首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Naturally occurring steroids such as progesterone, testosterone and 17β-estradiol were analyzed in this study. These bio-identical molecules paradoxically can be either beneficial or harmful. Unfortunately as growth promoters can be toxic and cancerogenic at elevated levels. Due to difficulty in monitoring at trace quantities of these hormones in biological matrices specific adsorption materials molecularly imprinted polymers (MIPs) were used for preconcentration and clean up in sample preparation step. A non-covalent imprinting approach was used for bulk polymerization of progesterone, testosterone and 17β-estradiol imprinted polymers. Synthesis of MIPs was achieved by thermal, UV and γ irradiation initiated polymerization whereby were used methacrylic acid (MAA), 4-vinylpyridine (4-VP) as functional monomers, ethylene glycol dimethacrylate (EDMA), trimethylolpropane trimethacrylate (TRIM) as cross-linking agents and acetonitrile, isooctane–toluene (1:99, v/v) and chloroform as porogen solvents. It was also used as initiator 2,2′-azobis(2-methylpropionitrile) (AIBN) or benzyl methyl ether (BME). The MIPs were applied as selective sorbents in solid-phase extraction (SPE). Molecularly imprinted solid-phase extraction (MISPE) considered as hyphenated technique were applied in extraction step before HPLC-DAD analysis of steroids from human urine.  相似文献   

2.
An analytical methodology for the analysis of methamidophos in water and soil samples incorporating a molecularly imprinted solid-phase extraction process using methamidophos-imprinted polymer was developed. Binding study demonstrated that the polymer exhibited excellent affinity and high selectivity to the methamidophos. Evidence was also found by FT-IR analysis that hydrogen bonding between the CO(2)H in the polymer cavities and the NH(2) and P=O of the template was the origin of methamidophos recognition. The use of molecularly imprinted solid-phase extraction improved the accuracy and precision of the GC method and lowered the limit of detection. The recovery of methamidophos extracted from a 10.0 g soil sample at the 100 ng/g spike level was 95.4%. The limit of detection was 3.8 ng/g. The recovery of methamidophos extracted from 100 mL tap and river water at 1 ng/mL spike level was 96.1% and 95.8%, and the limits of detection were 10 and 13 ng/L respectively. These molecularly imprinted solid-phase extraction procedures enabled selective extraction of polar methamidophos successfully from water and soil samples, demonstrating the potential of molecularly imprinted solid-phase extraction for rapid, selective, and cost-effective sample pretreatment.  相似文献   

3.
In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%.  相似文献   

4.
In this study, a novel method is described for the determination of tramadol in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as the sample clean-up technique combined with high-performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and tramadol as template molecule. The novel imprinted polymer was used as a solid-phase extraction (SPE) sorbent for the extraction of tramadol from human plasma and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for the MIP cartridges were studied. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of tramadol. The limit of detection (LOD) and limit of quantification (LOQ) for tramadol in urine samples were 1.2 and 3.5 μg L−1, respectively. These limits for tramadol in plasma samples were 3.0 and 8.5 μg L−1, respectively. The recoveries for plasma and urine samples were higher than 91%.  相似文献   

5.
A novel method based on the molecularly imprinted solid-phase extraction (MISPE) procedure has been developed for the simultaneous determination of concentrations of sulfonylurea herbicides such as chlorsulfuron (CS), monosulfuron (MNS), and thifensulfuron methyl (TFM) in maize samples by liquid chromatography–tandem quadrupole mass spectrometry (LC–MS/MS). The molecularly imprinted polymer (MIP) for sulfonylurea herbicides was synthesized by precipitation polymerization using chlorsulfuron as the template molecule, 2-(diethylamino)ethyl methacrylate (DEAMA) as the functional monomer, and trimethylolpropane trimethacrylate (TRIM) as the cross-linker. The selectivities of the chlorsulfuron template and its analogs on the molecularly imprinted polymer were evaluated by high-performance liquid chromatography (HPLC). The extraction and purification procedures for the solid-phase extraction (SPE) cartridge with a molecularly imprinted polymer as the adsorbent for the selected sulfonylurea herbicides were then established. A molecularly imprinted solid-phase extraction method followed by high-performance liquid chromatography–tandem mass spectrometry for the determination of chlorsulfuron, monosulfuron, and thifensulfuron methyl was also established. The mean recoveries of these compounds in maize were in the range 75–110% and the limits of detection (LOD) of chlorsulfuron, monosulfuron, and thifensulfuron methyl were 0.02, 0.75, and 1.45 μg kg−1, respectively. It was demonstrated that the MISPE–HPLC–MS/MS method could be applied to the determination of chlorsulfuron, monosulfuron, and thifensulfuron methyl in maize samples.  相似文献   

6.
Introduction – Plant extracts are usually complex mixtures of various polarity compounds and their study often includes a purification step, such as solid‐phase extraction (SPE), to isolate interest compounds prior analytical investigations. Molecularly imprinted polymers (MIPs) are a new promising type of SPE material which offer tailor‐made selectivity for the extraction of trace active components in complex matrices. Numerous specific cavities that are sterically and chemically complementary of the target molecules, are formed in imprinted polymers. A molecularly imprinted polymer (MIP) was synthesised in order to trap a specific class of triterpene, including betulin and betulinic acid from a methanolic extract of plane bark. Methodology – Imprinted polymers were synthesised by thermal polymerisation of betulin as template, methacrylic acid (MAA) or acrylamide (AA) as functional monomer, ethylene glycol dimethacrylate as crosslinking agent and chloroform as porogen. Afterwards, MAA‐ and AA‐MIPs were compared with their non‐imprinted polymers (NIPs) in order to assess the selectivity vs betulin and its derivatives. Recovered triterpenes were analysed by HPLC during MIP‐SPE protocol. Results – After SPE optimisation, the MAA‐imprinted polymer exhibited highest selectivity and recovery (better than 70%) for betulin and best affinity for its structural analogues. Thus, a selective washing step (chloroform, acetonitrile) removed unwanted matrix compounds (fatty acids) from the SPE cartridge. The elution solvent was methanol. Finally, the MAA‐MIP was applied to fractionate a plane bark methanolic extract containing betulin and betulinic acid. Conclusion – This study demonstrated the possibility of direct extraction of betulin and its structural analogues from plant extracts by MIP technology. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Group-selective molecularly imprinted polymers (MIPs) made from sulfonamides (SAs) using functional monomer methacrylic acid (MAA) were synthesized. The derived molecularly imprinted solid-phase extraction (MISPE) cartridges were developed for the purification and enrichment of aquatic products. The optimum template molecule and the ratio of the functional monomer to the template for obtaining group selectivity to SAs were sulfadimethoxine (SDM) and 4:1, respectively. The MIPs were characterized by Brunauer-Emmett-Teller (BET), scatchard plot, and chromatography analysis, all of which demonstrate better chromatographic behavior and group-selectivity of MIPs for SAs compared with those of corresponding NIPs. The extraction conditions of MISPE for six SAs were optimized; the method precision and accuracy were satisfactory for the fish and shrimp samples at 0.05, 0.1, and 0.2 mg kg(-1) spiked levels. Recoveries ranging from 85.5% to 106.1% (RSD, 1.2-7.0%, n=3) were achieved. The limits of detection (S/N=3) and quantitation (S/N=10) in the shrimp and fish samples were achieved from 8.4 to 10.9 μg kg(-1) and from 22.4 to 27.7 μg kg(-1), respectively. Therefore, the obtained MIPs and MISPE can be employed for the enrichment and clean-up of SAs. This paper presents a new analytical method which enables the simultaneous determination and quantification of SAs in aquaculture products.  相似文献   

8.
The evaluation of molecularly imprinted polymers (MIPs) as selective sorbents for the solid-phase extraction of sildenafil and its principal metabolite, desmethylsildenafil, was investigated. Two MIPs were synthesised using structural analogues of sildenafil as templates, and a comparison of the performance of the two MIP sorbents in organic and aqueous media was performed. Additionally, the feasibility of applying molecularly imprinted solid-phase extraction (MISPE) to the clean-up of plasma samples containing sildenafil and desmethylsildenafil was investigated. A preliminary, quantitative MISPE for the determination of both compounds in plasma was also performed. The results showed that the MIPs used for the selective extraction of sildenafil gave better compound recovery when aqueous samples were used in comparison to organic-based samples. A preliminary, quantitative MISPE of sildenafil and desmethylsildenafil indicated that the imprinted materials could be used successfully as SPE sorbents for sample pre-treatment for the determination of sildenafil, and related compounds, in plasma.  相似文献   

9.
This paper reports a surface molecular self-assembly strategy for molecular imprinting on magnetic nanoparticles for selective separation and detection of estrogens in feeds. First, γ-methacryloxypropyltrimethoxysilane (MEMO) was successfully assembled at the surface magnetic nanoparticles through simple free radical polymerization, and subsequently, the copolymerization was further assembled between methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) in the presence of templates 17β-estradiol (E2). The synthesized magnetic molecularly imprinted polymers for E2 (E2-MMIPs) showed quick separation, large adsorption capacity, high selectivity and fast binding kinetics for E2. Meanwhile, a dispersive solid-phase extraction (DSPE) based on E2-MMIPs has been established for efficient separation and fast enrichment of estrogens from the feeds. The assay exhibited a linear range of 0.1-4 μM for E2 and estriol (E3) with the correlation coefficient above 0.9996 and 0.9994, respectively. Recoveries of E2 from three kinds of feeds spiked at different concentration levels ranged from 92.7% to 97.0% with RSD<4.7%, and recoveries of E3 ranged from 71.9% to 83.1% with RSD<4.9%, respectively. The method is simple and sensitive, and can be used as an alternative tool to effectively separate and enrich the trace of estrogens in agricultural products by HPLC-UV.  相似文献   

10.
A method for the analysis of enrofloxacin and ciprofloxacin in chicken muscle using marbofloxacin as internal standard is proposed. Clean-up and pre-concentration of the samples are effected by solid-phase extraction and determination is carried out by capillary electrophoresis using a photodiode array detector. The calibration graphs are linear for enrofloxacin and ciprofloxacin from 10 to 300 μg/kg. The method recoveries for enrofloxacin and ciprofloxacin are 74 and 54%, respectively. The limit of detection for the two compounds is lower than 25 μg/kg, which allows the detection of positive muscle samples at the required maximum residue limits.  相似文献   

11.
This paper describes a method for residue analysis of difloxacin and sarafloxacin in chicken muscle. Clean-up and preconcentration of the samples are effected by solid-phase extraction (C18) and the determination is carried out by capillary electrophoresis using a photodiode array detection system. The method was validated with satisfying results. The calibration graphs are linear for difloxacin and sarafloxacin from 50 to 300 microg/kg. The limit of detection obtained for difloxacin and sarafloxacin are 10 and 25 microg/kg, respectively, which allows the detection of positive muscle samples at the required maximum residue limits of European Union.  相似文献   

12.
A highly selective molecularly imprinted solid-phase extraction (MISPE) coupled with high performance liquid chromatography (HPLC) ultraviolet-visible detection was developed for the simultaneous isolation and determination of four Sudan dyes (I, II, III and IV) in catsup products. The novel molecularly imprinted microspheres (MIM) were synthesized by aqueous suspension polymerization using phenylamine and naphthol as template, which showed high affinity to Sudan dyes in aqueous solution. In order to develop a selective extraction protocol for simultaneous determination the four Sudan dyes from catsup products, the molecular recognition properties of MIM as a SPE sorbent were evaluated. Under the optimized condition, good linearity was obtained from 0.01 to 2.5 μg g(-1) (r(2)≥ 0.9990) with the relative standard deviations of less than 3.4%. This proposed MISPE-HPLC procedure eliminated the effect of template leakage on quantitative analysis and could be applied to direct determination of four Sudan dyes in complicated food samples.  相似文献   

13.
Normal and modified urinary nucleosides represent potential biomarkers for cancer diagnosis. To selectively extract modified nucleosides, we developed a molecularly imprinted polymer (MIP) of 5-methyluridine as selective material for molecularly imprinted solid-phase extraction (MISPE). The MIPs were obtained from vinyl-phenylboronate ester derivative of the template, acrylamide and pentaerythritol triacrylate co-polymer, and were tested in batch and cartridge experiments with aqueous samples. Our results indicated that the imprinted polymer was selective for pyrimidine nucleosides with a K(d) and a B(max) of 46 microM and 18 micromol/g, respectively. Finally, a MISPE of the most common pyrimidine nucleoside cancer markers in urine sample was realized.  相似文献   

14.
Andersson LI 《Bioseparation》2001,10(6):353-364
Of the many applications of molecular imprinting in analytical separation science, the one with highest potential of soon being used in routine analysis is that of solid-phase extraction. Already several examples of selective pre-concentration of biological and environmental samples have been reported. The interest in imprinted extraction sorbents originates from the high selectivities and affinities obtainable, properties which can be qualitatively and quantitatively pre-determined for a particular analyte and separation by the imprinting process. This review summarises work published on molecular imprinted solid-phase extraction and discusses some imprinted-sorbent specific method development issues.  相似文献   

15.
Ma J  Yuan L  Ding M  Wang S  Ren F  Zhang J  Du S  Li F  Zhou X 《Biosensors & bioelectronics》2011,26(5):2791-2795
In this paper, highly selective core-shell molecularly imprinted polymers of 17β-estradiol on the surface of silica nanoparticles (SiO(2)@E2-MIPs) were prepared. The SiO(2)@E2-MIPs were characterized by Fourier transform infrared spectrometer (FT-IR), transmission electron microscope (TEM), dynamic adsorption and static adsorption tests. The sorption capacity of the SiO(2)@E2-MIPs were nearly 5 times that of the non-imprinted polymers (NIPs), and it only took 25 min to achieve the sorption equilibrium. It indicated that the SiO(2)@E2-MIPs exhibited a high selectivity, large adsorption capacity and fast kinetics. When the SiO(2)@E2-MIPs were used as dispersive solid-phase extraction (dSPE) absorbents to selectively enrich and determine estrogens in duck feed, the average recoveries of E2 and estriol (E3) were higher than 96.74% and 72.07%, respectively, and the relative standard deviations (RSD) of E2 and E3 were less than 1.61% and 3.28%, respectively. The study provides an effective method for the separation and enrichment of estrogens in the complex matrix samples by the SiO(2)@E2-MIPs.  相似文献   

16.
A new analytical method for the determination of the carcinogenic mycotoxin ochratoxin A (OTA) in red wines has been developed involving a two-dimensional solid-phase extraction (SPE) clean-up protocol on C18-silica and a target-selective molecularly imprinted polymer (MIP). Prior removal of the interfering acidic matrix compounds by C18 solid-phase extraction was crucial for a successful clean-up as direct sample loading onto the MIP led to poor recoveries. The combined solid-phase extraction protocol afforded extracts suitable for sensitive ochratoxin A quantification by HPLC-fluorescence detection. Preliminary validation of the method performance with spiked (0.033-1.0 ng OTA/ml) and commercial red wines provided recoveries >90% and < 10%, with limit of detection (LOD) and limit of quantification (LOQ) of 0.01 and 0.033 ng/ml. However, a similarly favorable performance characteristics was observed in control experiments in which the MIP was replaced by the corresponding non-imprinted polymer (NIP). These findings provide evidence that under the employed experimental conditions specific analyte binding to imprinted binding sites plays a minor role in selective OTA retention. In the framework of this study, other problems inherent to MIP-based solid-phase extraction have been addressed. These include the reproducible preparation of MIP materials with consistent molecular recognition characteristics, the potential for repeated use of MIP, unfavorable polymer swelling in application-relevant solvents, potential sample contamination by template bleeding, and slow analyte binding kinetics.  相似文献   

17.
A simple, sensitive and reproducible high performance liquid chromatographic method was developed for determining valnemulin in feeds. Feed samples were extracted with ethyl acetate under alkaline condition, cleaned up by molecularly imprinted solid-phase extraction, and analyzed by high performance liquid chromatography with ultraviolet detection. The characteristics of the synthesized polymer were evaluated and the loading capacity of the polymer was about 1000 μg analyte/g imprinted polymer. The new procedure for the feed sample cleanup using the prepared polymer cartridge gave higher recoveries and fewer matrix interferences. The assay exhibited a linear dynamic range of 5.0-200 mg kg(-1) with the correlation coefficient above 0.9993. Recoveries of valnemulin from feed samples spiked at 5.0, 20 and 50 mg kg(-1) ranged between 76.0% and 94.4% with relative standard deviations of less than 9%. The limit of detection for valnemulin in feeds was 1 mg kg(-1).  相似文献   

18.
A molecularly imprinted electrochemical sensor was fabricated based on gold electrode decorated by chitosan-platinum nanoparticles (CS-PtNPs) and graphene-gold nanoparticles (GR-AuNPs) nanocomposites for convenient and sensitive determination of erythromycin. The synergistic effects of CS-PtNPs and GR-AuNPs nanocomposites improved the electrochemical response and the sensitivity of the sensor. The molecularly imprinted polymers (MIPs) were prepared by HAuCl(4), 2-mercaptonicotinic acid (MNA) and erythromycin. Erythromycin and MNA were used as template molecule and functional monomer, respectively. They were first assembled on the surface of GR-AuNPs/CS-PtNPs/gold electrode by the formation of Au-S bonds and hydrogen-bonding interactions. Then the MIPs were formed by electropolymerization of HAuCl(4), MNA and erythromycin. The sensor was characterized by cyclic voltammetry (CV), scanning electron microscope (SEM), UV-visible (UV-vis) absorption speactra and amperometry. The linear range of the sensor was from 7.0×10(-8)mol/L-9.0×10(-5)mol/L, with the limit of detection (LOD) of 2.3×10(-8)mol/L (S/N=3). The sensor showed high selectivity, excellent stability and good reproducibility for the determination of erythromycin, and it was successfully applied to the detection of erythromycin in real spiked samples.  相似文献   

19.
A review is presented of recent developments in the use of molecularly imprinted polymers (MIPs) as selective materials for solid-phase extraction. Compared with traditional sorbents, MIPs can not only concentrate but also selectively separate the target analytes from real samples, which is crucial for the quantitatively determination of analytes in complex samples. Consequently, as one of the most effective sorbents, MIPs have been successfully applied to the pretreatment of analytes in foods, drugs, and biological and environmental samples in the past five years.  相似文献   

20.
A review is presented of recent developments in the use of molecularly imprinted polymers (MIPs) as selective materials for solid-phase extraction. Compared with traditional sorbents, MIPs can not only concentrate but also selectively separate the target analytes from real samples, which is crucial for the quantitatively determination of analytes in complex samples. Consequently, as one of the most effective sorbents, MIPs have been successfully applied to the pretreatment of analytes in foods, drugs, and biological and environmental samples in the past five years.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号