 共查询到20条相似文献,搜索用时 203 毫秒
1.
Accurate characterisation of the scanner's point spread function across the entire field of view (FOV) is crucial in order to account for spatially dependent factors that degrade the resolution of the reconstructed images. The HRRT users' community resolution modelling reconstruction software includes a shift-invariant resolution kernel, which leads to transaxially non-uniform resolution in the reconstructed images. Unlike previous work to date in this field, this work is the first to model the spatially variant resolution across the entire FOV of the HRRT, which is the highest resolution human brain PET scanner in the world. In this paper we developed a spatially variant image-based resolution modelling reconstruction dedicated to the HRRT, using an experimentally measured shift-variant resolution kernel. Previously, the system response was measured and characterised in detail across the entire FOV of the HRRT, using a printed point source array. The newly developed resolution modelling reconstruction was applied on measured phantom, as well as clinical data and was compared against the HRRT users' community resolution modelling reconstruction, which is currently in use. Results demonstrated improvements both in contrast and resolution recovery, particularly for regions close to the edges of the FOV, with almost uniform resolution recovery across the entire transverse FOV. In addition, because the newly measured resolution kernel is slightly broader with wider tails, compared to the deliberately conservative kernel employed in the HRRT users' community software, the reconstructed images appear to have not only improved contrast recovery (up to 20% for small regions), but also better noise characteristics.  相似文献   

2.
PurposeTo define a method and investigate how the adjustment of scan parameters affected the image quality and Hounsfield units (HUs) on a CT scanner used for radiotherapy treatment planning. A lack of similar investigations in the literature may be a contributing factor in the apparent reluctance to optimise radiotherapy CT protocols.MethodA Catphan phantom was used to assess how image quality on a Toshiba Aquilion LB scanner changed with scan parameters. Acquisition and reconstruction field-of-view (FOV), collimation, image slice thickness, effective mAs per rotation and reconstruction algorithm were varied. Changes were assessed for HUs of different materials, high contrast spatial resolution (HCSR), contrast-noise ratio (CNR), HU uniformity, scan direction low contrast and CT dose-index.ResultsCNR and HCSR varied most with reconstruction algorithm, reconstruction FOV and effective mAs. Collimation, but not image slice width, had a significant effect on CT dose-index with narrower collimation giving higher doses. Dose increased with effective mAs. Highest HU differences were seen when changing reconstruction algorithm: 56 HU for densities close to water and 117 HU for bone-like materials. Acquisition FOV affected the HUs but reconstruction FOV and effective mAs did not.ConclusionsAll the scan parameters investigated affected the image quality metrics. Reconstruction algorithm, reconstruction FOV, collimation and effective mAs were most important. Reconstruction algorithm and acquisition FOV had significant effect on HU. The methodology is applicable to radiotherapy CT scanners when investigating image quality optimisation, prior to assessing the impact of scan protocol changes on clinical CT images and treatment plans.  相似文献   

3.
PurposeTo analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes.MethodsTo assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R).ResultsThe TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of <1.0 was almost equal to the gantry rotation time, whereas with pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/P = 0.285/1.5) and 0.074 s (R/P = 0.285/3.2), and the maximum TR values of the 64 × 0.5- and 160 × 0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/P = 0.275/1.375) and 0.195 s (R/P = 0.3/0.6), respectively.ConclusionBecause the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement.  相似文献   

4.
PurposeHybrid iterative reconstruction (IR) is useful to reduce noise in computed tomography (CT) images. However, it often decreases the spatial resolution. The ability of high spatial resolution kernels (harder kernels) to compensate for the decrease in the spatial resolution of hybrid IRs was investigated.MethodsAn elliptic cylindrical phantom simulating an adult abdomen was used. Two types of rod-shaped objects with ~330 and ~130 HU were inserted to simulate contrasts of arteries in CT angiography. Two multi-slice CT systems were used to scan the phantoms with 120 kVp and scan doses of 20 and 10 mGy. The task transfer functions (TTFs) were measured from the circular edges of the rod images. The noise power spectrum (NPS) was measured from the images of the water-only section. The CT images were reconstructed using a filtered back projection (FBP) with baseline kernels and two levels of hybrid IRs with harder kernels. The profiles of the clinical images across the aortic dissection flaps were measured to evaluate actual spatial resolutions.ResultsThe TTF degradation of each hybrid IR was recovered by the harder kernels, whereas the noise reduction effect was retained, for both the 20 and 10 mGy. The profiles of the dissection flaps for the FBP were maintained by using the harder kernels. Even with the best combination of hybrid IR and harder kernel, the noise level at 10 mGy was not reduced to the level of FBP at 20 mGy, suggesting no capability of a 50% dose reduction while maintaining noise.  相似文献   

5.
PurposeWe assessed fascicle behaviors of the upper extremities during isometric contractions at different joint angles in this study.MethodsThirteen healthy men and women performed isometric elbow extension tasks at 50% and 75% of maximal voluntary contraction (MVC) at 60°, 90°, and 120° of elbow extension (full extension = 180°). Extended field-of-view B-mode ultrasonography was used to obtain sagittal plane panoramic images of the long head (TB-Long) and medial head (TB-Med) of the triceps brachii at rest and during contraction; fascicle length and pennation angle were measured.ResultsIn the TB-Long, significant fascicle shortening from rest was found during 50% and 75%MVC at 60° and during 75%MVC at 90° of extension. There was no significant fascicle shortening in the TB-Med muscle under any conditions. There was no significant pennation angle change from rest in either muscle. The pennation angle of the TB-Long was significantly greater than that of the TB-Med under all conditions.ConclusionsThese results suggest that fascicle shortening in the TB-Long muscle occurs in flexion; however, no change was found in the TB-Med. In the upper extremity muscle–tendon complex, the superficial and deeper muscles may have different force-transmission efficiency at flexed joint angles.  相似文献   

6.
7.
PurposeAim of this work was to study how the detector resolution can affect the clinical significance of SBRT pre-treatment volumetric modulated arc therapy (VMAT) verification results.MethodsThree detectors (PTW OCTAVIUS 4D 729, 1500 and 100 SRS) used in five configurations with different resolution were compared: 729, 729 merged, 1500, 1500 merged and 1000 SRS. Absolute local gamma passing rates of 3D pre-treatment quality assurance (QA) were evaluated for 150 dose distributions in 30 plans. Five different kinds of error were introduced in order to establish the detection sensitivity of the three devices. Percentage dosimetric differences were evaluated between planned dosevolume histogram (DVH) and patients’ predicted DVH calculated by PTW DVH 4D® software. Results:The mean gamma passing rates and the standard deviations were 92.4% ± 3.7%, 94.6% ± 1.8%, 95.3% ± 4.2%, 97.4% ± 2.5% and 97.6% ± 1.4 respectively for 729, 729 merged, 1500, 1500 merged and 1000 SRS with 2% local dose/2mm criterion. The same trend was found on the sensitivity analysis: using a tight gamma analysis criterion (2%L/1mm) only the 1000 SRS detected every kind of error, while 729 and 1500 merged detected three and four kinds of error respectively. Regarding dose metrics extracted from DVH curves, D50% was within the tolerance level in more than 90% of cases only for the 1000 SRS.ConclusionsThe detector resolution can significantly affect the clinical significance of SBRT pre-treatment verification results. The choice of a detector with resolution suitable to the investigated field size is of main importance to avoid getting false positive.  相似文献   

8.
PurposeTo assess the quality of images obtained on a dual energy computed tomography (CT) scanner.MethodsImage quality was assessed on a 64 detector-row fast kVp-switching dual energy CT scanner (Revolution GSI, GE Medical Systems). The Catphan phantom and a low contrast resolution phantom were employed. Acquisitions were performed at eight different radiation dose levels that ranged from 9 mGy to 32 mGy. Virtual monochromatic spectral images (VMI) were reconstructed in the 40–140 keV range using all available kernels and iterative reconstruction (IR) at four different blending levels. Modulation Transfer Function (MTF) curves, image noise, image contrast, noise power spectrum and contrast to noise ratio were assessed.ResultsIn-plane spatial resolution at the 10% of the MTF curve was 0.60 mm−1. In-plane spatial resolution was not modified with VMI energy and IR blending level. Image noise was reduced from 16.6 at 9 mGy to 6.7 at 32 mGy, while peak frequency remained within 0.14 ± 0.01 mm−1. Image noise was reduced from 14.3 at IR 10% to 11.5 at IR 50% at a constant peak frequency. The lowest image noise and maximum peak frequency were recorded at 70 keV.ConclusionsOur results have shown how objective image quality is varied when different levels of radiation dose and different settings in IR are applied. These results provide CT operators an in depth understanding of the imaging performance characteristics in dual energy CT.  相似文献   

9.
IntroductionCutting is an important skill in team-sports, but unfortunately is also related to non-contact ACL injuries. The purpose was to examine knee kinetics and kinematics at different cutting angles.Material and methods13 males and 16 females performed cuts at different angles (45°, 90°, 135° and 180°) at maximum speed. 3D kinematics and kinetics were collected. To determine differences across cutting angles (45°, 90°, 135° and 180°) and sex (female, male), a 4 × 2 repeated measures ANOVA was conducted followed by post hoc comparisons (Bonferroni) with alpha level set at α  0.05 a priori.ResultsAt all cutting angles, males showed greater knee flexion angles than females (p < 0.01). Also, where males performed all cutting angles with no differences in the amount of knee flexion −42.53° ± 8.95°, females decreased their knee flexion angle from −40.6° ± 7.2° when cutting at 45° to −36.81° ± 9.10° when cutting at 90°, 135° and 180° (p < 0.01). Knee flexion moment decreased for both sexes when cutting towards sharper angles (p < 0.05). At 90°, 135° and 180°, males showed greater knee valgus moments than females. For both sexes, knee valgus moment increased towards the sharper cutting angles and then stabilized compared to the 45° cutting angle (p < 0.01). Both females and males showed smaller vGRF when cutting to sharper angles (p < 0.01).ConclusionIt can be concluded that different cutting angles demand different knee kinematics and kinetics. Sharper cutting angles place the knee more at risk. However, females and males handle this differently, which has implications for injury prevention.  相似文献   

10.
A theoretical model is presented for growth and remodeling in the developing embryonic heart. The model is a thick-walled tube composed of two layers of orthotropic pseudoelastic material. The analysis includes stress and strain dependent volumetric growth, with changes in material properties specified to reflect the evolving structure of the heart wall. For use in model validation, experimental measurements of ventricular opening angles are reported for 3–4-day old chick embryos under control and pressure overload conditions. Owing to changes in residual stress in the overloaded heart, the opening angle decreased from 31 ± 10° to −8 ± 12° (mean ± SD) within 12 h and then increased slightly. The opening angle at 12 h was significantly less than the control value. With an appropriate choice of parameters, the model yields reasonable agreement with these and other published opening angle data, as well as with temporal changes in lumen radius, wall thickness, epicardial strains, and pressure–volume curves during development before and after birth. Received: 26 November 2001 / Accepted: 21 December 2001  相似文献   

11.
AimTo study of 2 Dimensional ion chamber array for angular response and its utility for quality assurance of dynamic multileaf collimator and pretreatment intensity modulated radiotherapy plans.Materials and MethodsThe MLC QA test patterns and IMRT plans were executed on 2D ion chamber array having 1020 vented pixel ionization chambers. The dynamic MLC QA test patterns were chair test, x–wedge, pyramid, open swipe field, garden fence and picket fence. Performance of Dynamic wedges was compared with physical wedges. For IMRT verification, five patients with localized prostate carcinoma were planned using dynamic IMRT technique. Angular response of MatriXX was measured by exposing the system from different gantry angles.ResultsDynamic MLC QA tests such as chair, x-wedge, pyramid, and open swipe field were successfully verified. MatriXX was not able to recognize the bar pattern of picket test and garden fence test. The response of MatriXX gradually decreases from 0° to 180° angles and it was 7.7% less at 180° angle. The dynamic wedge profiles were matching with corresponding physical wedge profiles. For pretreatment IMRT QA, the average dose difference between planned and measured dose was 1.26% with standard deviation of 1.06.ConclusionI'mRT MatriXX can be used for routine dynamic MLC and IMRT pretreatment QA but care should be taken while taking measurements in penumbra region because of its limited spatial resolution.  相似文献   

12.
Poul  Larsen 《Physiologia plantarum》1969,22(3):469-488
Roots which are turned from their normal direction to directions at various angles with the plumb line develop the largest geotropic curvatures during a subsequent klinostat rotation period when the stimulation angle is well above the horizontal. In experiments with roots of Lepidium sativum L., the optimum is located at 120 to 140° when the stimulation time is between 2 and 15 min. If this fact is to be explained by the movements of amyloplasts in the root cap cells, one would expect roots which bad been kept inverted before the stimulation (so that the moveable amyloplasts are accumulated in the opposite end of the cells) to show an optimum angle well below 90°. — Pre-inversion of the roots did suppress the curvatures produced by stimulation at angles larger than 90° when measured after 10 to 30 min of klinostat rotation. This suppression may be taken as a support for the starch statolith hypothesis, since the amyloplasts in pre-inverted roots placed at angles exceeding 90° have a restricted opportunity to slide along the cell walls compared to non-inverted roots placed at the same angles. In pre-inverted roots measured after a period of klinostat rotation, however, no optimum was found at angles below 90°. When the stimulation time was 3.75 min, the response curves were nearly symmetrical about 90°. Stimulation for 15 min, on the other hand, resulted in curvatures which were much larger (although suppressed in comparison with non-inverted roots) when the stimulation angle was 165° than when it was 15°. During the 15 min stimulation period itself, however, pre-inverted roots curved 0.3° when stimulated at 15, but only 3.4° at 165°. This small difference was very highly significant and is in agreement with the starch statolith hypothesis insofar as the amyloplasts in pre-inverted roots placed at 15° have the greatest opportunity to slide along the cell walls. The lack of further development (and the actual decrease) of their curvatures during the subsequent klinostat rotation must then be due to other, depressing, factors, summarily designated as tonic. At angles above 90°, the tonic factors are either absent or even enhancing. Tbe tonic effects cannot be explained by amyloplast movements.  相似文献   

13.
PurposeWe compare image quality parameters derived from phantom images taken on three commercially available radiotherapy CT simulators. To make an unbiased evaluation, we assured images were obtained with the same surface dose measured using XR-QA2 model GafChromic™ film placed at the imaging phantom surface for all three CT-simulators.MethodsRadiotherapy CT simulators GE LS 16, Philips Brilliance Big Bore, and Toshiba Aquilion LB were compared in terms of spatial resolution, low contrast detectability, image uniformity, and contrast to noise ratio using CATPHAN-504 phantom, scanned with Head and Pelvis protocols. Dose was measured at phantom surface, with CT scans repeated until doses on all scanners were within 2%.ResultsIn terms of spatial resolution, the GE simulator appears slightly better, while Philips CT images are superior in terms of SNR for both scanning protocols. The CNR results show that Philips CT images appear to be better, except for high Z material, while Toshiba appears to fit in between the two simulators.ConclusionsWhile the image quality parameters for three RT CT simulators show comparable results, the scanner bore size is of vital importance in various radiotherapy applications. Since the image quality is a function of a large number of confounding parameters, any loss in image quality due to scanner bore size could be compensated by the appropriate choice of scanning parameters, including the exposure and by balancing between the additional imaging dose to the patient and high image quality required in highly conformal RT techniques.  相似文献   

14.
Ultra‐high resolution protein crystal structures have been considered as relatively reliable sources for defining details of protein geometry, such as the extent to which the peptide unit deviates from planarity. Chellapa and Rose (Proteins 2015; 83:1687) recently called this into question, reporting that for a dozen representative protein structures determined at ~1 Å resolution, the diffraction data could be equally well fit with models restrained to have highly planar peptides, i.e. having a standard deviation of the ω torsion angles of only ~1° instead of the typically observed value of ~6°. Here, we document both conceptual and practical shortcomings of that study and show that the more tightly restrained models are demonstrably incorrect and do not fit the diffraction data equally well. We emphasize the importance of inspecting electron density maps when investigating the agreement between a model and its experimental data. Overall, this report reinforces that modern standard refinement protocols have been well‐conceived and that ultra‐high resolution protein crystal structures, when evaluated carefully and used with an awareness of their levels of coordinate uncertainty, are powerful sources of information for providing reliable information about the details of protein geometry.  相似文献   

15.
 Most soft biological tissues, including ventricular myocardium, are not stress free when all external loads are removed. Residual stress has implications for mechanical performance of the heart, and may be an indicator of patterns of regional growth and remodeling. Cross-sectional rings of arrested ventricles opened up when a radial cut was made (initial mean opening angles were 64 ± 17°), but further circumferential cuts revealed the presence of additional residual stresses in the tissue with further opening of the rings. In normal mouse hearts, the inner half of a short-axis ring opened more than the outer half, and this change was dependent on apex–base location. At the apex the inner section vs. outer section opening angles were 226 ± 47° vs. 89 ± 28°, while at the base the same two angles were 160 ± 30° vs. 123 ± 35°. A simple theoretical cylindrical shell model with incompressible hyperelastic material properties was used to model the experimental deformations based on the cutting experiments. The model predicts different residual stress fields depending on the nature of the opening after the circumferential cut (which is done after the conventional radial cut). The observed opening angles were consistent with steep stress gradients near the endocardium compared with those predicted if the first cut was assumed to relieve all residual stresses. These results imply a more complex distribution of residual stress and strain in ventricular myocardium than previously thought. Received: 23 May 2002 / Accepted: 30 September 2002 We would like to acknowledge the surgical skills and data analysis of Zuangjie Li. This work was supported in part by National Heart, Lung, and Blood Institute Grants HL-43026 and HL-64321.  相似文献   

16.
Abstract

In this work we explore the possibility of the opening of a single base without perturbation of its neighboring nucleotides. Low energy base opening into the grooves can be accomplished by rotation of the relevant backbone and glycosidic bond torsion angles. The pathway has been determined by identifying ζ torsion angle as the reaction coordinate together with the accompanying geometric requirement that guides the displacement of other torsion angles. Our study on Dickerson dodecamer duplex d(CGCGAATTCGCG)2 showed that all bases with normal equilibrium ζ can be rotated by ~ 30°, corresponding to ~ 3.5Å base displacement, towards the major groove. Such an opening extent is comparable with estimated amplitudes of local angular motions in DNA bases from NMR experiments, which might facilitate proton exchange. The computed base opening energy barrier is also comparable with measured base pair opening enthalpy. These results indicate possible relevance of the pathway studied in this work with experimentally observed base pair opening process. Our analysis also showed a preference for base opening along the major groove and an abnormal behavior for bases with unusual equilibrium ζ torsion angle.  相似文献   

17.
18.
Background

Low back and pelvic pain is one of the most frequently reported disorders in pregnancy, however etiology and pathology of this problem have not been fully determined. The relationship between back pain experienced during pregnancy and posture remains unclear. It is challenging to measure reliably postural and spinal changes at the time of pregnancy, since most imaging studies cannot be used due to the radiation burden. 3D shape measurement, or surface topography (ST), systems designed for posture evaluation could potentially fill this void. A pilot study was conducted to test the potential of monitoring the change of spine curvatures and posture during pregnancy using surface topography. A single case was studied to test the methodology and preliminarily assess the usefulness of the procedure before performing a randomized trial. The apparatus used in this study was metrologically tested and utilized earlier in scoliosis screening.

Case presentation

The subject was measured using a custom-made structured light illumination scanner with accuracy of 0.2 mm. Measurement was taken every 2 weeks, between 17th and 37th week of pregnancy, 11 measurements in total. From the measurement the thoracic kyphosis and lumbar lordosis angles, and vertical balance angle were extracted automatically. Custom-written software was used for analysis. Oswestry Low Back Pain Disability Questionnaire (ODI) was done with every measurement. The values were correctly extracted from the measurement. The results were: 50.9 ± 2.4° for kyphosis angle, 58.1 ± 2.1° for lordosis angle and 4.7 ± 1.7° for vertical balance angle. The registered change was 7.4° in kyphosis angle, 8.4° in lordosis angle and 5.5° in vertical balance angle. The calculated ODI values were between moderate disability and severe disability (22 to 58 %).

Conclusions

This case study presents that surface topography may be suitable for monitoring of spinal curvature and posture change in pregnant women. The ionizing radiation studies are contraindicated during pregnancy. Surface topography data connected with information from pain level questionnaires allows to investigate the connection between changes in posture and back pain.

  相似文献   

19.
The impact of several physical quantities on the spatial resolution of an X-ray scintillating pixel detector for a micro cone beam CT (µCBCT) is investigated and discussed.The XtremeCT from SCANCO Medical AG was simulated using the EGSnrc/EGS++ Monte Carlo (MC) framework and extensively benchmarked in a previous work. The resolution of the detector was determined by simulating a titanium knife-edge to obtain the edge spread function (ESF) and the modulation transfer function (MTF). Propagation of the scintillation light through the scintillator and its coupling into the fiber optics system was taken into account.The contribution of particles scattered in the main scanner components to the detector signal is very low and does not affect the spatial resolution of the detector. The resolution obtained from the energy deposition in the scintillator without any blurring due to the propagation of the scintillation light into the fiber optics array was 31 µm. By assuming isotropic light propagation in the scintillator, the resolution degraded to 360 µm. A simple light propagation model taking into account the impact of the scintillator’s columnar microstructures was developed and compared with the MANTIS Monte Carlo simulation package. By reducing the width of the model’s light propagation kernel by a factor of 2 compared to the isotropic case, the detector resolution can be improved to 83 µm, which corresponds well to the measured resolution of 86 µm.The resolution of the detector is limited mainly by the propagation of the scintillation light through the scintillator layer. It offers the greatest potential to improve the resolution of the µCBCT imaging system.  相似文献   

20.
PurposeTo assess the task-based performance of images obtained under different focal spot size and acquisition mode on a dual-energy CT scanner.MethodsAxial CT image series of the Catphan phantom were obtained using a tube focus at different sizes. Acquisitions were performed in standard single-energy, high resolution (HR) and dual-energy modes. Images were reconstructed using conventional and high definition (HD) kernels. Task-based transfer function at the 50% level (TTF50%) for teflon, delrin, low density polyethylene (LDPE) and acrylic, as well as image noise and noise texture, were assessed across all focal spots and acquisition modes using Noise Power Spectrum (NPS) analysis. A non-prewhitening mathematical observer model was used to calculate detectability index (dNPW).ResultsTTF50% degraded with increasing focal spot size. TTF50% ranged from 0.67 mm−1 for teflon to 0.25 mm−1 for acrylic. For standard kernel, image noise and NPS-determined average spatial frequency were 8.3 HU and 0.29 mm−1, respectively in single-energy, 12.0 HU and 0.37 mm−1 in HR, and 7.9 HU and 0.26 mm−1 in dual-energy mode. For standard kernel, dNPW was 61 in single-energy and HR mode and reduced to 56 in dual-energy mode.ConclusionsThe task-based image quality assessment metrics have shown that spatial resolution is higher for higher image contrast materials and detectability is higher in the standard single-energy mode compared to HR and dual-energy mode. The results of the current study provide CT operators the required knowledge to characterize their CT system towards the optimization of its clinical performance.  相似文献   