient's condition permits. When immediate wound approximation is not possible, temporary coverage can be achieved with a mesh, patch, or a split-thickness skin graft and the definitive reconstruction is deferred for a more optimal time. The purpose of this retrospective study is to report the authors' experience with staged abdominal wall reconstruction after gunshot wounds. From 1989 to 1998, 1933 patients underwent exploratory laparotomy for penetrating wounds to the abdomen. Twenty-nine patients in grave condition and with multiple medical problems were comanaged by the Trauma and Plastic Surgery Services at Cook County Hospital with the following protocol: The abdomen was initially left open and exposed viscera were covered with a variety of methods, including a Gore-Tex patch (W. L. Gore and Associates, Inc., Flagstaff, Ariz.). A split-thickness graft was subsequently placed on the granulation tissue over viscera at an average of 14 days after the last laparotomy. These planned ventral hernias were definitively treated at an average of 7 months after the skin grafting procedure, primarily using the components separation technique. In 24 patients, the fascia was closed primarily without tension, while five patients required the use of synthetic mesh to restore fascial continuity. Nine patients underwent closure of a colostomy or repair of fistulas simultaneously with abdominal wall reconstruction. One patient developed a postoperative hernia, two developed superficial wound dehiscence that healed without further surgery, and one required re-exploration for a failed anastomosis after colostomy closure. All but one patient maintained a stable abdominal wall after the reconstruction. The authors concluded that staged abdominal wall reconstruction should be primarily recommended for patients with complex abdominal wounds and a compromised general condition that precludes primary closure. With this treatment protocol, patients can recover faster from their trauma surgery and the risk of perioperative complications can be reduced. After final reconstruction, the continuity, stability, and strength of the abdominal wall are maintained in the vast majority of cases with the use of autogenous tissue and without the need for alloplastic material. With close cooperation between the trauma team and the plastic surgeon and appropriate timing and planning of each stage, the success rate of the technique is high and the incidence of complications limited.  相似文献   

11.
Abdominal wall hernias resulting from prior incisions are a common surgical complication affecting hundreds of thousands of Americans each year. The negative consequences associated with abdominal hernias may be considerable, including pain, bowel incarceration, vascular disruption, organ loss, and death. Current clinical approaches for the treatment of abdominal wall hernias focus on the implantation of permanent biomaterial meshes or acellular xenografts. However, these approaches are not infrequently associated with postoperative infections, chronic sinuses, or small bowel obstruction. Furthermore, the most critical complication, hernia recurrence, has been well described and may occur in a large percentage of patients. Despite many advances in repair techniques, wound healing and skeletal muscle regeneration is limited in many cases, resulting in a decrease in abdominal wall tissue function and contributing to the high hernia recurrence rate. This review will give an overview of skeletal muscle anatomy, skeletal muscle regeneration, and herniation mechanisms, as well as discuss the current and future clinical solutions for abdominal wall hernia repair. Birth Defects Research (Part C) 84:315–321, 2008. © 2008 Wiley‐Liss, Inc.  相似文献   

12.
This study compared Triclosan coated polyglactin 910 (Vicryl* Plus) with polyglactin 910 (Vicryl*) on abdominal wall healing in colorectal surgery patients. 184 patients with colorectal cancer were included in the study. In 91, the abdominal wall was closed with the Vicryl* Plus, and in 93 patients with Vicryl*. Demographic characteristics, biochemical inflammatory parameters, wound appearance, length of hospital stay, postoperative wound complications and post-incisional hernia were recorded. In the Vicryl* Plus group there was a shorter hospital stay (13.2 +/- 1.3 days; 21.4 +/- 2.8 respectively). In the Vicryl* Plus group inflammatory parameters decreased to normal within the first week whereas in the Vicryl* group remained increased. In the Vicryl* Plus group four patients had a wound discharge, seven had inflammatory reactions to the skin sutures. One dehiscence was noticed. In the Vicryl* group 12 patients had an SSI, 14 patients had inflammatory reactions to the skin sutures and 7 patients had a wound dehiscence. Closure of the abdominal wall using Vicryl* Plus decreases postoperative wound complications, length of hospital stay and is associated with a more rapid return of inflammatory markers to normal.  相似文献   

13.
ABSTRACT: BACKGROUND: The optimal strategy for abdominal wall closure has been an issue of ongoing debate. Available studies do not specifically enroll patients who undergo emergency laparotomy and thus do not consider the distinct biological characteristics of these patients. The present randomized controlled trial evaluates the efficacy and safety of two commonly applied abdominal wall closure strategies in patients undergoing primary emergency midline laparotomy. Methods/design The CONTINT trial is a multicenter, open label, randomized controlled trial with a twogroup parallel design. Patients undergoing a primary emergency midline laparotomy are enrolled in the trial. The two most commonly applied strategies of abdominal wall closure after midline laparotomy are compared: the continuous, all-layer suture technique using slowly absorbable monofilament material (two Monoplus(R) loops) and the interrupted suture technique using rapidly absorbable braided material (Vicryl(R) sutures). The primary endpoint within the CONTINT trial is an incisional hernia within 12 months or a burst abdomen within 30 days after surgery. As reliable data on this primary endpoint is not available for patients undergoing emergency surgery, an adaptive interim analysis will be conducted after the inclusion of 80 patients, allowing early termination of the trial if necessary or modification of design characteristics such as recalculation of sample size. DISCUSSION: This is a randomized controlled multicenter trial with a two-group parallel design to assess the efficacy and safety of two commonly applied abdominal wall closure strategies in patients undergoing primary emergency midline laparotomy. Trial registration NCT00544583.  相似文献   

14.
Reconstruction of massive abdominal wall defects has long been a vexing clinical problem. A landmark development for the autogenous tissue reconstruction of these difficult wounds was the introduction of "components of anatomic separation" technique by Ramirez et al. This method uses bilateral, innervated, bipedicle, rectus abdominis-transversus abdominis-internal oblique muscle flap complexes transposed medially to reconstruct the central abdominal wall. Enamored with this concept, this institution sought to define the limitations and complications and to quantify functional outcome with the use of this technique. During a 4-year period (July of 1991 to 1995), 22 patients underwent reconstruction of massive midline abdominal wounds. The defects varied in size from 6 to 14 cm in width and from 10 to 24 cm in height. Causes included removal of infected synthetic mesh material (n = 7), recurrent hernia (n = 4), removal of split-thickness skin graft and dense abdominal wall cicatrix (n = 4), parastomal hernia (n = 2), primary incisional hernia (n = 2), trauma/enteric sepsis (n = 2), and tumor resection (abdominal wall desmoid tumor involving the right rectus abdominis muscle) (n = 1). Twenty patients were treated with mobilization of both rectus abdominis muscles, and in two patients one muscle complex was used. The plane of "separation" was the interface between the external and internal oblique muscles. A quantitative dynamic assessment of the abdominal wall was performed in two patients by using a Cybex TEF machine, with analysis of truncal flexion strength being undertaken preoperatively and at 6 months after surgery. Patients achieved wound healing in all cases with one operation. Minor complications included superficial infection in two patients and a wound seroma in one. One patient developed a recurrent incisional hernia 8 months postoperatively. There was one postoperative death caused by multisystem organ failure. One patient required the addition of synthetic mesh to achieve abdominal closure. This case involved a thin patient whose defect exceeded 16 cm in width. There has been no clinically apparent muscle weakness in the abdomen over that present preoperatively. Analysis of preoperative and postoperative truncal force generation revealed a 40 percent increase in strength in the two patients tested on a Cybex machine. Reoperation was possible through the reconstructed abdominal wall in two patients without untoward sequela. This operation is an effective method for autogenous reconstruction of massive midline abdominal wall defects. It can be used either as a primary mode of defect closure or to treat the complications of trauma, surgery, or various diseases.  相似文献   

15.
Abdominal wall hernias are surgical problem that are easily solved with laparoscopic surgery. The determining factor for the success of the operation is the right choice and use of surgical mesh as the support material. The most common complication of surgical mesh placement is the formation of adhesions. Aim of this paper is to determine whether there is a statistic difference in formation of adhesions between different surgical meshes in lab environment. Wistar rats were used as the experimental model. After the anaesthesia a 1x1 cm defect of the abdominal wall was made, but the skin was left intact. The mesh was placed directly on the internal organs. The experiment considered four different mesh types. After set time periods of one, two or four weeks the animals were sacrificed and the amount of formed adhesions were evaluated based on the modified Diamond scale. Immediately after the first week we found a statistically significant difference in the adhesion occurrence rate between compared materials. The smallest amount of adhesions was caused by polypropylen + polydoksanon mesh, and the most by polypropilen mesh. Polypropylen + polyglactin mesh showed significant reduction of adhesion formation between the tested weeks. We can conclude that polypropylen + polydoxanon meshes are superior for ventral hernia operation, because those defects are in close contact with the internal organs and it is very important to have the smallest amount of adhesions.  相似文献   

16.
李超  黄陈 《现代生物医学进展》2015,15(34):6779-6782
腹壁疝是普外科最常见的疾病之一,主要包括腹股沟疝、切口疝、造口旁疝等,手术是其唯一的治愈方法。腹腔镜腹壁疝修 补术是在无张力疝修补术的基础上发展起来的一种微创技术,主要包括腹腔镜下腹壁疝修补术(LIHR),如经腹腔镜腹膜前补片修 补术(TAPP)和完全腹膜外补片修补术(TEP),腹腔镜下切口疝修补术及腹腔镜下造口旁疝修补术。其术后常见并发症与传统疝修 补术相同,但发生率显著低于传统的开腹疝修补术。与传统疝修补术相比,腹腔镜腹壁疝修补术具有术后疼痛轻、并发症少、疤痕 小、复发率低等优势,因此临床应用前景广阔。本文主要就腹腔镜下腹壁疝修补术的治疗现状与进展进行了综述。  相似文献   

17.
Ventral hernia repair often includes the use of structural prosthetic materials, such as polypropylene mesh, that can induce dense abdominal adhesions to peritoneal structures. AlloDerm (LifeCell Corp., Branchburg, N.J.), a commercially available decellularized human dermal analogue with its native basement membrane components intact, is gradually revascularized and replaced with autologous tissue after implantation. The authors hypothesized that AlloDerm integrated with polypropylene mesh would reduce adhesions and provide a biodegradable scaffold to generate an autologous vascularized tissue layer separating the abdominal viscera from the mesh. Ventral hernia defects (3 x 1 cm) in 19 guinea pigs were repaired using an inlay technique with polypropylene mesh alone (n = 6) or with composite implants constructed by integrating polypropylene mesh and AlloDerm with its basement membrane surface oriented toward (polypropylene/AlloIn, n = 7) or away from (polypropylene/ AlloOut, n = 6) the peritoneal cavity. At 4 weeks, the authors determined the amount of mesh implant surface area covered by adhesions, the strength of the adhesions [graded from 0 (none) to 3], and the incidence of bowel adhesions. Histologic analyses were performed on full-thickness tissue sections from the repair sites. The mean surface areas affected by adhesions and mean adhesion strength were significantly lower in the polypropylene/AlloIn (area, 12.4 percent; mean grade, 1.0) and polypropylene/AlloOut (area, 9.5 percent; mean grade, 0.5) groups than in the polypropylene group (area, 79.5 percent; mean grade, 2.9); there were no such differences between the polypropylene/AlloIn and polypropylene/AlloOut groups. The bowel was adherent to 67 percent of polypropylene repairs and 0 percent of the composite mesh repairs. The AlloDerm was remodeled to form a vascularized tissue layer beneath the mesh in composite repairs, unlike the significantly thinner, dense scar layer that formed in the polypropylene repairs. Immunohistochemical labeling for factor VIII showed neovascularization throughout the AlloDerm.The AlloDerm thus functioned as a biodegradable tissue scaffold, guiding the formation of a thick, well-vascularized tissue layer separating the polypropylene mesh from intraperitoneal structures. This significantly reduced both the amount of surface area covered by adhesions and adhesion strength. Basement membrane orientation had no effect. Composite mesh implants composed of structural prosthetic materials integrated with AlloDerm may have useful clinical applications for abdominal wall reconstruction by reducing adhesions and providing a vascularized tissue layer to separate and protect the peritoneal structures from polypropylene mesh fibers.  相似文献   

18.
19.
Frank Glassow 《CMAJ》1969,101(9):66-68
An experience with 216 bilateral hernias in female patients is reviewed. The condition is rare, occurring only once in every 250 patients admitted for a hernia repair. Bilateral primary indirect inguinal hernias were the most frequent type. Bilateral primary femoral hernias were quite rare while bilateral primary direct inguinal hernias were even more uncommon. Other rare bilateral combinations are briefly described. The incidence in children is given.Etiological factors are discussed, emphasizing the strong posterior wall of the inguinal canal in females.Two per cent of patients developed a recurrent hernia; one per cent of hernias recurred. No recurrence following a bilateral primary indirect inguinal hernia repair and no “femoral” recurrence following inguinal repair were recorded.  相似文献   

20.
Anterolateral thigh flap for abdominal wall reconstruction   总被引:5,自引:0,他引:5  
The free or pedicled anterolateral thigh flap was introduced for the reconstruction of large abdominal wall defects. This flap is superior to the tensor fasciae latae musculocutaneous flap in several respects. These include the wide, reliable skin territory (which can reach the level of the knee) and the long pedicle. Therefore, a pedicled anterolateral thigh flap with reliable blood circulation can easily be positioned above the umbilicus. In addition, the free anterolateral thigh flap has greater freedom of orientation and can be used to repair larger abdominal wall defects than can the tensor fasciae latae flap. Seven patients in whom abdominal wall defects had been reconstructed with pedicled or free anterolateral thigh flaps were reviewed. Their average age was 47.1 years (range, 21 to 74 years), and the average follow-up period was 10.7 months (range, 2 to 21 months). The size of the abdominal wall defects ranged from 12 x 12 cm to 18 x 24 cm, and the size of the transferred flap ranged from 10 x 20 cm to 20 x 20 cm. Three flaps were pedicled and four were free, of which three incorporated the tensor fasciae latae flap. All flaps survived completely, and no postoperative abdominal hernias developed. Despite some variations in vascular anatomy and technical difficulties in elevating the anterolateral thigh flap, the authors conclude that the pedicled or free anterolateral thigh flap is superior to the tensor fasciae latae flap for reconstruction of large abdominal wall defects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号