首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new alternative set of elastic and inelastic cross sections has been added to the very low energy extension of the Geant4 Monte Carlo simulation toolkit, Geant4-DNA, for the simulation of electron interactions in liquid water. These cross sections have been obtained from the CPA100 Monte Carlo track structure code, which has been a reference in the microdosimetry community for many years. They are compared to the default Geant4-DNA cross sections and show better agreement with published data.In order to verify the correct implementation of the CPA100 cross section models in Geant4-DNA, simulations of the number of interactions and ranges were performed using Geant4-DNA with this new set of models, and the results were compared with corresponding results from the original CPA100 code. Good agreement is observed between the implementations, with relative differences lower than 1% regardless of the incident electron energy.Useful quantities related to the deposited energy at the scale of the cell or the organ of interest for internal dosimetry, like dose point kernels, are also calculated using these new physics models. They are compared with results obtained using the well-known Penelope Monte Carlo code.  相似文献   

2.
3.
This paper demonstrates the impact of the pre-chemical stage, especially the dissociation scheme and the associated probabilities, on water radiolysis simulation using the Geant4-DNA Monte Carlo track structure simulation toolkit. The models and parameters provided by TRACs have been collected and implemented into Geant4-DNA. In order to evaluate their influence on water radiolysis simulation, the radiochemical yields (G-values) are evaluated as a function of time and LET using the “chem6” Geant4-DNA example, and they are compared with published experimental and calculated data. The new pre-chemical models lead to a better agreement with literature data than the default pre-chemical models of Geant4-DNA, especially for OH radicals and H2O2. The revised chemistry constructor “G4EmDNAChemistry_option3” is available in Geant4-DNA version 10.7.  相似文献   

4.
Mechanistic modelling of DNA damage in Monte Carlo simulations is highly sensitive to the parameters that define DNA damage. In this work, we use a simple testing geometry to investigate how different choices of physics models and damage model parameters can change the estimation of DNA damage in a mechanistic DNA damage simulation built in Geant4-DNA. The choice of physics model can lead to variations by up to a factor of two in the yield of physically induced strand breaks, and the parameters that determine scavenging, and physical and chemical single strand break induction can have even larger consequences. Using low energy electrons as primary particles, a variety of parameters are tested in this geometry in order to arrive at a parameter set consistent with past simulation studies. We find that the modelling of scavenging can play an important role in determining results, and speculate that high-scavenging regimes, where only chemical radicals within 1 nm of DNA are simulated, could provide a good means of testing mechanistic DNA simulations.  相似文献   

5.
The use of Monte Carlo (MC) simulations remains a powerful tool to study the biological effects induced by ionizing radiation on living beings. Several MC codes are commonly used in research fields such as nanodosimetry, radiotherapy, radiation protection, and space radiation. This work presents an enhancement of an existing model [1] for radiobiological purposes, to account for the indirect DNA damage induced by ionizing particles. The Geant4-DNA simulation toolkit was used to simulate the physical, pre-chemical, and chemical stages of early DNA damage induced by protons and α-particles. Liquid water was used as the medium for simulations. Two phase-space files were generated, one containing the energy deposition events and another with the position of chemical species produced by water radiolysis from 0.1 ps up to 1 ns. These files were used as input in the radiobiological code that contains the genetic material model with atomic resolution, consisting of several copies of 30 nm chromatin fibers. The B-DNA configuration was used. This work focused on the indirect damage produced by the hydroxyl radical (OH) attack on the sugar-phosphate group. The approach followed to account for the indirect DNA damage was the same as those used by other radiobiological codes [2], [3]. The critical parameter considered here was the reaction radius, which was calculated from the Smoluchowski’s diffusion equation. Single, double, and total strand break yields produced by direct, indirect, and mixed mechanisms are reported. The obtained results are consistent with experimental and calculation data sets published in the literature.  相似文献   

6.
An extension to Geant4 Monte Carlo code was developed to take into account inter-atomic (molecular) interference effects in X-ray coherent scattering. Based on our previous works, the developed code introduces a set of form factors including interference effects for a selected variety of amorphous materials useful for medical applications, namely various tissues and plastics used to build phantoms. The code is easily upgradable in order to include new materials and offers the possibility to model a generic tissue as a combination of a set of four basic components. A dedicated Geant4 application for the simulation of X-ray diffraction experiments was created to validate the proposed upgrade of Rayleigh scattering model. A preliminary validation of the code obtained through a comparison with EGS4 and an experiment is presented, showing a satisfactory agreement.  相似文献   

7.
This review describes the PARTRAC suite of comprehensive Monte Carlo simulation tools for calculations of track structures of a variety of ionizing radiation qualities and their biological effects. A multi-scale target model characterizes essential structures of the whole genomic DNA within human fibroblasts and lymphocytes in atomic resolution. Calculation methods and essential results are recapitulated regarding the physical, physico-chemical and chemical stage of track structure development of radiation damage induction. Recent model extension towards DNA repair processes extends the time dimension by about 12 orders of magnitude and paves the way for superior predictions of radiation risks.  相似文献   

8.
Nanoparticles (NPs) have been shown to enhance X-ray radiotherapy and proton therapy of cancer. The effectiveness of radiation damage is enhanced in the presence of high atomic number (high-Z) NPs due to increased production of low energy, higher linear energy transfer (LET) secondary electrons when NPs are selectively internalized by tumour cells. This work quantifies the local dose enhancement produced by the high-Z ceramic oxide NPs Ta2O5 and CeO2, in the target tumour, for the first time in proton therapy, by means of Geant4 simulations. The dose enhancement produced by the ceramic oxides is compared against gold NPs. The energy deposition on a nanoscale around a single nanoparticle of 100 nm diameter is investigated using the Geant4-DNA extension to model particle interactions in the water medium. Enhancement of energy deposition in nano-sized shells of water, local to the NP boundary, ranging between 14% and 27% was observed for proton energies of 5 MeV and 50 MeV, depending on the NP material. Enhancement of electron production and energy deposition can be correlated to the direct DNA damage mechanism if the NP is in close proximity to the nucleus.  相似文献   

9.
Radiation therapy is an established method of cancer treatment. New technologies in cancer radiotherapy need a more accurate computation of the dose delivered in the radiotherapy treatment plan. This study presents some results of a Geant4-based application for simulation of the absorbed dose distribution given by a medical linear accelerator (LINAC). The LINAC geometry is accurately described in the Monte Carlo code with use of the accelerator manufacturer''s specifications. The capability of the software for evaluating the dose distribution has been verified by comparisons with measurements in a water phantom; the comparisons were performed for percentage depth dose (PDD) and profiles for various field sizes and depths, for a 6-MV electron beam. Experimental and calculated dose values were in good agreement both in PDD and in transverse sections of the water phantom.  相似文献   

10.
PurposeTo present a reference Monte Carlo (MC) beam model developed in GATE/Geant4 for the MedAustron fixed beam line. The proposed model includes an absolute dose calibration in Dose-Area-Product (DAP) and it has been validated within clinical tolerances for non-isocentric treatments as routinely performed at MedAustron.Material and MethodsThe proton beam model was parametrized at the nozzle entrance considering optic and energy properties of the pencil beam. The calibration in terms of absorbed dose to water was performed exploiting the relationship between number of particles and DAP by mean of a recent formalism. Typical longitudinal dose distribution parameters (range, distal penumbra and modulation) and transverse dose distribution parameters (spot sizes, field sizes and lateral penumbra) were evaluated. The model was validated in water, considering regular-shaped dose distribution as well as clinical plans delivered in non-isocentric conditions.ResultsSimulated parameters agree with measurements within the clinical requirements at different air gaps. The agreement of distal and longitudinal dose distribution parameters is mostly better than 1 mm. The dose difference in reference conditions and for 3D dose delivery in water is within 0.5% and 1.2%, respectively. Clinical plans were reproduced within 3%.ConclusionA full nozzle beam model for active scanning proton pencil beam is described using GATE/Geant4. Absolute dose calibration based on DAP formalism was implemented. The beam model is fully validated in water over a wide range of clinical scenarios and will be inserted as a reference tool for research and for independent dose calculation in the clinical routine.  相似文献   

11.
PurposeMulticellular tumor spheroids are realistic in-vitro systems used in radiation biology research to study the effect of anticancer drugs or to evaluate the resistance of cancer cells under specific conditions. When combining the modeling of spheroids together with the simulation of radiation using Monte Carlo methods, one could estimate cell and DNA damage to be compared with experimental data. We developed a Cell Population (CPOP) modeler combined to Geant4 simulations in order to tackle how energy depositions are allocated to cells, especially when enhancing radiation outcomes using high-Z nanoparticles. CPOP manages to model large three-dimensional cell populations with independent deformable cells described with their nucleus, cytoplasm and membranes together with force law systems to manage cell–cell interactions.MethodsCPOP is an opensource platform written in C++. It is divided into two main libraries: a “Modeler” library, for cell geometry modeling using meshes, and a Multi Agent System (MAS) library, simulating all agent (cell) interactions among the population. CPOP is fully interfaced with the Geant4 Monte Carlo toolkit and is able to directly launch Geant4 simulations after compilation.We modeled a full and realistic 3D cell population from SK-MEL28 melanoma cell population cultured experimentally. The spheroid diameter of 550 ± 40 µm corresponds to a population of approximately 1000 cells having a diameter of 17.2 ± 2.5 µm and a nucleus diameter of 11.2 ± 2.0 µm. We decided to reproduce cell irradiations performed with a X-RAD 320 Biological Irradiator (Precision XRay Inc., North Branford, CT).ResultsWe simulated the energy spectrum of secondary particles generated in the vicinity of the spheroid and plotted the different energy spectra recovered internally to the spheroid. We evaluated also the impact of AGuIX (Gadolinium) nanoparticles modeled into the spheroid with their corresponding secondary energy spectra.ConclusionsWe succeeded into modeling cell populations and combined them with Geant4 simulations. The next step will be to integrate DNA geometrical models into cell nuclei and to use the Geant4-DNA physics and radiolysis modeling capabilities in order to evaluate early strand breaks induced on DNA.  相似文献   

12.
The main purpose of this paper is to quantitatively study the possibility of delivering dose distributions of clinical relevance with laser-driven proton beams. A Monte Carlo application has been developed with the Geant4 toolkit, simulating the ELIMED (MEDical and multidisciplinary application at ELI-Beamlines) transport and dosimetry beam line which is being currently installed at the ELI-Beamlines in Prague (CZ). The beam line will be used to perform irradiations for multidisciplinary studies, with the purpose of demonstrating the possible use of optically accelerated ion beams for therapeutic purposes. The ELIMED Geant4-based application, already validated against reference transport codes, accurately simulates each single element of the beam line, necessary to collect the accelerated beams and to select them in energy. Transversal dose distributions at the irradiation point have been studied and optimized to try to quantitatively answer the question if such kind of beam lines, and specifically the systems developed for ELIMED in Prague, will be actually able to transport ion beams not only for multidisciplinary applications, such as pitcher-catcher nuclear reactions (e.g. neutrons), PIXE analysis for cultural heritage and space radiation, but also for delivering dose patterns of clinical relevance in a future perspective of possible medical applications.  相似文献   

13.
In this work, we used the Monte Carlo-based Geant4 simulation toolkit to calculate the ambient dose equivalents due to the secondary neutron field produced in a new projected proton therapy facility. In particular the facility geometry was modeled in Geant4 based on the CAD design. Proton beams were originated with an energy of 250 MeV in the gantry rooms with different angles with respect to the patient; a fixed 250 MeV proton beam was also modeled. The ambient dose equivalent was calculated in several locations of interest inside and outside the facility, for different scenarios. The simulation results were compared qualitatively to previous work on an existing facility bearing some similarities with the design under study, showing that the ambient dose equivalent ranges obtained are reasonable. The ambient dose equivalents, calculated by means of the Geant4 simulation, were compared to the Australian regulatory limits and showed that the new facility will not pose health risks for the public or staff, with a maximum equivalent dose rate equal to 7.9 mSv/y in the control rooms and maze exit areas and 1.3·10−1 mSv/y close to the walls, outside the facility, under very conservative assumptions. This work represents the first neutron shielding verification analysis of a new projected proton therapy facility and, as such, it may serve as a new source of comparison and validation for the international community, besides confirming the viability of the project from a radioprotection point of view.  相似文献   

14.
BackgroundGold nanoparticles (Au NPs) are regarded as potential agents that enhance the radiosensitivity of tumor cells for theranostic applications. To elucidate the biological mechanisms of radiation dose enhancement effects of Au NPs as well as DNA damage attributable to the inclusion of Au NPs, Monte Carlo (MC) simulations have been deployed in a number of studies.Scope of ReviewThis review paper concisely collates and reviews the information reported in the simulation research in terms of MC simulation of radiosensitization and dose enhancement effects caused by the inclusion of Au NPs in tumor cells, simulation mechanisms, benefits and limitations.Major conclusionsIn this review, we first explore the recent advances in MC simulation on Au NPs radiosensitization. The MC methods, physical dose enhancement and enhanced chemical and biological effects is discussed, followed by some results regarding the prediction of dose enhancement. We then review Multi-scale MC simulations of Au NP-induced DNA damages for X-ray irradiation. Moreover, we explain and look at Multi-scale MC simulations of Au NP-induced DNA damages for X-ray irradiation.General significanceUsing advanced chemical module-implemented MC simulations, there is a need to assess the radiation-induced chemical radicals that contribute to the dose-enhancing and biological effects of multiple Au NPs.  相似文献   

15.
Radiation damage to the central nervous system (CNS) has been an on-going challenge for the last decades primarily due to the issues of brain radiotherapy and radiation protection for astronauts during space travel. Although recent findings revealed a number of molecular mechanisms associated with radiation-induced impairments in behaviour and cognition, some uncertainties exist in the initial neuronal cell injury leading to the further development of CNS malfunction. The present study is focused on the investigation of early biological damage induced by ionizing radiations in a sample neural network by means of modelling physico-chemical processes occurring in the medium after exposure. For this purpose, the stochastic simulation of incident particle tracks and water radiation chemistry was performed in realistic neuron phantoms constructed using experimental data on cell morphology. The applied simulation technique is based on using Monte-Carlo processes of the Geant4-DNA toolkit. The calculations were made for proton, 12C, and 56Fe particles of different energy within a relatively wide range of linear energy transfer values from a few to hundreds of keV/μm. The results indicate that the neuron morphology is an important factor determining the accumulation of microscopic radiation dose and water radiolysis products in neurons. The estimation of the radiolytic yields in neuronal cells suggests that the observed enhancement in the levels of reactive oxygen species may potentially lead to oxidative damage to neuronal components disrupting the normal communication between cells of the neural network.  相似文献   

16.
The aim of this work was to study the influence of Geant4 parameters on dose distribution and computational time for simulations of carbon ion therapy. The study was done using Geant4 version 9.0. The dose distribution in water for incident monoenergetic carbon ion beams of 300 MeV/u were compared for different values of secondary particle production threshold and different step limits. Variations of depth dose of about 2 mm were observed in some cases, which induced a 30% variation of dose deposit in the Bragg peak region. Other tests were done using Geant4 version 9.2 to verify the results from this study. The two versions provided converging results and led to the same conclusions.  相似文献   

17.
Virtual clinical trials (VCT) are in-silico reproductions of medical examinations, which adopt digital models of patients and simulated devices. They are intended to produce clinically equivalent outcome data avoiding long execution times, ethical issues related to radiation induced risks and huge costs related to real clinical trials with a patient population. In this work, we present a platform for VCT in 2D and 3D X-ray breast imaging. The VCT platform uses Monte Carlo simulations based on the Geant4 toolkit and patient breast models derived from a cohort of high resolution dedicated breast CT (BCT) volume data sets. Projection images of the breast and three-dimensional glandular dose maps are generated for a given breast model, by simulating both 2D full-field digital mammography (DM) and 3D BCT examinations. Uncompressed voxelized breast models were derived from segmented patient images. Compressed versions of the digital breast phantoms for DM were generated using a previously published digital compression algorithm. The Monte Carlo simulation framework has the capability of generating and tracking ~105 photons/s using a server equipped with 16-cores and 3.0 GHz clock speed. The VCT platform will provide a framework for scanner design optimization, comparison between different scanner designs and between different modalities or protocols on computational breast models, without the need for scanning actual patients as in conventional clinical trials.  相似文献   

18.
In this study, Monte Carlo codes, Geant4 and MCNP6, were used to characterize the fast neutron therapeutic beam produced at iThemba LABS in South Africa. Experimental and simulation results were compared using the latest generation of Silicon on Insulator (SOI) microdosimeters from the Centre for Medical Radiation Physics (CMRP). Geant4 and MCNP6 were able to successfully model the neutron gantry and simulate the expected neutron energy spectrum produced from the reaction by protons bombarding a 9Be target. The neutron beam was simulated in a water phantom and its characteristics recorded by the silicon microdosimeters; bare and covered by a 10B enriched boron carbide converter, at different positions. The microdosimetric quantities calculated using Geant4 and MCNP6 are in agreement with experimental measurements. The thermal neutron sensitivity and production of 10B capture products in the p+ boron-implanted dopant regions of the Bridge microdosimeter is investigated. The obtained results are useful for the future development of dedicated SOI microdosimeters for Boron Neutron Capture Therapy (BNCT). This paper provides a benchmark comparison of Geant4 and MCNP6 capabilities in the context of further applications of these codes for neutron microdosimetry.  相似文献   

19.
We extended a generic Geant4 application for mechanistic DNA damage simulations to an Escherichia coli cell geometry, finding electron damage yields and proton damage yields largely in line with experimental results. Depending on the simulation of radical scavenging, electrons double strand breaks (DSBs) yields range from 0.004 to 0.010 DSB Gy−1 Mbp−1, while protons have yields ranging from 0.004 DSB Gy−1 Mbp−1 at low LETs and with strict assumptions concerning scavenging, up to 0.020 DSB Gy−1 Mbp−1 at high LETs and when scavenging is weakest. Mechanistic DNA damage simulations can provide important limits on the extent to which physical processes can impact biology in low background experiments. We demonstrate the utility of these studies for low dose radiation biology calculating that in E. coli, the median rate at which the radiation background induces double strand breaks is 2.8 × 10−8 DSB day−1, significantly less than the mutation rate per generation measured in E. coli, which is on the order of 10−3.  相似文献   

20.
A case has made for the use of Monte Carlo simulation methods when the incorporation of mutation and natural selection into Wright-Fisher gametic sampling models renders then intractable from the standpoint of classical mathematical analysis. The paper has been organized around five themes. Among these themes was that of scientific openness and a clear documentation of the mathematics underlying the software so that the results of any Monte Carlo simulation experiment may be duplicated by any interested investigator in a programming language of his choice. A second theme was the disclosure of the random number generator used in the experiments to provide critical insights as to whether the generated uniform random variables met the criterion of independence satisfactorily. A third theme was that of a review of recent literature in genetics on attempts to find signatures of evolutionary processes such as natural selection, among the millions of segments of DNA in the human genome, that may help guide the search for new drugs to treat diseases. A fourth theme involved formalization of Wright-Fisher processes in a simple form that expedited the writing of software to run Monte Carlo simulation experiments. Also included in this theme was the reporting of several illustrative Monte Carlo simulation experiments for the cases of two and three alleles at some autosomal locus, in which attempts were to made to apply the theory of Wright-Fisher models to gain some understanding as to how evolutionary signatures may have developed in the human genome and those of other diploid species. A fifth theme was centered on recommendations that more demographic factors, such as non-constant population size, be included in future attempts to develop computer models dealing with signatures of evolutionary process in genomes of various species. A brief review of literature on the incorporation of demographic factors into genetic evolutionary models was also included to expedite and stimulate further development on this theme.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号