首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method using an atmospheric pressure chemical ionization source (APCI) for the quantification of fenretinide (4-HPR) in mouse plasma was developed and validated. After a simple protein precipitation of plasma sample by acetonitrile, 4-HPR was analyzed by LC-APCI-MS/MS. High-performance liquid chromatography (HPLC) separation was conducted on a Hypurity C18 column (50mmx2.1mm, 5microm) with a flow rate 0.60mL/min using a gradient mobile phase comprised of 0.05% formic acid in water (A) and methanol (B), and a run time of 4.5min. The elimination of a tedious sample preparation process and a shorter run time substantially reduced total analysis time. The method was linear over the range 0.5-100ng/mL, with r>0.998. The intra- and inter-assay precisions were 1.4-9.2% and 5.1-8.2%, respectively, and the intra- and inter-assay accuracies were 93.9-98.6% and 92.7-95.3%, respectively. The absolute recoveries were 90.3% (1.5ng/mL), 97.0% (7.5ng/mL) and 92.1% (75.0ng/mL) for 4-HPR, and 99.1% for the internal standard (150ng/mL). The analytical method had excellent sensitivity using a small sample volume (30microL) with the lower limit of quantification (LLOQ) 0.5ng/mL. This method is robust and has been successfully employed in a pharmacokinetic study of 4-HPR in a mouse xenograft model of neuroblastoma.  相似文献   

2.
A simple, sensitive and specific high-performance liquid chromatography (HPLC) assay for the quantification of camptothecin (CPT), a potent anticancer candidate, incorporated into solid lipid nanoparticles (SLN) in several rat organs (brain, heart, kidneys liver, lung, spleen) and serum was developed and validated. The sample pre-treatment involved organs homogenisation followed by CPT extraction. The samples were injected onto an analytical reversed-phase (RP) Mediterranea? Sea18 column maintained at 30°C. The chromatographic separation was achieved by gradient elution consisting of triethyamine buffer pH 5.5 and acetonitrile at a flow rate of 1.2 mL/min in 16 min of run time and retention time of 9.8 min (lactone). Fluorescence detection was used at the excitation and emission of 360 and 440 nm, respectively. The calibration curves in the different organs, serum and in PB3 were linear (r(2)>0.9999) over CPT concentrations ranging from 1 to 200 ng/mL or 0.5 to 200 ng/mL (n=6), respectively. The method was shown to be specific, accurate (between 94.4±4.5% and 108.9±0.6%) and precise at the intra-day and inter-day levels as reflected by the coefficient of variation (CV<6.3%) at three different concentrations (10, 50 and 100 ng/mL) in all matrices. Stability studies showed that CPT was stable in all matrices after 24h of incubation at room temperature (RT), after 24 h in the autosampler or after three freeze/thaw cycles. The mean recoveries of CPT in suspension, loaded into SLN and in a physical mixture with SLN at three concentrations of 10, 50 and 200 ng/mL were higher than 86.4%. The detection limit (DL) was ≤0.2 ng/mL and the quantification limit (QL) was ≤0.5 ng/mL. The method developed is reliable, precise and accurate and can be used in the determination of CPT amount in rat organ samples after i.v. administration of CPT in suspension, in physical mixture with SLN and incorporated in SLN.  相似文献   

3.
建立HPLC同时测定伤科黄水中6个生物碱的方法。采用XBridge C18色谱柱(3. 5μm,2. 1 mm×100 mm),柱温35℃,测定波长280 nm,以0. 1%磷酸溶液(每100 mL加0. 3 g十二烷基苯磺酸钠)(A)-乙腈-水-磷酸-十二烷基苯磺酸钠(90∶10∶0. 1∶0. 3)(B)为流动相,进行梯度洗脱(0~30 min,B%:35~70; 30~31 min,B%:70~35; 31~40min,B%:35)。经方法学验证,黄柏碱、药根碱、表小檗碱、黄连碱、巴马汀、小檗碱等共6个生物碱分离情况良好,在测定时间段内无明显干扰峰;加样回收率均在95%~115%之间,RSD%均小于5%;精密度RSD%均小于5%;在测定浓度范围内(1~50μg/mL)线性关系良好,相关系数(R^2)大于0. 999。3个不同批次供试品的测定结果较一致。本研究建立的HPLC分析方法可用于同时测定伤科黄水中6个生物碱的含量。  相似文献   

4.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

5.
[Arg6, d-Trp7,9, mePhe8]-substance P (6–11), code-named antagonist G, is a novel peptide currently undergoing early clinical trials as an anticancer drug. A sensitive, high efficiency high-performance liquid chromatography (HPLC) method is described for the determination in human plasma of antagonist G and its three major metabolites, deamidated-G (M1), G-minus Met11 (M2) and G[Met11(O)] (M3). Gradient elution was employed using 40 mM ammonium acetate in 0.15% trifluoroacetic acid as buffer A and acetonitrile as solvent B, with a linear gradient increasing from 30 to 100% B over 15 min, together with a microbore analytical column (μBondapak C18, 30 cm×2 mm I.D.). Detection was by UV at 280 nm and the column was maintained at 40°C. Retention times varied by <1% throughout the day and were as follows: G, 13.0 min; M1, 12.2 min; M2, 11.2 min; M3, 10.8 min, and 18.1 min for a pyrene conjugate of G (G–P). The limit of detection on column (LOD) was 2.5 ng for antagonist G, M1–3 and G–P and the limit of quantitation (LOQ) was 20 ng/ml for G and 100 ng/ml for M1–3. Sample clean-up by solid-phase extraction using C2-bonded 40 μm silica particles (Bond Elut, 1 ml reservoirs) resulted in elimination of interference from plasma constituents. Within-day and between-day precision and accuracy over a broad range of concentrations (100 ng/ml–100 μg/ml) normally varied by <10%, although at the highest concentrations of M1 and M2 studied (50 μg/ml), increased variability and reduced recovery were observed. The new assay will aid in the clinical development of antagonist G.  相似文献   

6.
A simple, rapid and validated high performance liquid chromatography method with UV detection for the quantification of an opioid agonist, fentanyl (FEN), in rat plasma was developed. The assay procedure involved chromatographic separation using a ZIC-HILIC SeQUANT column (250 mm × 4.6 mm, i.d., 5 μm) and a mobile phase of acetonitrile and acetate buffer (pH 3.4, 20mM) of ratio (=65:35, v/v) at a flow rate of 1.2 mL/min and detection wavelength of 201 nm. Plasma sample (100 μL) pretreatment was based on simple deprotienization by acetonitrile spiked with clonidine as an internal standard (I.S.) of 20 ng/mL followed by extraction with tert-butyl methyl ether and centrifugation. The organic layer was evaporated under N(2) gas and reconstituted with 100 μL of acetate buffer (pH 3.4, 20mM), and 50-μL portions of reconstituted sample were injected onto the column. Sample analysis including sample pretreatment was achieved within 35 min. Calibration curve was linear (r ≥ 0.998) from 5 to 100 ng/mL. Both intra- and inter-day assay precisions that are presented through RSD were lower than 12.6% for intra-day and lower than 12.0% for inter-day assessment. Limit of detection was 0.8 ng/mL at S/N of 3. This method was omitting the use of expensive solid phase extraction and time consuming liquid extraction procedures. Moreover, the present method was successfully applied to study pharmacokinetic parameters of FEN after intraperitoneal administration to male Wistar rat. Pharmacokinetic parameters estimated by using moment analysis were T(1/2) 198.3 ± 44.7 min, T(max) 28.3 ± 2.9 min and AUC(0-180) 15.6 ± 2.9(× 10(2))ngmin/mL.  相似文献   

7.
A robust and simple method for absolute quantification of a novel bidirectional immunomodulatory drug candidate, cyclic thymic hexapeptide (cTP6), in rhesus monkey plasma was developed and validated by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Plasma proteins were precipitated by adding four volumes of acetonitrile. Peptides in the supernatant were separated by liquid chromatography on an Agilent Zorbax Eclipse Plus-C18 chromatographic column with gradient elution using 0.1% formic acid in water (mobile phase A) and 0.1% formic acid in methanol (mobile phase B) at 0.2 mL/min. The analytes were identified by triple quadrupole mass spectrometry in positive ion-mode. The assay was linear over a concentration range of 10-5000 ng/mL for cTP6, with a lower limit of quantification (LLOQ) of 10 ng/mL. Intra- and inter-day precision of the assay at three concentrations were 1.51-7.70% with accuracy of 95.1-104.2%. The average recovery of cTP6 for three concentration levels was 59.6-64.0%. No significant matrix effect was observed. Peptide cTP6 was detected in plasma of live rhesus monkeys up to 6-8h after intra-muscular injection. The half-life was 2.24-2.95 h. The result revealed a nonlinear pharmacokinetic response to increasing doses of cTP6 (100, 200, 500 μg/kg). For the multiple dose study of cTP6, the drug did not accumulate during daily administration at 100 μg/kg for 7 consecutive days in rhesus monkeys.  相似文献   

8.
Angus (n=6), Brangus (5/8 Angus x 3/8 Brahman, n=6), and Brahman x Angus (3/8 Angus x 5/8 Brahman, n=6) heifers exhibiting estrous cycles at regular intervals were used to determine if the percentage of Bos indicus breeding influenced the secretory patterns of LH in response to a GnRH treatment on Day 6 of the estrous cycle. Heifers were pre-synchronized with a two-injection PGF(2 alpha) protocol (25 mg i.m. Day -14 and 12.5 mg i.m. Day -3 and -2 of experiment). Heifers received 100 microg GnRH i.m. on Day 6 of the subsequent estrous cycle. Blood samples were collected at -60, -30, and -1 min before GnRH and 15, 30, 60, 90, 120, 150, 180, 240, 300, 360, 420, and 480 min after GnRH to determine concentrations of serum LH. Estradiol concentrations were determined at -60, -30, and -1 min before GnRH. On Day 6 and 8, ovaries were examined by ultrasonography to determine if ovulation occurred. On Day 13, heifers received 25 mg PGF(2 alpha) i.m. and blood samples were collected daily until either the expression of estrus or Day 20 for heifers not exhibiting estrus to determine progesterone concentrations. There was no effect (P>0.10) of breed on ovulation rate to GnRH as well as size of the largest follicle, mean estradiol, and mean corpus luteum volume at GnRH. Mean LH was greater (P<0.05) for Angus (7.0+/-0.8 ng/mL) compared to Brangus (4.6+/-0.8 ng/mL) and Brahman x Angus (2.9+/-0.8 ng/mL), which were similar (P>0.10). Mean LH peak-height was similar (P>0.10) for Brangus (13.9+/-3.4 ng/mL) compared to Angus (21.9+/-3.4 ng/mL) and Brahman x Angus (8.0+/-3.4 ng/mL), but was greater (P<0.05) for Angus compared to Brahman x Angus. Interval from GnRH to LH peak was similar (P>0.10) between breeds. As the percentage of Bos indicus breeding increased the amount of LH released in response to GnRH on Day 6 of the estrous cycle decreased.  相似文献   

9.
建立了高效液相色谱测定罗汉果根中两个结构新颖的降三萜糖苷,罗汉果酸苷乙Ⅱ(Siraitic acidⅡB)和罗汉果酸苷甲Ⅱ(Siraitic acidⅡA)含量的方法。色谱条件:色谱柱:ZORBAX SB-C18柱(4.6mm×150mm,5μm);柱温:25℃;流动相:乙腈-水(梯度洗脱:0→4min:35%乙腈;4→16min:35%→45%乙腈);流速:0.5mL/min;检测波长:230nm;进样量:10μL。结果表明,罗汉果酸苷乙Ⅱ在0.05~0.3mg/mL,罗汉果酸苷甲Ⅱ在0.05~0.25mg/mL之间线性关系良好。该方法稳定,精密度、重现性好,且样品处理简单,提取与检测时间短。  相似文献   

10.
A sensitive and reliable high performance liquid chromatography-tandem time-of-flight mass spectrometry method (HPLC/TOF MS) has been developed to determine three active bufadienolides from Liu-Shen-Wan (LSW) in dog's plasma. Enhanced selectivity and sensitivity in comparison with traditional HPLC/DAD method could be obtained through this method. Bufodienolides could be well separated and distinguished from its nominally isobaric endogenous components by HPLC/TOF MS, with the linear calibration range covering from 0.5 ng/mL to 100 ng/mL and Limit of Detection (LOD) being about 0.15 ng/mL. This method was also proved to be quite stable, with the intra-day precision and the inter-day precision results being lower than 6.39% and 7.44%, respectively. Meanwhile HPLC/TOF MS was successfully used in the pharmacokinetic study of LSW. For resibufogenin, the major pharmacokinetic parameters AUC0-t, Cmax and t1/2alpha were 160.72+/-21.97 ng/mL min, 2.35+/-0.71 ng/mL and 20.74+/-5.89 min, respectively, and for bufalin the corresponding parameters were 55.55+/-7.55 ng/mL min, 0.91+/-0.15 ng/mL and 25.45+/-13.28 min, respectively.  相似文献   

11.
[Arg6, -Trp7,9, mePhe8]-substance P (6–11), code-named antagonist G, is a novel peptide currently undergoing early clinical trials as an anticancer drug. A sensitive, high efficiency high-performance liquid chromatography (HPLC) method is described for the determination in human plasma of antagonist G and its three major metabolites, deamidated-G (M1), G-minus Met11 (M2) and G[Met11(O)] (M3). Gradient elution was employed using 40 mM ammonium acetate in 0.15% trifluoroacetic acid as buffer A and acetonitrile as solvent B, with a linear gradient increasing from 30 to 100% B over 15 min, together with a microbore analytical column (μBondapak C18, 30 cm×2 mm I.D.). Detection was by UV at 280 nm and the column was maintained at 40°C. Retention times varied by <1% throughout the day and were as follows: G, 13.0 min; M1, 12.2 min; M2, 11.2 min; M3, 10.8 min, and 18.1 min for a pyrene conjugate of G (G–P). The limit of detection on column (LOD) was 2.5 ng for antagonist G, M1–3 and G–P and the limit of quantitation (LOQ) was 20 ng/ml for G and 100 ng/ml for M1–3. Sample clean-up by solid-phase extraction using C2-bonded 40 μm silica particles (Bond Elut, 1 ml reservoirs) resulted in elimination of interference from plasma constituents. Within-day and between-day precision and accuracy over a broad range of concentrations (100 ng/ml–100 μg/ml) normally varied by <10%, although at the highest concentrations of M1 and M2 studied (50 μg/ml), increased variability and reduced recovery were observed. The new assay will aid in the clinical development of antagonist G.  相似文献   

12.
We examined the effect of three daily foot-shock stress sessions on glucose homeostasis, insulin secretion by isolated pancreatic islets, insulin sensitivity of white adipocytes, and glycogen stores in the liver and soleus muscle of rats. Stressed rats had plasma glucose (128.3 +/- 22.9 mg/dL) and insulin (1.09 +/- 0.33 ng/mL) levels higher than the controls (glucose, 73.8 +/- 3.5 mg/dL; insulin, 0.53 +/- 0.11 ng/mL, ANOVA plus Fisher's test; p < 0.05). After a glucose overload, the plasma glucose, but not insulin, levels remained higher (area under the curve 8.19 +/- 1.03 vs. 4.84 +/- 1.33 g/dL 30 min and 102.7 +/- 12.2 vs. 93.2 +/- 16.1 ng/mL 30 min, respectively). Although, the area under the insulin curve was higher in stressed (72.8 +/- 9.8 ng/mL) rats than in control rats (34.9 +/- 6.9 ng/mL) in the initial 10 min after glucose overload. The insulin release stimulated by glucose in pancreatic islets was not modified after stress. Adipocytes basal lipolysis was higher (stressed, 1.03 +/- 0.14; control, 0.69 +/- 0.11 micromol of glycerol in 60 min/100 mg of total lipids) but maximal lipolysis stimulated by norepinephrine was not different (stressed, 1.82 +/- 0.35; control, 1.46 +/- 0.09 micromol of glycerol in 60 min/100 mg of total lipids) after stress. Insulin dose-dependently inhibited the lipolytic response to norepinephrine by up to 35% in adipocytes from control rats but had no effect on adipocytes from stressed rats. The liver glycogen content was unaltered by stress, but was lower in soleus muscle from stressed rats than in control rats (0.45 +/- 0.04 vs. 0.35 +/- 0.04 mg/100 mg of wet tissue). These results suggest that rats submitted to foot-shock stress develop hyperglycemia along with hyperinsulinemia as a consequence of insulin subsensitivity in adipose tissue, with no alteration in the pancreatic sensitivity to glucose. Foot-shock stress may therefore provide a useful short-term model of insulin subsensitivity.  相似文献   

13.
A rapid, sensitive and specific method to determination of ambroxol in human plasma using high performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-MS/ESI) was described. Ambroxol and the internal standard (I.S.), fentanyl, were extracted from plasma by N-hexane-diethyl ether (1:1, v/v) after alkalinized with ammonia water. A centrifuged upper layer was then evaporated and reconstituted with 100 microl mobile phase. Chromatographic separation was performed on a BDS HYPERSIL C18 column (250 mmx4.6 mm, 5.0 microm, Thermo electron corporation, USA) with the mobile phase consisting of 30 mM ammonium acetate (0.4% formic acid)-acetonitrile (64:36, v/v) at a flow-rate of 1.2 mL min(-1). The total run time was 5.8 min for each sample. Detection and quantitation was performed by the mass spectrometer using selected ion monitoring at m/z 261.9, 263.8 and 265.9 for ambroxol and m/z 337.3 for fentanyl. The calibration curve was linear within the concentration range of 1.0-100.0 ng mL(-1) (r=0.9996). The limit of quantification was 1.0 ng mL(-1). The extraction recovery was above 83.3%. The methodology recovery was higher than 93.8%. The intra- and inter-day precisions were less than 6.0%. The method is accurate, sensitive and simple for the study of the pharmacokinetics and metabolism of ambroxol.  相似文献   

14.
Dye-binding protein assay using a long-wave-absorbing cyanine probe   总被引:2,自引:0,他引:2  
A simple and fast protein assay that involves the binding of water-soluble sulfonate heptamethylene cyanine to protein is described. The binding of the dye to protein causes a shift in the absorption maximum of the dye from 778 to 904 nm, and the increase in absorption at 904 nm is monitored. This assay is very reproducible, of good color stability for at least 80 min, and sensitive at the 100 ng/mL level of human serum albumin (HSA) when a spectrophotometer with near-infrared wavelength is used to measure absorbance. Few chemicals except ionic surfactants such as cetyltrimethylammonium bromide and sodium dodecyl sulfonate interfere with the assay. Purified proteins have different capacities to interact with the dye; under the experimental conditions, the linear ranges of bovine serum albumin (BSA), HSA and gamma-IgG were 200-2000, 100-2400, and 200-3000 ng/mL, respectively. The relative standard deviation for the five replicate determinations of 1200 ng/mL BSA is 2.1%.  相似文献   

15.
A simple and sensitive liquid chromatography/positive-ion electrospray ionization mass spectrometry (LC-ESI-MS/MS) method has been developed for the simultaneous determination of sulphasalazine (SASP) and its main metabolite sulphapyridine (SP) and 5-aminosalicylic acid (5-ASA) with 100 μL of human plasma using dimenhydrinate as the internal standard (I.S.). The API-3000 LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Protein precipitation process was used to extract SASP, SP, 5-ASA and I.S. from human plasma. The total run time was 9.0 min and the elution of SASP, SP and 5-ASA was at 4.8 min, 2.5 min and 2.0 min, respectively. The separation was achieved with a mobile phase consisting of 0.2% formic acid, 2 mM ammonium acetate in water (mobile phase A) and 0.2% formic acid, 2 mM ammonium acetate in methanol (mobile phase B) by using gradient elution on a XBP Phenyl column (100 mm × 2.1 mm, 5 μm). The developed method was validated in human plasma with a lower limit of quantitation of 10 ng/mL for SASP, SP and 5-ASA, respectively. A linear response function was established for the range of concentrations 10-10,000 ng/mL (r>0.99) for SASP and 10-1000 ng/mL (r>0.99) for SP and 5-ASA. The intra and inter-day precision values for SASP, SP and 5-ASA met the acceptance as per FDA guidelines. SASP, SP and 5-ASA were stable during stability studies, i.e., long term, auto-sampler and freeze/thaw cycles. The method was successfully applied for the evaluation of pharmacokinetics of SASP, SP and 5-ASA after single oral doses of 250 mg SASP to 10 healthy volunteers.  相似文献   

16.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

17.
Two kinds of monoclonal antibodies (MoAbs), OCA-10A and OCA-1B, were prepared based on their specificity to ochratoxin A (OTA) and ochratoxin B (OTB) and on their tolerance to 40% methanol. In an indirect competitive enzyme-linked immunosorbent assay, the half maximal inhibitory concentration (IC(50)) value of OCA-10A was 27ng/mL for OTA and 17ng/mL for OTB, and that of OCA-1B was 28ng/mL for OTA and 13ng/mL for OTB. Immuno-affinity columns (IACs) using these MoAbs were prepared with agarose gel beads. The IAC with OCA-1B showed a NaCl-dependent binding ability to OTA and OTB, while interestingly, the IAC with OCA-10A bound to them without NaCl. The IAC with OCA-10A showed a high methanol tolerance when compared with existing IACs, as expected from the high methanol tolerance of OCA-10A itself. Such tolerance was maintained for the application of the cocoa extract with 70% methanol and the wheat extract with 60% acetonitrile, while the tolerance was slightly altered by interference from the cocoa extract. Examinations with organic solvents at higher concentrations than the allowable level in existing IACs showed that OTA and OTB spiked with wheat, cocoa and red wine could be purified with high recovery. The newly developed IAC is expected to show sufficient clean-up ability for food analyses.  相似文献   

18.
A method for measurement of an important biological marker, 1,1'-sulfonylbis[2-(methylthio)ethane] (SBMTE) of sulfur mustard agent HD [bis-(2-chloroethyl)sulfide] in human urine, to quantify HD exposure, is presented. It employs TiCl3 reduction of beta-lyase metabolites to SBMTE, and automated solid-phase extraction sample preparation, followed by isotope dilution liquid chromatography-positive ion-electrospray ionization-tandem mass spectrometry with 7.5 min/sample cycle time, to achieve SBMTE quantitation of up to 200 samples/24h a day. Percent relative standard deviations over the calibration range varied from 12.0% at 0.1 ng/mL to 0.9% at 100 ng/mL, and the limit of detection from a 0.5 mL sample was below the lowest level calibration standard of 0.1 ng/mL.  相似文献   

19.
We had previously shown that selective thromboxane synthetase inhibition with furegrelate increases urinary excretion of 6-ketoPGF1 alpha, the hydrolysis product of prostacyclin after stimulation of renal prostaglandin synthesis with furosemide. The present study assessed the functional significance of this "redirection" of prostaglandin formation using a more physiologic stimulus, angiotensin II. Sprague-Dawley rats (n = 27) were fitted with a transabdominal bladder cannula. Five days later they were given angiotensin II (10 mg.kg-1.min-1) by intravenous infusion. After 30 min, an infusion of furegrelate, 2 mg/kg, then 2 mg.kg-1.h-1, (n = 9); indomethacin, 2 mg/kg, then 2 mg.kg-1.h-1 (n = 9); or vehicle, 250 microL, then 0.018 mL/min (n = 9) was begun for 60 min. Clearance of [14C]para-aminohippuric acid was taken as a measure of renal plasma flow. Angiotensin II raised the mean arterial pressure in all groups. Administration of furegrelate or indomethacin did not change mean arterial pressure or heart rate. Angiotensin II reduced [14C]p-aminohippuric acid clearance by about 32% (1.42 +/- 0.18 to 0.97 +/- 0.07 mL.min-1.100 g-1, p less than 0.05). Furegrelate attenuated this renal vasoconstriction (0.97 +/- 0.07 to 1.38 +/- 0.17 mL.min-1.100 g-1, p less than 0.05), while indomethacin increased it by a further 32% (1.78 +/- 0.12 to 1.20 +/- 0.12 mL.min-1.100 g-1, p less than 0.05). Vehicle alone had no effect. Furegrelate reduced serum thromboxane B2 by 90% (6.52 +/- 0.030 to 0.7 +/- 0.21 ng/100 microL, p less than 0.05), while indomethacin reduced it by 73% (5.9 +/- 0.99 to 1.4 +/- 0.20 ng/100 microL, p less than 0.05). We conclude that furegrelate attenuates the renal vasoconstriction of angiotensin II, presumably by enhancing the formation of vasodilator prostaglandins.  相似文献   

20.
Matrix metalloproteinases (MMP) degrade myocardial fibrillar collagen in acute myocardial infarction (MI) patients. Their activity is tightly controlled in normal myocardium by a family of closely related tissue inhibitors known as TIMP. An imbalance in their activity might contribute to post-MI remodeling. Plasma levels of MMP-1, TIMP-1 and MMP-1/TIMP-1 complex were measured, using relevant ELISA kits, in 24 (22 males-2 females), acute MI patients with a mean age 59 +/- 14 years. Blood samples were taken on admission (0 h), and 3 h, 6 h, 9 h, 18 h, 24 h, 36 h, 48 h, 3rd, 4th, 5th, 7th, 15th, 30th days after MI. All patients underwent coronary arteriography with ventriculography for estimation of left ventricular ejection fraction (LVEF) and extent of coronary artery diseases, and echocardiographic study for measuring end-diastolic diameter (EDD). Ten patients with an LVEF < 45%, an EDD > 47.5 mm, and heart failure symptoms were included in group A and compared against 12 patients with an LVEF > 45% an EDD < 47.5 mm in group B. Mean plasma concentrations of MMP-1 were higher by 21% in group A (1.3 +/- 0.2 ng/mL) compared to group B (1 +/- 0.1 ng/mL) over the total study period. TIMP-1 plasma concentrations showed very little difference between the 2 groups, (704 +/- 213 ng/mL versus 691 +/- 165 ng/mL, (6%)). Finally, plasma concentrations of MMP-1/TIMP-1 complex were lower by -36% in group A with a mean value of 2.7 +/- 0.6 ng/mL versus 3.7 +/- 0.5 ng/mL in group B. Mean values for the differences were significant at time points 0, 6, 18, 24 and 48 hours for MMP-1 (p < 0.036), and on 48 h and the 4th day for MMP-1/TIMP-1 complex (p < 0.031). Moreover, a good correlation was found between plasma concentrations of creatine kinase (CK) and MMP-1 at 18 h (r = 0.422, p = 0.041) and on the 4th day (r = 0.67, p = 0.046), and TIMP-1 on the 4th day (r = 0.67, p = 0.047). Additionally, mean values for LVEF were 35.8 +/- 8.8% in group A versus 51.2 +/- 1.8% (p = 0.00014) in group B. Also, the EDD in-group A was 52.1 +/- 6.9 mm versus 42.9 +/- 3.2 mm in group B (p = 0.00013). In acute MI patients, increased MMP-1, with no change in TIMP-1, is associated with left ventricular dysfunction and dilatation, suggesting that increased collagenolytic activity contributes to loss of LV function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号