1.
The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20–630 cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within ±3% when compared with those measured with a parallel plate chamber. From 4 to 12 MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600 MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23–40 °C. The energy dependence of a MOSFET dosimeter was within ±3.0% for 6–18 MeV electron beams and 5.5% for 4 MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4–18 MeV.  相似文献   

2.
AimTo assess the performance of the monitor unit (MU) Objective tool in Eclipse treatment planning system (TPS) utilizing volumetric modulated arc therapy (VMAT) for rectal cancer.BackgroundEclipse VMAT planning module includes a tool to control the number of MUs delivered: the MU Objective tool. This tool could be utilized to reduce the total number of MUs in rectal cancer treatments.Materials and methods20 rectal cancer patients were retrospectively studied using VMAT and the MU Objective tool. The baseline plan for each patient was selected as the one with no usage of the MU Objective tool. The number of MUs of this plan was set to be the reference number of MUs (MUref). Five plans were re-optimized for each patient only varying the Max MU parameter. The selected values were 30%, 60%, 90%, 120% and 150% of MUref for each patient. Differences with respect to the baseline plan were evaluated regarding MU number and parameters for PTVs coverage evaluation, PTVs homogeneity and OARs doses assessment. A two-tailed, paired-samples t-test was used to quantify these differences.ResultsAverage relative differences in MU number obtained was 10% for Max MU values of 30% and 60% of MUref, respectively (p < 0.03). PTVs coverage and homogeneity were not compromised and discrepancies obtained with respect to baseline plans were not significant. Furthermore, maximum OARs doses deviations were also not significant.ConclusionsA 10% reduction in the MU number could be obtained without an alteration of PTV coverage and OARs doses for rectal cancer.  相似文献   

3.
PurposeWe analysed the effects of field size, depth, beam modifier and beam type on the amount of in-field and out-of-field neutron contamination for medical linear accelerators (linacs).MethodsMeasurements were carried out for three high-energy medical linacs of Elekta Synergy Platform, Varian Clinac DHX High Performance and Philips SL25 using bubble detectors. The photo-neutron measurements were taken in the first two linacs with 18 MV nominal energy, whereas the electro-neutrons were measured in the three linacs with 9 MeV, 10 MeV, 15 MeV and 18 MeV.ResultsThe central neutron doses increased with larger field sizes as a dramatic drop off was observed in peripheral areas. Comparing with the jaws-shaped open-field of 10 × 10 cm, the motorised and physical wedges contributed to neutron contamination at central axis by 60% and 18%, respectively. The similar dose increment was observed in MLC-shaped fields. The contributions of MLCs were in the range of 55–59% and 19–22% in Elekta and Varian linacs comparing with 10 × 10 and 20 × 20 cm open fields shaped by the jaws, respectively. The neutron doses at shallow depths were found to be higher than the doses found at deeper regions. The electro-neutron dose at the 18 MeV energy was higher than the doses at the electron energies of 15 MeV and 9 MeV by a factor of 3 and 50, respectively.ConclusionThe photo- and electro-neutron dose should be taken into consideration in the radiation treatment with high photon and electron energies.  相似文献   

4.
Stimulation of motor units (MUs) with repeated pulses evokes tetanic contractions, which consist of overlapping mechanical responses. The summation of these responses into tetanus is a nonlinear process due to the dynamic changes in the amplitudes and time parameters of the successive components. In order to study these changes, two MUs (one fast and one slow) of rat medial gastrocnemius muscle were stimulated with a progressively increasing number of pulses, from one (i = 1) to sixteen (i = 16) at a frequency of 15 Hz for the slow MU and 60 Hz for the fast MU. The individual responses were calculated by subtracting the (i)th from the (i + 1)th tetanus recording. The contractions obtained following subtraction were modeled using a novel 6-parameter analytical function. The main conclusions of this study are (1) the newly presented analytical function is able to precisely describe the variable shape of all subtracted experimental contractions; (2) the shapes of successive contractions are variable and the subtracted contractions differ from the individual twitches; (3) as the pulse number increases, the parameters of the subtracted contractions change in a different manner for the slow and fast MUs: for the slow MU, the maximal forces and the time parameters increase considerably up to the 4th response, after which they remain nearly constant or show only a slight increase; for the fast MU, the maximal forces and durations also increase, whereas the remaining time parameters initially increase and then maintain a constant level or decrease, which explains the sag phenomenon visible in the unfused tetanus of fast MUs.  相似文献   

5.
The contractile properties of motor units (MUs) were electrophysiologically investigated in the medial gastrocnemius (MG) muscle in 17 Wistar three-month-old female rats: 14, 30, 90 and 180 days after the total transection of the thoracic spinal cord and compared to those in intact (control) rats. A sag phenomenon, regularly observed in unfused tetani of fast units in intact animals at 40 Hz stimulation, almost completely disappeared in spinal rats. Therefore, the MUs of intact and spinal rats were classified as fast or slow types basing on 20 Hz tetanus index, the value of which was lower or equal 2.0 for fast and higher than 2.0 for slow MUs. The MUs composition of MG muscle changed with time after the spinal cord transection: an increasing proportion of fast fatigable (FF) units starting one month after injury and a disappearance of slow (S) units within the three months were observed. In all MUs investigated the twitch contraction and half-relaxation time were significantly prolonged after injury (p < 0.01, Mann–Whitney U-test). Moreover, a decrease of the fatigue index for fast resistant (FR) and slow MUs was observed in subsequent groups of spinal rats. No significant changes were found between twitch forces in all MU types of spinal animals (p > 0.05). However, due to a decrease of the maximal tetanic force, a significant rise of the twitch-to-tetanus ratio of all MUs in spinal rats was detected (p < 0.01). The considerable reduction of ability to potentiate the force was noticed for fast, especially FF type MUs. In conclusion, the spinal cord transection leads to changes in the proportion of the three MU types in rat MG muscle. The majority of changes in MUs’ contractile properties were developed progressively with time after the spinal cord injury. However, the most intensive alterations of twitch-time parameters were observed in rats one month after the transection.  相似文献   

6.
During a voluntary contraction, motor units (MUs) fire a train of action potentials, causing summation of the twitch forces, resulting in fused or unfused tetanus. Twitches have been important in studying whole-muscle contractile properties and differentiation between MU types. However, there are still knowledge gaps concerning the voluntary force generation mechanisms. Current methods rely on the spike-triggered averaging technique, which cannot track changes in successive twitches’ properties in response to individual neural firings. This study proposes a method that estimates successive twitches contractile parameters of single MUs during low force voluntary isometric contractions in human biceps brachii. We used a previously developed ultrafast ultrasound imaging method to estimate unfused tetanic activity signals of single MUs. A twitch decomposition model was used to decompose unfused tetanic activity signals into individual twitches. This study found that the contractile parameters varied within and across MUs. There was an association between the inter-spike interval and the contraction time (r = 0.49, p < 0.001) and the half-relaxation time (r = 0.58, p < 0.001), respectively. The method shows the proof-of-concept to study MU contractile properties of individual twitches in vivo, which can provide further insights into the force generation mechanisms of voluntary contractions and response to individual neural discharges.  相似文献   

7.
New version 13.6.23 of the electron Monte Carlo (eMC) algorithm in Varian Eclipse™ treatment planning system has a model for 4 MeV electron beam and some general improvements for dose calculation. This study provides the first overall accuracy assessment of this algorithm against full Monte Carlo (MC) simulations for electron beams from 4 MeV to 16 MeV with most emphasis on the lower energy range. Beams in a homogeneous water phantom and clinical treatment plans were investigated including measurements in the water phantom. Two different material sets were used with full MC: (1) the one applied in the eMC algorithm and (2) the one included in the Eclipse™ for other algorithms. The results of clinical treatment plans were also compared to those of the older eMC version 11.0.31. In the water phantom the dose differences against the full MC were mostly less than 3% with distance-to-agreement (DTA) values within 2 mm. Larger discrepancies were obtained in build-up regions, at depths near the maximum electron ranges and with small apertures. For the clinical treatment plans the overall dose differences were mostly within 3% or 2 mm with the first material set. Larger differences were observed for a large 4 MeV beam entering curved patient surface with extended SSD and also in regions of large dose gradients. Still the DTA values were within 3 mm. The discrepancies between the eMC and the full MC were generally larger for the second material set. The version 11.0.31 performed always inferiorly, when compared to the 13.6.23.  相似文献   

8.
The purpose of this study was to investigate whether age-related changes in motor unit (MU) contractile properties are reflected in parameters of motor unit action potentials (MUAPs). MUs of the medial gastrocnemius muscle were functionally isolated in anaesthetized Wistar rats. A control group of young animals (5–10 mo) was compared to two groups of old rats (24–25 mo and 28–30 mo). The basic contractile properties of MUs as well as the amplitude, total duration, peak-to-peak time, and number of turns within MUAPs were measured. Effects of aging were mainly observed for fast fatigable MUs (a prolongation of MUAPs and increased number of turns). The MUAP amplitude did not change significantly with aging in either MU type, but it correlated to the twitch or tetanic forces, which tended to increase with age, especially for slow MUs. We concluded that the prolongation of MUAPs and the greater incidence of signal turns was probably a result of a decrease in muscle fiber conduction velocity and/or an increase in their dispersion, and enlargement of MU territories – presumably caused by axonal sprouting of surviving motoneurons. The latter might also be responsible for the observed age-related tendency for a increase in MUAP amplitudes in slow MUs.  相似文献   

9.
AimThe investigation of the irradiation time calculation accuracy of the GGPB algorithm used for IORT.BackgroundConventionally, breast conserving therapy consists of breast conserving surgery followed by postoperative whole breast irradiation and boost. The use of intraoperative radiotherapy (IORT) enables the boost to be delivered already during the surgery. In this case, the treatment dose for IORT can be calculated by use of General Gaussian Pencil Beam (GGPB) algorithm, which is implemented in TPS Eclipse.Materials and methodsPDDs and OFs for electron beams from Mobetron and all available applicators were measured in order to configure the GGPB algorithm. Afterwards, the irradiation times for the prescribed dose of 3 Gy were calculated by means of it. The results of calculations were verified in the water phantom using the Marcus ionization chamber.ResultsThe results differed between energies. For 6 MeV the irradiation times calculated by the GGPB algorithm were correct, for the energy of 9 MeV they were too small and for the energy of 4 MeV they were too large for applicators with smaller diameters, while acceptable for the remaining ones.ConclusionThe GGPB algorithm can be used in intraoperative radiotherapy for energy and applicator sets for which no significant difference between the measured and the prescribed dose was obtained. For the rest of energy-applicator sets the configuration should be verified and possibly repeated.  相似文献   

10.
IntroductionWe aimed to determine whether the changes in muscle activity (in terms of both gross electromyography (EMG) and motor unit (MU) discharge characteristics) observed during pain are spatially organized with respect to pain location within a muscle which is the main contributor of the task.MethodsSurface and fine-wire EMG was recorded during matched low-force isometric plantarflexion from soleus (from four quadrants with fine-wire EMG and from the medial/lateral sides with surface EMG), both gastrocnemii heads, peroneus longus, and tibialis anterior. Four conditions were tested: two control conditions that each preceded contractions with pain induced in either the lateral (PainL) or medial (PainM) side of soleus.ResultsNeither the presence (p = 0.28) nor location (p = 0.19) of pain significantly altered gross muscle activity of any location (lateral/medial side of soleus, gastrocnemii, peroneus longus and tibialis anterior). Group data from 196 MUs show redistribution of MU activity throughout the four quadrants of soleus, irrespective of pain location. The significant decrease of MU discharge rate during pain (p < 0.0001; PainL: 7.3 ± 0.9–6.9 ± 1.1 Hz, PainM: 7.0 ± 1.1 to 6.6 ± 1.1 Hz) was similar for all quadrants of the soleus (p = 0.43), regardless of the pain location (p = 0.98). There was large inter-participant variation in respect to the characteristics of the altered MU discharge with pain.ConclusionResults from both surface and fine-wire EMG recordings do not support the hypothesis that muscle activity is reorganized in a simple systematic manner with respect to pain location.  相似文献   

11.
PurposeIn the current era of MRI-linac radiotherapy, dose optimization with arbitrary dose distributions is a reality. For the first time, we present new and targeted experiments and modeling to aid in evaluating the potential dose improvements offered with an electron beam mode during MRI-linac radiotherapy.MethodsSmall collimated (1 cm diameter and 1.5 × 1.5 cm2 square) electron beams (6, 12 and 20 MeV) from a clinical linear accelerator (Varian Clinac 2100C) are incident perpendicular and parallel to the strong and localized magnetic fields (0–0.7 T) generated by a permanent magnet device. Gafchromic EBT3 film is placed inside a slab phantom to measure two-dimensional dose distributions. A benchmarked and comprehensive Monte Carlo model (Geant4) is established to directly compare with experiments.ResultsWith perpendicular fields a 5% narrowing of the beam FWHM and a 10 mm reduction in the 15% isodose penetration is seen for the 20 MeV beam. In the inline setup the penumbral width is reduced by up to 20%, and a local central dose enhancement of 100% is observed. Monte Carlo simulations are in agreement with the measured dose distributions (2% or 2 mm).ConclusionA new range of experiments have been performed to offer insight into how an electron beam mode could offer additional choices in MRI-linac radiotherapy. The work extends on historic studies to bring a successful unified experimental and Monte Carlo modeling approach for studying small field electron beam dosimetry inside magnetic fields. The results suggest further work, particularly on the inline magnetic field scenario.  相似文献   

12.
AimTo examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values.BackgroundAccelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered in high conformal dynamic techniques.Materials and methodsDose calculation was done for two different beam rates (100 MU/min and 600 MU/min) in an IMRT plan. For both, a comparison of Radiation Planning Index (RPI) and MU was conducted. Secondly, the comparison of optimal fluence maps and corresponding actual fluence maps was done. Next, actual fluence maps were measured and compared with the calculated ones. Gamma index was used for that assessment. Additionally, positions of each leaf of the MLC were controlled by home made software.ResultsDose distribution obtained for lower beam rates was slightly better than for higher beam rates in terms of target coverage and risk structure protection. Lower numbers of MUs were achieved in 100 MU/min plans than in 600 MU/min plans. Actual fluence maps converted from optimal ones demonstrated more similarity in 100 MU/min plans. Better conformity of the measured maps to the calculated ones was obtained when a lower beam rate was applied. However, these differences were small. No correlation was found between quality of fluence map conversion and leaf motion accuracy.ConclusionExecution of dynamic techniques is dependent on beam rate. However, these differences are minor. Analysis shows a slight superiority of a lower beam rate. It does not significantly affect treatment accuracy.  相似文献   

13.
Doherty, Timothy J., and William F. Brown. Age-relatedchanges in the twitch contractile properties of human thenar motorunits. J. Appl. Physiol. 82(1):93-101, 1997.The purpose of this study was to examine theeffects of aging on the contractile and electrophysiological propertiesof human thenar motor units (MUs). Percutaneous electrical stimulationof single motor axons within the median nerve was used to isolate andexamine the twitch tensions, contractile speeds, and surface-detectedMU action potential (S-MUAP) sizes of 48 thenar MUs in 17 youngersubjects (25-53 yr) and 44 thenar MUs in 9 older subjects(64-77 yr). A wide range of twitch tensions, contractile speeds,and S-MUAP sizes was observed in both age groups. However, oldersubjects had significantly larger MU twitch tensions and slower MUtwitch contraction and half-relaxation times. These changes wereaccompanied by increased S-MUAP sizes. These findings suggest that thehuman thenar MU pool undergoes significant age-related increase in MUsize and slowing of contractile speed. Such adaptation may help toovercome previously reported age-related losses of thenar MUs.

  相似文献   

14.
PurposeTo characterize a synthetic diamond dosimeter (PTW Freiburg microDiamond 60019) in high dose-per-pulse electron beams produced by an Intra Operative Radiation Therapy (IORT) dedicated accelerator.MethodsThe dosimetric properties of the microDiamond were assessed under 6, 8 and 9 MeV electron beams by a NOVAC11 mobile accelerator (Sordina IORT Technologies S.p.A.).The characterization was carried out with dose-per-pulse ranging from 26 to 105 mGy per pulse. The microDiamond performance was compared with an Advanced Markus ionization chamber and a PTW silicon diode E in terms of dose linearity, percentage depth dose (PDD) curves, beam profiles and output factors.ResultsA good linearity of the microDiamond response was verified in the dose range from 0.2 Gy to 28 Gy. A sensitivity of 1.29 nC/Gy was measured under IORT electron beams, resulting within 1% with respect to the one obtained in reference condition under 60Co gamma irradiation. PDD measurements were found in agreement with the ones by the reference dosimeters, with differences in R50 values below 0.3 mm. Profile measurements evidenced a high spatial resolution of the microDiamond, slightly worse than the one of the silicon diode. The penumbra widths measured by the microDiamond resulted approximately 0.5 mm larger than the ones by the Silicon diode. Output factors measured by the microDiamond were found within 2% with those obtained by the Advanced Markus down to 3 cm diameter field sizes.ConclusionsThe microDiamond dosimeter was demonstrated to be suitable for precise dosimetry in IORT applications under high dose-per-pulse conditions.  相似文献   

15.
PurposeTo quantify relative merit of MU deprived plans against freely optimized plans in terms of plan quality and report changes induced by progressive resolution optimizer algorithm (PRO3) to the dynamic parameters of RapidArc.Materials and methodsTen cases of carcinoma hypopharynx were retrospectively planned in three phases without using MU tool. Replicas of these baseline plans were reoptimized using “Intermediate dose” feature and “MU tool” to reduce MUs by 20%, 35%, and 50%. Overall quality indices for target and OAR, integral dose, dose-volume spread were assessed. All plans were appraised for changes induced in RapidArc dynamic parameters and pre-treatment quality assurance (QA).ResultsWith increasing MU reduction strength (MURS), MU/Gy values reduced, for all phases with an overall range of 8.6–34.7%; mean dose rate decreased among plans of each phase, phase3 plans recorded greater reductions. MURS20% showed good trade-off between MUs and plan quality. Dose-volume spread below 5 Gy was higher for baseline plans while lower between 20 and 35 Gy. Integral dose was lower for MURS0%, not exceeding 1.0%, compared against restrained plans. Mean leaf aperture and control point areas increased systematically, correlated negatively with increasing MURS. Absolute delta dose rate variations were least for MURS0%. MU deprived plans exhibited GAI (>93%), better than MURS0% plans.ConclusionBaseline plans are superior to MU restrained plans. However, MURS20% offers equivalent and acceptable plan quality with mileage of MUs, improved GAI for complex cases. MU tool may be adopted to tailor treatment plans using PRO3.  相似文献   

16.
PurposeTo evaluate the flat-panel detector quenching effect and clinical usability of a flat-panel based compact QA device for PBS daily constancy measurements.Materials & MethodThe QA device, named Sphinx Compact, is composed of a 20x20 cm2 flat-panel imager mounted on a portable frame with removable plastic modules for constancy checks of proton energy (100 MeV, 150 MeV, 200 MeV), Spread-Out-Bragg-Peak (SOBP) profile, and machine output. The potential quenching effect of the flat-panel detector was evaluated. Daily PBS QA tests of X-ray/proton isocenter coincidence, the constancy of proton spot position and sigma as well as the energy of pristine proton beam, and the flatness of SOBP proton beam through the 'transformed' profile were performed and analyzed. Furthermore, the sensitivity of detecting energy changes of pristine proton beam was also evaluated.ResultsThe quenching effect was observed at depths near the pristine peak regions. The flat-panel measured range of the distal 80% is within 0.9 mm to the defined ranges of the delivered proton beams. X-ray/proton isocenter coincidence tests demonstrated maximum mismatch of 0.3 mm between the two isocenters. The device can detect 0.1 mm change of spot position and 0.1 MeV energy changes of pristine proton beams. The measured transformed SOBP beam profile through the wedge module rendered as flat.ConclusionsEven though the flat-panel detector exhibited quenching effect at the Bragg peak region, the proton range can still be accurately measured. The device can fulfill the requirements of the daily QA tests recommended by the AAPM TG224 Report.  相似文献   

17.
BackgroundHigh-energy photon and electron therapeutic beams generated in medical linear accelerators can cause the electronuclear and photonuclear reactions in which neutrons with a broad energy spectrum are produced. A low-energy component of this neutron radiation induces simple capture reactions from which various radioisotopes originate and in which the radioactivity of a linac head and various objects in the treatment room appear.AimThe aim of this paper is to present the results of the thermal/resonance neutron fluence measurements during therapeutic beam emission and exemplary spectra of gamma radiation emitted by medical linac components activated in neutron reactions for four X-ray beams and for four electron beams generated by various manufacturers’ accelerators installed in typical concrete bunkers in Polish oncological centers.Materials and methodsThe measurements of neutron fluence were performed with the use of the induced activity method, whereas the spectra of gamma radiation from decays of the resulting radioisotopes were measured by means of a portable high-purity germanium detector set for field spectroscopy.ResultsThe fluence of thermal neutrons as well as resonance neutrons connected with the emission of a 20 MV X-ray beam is ~106 neutrons/cm2 per 1 Gy of a dose in water at a reference depth. It is about one order of magnitude greater than that for the 15 MV X-ray beams and about two orders of magnitude greater than for the 18–22 MeV electron beams regardless of the type of an accelerator.ConclusionThe thermal as well as resonance neutron fluence depends strongly on the type and the nominal potential of a therapeutic beam. It is greater for X-ray beams than for electrons. The accelerator accessories and other large objects should not be stored in a treatment room during high-energy therapeutic beam emission to avoid their activation caused by thermal and resonance neutrons. Half-lives of the radioisotopes originating from the simple capture reaction (n,γ) (from minutes to hours) are long enough to accumulate radioactivity of components of the accelerator head. The radiation emitted by induced radioisotopes causes the additional doses to staff operating the accelerators.  相似文献   

18.
19.
The contractile properties of motor units (MUs) were investigated in the medial gastrocnemius (MG) muscle in rats after the spinal cord hemisection at a low thoracic level. Hemisected animals were divided into 4 groups: 14, 30, 90 and 180 days after injury. Intact rats formed a control group. The mass of the MG muscle did not change significantly after spinal cord hemisection, hind limb locomotor pattern was almost unchanged starting from two weeks after injury, but contractile properties of MUs were however altered. Contraction time (CT) and half-relaxation time (HRT) of MUs were prolonged in all investigated groups of hemisected rats. The twitch-to-tetanus ratio (Tw/Tet) of fast MUs after the spinal cord hemisection increased. For slow MUs Tw/Tet values did not change in the early stage after the injury, but significantly decreased in rats 90 and 180 days after hemisection. As a result of hemisection the fatigue resistance especially of slow and fast resistant MU types was reduced, as well as fatigue index (Fat I) calculated for the whole examined population of MUs decreased progressively with the time. After spinal cord hemisection a reduced number of fast MUs presented the sag at frequencies 30 and 40 Hz, however more of them revealed sag in 20 Hz tetanus in comparison to control group. Due to considerable changes in twitch contraction time and disappearance of sag effect in unfused tetani of some MUs in hemisected animals, the classification of MUs in all groups of rats was based on the 20 Hz tetanus index (20 Hz Tet I) but not on the standard criteria usually applied for MUs classification. MU type differentiations demonstrated some clear changes in MG muscle composition in hemisected animals consisting of an increase in the proportion of slow MUs (likely due to an increased participation of the studied muscle in tonic antigravity activity) together with an increase in the percentage of fast fatigable MUs.  相似文献   

20.
In electron radiotherapy, shielding material is required to attenuate beam and scatter. A newly introduced shielding material, tungsten functional paper (TFP), has been anticipated to become a very useful device that is lead-free, light, flexible, and easily processed, containing very fine tungsten powder at as much as 80% by weight. The purpose of this study was to investigate the dosimetric changes due to TFP shielding for electron beams. TFP (thickness 0–15 mm) was placed on water or a water-equivalent phantom. Percentage depth ionization and transmission were measured for 4, 6, and 9 MeV electron beams. Off-center ratio was also measured using film dosimetry at depth of dose maximum under similar conditions. Then, beam profiles and transmission with two shielding materials, TFP and lead, were evaluated. Reductions of 95% by using TFP at 0.5 cm depth occurred at 4, 9, and 15 mm with 4, 6, and 9 MeV electron beams, respectively. It is found that the dose tend to increase at the field edge shaped with TFP, which might be influenced by the thickness. TFP has several unique features and is very promising as a useful tool for radiation protection for electron beams, among others.  相似文献   