首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Supercritical fluid chromatography (SFC) is already used for enantioseparation in the pharmaceutical industry, but it is rarely used for the separation of chiral pesticides. Comparing with high performence liquid chromatography, SFC uses much more environmnetal friendly and economic mobile phase, supercritical CO2. In our work, the enantioseparation of an amide herbicide, napropamide, using three different polysaccharide‐type chiral stationary phases (CSPs) in SFC was investigated. By studying the effect of different CSPs, organic modifiers, temperature, back‐pressure regulator pressures, and flow rates for the enantioseparation of napropamide, we established a rapid and green method for enantioseparation that takes less than 2 minutes: The column was CEL2, the mobile phase was CO2 with 20% 2‐propanol, and the flow rate was 2.0 mL/min. We found that CEL2 demonstrated the strongest resolution capability. Acetonitrile was favored over alcoholic solvents when the CSP was amylose and 2‐propanol was the best choice when using cellulose. When the concentration of the modifiers or the flow rate was decreased, resolutions and analysis times increased concurrently. The temperature and back‐pressure regulator pressure exhibited only minor influences on the resolution and analysis time of the napropamide enantioseparations with these chiral columns. The molecular docking analysis provided a deeper insight into the interactions between the enantiomers and the CSPs at the atomic level and partly explained the reason for the different elution orders using the different chiral columns.  相似文献   

2.
《Chirality》2017,29(6):239-246
The enantioselective potential of two polysaccharide‐based chiral stationary phases for analysis of chiral structurally diverse biologically active compounds was evaluated in supercritical fluid chromatography using a set of 52 analytes. The chiral selectors immobilized on 2.5 μm silica particles were tris‐(3,5‐dimethylphenylcarmabate) derivatives of cellulose or amylose. The influence of the polysaccharide backbone, different organic modifiers, and different mobile phase additives on retention and enantioseparation was monitored. Conditions for fast baseline enantioseparation were found for the majority of the compounds. The success rate of baseline and partial enantioseparation with cellulose‐based chiral stationary phase was 51.9% and 15.4%, respectively. Using amylose‐based chiral stationary phase we obtained 76.9% of baseline enantioseparations and 9.6% of partial enantioseparations of the tested compounds. The best results on cellulose‐based chiral stationary phase were achieved particularly with propane‐2‐ol and a mixture of isopropylamine and trifluoroacetic acid as organic modifier and additive to CO2, respectively. Methanol and basic additive isopropylamine were preferred on amylose‐based chiral stationary phase. The complementary enantioselectivity of the cellulose‐ and amylose‐based chiral stationary phases allows separation of the majority of the tested structurally different compounds. Separation systems were found to be directly applicable for analyses of biologically active compounds of interest.  相似文献   

3.
4.
Chen X  Zou H  Yang L  Wang H  Zhang Q 《Chirality》2000,12(8):621-626
Microcrystalline celluloses from two sources were used to prepare cellulose triacetate chiral stationary phases (CSPs) coated on underivatized silica gel, which shows discriminating chiral recognition for enantiomers. The chiral separation of four alpha-alkyl phenyl acetonitriles was investigated on the prepared CSPs. It was observed that the concentration of the coating solvent of phenol in dichloromethane plays an important role in the resolution of the solutes. A series of primary alcohols, including secondary and tertiary alcohols, were used as mobile phase modifiers to investigate the effect of the structures of these modifiers on the capacity factors (k') and the separation factors (alpha). Also, the effect of the concentration of alcohol on the capacity factors and separation factors was examined. The chiral recognition mechanism of alpha-alkyl phenyl acetonitriles on the prepared CSPs is discussed. Copyright 2000 Wiley-Liss, Inc.  相似文献   

5.
Work from this paper details a novel walk‐up open‐access (OA) approach to enable chiral analytical method development and preparative separation of enantiomers in early discovery chemistry using supercritical fluid chromatography (SFC). We have demonstrated the success of this OA approach using immobilized chiral stationary phases (CSPs). After screening a diverse set of racemic drug candidates, we have concluded that a simplified OA chiral SFC platform can successfully purify approximately 60% of the analysed racemates. This streamlined OA workflow enables medicinal chemists with limited expertise in chiral method development to successfully and rapidly purify enantiomers for their projects using Waters UPC2 and Prep100‐SFC instrumentation.  相似文献   

6.
Valacyclovir, a potential prodrug for the treatment of patients with herpes simplex and herpes zoster, and its analogs were resolved on two chiral stationary phases (CSPs) based on (3,3’‐diphenyl‐1,1’‐binaphthyl)‐20‐crown‐6 covalently bonded to silica gel. In order to find out an appropriate mobile phase condition, various mobile phases consisting of various organic modifiers in water containing various acidic modifiers were applied to the resolution of valacyclovir and its analogs. When 30% acetonitrile in water containing any of 0.05 M, 0.10 M, or 0.15 M perchloric acid was used as a mobile phase, valacyclovir and its analogs were resolved quite well on the two CSPs with the separation factors (α) in the range of 2.49 ~ 6.35 and resolutions (RS) in the range of 2.95 ~ 12.21. Between the two CSPs, the CSP containing residual silanol protecting n‐octyl groups on the silica surface was found to be better than the CSP containing residual silanol groups. Chirality 27:268–273, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

7.
The development of chiral HPLC methods and isolation techniques within Zeneca Agrochemicals (formerly ICI Agrochemicals) is reviewed. The use of low temperature to improve chiral separations has been successfully applied to production analysis, but although useful for some compounds it is regrettably not a universal panacea for all poor separations. The need to isolate small quantities of individual enantiomers from new compounds for research evaluation has led us to devise a more universal and cheap chiral stationary phase (CSP) for Preparative-LC. Joint academic research produced a CSP based on tartaric acid which was made commercially available and it was gratifying to find it was the only phase able to resolve a novel insecticide. However, as new CSPs emerged almost every month, our attention turned to using a universal chiral detector for analysis, rather than via separation of individual enantiomers. Diode laser-based polarimeters offered the opportunity of cheap, sensitive chiroptical detectors for HPLC and the ability to move away from chiral columns in both research and production analysis. Jointly sponsored research with a university has successfully explored the versatility of chiroptical detectors in agrochemical and food analysis. Comparison of chiral SFC with chiral HPLC and an extensive evaluation of established and research agrochemicals on a wide range of commercial CSPs have led to a revised method development strategy. Current work with high load displacement chiral chromatography will be described as a potential means of isolating pure enantiomers from racemates. © 1994 Wiley-Liss, Inc.  相似文献   

8.
Myung Ho Hyun 《Chirality》2015,27(9):576-588
Crown ether‐based chiral stationary phases (CSPs) have been known to be useful for the resolution of racemic primary amino compounds. In particular, CSPs based on (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid have been reported to be useful for the resolution of secondary amino compounds as well as primary amino compounds. In this article, the process of developing various CSPs based on (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid to improve the chiral recognition efficiency and/or the stability of the CSPs and their applications to the resolution of various primary and nonprimary amino compounds are reviewed. Chirality 27:576588, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

9.
Paola Peluso  Sergio Cossu 《Chirality》2013,25(11):709-718
With the aim to define a combined computational/chromatographic empirical approach useful for the high‐performance liquid chromatography (HPLC) method development of new chiral compounds, 36 racemic aromatic compounds with different chemical structures were used as test probes on four polysaccharide‐based chiral stationary phases (CSPs) of the Lux series, namely Lux Cellulose‐1, Lux Cellulose‐2, Lux Cellulose‐4, and Lux Amylose‐2, using classical n‐hexane/2‐propanol mixtures as mobile phase. Electrostatic potential surfaces (EPSs) determined using Density Functional Theory (DFT) calculations were used to derive size, shape, and electronic properties of each analyte. Then a comparative HPLC screening was carried out in order to evaluate the impact of substituents, shapes, and electronic properties of the analytes on the chromatographic behavior as the column changes. The four CSPs showed good complementary recognition ability. The elution sequence was determined in 30 cases out of 36. The success rate to afford baseline separations (Rs ≥ 1.5) was estimated: 29 compounds out of 36 showed baseline enantioseparation on at least one of the four selected CSPs. The combined computational‐chromatographic screening furnished useful collective structure‐chromatographic behavior relationships and a map of the chiral discrimination abilities of the considered CSPs towards the analytes. On this basis, the chromatographic behavior of new analytes on a set of polysaccharide‐based CSPs can be mapped through the qualitative correlation of chromatographic parameters (k, α, Rs) to computed molecular properties of the analytes. Chirality 25:709–718, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

10.
Dalbavancin is a new compound of the macrocyclic glycopeptide family. It was covalently linked to 5 μm silica particles using two different binding chemistries. Approximately 250 racemates including (a) heterocyclic compounds, (b) chiral acids, (c) chiral amines, (d) chiral alcohols, (e) chiral sulfoxides and sulfilimines, (f) amino acids and amino acid derivatives, and (g) other chiral compounds were tested on the two new chiral stationary phases (CSPs) using three different mobile phases. As dalbavancin is structurally related to teicoplanin, the same set of chiral compounds was screened on two commercially available teicoplanin CSPs for comparison. The dalbavancin CSPs were able to separate some enantiomers that were not separated by the teicoplanin CSPs and also showed improved separations for many racemates. However, there were other compounds only separated or better separated on teicoplanin CSPs. Therefore, the dalbavancin CSPs are complementary to the teicoplanin CSPs. Chirality, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

11.
Hui Liu  Wei Ding 《Chirality》2019,31(3):219-229
Prothioconazole is a type of broad‐spectrum triazole thione fungicide developed by the Bayer Company. Prothioconazole‐desthio is the main metabolite of prothioconazole in the environment. In our study, enantiomeric separation of prothioconazole and prothioconazole‐desthio was performed on various chiral stationary phases (CSPs) by high‐performance liquid chromatography (HPLC). It was found that polysaccharide CSPs showed better ability than brushing CSPs in enantiomeric separation. The successful chiral separation of prothioconazole could be achieved on self‐made Chiralcel OD, commercialized Chiralcel OJ‐H and Lux Cellulose‐1. Chiralpak IA, Chiralpak IB, Chiralpak IC, Chiralcel OD, Chiralpak AY‐H, Chiralpak AZ‐H, and Lux Cellulose‐1 realized the baseline separation of prothioconazole‐desthio enantiomers. Simultaneous enantiomeric separation of prothioconazole and prothioconazole‐desthio was performed on Lux Cellulose‐1 using acetonitrile (ACN) and water as mobile phase. In most cases, low temperature favored the separation of two compounds. The influence of the mobile phase ratio or type was deeply discussed. We obtained larger Rs and longer analysis time with a smaller proportion of isopropanol (IPA) or ethanol and more water content at the same temperature. The ratio of ACN and water had influences on the outflow orders of prothioconazole‐desthio enantiomers. This work provides a new approach for chiral separation of prothioconazole and prothioconazole‐desthio with a discussion of chiral separation mechanism on different CSPs.  相似文献   

12.
3,5‐Dinitrobenzoyl chloride was previously used for the preparation of (R)‐phenylglycinol‐ and (S)‐leucinol‐derived chiral stationary phases. In this study, 3,5‐bis(trifluoromethyl)benzoyl chloride, 2‐furoyl chloride, 2‐theonyl chloride, 10,11‐dihydro‐5H‐dibenzo[b,f]azepine‐5‐carbonyl chloride, diphenylcarbamoyl chloride, and 1‐adamantanecarbonyl chloride were used to prepare six new phenylglycinol‐derived chiral stationary phases (CSPs) and five new leucinol‐derived CSPs. Using these 11 CSPs, chiral separation of nine π‐acidic amino acid derivatives and five π‐basic compounds was performed, and the separation results were compared. An adamantyl‐derived CSP showed good separation. Chirality 28:276–281, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

13.
High-performance liquid chromatographic methods were developed for the separation of the enantiomers of 12 beta-lactams. Direct separations were performed on chiral stationary phases (CSPs) containing cellulose-tris-3,5-dimethylphenyl carbamate (Chiralcel OD-RH and OD-H columns), the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T column), or teicoplanin aglycone (Chirobiotic TAG column) as the chiral selector. It was clearly established that, with teicoplanin-based columns, the teicoplanin aglycone was most often responsible for the enantioseparation of the beta-lactams. The difference in enantioselective free energy between the aglycone CSP and the teicoplanin CSP was in the range between 0.02 and 0.97 kJ mol(-1) for these beta-lactam stereoisomer separations. The separations were carried out with high selectivity and resolution, and the method was therefore suitable for monitoring of the enantiomeric excess after chiral synthesis. The Chirobiotic and Chiralcel columns appear to be highly complementary to one another. The best separation of this class of beta-lactam compound could be obtained using the Chirobiotic TAG in the polar-organic mode plus the Chiralcel OD-H in the normal-phase mode. The elution sequence was also determined.  相似文献   

14.
The poly(trans-1,2-cyclohexanediyl-bis acrylamide) (P-CAP) column has so far been primarily used with normal phase and polar organic mobile phase chromatography. Its use in supercritical fluid chromatography (SFC) was investigated via the analysis of 40 commercial and 100 proprietary compounds using a 12-min gradient with methanol as a modifier. Results were then compared against those obtained from the popular derivatized polysaccharide-based chiral stationary phases (CSPs) such as Chiralpak AD-H and Chiralpak AS-H as well as Chiralcel OD-H and Chiralcel OJ-H columns. P-CAP demonstrated separation of 25% of the 140 total compounds, while each of the derivatized polysaccharide-based CSPs separated at least 46%. A study that compared the loading of 1,1'-bi-2-naphthol with P-CAP and Chiralpak AS columns indicated a similar trend in resolution vs. amount injected, though AS appeared capable of allowing a greater loading of material. The P-CAP column was found to be beneficial in the separation of a complex mixture of enantiomers and achiral impurities, where the derivatized polysaccharide-based columns did not show as desirable of a separation. A key advantage of this type of chiral stationary phase is the fact that it is available in both enantiomeric forms, allowing manipulation of elution order of enantiomers, which is especially helpful for preparative applications. P-CAP also demonstrated that it could resolve an achiral impurity from the desired compound in a different mixture, while the same impurity co-eluted on the Chiralpak AD-H column. Overall, the synthetic polymer-based P-CAP showed less chiral discrimination power compared to the derivatized polysaccharide-based CSPs under the conditions explored in this study.  相似文献   

15.
A chiral anion-exchanger stationary phase based on cinchonidine (CD) was developed. Two columns were packed with and without endcapping (EC) treatment (CD-chiral stationary phase[CD-CSP(EC)] and [CD-CSP], respectively) and studied for their ability to separate N-2,4-dinitrophenyl α-amino acids (DNP-amino acids) enantiomers over a temperature range of 10-40 °C with a hydro-organic buffer mobile phase. The more hydrophobic, endcapped stationary phase showed significantly larger retentive capacity than the non-endcapped one. The apparent thermodynamic transfer parameters of the enantiomers from the mobile to both CSPs were estimated from van't Hoff plots within the cited temperature range. Similar studies with two natural quinine-based columns (QN-CSP and QN-CSP(EC)) were previously reported. In this work, a critical comparison in the chiral recognition ability to DNP-amino acids of these cinchonidine and QN-based chiral columns was drawn. It has been found that QN-based CSPs show greater chiral recognition capability towards these derivatives than CD-CSPs. The influence of the QN methoxy group on the equilibrium constants of the enantioselective interaction between these DNP-amino acids with these two cinchona CSPs could be assessed.  相似文献   

16.
A modified macrocyclic glycopeptide‐based chiral stationary phase (CSP), prepared via Edman degradation of vancomycin, was evaluated as a chiral selector for the first time. Its applicability was compared with other macrocyclic glycopeptide‐based CSPs: TeicoShell and VancoShell. In addition, another modified macrocyclic glycopeptide‐based CSP, NicoShell, was further examined. Initial evaluation was focused on the complementary behavior with these glycopeptides. A screening procedure was used based on previous work for the enantiomeric separation of 50 chiral compounds including amino acids, pesticides, stimulants, and a variety of pharmaceuticals. Fast and efficient chiral separations resulted by using superficially porous (core‐shell) particle supports. Overall, the vancomycin Edman degradation product (EDP) resembled TeicoShell with high enantioselectivity for acidic compounds in the polar ionic mode. The simultaneous enantiomeric separation of 5 racemic profens using liquid chromatography‐mass spectrometry with EDP was performed in approximately 3 minutes. Other highlights include simultaneous liquid chromatography separations of rac‐amphetamine and rac‐methamphetamine with VancoShell, rac‐pseudoephedrine and rac‐ephedrine with NicoShell, and rac‐dichlorprop and rac‐haloxyfop with TeicoShell.  相似文献   

17.
Laskar DB  Zeng L  Xu R  Kassel DB 《Chirality》2008,20(8):885-895
Enantiomeric excess (ee) was evaluated for two internally synthesized compound libraries using a high-throughput automated, intelligent four-channel parallel supercritical fluid chromatography/mass spectrometry system equipped with a multiplexed ion source interface (SFC/MS-MUX). The two libraries contained compounds spanning a wide range of enantiomeric ratios with structurally diverse chemical scaffolds and stereogenic centers. The system analyzed each sample simultaneously against four chiral columns using up to six organic modifiers. Enhancements to our previously published parallel supercritical fluid chromatography/mass spectrometry system were implemented to address the challenges associated with automated trace enantiomer identification and quantitation. A reversal of enantiomer elution order was observed for several samples across multiple CSPs and modifiers. The relationship between elution order and % ee accuracy is presented for compounds exhibiting high, middle and low % ee values. Despite incidences in which the minor enantiomer eluted prior to the major enantiomer with less than baseline resolution, the overall % ee was in agreement with separations in which full baseline resolution was achieved. The methods presented here demonstrate the value and utility of high-throughput ee determinations to support drug discovery and development programs.  相似文献   

18.
A convenient method using a fluorogenic agent, 4‐chloro‐7‐nitro‐1,2,3‐benzoxadiazole (NBD‐Cl), was developed for enantiomer separation of chiral aliphatic amines including amino alcohols by normal high‐performance liquid chromatography. The enantiomer separation of chiral aliphatic amines as NBD derivatives was performed on six covalently bonded and four coated‐type polysaccharide‐derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence detection (FLD). Among the covalently bonded CSPs, Chiralpak IE showed the best enantiomer separation for most analytes. The other CSPs also showed good enantioselectivity except for Chiralpak IB. On the other hand, Chiralpak AD‐H and Amylose‐1 generally exhibited better enantiomer separation of NBD derivatized chiral amines among the coated CSPs. The developed analytical technique was also applied to determine the optical purity of commercially available (R)‐ and (S)‐leucinol; the impurity was found to be 0.06%. The developed method was validated and proved to be an accurate, precise, sensitive, and selective method suitable for separation of chiral aliphatic amines as NBD derivatives under simultaneous UV and FLD.  相似文献   

19.
High performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to examine the enantiomeric separation of a series of 17 racemic tetrahydrobenzimidazole analytes. These compounds were prepared as part of a synthetic program directed towards a select group of pyrrole‐imidazole alkaloids. This group of natural products has a unique framework of pyrrole‐ and guanidine‐containing fused rings which can be constructed through the intermediacy of a tetrahydrobenzimidazole scaffold. Several bonded cyclodextrin‐ (both native and derivatized) and derivatized cyclofructan‐based chiral stationary phases were evaluated for their ability to separate these racemates via HPLC. Similarly, several cyclodextrin derivatives and derivatized cyclofructan were evaluated for their ability to separate this set of chiral compounds via CE. Enantiomeric selectivity was observed for the entire set of racemic compounds using HPLC with resolution values up to 3.0. Among the 12 different CSPs, enantiomeric recognition was most frequently observed with the Cyclobond RN and LARIHC CF6‐P, while the Cyclobond DMP yielded the greatest number of baseline separations. Fifteen of the analytes showed enantiomeric recognition in CE with resolution values as high as 5.0 and hydroxypropyl‐γ‐cyclodextrin was the most effective chiral additive. Chirality 25:133–140, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

20.
Recently, we reported the development of new chiral stationary phases (CSPs) for liquid chromatography (LC) based on chiral derivatives of xanthones (CDXs). Based on the most promising CDX selectors, 12 new CSPs were successfully prepared starting from suitable functionalized small molecules including xanthone and benzophenone derivatives. The chiral selectors comprising one, two, three, or four chiral moieties were covalently bonded to a chromatographic support and further packed into LC stainless-steel columns (150 × 2.1 mm I.D.). The enantioselective performance of the new CSPs was evaluated by LC using different classes of chiral compounds. Specificity for enantioseparation of some CDXs was observed in the evaluation of the new CSPs. Besides, assessment of chiral recognition mechanisms was performed by computational studies using molecular docking approach, which are in accordance with the chromatographic parameters. X-Ray analysis was used to establish a chiral selector 3D structure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号