共查询到20条相似文献,搜索用时 15 毫秒
1.
Dorenbeck U Schreyer AG Plendl PJ Hees H Feuerbach S Held P 《Birth defects research. Part A, Clinical and molecular teratology》2005,73(9):628-633
BACKGROUND: Symmelia is a rare birth defect, often combined with severe malformations of the urogenital system and the lower gastrointestinal tract. Additionally, a deformed pelvis and various degrees of separation of the lower limbs are present. CASES: We report the examination findings of 3 autopsy specimens of symmelia using magnetic resonance imaging (MRI) and computed tomography (CT) with 3-dimensional (3D) reconstructions, and conventional X-ray. CONCLUSIONS: MRI and CT with the addition of 3D visualization can be used additionally with autopsy and conventional X-ray images in the investigation of such complex anatomical abnormalities. 相似文献
2.
Lambe NR Bünger L Bishop SC Simm G Conington J 《Animal : an international journal of animal bioscience》2008,2(1):27-35
A multi-trait selection index designed to improve the overall economic performance of hill sheep, including both maternal and lamb traits, has been developed and tested in a selection experiment over 7 years. Two versions of the index were tested, with different economic weights applied to the traits, on two different hill farms: one version including maternal and growth traits; the other version with additional breeding goals of carcass weight, fatness and conformation scores. Responses to selection, using both versions of the index, suggest that improvements are being made in overall index score and lamb growth. This study investigated the indirect effects of these selection indices on lamb carcass composition and muscularity traits, as measured using X-ray computed tomography (CT) scanning. A total of 499 lambs from the two hill farms were CT scanned at weaning (approximately 120 days of age). Approximately half of the lambs from each farm were from the selection line (S, animals with highest index scores selected for breeding), while the other half were from a control line (C, animals with average index scores selected). Composition and muscularity traits were estimated on each lamb from CT data and differences between genetic lines investigated, within farm, using restricted maximum likelihood analyses, adjusting for either live weight or age. Results showed that the selection index without carcass traits produced lambs with carcass composition that was not significantly different to control lambs at a given live weight or age. Including carcass traits in the index resulted in lambs with no compositional differences (except for a slight increase in bone) at a set age compared with controls. At a given live weight however, selection lambs had less fat and lower carcass weights and killing-out percentage. Muscularity (3-D muscle shape) and muscle area shape (2-D) were not improved as a result of selection on either version of the index (including carcass weight and grades in the breeding goals or not) and, at a fixed live weight, muscularity in hind leg and lumbar regions tended to be higher in the C line. To accelerate changes in carcass composition and muscularity within the context of a multi-trait selection index for hill sheep, consideration should therefore be given to including objective CT-derived carcass traits in the index in addition to the Meat and Livestock Commission (MLC) carcass grades or ultrasound measurements. 相似文献
3.
Wuwei Ren Xosé Luís Deán-Ben Mark-Aurel Augath Daniel Razansky 《Journal of biophotonics》2021,14(2):e202000293
Optoacoustic tomography (OAT) and magnetic resonance imaging (MRI) provide highly complementary capabilities for anatomical and functional imaging of living organisms. Herein, we investigate on the feasibility of combining both modalities to render concurrent images. This was achieved by introducing a specifically-designed copper-shielded spherical ultrasound array into a preclinical MRI scanner. Phantom experiments revealed that the OAT probe caused minimal distortion in the MRI images, while synchronization of the laser and the MRI pulse sequence enabled defining artifact-free acquisition windows for OAT. Good dynamic OAT contrast from superparamagnetic iron oxide nanoparticles, a commonly used agent for MRI contrast enhancement, was also observed. The hybrid OAT-MRI system thus provides an excellent platform for cross-validating functional readings of both modalities. Overall, this initial study serves to establish the technical feasibility of developing a hybrid OAT-MRI system for biomedical research. 相似文献
4.
Blanc S Colman R Kemnitz J Weindruch R Baum S Ramsey J Schoeller D 《Journal of medical primatology》2005,34(3):130-138
Body composition estimates from dual-energy X-ray absorptiometry and stable isotope dilution ((2)H and (18)O) were compared in 61 rhesus monkeys (Macaca mulatta) from the ongoing long-term energy restriction study at the University of Wisconsin. Their average age was 18.9 +/- 2.5 y/o. Of the animals, 51% were in the energy restricted group and 38% were females. Although the correlation between methods was highly significant for fat mass (R(2) = 0.97, SEE = 0.25 kg or 7.5%, P < 0.0001) and fat-free mass (R(2) = 0.98, SEE = 0.29 kg or 3.6%, P < 0.0001), we observed that dual-energy X-ray absorptiometry underestimated fat mass by 0.67 +/- 0.26 kg (7.5%, P < 0.0001) and overestimated fat-free mass by 0.57 +/- 0.29 kg (20%, P < 0.0001) when compared with isotope dilution. Taken together with data from the literature, the present results emphasize the usefulness of dual-energy X-ray absorptiometry to derive body composition and thus nutritional status in monkeys, but demonstrate the importance of validation experiments for a given DXA model and software. 相似文献
5.
Black A Tilmont EM Baer DJ Rumpler WV Ingram DK Roth GS Lane MA 《Journal of medical primatology》2001,30(2):94-99
Accuracy of body composition measurements by dual-energy X-ray absorptiometry (DXA) was compared with direct chemical analysis in 10 adult rhesus monkeys. DXA was highly correlated (r-values > 0.95) with direct analyses of body fat mass (FM), lean mass (LM) and lumbar spine bone mineral content (BMC). DXA measurements of total body BMC were not as strongly correlated (r-value = 0.58) with total carcass ash content. DXA measurements of body FM, LM and lumbar spine BMC were not different from data obtained by direct analyses (P-values > 0.30). In contrast, DXA determinations of total BMC (TBMC) averaged 15%, less than total carcass ash measurements (P = 0.002). In conclusion, this study confirms the accurate measurement of fat and lean tissue mass by DXA in rhesus monkeys. DXA also accurately measured lumbar spine BMC but underestimated total body BMC as compared with carcass ash determinations. 相似文献
6.
Magnetic resonance imaging was used to localize the site of essential oil accumulation in fruit of Carum copticum L. (Apiaceae). A chemical shift method is described that utilized the spectral properties of the aromatic monoterpene thymol, the major component of the essential oil, to image thymol selectively. The presence of essential oil secretory structures in the fruit and an essential oil containing a high proportion of thymol were confirmed with optical microscopy and gas chromatography-mass spectrometry, respectively. Selective imaging of whole C. copticum fruits showed that thymol accumulation was localized to the secretory structures (canals) situated in the fruit wall. The technique was considered non-invasive as the seeds used in the imaging experiments remained intact and viable. 相似文献
7.
Calderan L Marzola P Nicolato E Fabene PF Milanese C Bernardi P Giordano A Cinti S Sbarbati A 《Obesity (Silver Spring, Md.)》2006,14(3):405-414
Objective: We studied ob/ob and wild‐type (WT) mice to characterize the adipose tissues depots and other visceral organs and to establish an experimental paradigm for in vivo phenotyping. Research Methods and Procedures: An in vivo evaluation was conducted using magnetic resonance imaging and 1H‐magnetic resonance spectroscopy (1H‐MRS). We used T1‐weighted images and three‐dimensional spin echo T1‐weighted images for the morphological analysis and 1H‐MRS spectra on all body mass, as well as 1H‐MRS spectra focalized on specific lipid depots [triglyceride (TG) depots] for a molecular analysis. Results: In ob/ob mice, three‐dimensional evaluation of the trunk revealed that ~64% of the volume consists of white adipose tissue, which is 72% subcutaneous and 28% visceral. In vivo 1H‐MRS showed that 20.00 ± 6.92% in the WT group and 58.67 ± 6.65% in the ob/ob group of the total proton content is composed of TG protons. In in vivo‐localized spectra of ob/ob mice, we found a polyunsaturation degree of 0.5247 in subcutaneous depots. In the liver, we observed that 48.7% of the proton signal is due to water, whereas in the WT group, the water signal amounted to 82.8% of the total proton signal. With the sequences used, the TG amount was not detectable in the brain or kidneys. Discussion: The present study shows that several parameters can be obtained by in vivo examination of ob/ob mice by magnetic resonance imaging and 1H‐MRS and that the accumulated white adipose tissue displays low polyunsaturation degree and low hydrolipidic ratio. Relevant anatomical alterations observed in urinary and digestive apparatuses should be considered when ob/ob mice are used in experimental paradigms. 相似文献
8.
Increasing attention has been focused on the use of nanostructures as contrast enhancement agents in medical imaging, especially in computed tomography (CT). To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agents for CT imaging. This study was designed to evaluate any effect on X-ray attenuation that might result from employing GNPs with a variety of shapes, sizes, surface chemistries, and concentrations. Gold nanorods (GNRs) and spherical GNPs were synthesized for this application. X-ray attenuation was quantified by Hounsfield unit (HU) in CT. Our findings indicated that smaller spherical GNPs (13 nm) had higher X-ray attenuation than larger ones (60 nm) and GNRs with larger aspect ratio exhibited great effect on X-ray attenuation. Moreover, poly ethylene glycol (PEG) coating on GNRs declined X-ray attenuation as a result of limiting the aggregation of GNRs. We observed X-ray attenuation increased when mass concentration of GNPs was elevated. Overall, smaller spherical GNPs can be suggested as a better alternative to Omnipaque, a good contrast agent for CT imaging. This data can be also considered for the application of gold nanostructures in radiation dose enhancement where nanoparticles with high X-ray attenuation are applied. 相似文献
9.
10.
Imaging of interstitial cryotherapy--an in vitro comparison of ultrasound, computed tomography, and magnetic resonance imaging. 总被引:4,自引:0,他引:4
RATIONALE AND OBJECTIVES: To evaluate the imaging capabilities of ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) in monitoring interstitial cryotherapy and to compare them with visual control. METHODS: An experimental MR-compatible, vacuum-insulated and liquid nitrogen-cooled cryoprobe was inserted under in vitro conditions into a porcine liver, which was kept at a temperature of 37 +/- 1 degrees C, in a water bath with continuous stirring. The freezing procedure was controlled macroscopically, by US (Toshiba Sonolayer, 7.5-MHz linear array transducer), by CT (Siemens Somatom Plus, slice thickness 2-8 mm, 165-210 mA at 120 kV), and by MRI (Philips Gyroscan ACS-NT, FFE TR/TE/FA = 15/5.4/25 degrees, T1-SE 550/20, T2-TSE 1800/100) after the iceball reached its maximum size. RESULTS: The maximum iceball diameter around the probe tip was 12.0 mm by visual control, 12.4 mm by US, 12.7 mm by CT, and within 12.8 mm by spin echo sequences and 11 mm by gradient echo sequence. Due to the nearly signal-free appearance of the frozen tissue on MR images, the ice/tissue contrast on T1-weighted and gradient echo images was superior to T2-weighted images and CT images. Sonographically, the ice formation appeared as a hyperechoic sickle with nearly complete acoustic shadowing. CONCLUSION: Due to the better ice/tissue contrast, T1-weighted or gradient echo MR images were superior to CT and US in monitoring interstitial cryotherapy. Gradient echo sequences generally underestimated the ice diameter by 15%. 相似文献
11.
Peter Berthold Dominik Elverfeldt Wolfgang Fiedler Jürgen Hennig Michael Kaatz Ulrich Querner 《Journal of Ornithology》2001,142(1):63-72
Summary Here we present a systematic application of magnetic resonance imaging (in the following called MRI) and magnetic resonance spectroscopy (MRS) to the White Stork. The main aim was to demonstrate the annual cycle of fat deposition in the same individuals for comparison to wild conspecifics, to clarify the energy metabolism of this migratory species. To obtain sharp, high-contrast images of the interior of the body, the birds were kept still by enclosing them in simple plastic tubes with additional fixation of legs and head, avoiding the problematic sedation with drugs. Altogether 12 test birds (young storks) were monitored systematically for 15 months, to follow seasonal changes in the internal organs (mainly breast muscles) and tissues (mainly fat depots). At each examination 22 high-contrast pixel images representing serial dorsoventral sections through the body were generated with the computer program MatLab, after which the pixels per section image were converted to tissue components in cm2 and the distances between consecutive sections used to calculate the tissue volumes in cm3. To measure the fat in the breast muscle spectroscopy was used to determine the fat : water ratio, from which changes in fat content could be derived. The study revealed pronounced seasonal changes in the visceral and cutaneous/subcutaneous fat depots, which precisely paralleled the annual variation in body weight of the birds (see also the preceding paper, Berthold et al. 2001). The breast muscles exhibited the prolonged growth typical of the juveniles of large species but no conspicuous change at the migration periods. In this project MRI and MRS proved to be successful methods that show great promise.
Magnet-Resonanz-Tomographie und -Spektroskopie der jahreszeitlichen Muster der Körperzusammensetzung: Eine methodische Pilotstudie am Weißstorch (Ciconia ciconia)
Zusammenfassung In der vorliegenden Arbeit stellen wir eine systematische Anwendung der Magnet-Resonanz-Tomographie (Kernspin-Tomographie, im Folgenden MRT) und der Magnet-Resonanz-Spektroskopie (im Folgenden MRS) am Weißstorch vor. Hauptaufgabe war es, die Jahresperiodik der Fettdeposition an denselben Individuen zu ermitteln, um Aufschluss über den Energiehaushalt dieser Zugvogelart durch Vergleiche mit freilebenden Vögeln zu bekommen. Die erforderliche Ruhigstellung der Vögel zum Erreichen scharfer kontrastreicher Bilder des Körperinneren war in einfachen Plastikröhren mit zusätzlicher Fixierung von Beinen und Kopf möglich, so dass auf die problematische Sedierung mit Narkotika verzichtet werden konnte. Insgesamt 12 Versuchsvögel (Jungstörche) wurden 15 Monate lang systematisch auf jahresperiodische Veränderungen von inneren Organen (v. a. Brustmuskeln) und Geweben (v. a. Fettdepots) untersucht. Aus je 22 seriellen kontrastreichen dorsoventralen Schnittbildern durch den Vogelkörper ließen sich mit dem Computerprogramm MatLab Pixelbilder erstellen und dann die Pixel pro Schnittbild in Gewebeanteile in cm2 umrechnen und anschließend aus den aufeinander folgenden Schnittbildern die Gewebevolumina in cm3 ermitteln. Für die Fettbestimmung im Brustmuskel wurde durch Spektroskopie das Verhältnis von Fett: Wasser bestimmt, aus dem Veränderungen des Fettgehalts abgeleitet wurden. Die Studie ergab ausgeprägte jahresperiodische Änderungen der viszeralen und kutanen/subkutanen Fettdepots, die genau parallel zum Jahresgang des Körpergewichts der Vögel verliefen (s. auch die vorangehende Arbeit, Berthold et al. 2001). Für die Brustmuskeln ergab sich ein für Jungvögel großer Arten typisches lang anhaltendes Wachstum, aber keine auffallende Veränderung zu den Zugperioden. MRT und MRS erwiesen sich in dieser Arbeit als erfolgreich und vielversprechend.相似文献
12.
Andrés Rodríguez-Galván Margarita Rivera Patricia García-López Luis A. Medina Vladimir A. Basiuk 《Journal of cellular and molecular medicine》2020,24(7):3779-3794
Gadolinium-containing carbon nanomaterials are a new class of contrast agent for magnetic resonance imaging. They are characterized by a superior proton relaxivity to any current commercial gadolinium contrast agent and offer the possibility to design multifunctional contrasts. Intense efforts have been made to develop these nanomaterials because of their potential for better results than the available gadolinium contrast agents. The aim of the present work is to provide a review of the advances in research on gadolinium-containing carbon nanomaterials and their advantages over conventional gadolinium contrast agents. Due to their enhanced proton relaxivity, they can provide a reliable imaging contrast for cells, tissues or organs with much smaller doses than currently used in clinical practice, thus leading to reduced toxicity (as shown by cytotoxicity and biodistribution studies). Their active targeting capability allows for improved MRI of molecular or cellular targets, overcoming the limited labelling capability of available contrast agents (restricted to physiological irregularities during pathological conditions). Their potential of multifunctionality encompasses multimodal imaging and the combination of imaging and therapy. 相似文献
13.
A review of the current use of magnetic resonance imaging in pregnancy and safety implications for the fetus 总被引:9,自引:0,他引:9
This paper presents an overview of the application of and risks of exposure to Magnetic Resonance Imaging (MRI) in pregnancy. It reviews the risks to the fetus by considering the hazards in terms of the three main components of an MRI system. These are the static magnetic field, the time-varying magnetic gradient fields and the pulsed radio frequency fields. The hazards discussed are biological effects, miscarriage, heating effects and acoustic noise exposure. This paper also presents a survey of MRI sites within the United Kingdom to ascertain the extent of MRI usage in pregnancy. To validate the situation of MRI in pregnancy a survey was sent to 352 MR units throughout the United Kingdom. The questions were grouped to assess (a) maternal MRI diagnosis (b) fetal MRI and (c) work practices for pregnant MRI staff. The results showed that 91% of sites were imaging pregnant women in need of diagnosis in the second and third trimester. This paper highlights that MRI can add information for fetal central nervous system abnormalities identified by ultrasound screening, however within the UK direct fetal imaging was only performed in 8% of sites. This paper indicates the need for research to be undertaken for specific MRI clinical conditions. It also advises that risk assessment for pregnant staff working in MRI is performed, and that there is a clear need for further research into the effects of MRI in pregnancy as there is a need for clear authoritive advice. 相似文献
14.
Non-invasive magnetic resonance imaging and spectroscopy techniques have been used to monitor the growth and distribution
of Chinese hamster ovary K1 cells growing in a fixed bed bioreactor composed of macroporous carriers. Diffusion-weighted 1H
magnetic resonance spectroscopy was used to monitor the volume fraction of the bioreactor occupied by the cells and diffusion-weighted
1H magnetic resonance imaging was used to map cell distribution. The imaging measurements demonstrated that cell growth in
the bioreactor was heterogeneous, with the highest cell densities being found at the surface of the carriers. The increase
in the volume fraction occupied by the cells during cell growth showed a close correlation with bioreactor ATP content measured
using 31P magnetic resonance spectroscopy. These magnetic resonance measurements, in conjunction with measurements of bioreactor
glucose consumption, allowed estimation of the specific glucose consumption rate. This declined during the culture, in parallel
with medium glucose concentration.
This revised version was published online in July 2006 with corrections to the Cover Date. 相似文献
15.
研究观察了孕期磁共振磁场照射对子代大鼠海马突触超微结构的影响。SD孕鼠妊娠第12-18d给予0.35T核磁共振(magnetic resonance imaging,MRI)磁场照射。测量1、2和5月龄雌性仔鼠海马CAl区和齿状回的突触结构参数,用立体计量学方法进行定量测定。结果显示,磁场照射可引起2月龄子代大鼠海马CAl区突触间隙增宽.齿状回突触活性区长度变短、突触界面曲率和活性区面密度减小;5月龄子代大鼠CAl区突触间隙增宽,突触后致密物变薄,突触界面曲率减小,齿状回突触间隙增宽。结果提示,妊娠期接受MRI磁场照射可引起海马突触超微结构的改变。对这些结构变化与行为损害之间的关系进行了讨论。 相似文献
16.
Functional magnetic resonance imaging of the primary motor cortex in humans: response to increased functional demands 总被引:5,自引:0,他引:5
S. Khushu S. S. Kumaran R. P. Tripathi A. Gupta P. C. Jain V. Jain 《Journal of biosciences》2001,26(2):205-215
Functional magnetic resonance imaging (fMRI) studies have been performed on 20 right handed volunteers at 1.5 Tesla using
echo planar imaging (EPI) protocol. Index finger tapping invoked localized activation in the primary motor area. Consistent
and highly reproducible activation in the primary motor area was observed in six different sessions of a volunteer over a
period of one month. Increased tapping rate resulted in increase in the blood oxygenation level dependent (BOLD) signal intensity
as well as the volume/area of activation (pixels) in the contra-lateral primary motor area up to tapping rate of 120 taps/min
(2 Hz), beyond which it saturates. Activation in supplementary motor area was also observed. The obtained results are correlated
to increased functional demands. 相似文献
17.
S. de Haan K. de Boer J. Commandeur A. M. Beek A. C. van Rossum C. P. Allaart 《Netherlands heart journal》2014,22(10):449-455
Objective
Implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy (CRT) have substantially improved the survival of patients with cardiomyopathy. Eligibility for this therapy requires a left ventricular ejection fraction (LVEF) <35 %. This is largely based on studies using echocardiography. Cardiac magnetic resonance imaging (CMR) is increasingly utilised for LVEF assessment, but several studies have shown differences between LVEF assessed by CMR and echocardiography. The present study compared LVEF assessment by CMR and echocardiography in a heart failure population and evaluated effects on eligibility for device therapy.Methods
152 patients (106 male, mean age 65.5 ± 9.9 years) referred for device therapy were included. During evaluation of eligibility they underwent both CMR and echocardiographic LVEF assessment. CMR volumes were computed from a stack of short-axis images. Echocardiographic volumes were computed using Simpson’s biplane method.Results
The study population demonstrated an underestimation of end-diastolic volume (EDV) and end-systolic volume (ESV) by echocardiography of 71 ± 53 ml (mean ± SD) and 70 ± 49 ml, respectively. This resulted in an overestimation of LVEF of 6.6 ± 8.3 % by echocardiography compared with CMR (echocardiographic LVEF 31.5 ± 8.7 % and CMR LVEF 24.9 ± 9.6 %). 28 % of patients had opposing outcomes of eligibility for cardiac device therapy depending on the imaging modality used.Conclusion
We found EDV and ESV to be underestimated by echocardiography, and LVEF assessed by CMR to be significantly smaller than by echocardiography. Applying an LVEF cut-off value of 35 %, CMR would significantly increase the number of patients eligible for device implantation. Therefore, LVEF cut-off values might need reassessment when using CMR. 相似文献18.
M. Panigel T. Dixon I. Constantinidis S. Sheppard R. Swenson H. McLure W.E. Campbell J. Huddleston B. Polliotti A. Nahmias 《Journal of medical primatology》1993,22(7-8):393-399
Fast scan magnetic resonance imaging, color Doppler ultrasonography, and magnetic resonance angiography were used to demonstrate the uteroplacental hemodynamics in rhesus monkeys. “Jets” of maternal blood spurting into the placenta were observed with, or without, the use of a contrast medium from 114 days to the term of pregnancy. Cumulative intravenous doses of cocaine hydrochloride brought about changes in the sequences of imaging of the maternal blood inflow to the placenta. These methods appear suitable for non-invasive monitoring of the effects of drugs on placental function. 相似文献
19.