The implantable cardioverter-defibrillator (ICD) has become an integral part of treatment for a variety of patients with symptomatic, or at risk for, ventricular tachyarrhythmias. The ICD's effectiveness is attributed to its ability to promptly detect and terminate ventricular tachycardia (VT) and fibrillation (VF). The clinical trials that established the positive role of ICD therapy were based on patients who underwent some form of defibrillation testing at the time of implantation. Therefore, since its advent, intraoperative defibrillation testing of the ICD to assure reliable detection and termination of VT/VF has been a standard practice. But because of advances in defibrillator and lead technology, which now facilitates successful device implantation (i.e., low defibrillation energy requirement to allow for an adequate programmed safety margin) in the majority of patients, the necessity of defibrillation testing has been called into attention. Despite substantial progress, it is not altogether clear whether a wholesale abandonment of intraoperative ICD testing is appropriate at this point. We review pertinent data regarding pros and cons of ICD testing and offer a suggestion as to when, how, and who should test ICDs.  相似文献   

2.
Automatic implantable cardioverter defibrillator is now a well established therapy to prevent sudden cardiac death. In secondary prevention (patients with a previous cardiac arrest) defibrillator can be considered as a class I indication, if there is no transient or reversible cause. The level of proof is A. in primary prevention the defibrillator is indicated in coronary artery disease patients with or without symptoms of mild to moderate heart failure (NYHA II or III), an ejection fraction lower than 30 %, measured at least one month after a myocardial infarction and 3 months after a revascularisation, surgery or angioplasty (level of proof B). It is also indicated in symptomatic spontaneous sustained ventricular tachycardias with underlying heart disease (level of proof B), in patients with spontaneous sustained ventricular tachycardia, poorly tolerated, without underlying heart disease for which pharmacological treatment or ablation can not be performed or failed (level of proof B). Finally it is also indicated in patients with syncope of unknown cause with sustained ventricular tachycardia or inducible ventricular fibrillation, with an underlying heart disease (level of proof B). The guidelines proposed by the different societies have also proposed class IIa recommendations which are the following: coronary artery disease patients with left ventricular dysfunction (ejection fraction between 31 or 35 %) measured at least one month after a myocardial infarction and 3 months after a revascularisation with an inducible ventricular arrhythmia. It can be also indicated in idiopathic dilated cardiomyopathies with an ejection fraction lower than 30% and NYHA class II or III. It can be also indicated in familial or inherited conditions with a high risk of sudden cardiac death by ventricular fibrillation without any other efficient known treatment and finally in heart failure patients remaining symptomatic, in class III or IV NYHA, with an optimal medical therapy, an ejection fraction lower than 35 % and a QRS complex duration higher than 120 ms: in this case it is an indication of cardiac resynchronization therapy device associated to the defibrillator. All these class IIa indications have a level of proof B.  相似文献   

3.
Objective To review the evidence base from randomised controlled trials of combined cardiac resynchronisation therapy and implantable cardioverter defibrillator therapy in left ventricular impairment and symptomatic heart failure.Design Bayesian network meta-analysis.Data sources Medline, Embase, and Cochrane databases up to June 2006.Review methods Two reviewers independently assessed trial eligibility and quality. Included trials compared cardiac resynchronisation therapy, implantable cardioverter defibrillator therapy, combined resynchronisation and implantable defibrillator therapy, and medical therapy alone, in patients with impaired left ventricular systolic function. Bayesian random effects network models were used to examine overall number of deaths.Results 12 studies including 1636 events in 8307 patients were identified. Combined cardiac resynchronisation and implantable cardioverter defibrillator therapy reduced the number of deaths by one third compared with medical therapy alone (odds ratio 0.57, 95% credible interval 0.40 to 0.80) but did not further improve survival when compared with implantable defibrillator therapy (0.82, 0.57 to 1.18) or resynchronisation (0.85, 0.60 to 1.22) therapy alone.Conclusion Evidence from randomised controlled trials is insufficient to show the superiority of combined cardiac resynchronisation and implantable cardioverter defibrillator therapy over cardiac resynchronisation therapy alone in patients with left ventricular impairment.  相似文献   

4.
A 64-year-old male, with a history of a lateral myocardial infarction, presented with haemodynamically well-tolerated incessant therapy-resistant slow monomorphic ventricular tachycardia (mVT), despite implantable cardioverter defibrillator and antiarrhythmic drugs.  相似文献   

5.
Arrhythmogenic right ventricular dysplasia/cardiomyopathy is a disorder characterized by frequent ventricular tachycardia originating from the right ventricle and fibro-fatty replacement of right ventricular myocardium. Though the disorder was originally described during surgical ablation of refractory ventricular tachycardia, catheter ablation of tachycardia is one of the options for patients not responding to anti arrhythmic agents. Direct current fulguration was used in the initial phase followed by radiofrequency catheter ablation. In the present day scenario, all patients with risk for sudden cardiac death should receive an implantable cardioverter defibrillator. Radiofrequency catheter ablation remarkably reduces the frequency of defibrillator therapies. Direct current fulguration can still be considered in cases when radiofrequency ablation fails, though it requires higher expertise, general anesthesia and carries a higher morbidity. Newer mapping techniques have helped in identification of the site of ablation. In general, the success rate of ablation in arrhythmogenic right ventricular dysplasia is less than in other forms of right ventricular tachycardias like right ventricular outflow tract tachycardia.  相似文献   

6.
One of the most important subsystems of implantable cardioverter defibrillator (ICD) is the sensing stage, since it determines the sensitivity and specificity of the device to detect the heart rate and the underlying arrhythmia. This paper aims to investigate a new detection algorithm for ICD, which operates fully automatically. The algorithm ARGUS was implemented as a computer model and tested with intracardiac electrograms recorded (band-pass: 0.05 to 500 Hz; sampling rate: 1-4 kHz) under different rhythm condition like sinus rhythm (n = 18), atrial tachycardia (n = 16), and ventricular tachycardia as well as fibrillation (n = 139) during electrophysiological tests or ICD implantation. The results of the tests were visually inspected on a beat-to-beat basis. In total 31,934 events were classified by the algorithm (18,758 as long intervals (LI) with cycle length > 300 ms; 13,176 as short intervals (SI)). 195 out of the 13,176 SI and 572 out of 18,758 LI were incorrectly classified (SI: 1.48%; LI: 3.05%). In conclusion the new algorithm yield high sensitivity (99.9%) and specificity (97.0%) as known from conventional ICD algorithms but need no manual adjustments.  相似文献   

7.
A 55 year old male presented with recurrent implantable cardioverter defibrillator (ICD) shocks due to polymorphic ventricular tachycardia (PMVT). He had undergone prior catheter ablation for VT three years ago. During the prior attempt he underwent voltage guided substrate ablation. With programmed ventricular extrastimulation (PVES), PMVT was repeatedly induced requiring DC shock. Intravenous procainamide was administered and PVES was repeated which induced sustained monomorphic ventricular tachycardia (MMVT). This VT had pseudo delta waves with maximum deflection index of 0.68, suggestive of epicardial origin. Activation mapping was performed epicardially. Presystolic potentials were recorded in mid anterolateral wall of left ventricular epicardial region. Radiofrequency (RF) ablation at this site terminated the VT. Post ablation there was no inducible tachycardia and patient is free of arrhythmias during 2 years of follow-up.  相似文献   

8.
A 63-year-old lady with a high-grade atrioventricular (AV) block and a structurally normal heart underwent permanent pacemaker implantation (dual chamber, Medtronic Ltd) 8 years back. On follow up, she had a recurrence of syncope after 3 years. The device interrogation at that time had revealed ventricular tachycardia (VT) for which she underwent implantable cardioverter defibrillator (ICD, Medtronic Ltd, Egida DR, DF1) upgradation at another center (electrograms not available). Now, she presents with episodes of presyncope after another 5 years. The Echocardiography was unremarkable. The ICD was interrogated & there was a stored ventricular fibrillation (VF) episode. But the electrograms suggested noise over a true VF electrogram noted in both near and far-field. In all probability, the VF was not a true one which might have arisen from some lead noise or from an electromagnetic interference (EMI). Fluoroscopy revealed an evident lead fracture near the superior vena cava (SVC) coil. The stored electrogram (EGM) characteristics also suggested possible lead noise rather than a true VF. She was advised for lead revision. Interestingly, all pacing parameters were normal along with normal impedance despite the evident lead fracture. This happened due to the ICD lead arrangements as there are separate electrodes for the SVC/RV coil and pacing. While the SVC coil was damaged, the pacing electrodes remained unaffected. Since the patient has no episode of true VT/NSVT and the echocardiography was normal, she was managed temporarily by changing the pacemaker to asynchronous (DOO) mode.  相似文献   

9.
A 77-year-old white diabetic woman was brought to our emergency department (ED) after becoming lightheaded and hypotensive at home. Her routine tests including a chest radiograph were normal. Her electrocardiogram (ECG) showed significant ST segment elevation in leads V1 to V4. Serial cardiac enzymes and troponin were within normal limits. Her ECG met the criteria for type 1 Brugada syndrome. Brugada syndrome, which is more common in young Asian males, is an arrhythmogenic disease caused in part by mutations in the cardiac sodium channel gene SCN5A. To diagnose the Brugada syndrome, 1 ECG criterion and 1 clinical criterion should exist. Brugada syndrome can be associated with ventricular tachycardia or fibrillation; the only treatment proven to prevent sudden death is placement of an implantable cardioverter defibrillator, which is recommended in symptomatic patients or in those with ventricular tachycardia induced during electrophysiologic studies and a type 1 ECG pattern of Brugada syndrome. It is important to recognize the Brugada ECG pattern and to differentiate it from other etiologies of ST segment elevation on ECG.  相似文献   

10.
We report a patient with an implantable cardioverter defibrillator (ICD) for arrhythmogenic right ventricular dysplasia (ARVD) who received inappropriate shocks for atrioventricular node reentry tachycardia (AVRNT). Patient had multiple shocks for tachycardia with EGM characteristics of very short VA interval and CL of 300 msec. An electrophysiologic (EP) study reproducibly induced typical AVNRT with similar features. The slow AV nodal pathway ablation resolved the ICD shocks. Despite increasingly sophisticated discrimination algorithms available in modern ICDs, the ability to differentiate SVT from VT can be challenging. Our patient received inappropriate shocks for AVNRT. When device interrogation alone is not conclusive, an EP study may be necessary to determine the appropriate therapeutic course.  相似文献   

11.
In the last two decades, the focus of implantable cardioverter defibrillator {ICD} trials has mainly been on prophylactic implantation of ICDs in high-risk populations for the prevention of sudden cardiac death. In particular, prophylactic ICDs in high-risk post-MI patients with a depressed left ventricular ejection fraction has resulted in significantly improved survival. These benefits are in addition to those of optimal pharmacological therapy and ICD therapy should be considered the standard of care in these patients.  相似文献   

12.
Sudden cardiac death in the absence of apparent structural heart disease is an uncommon phenomenon. The majority of these patients do not have ‘normal’ hearts and specific diagnostic tools are required to identify structural or functional abnormalities. We describe the history of a 50-yearold man who survived ventricular fibrillation. Clinical investigation, including a coronary angiography and electrophysiological study, appeared to be normal. An implantable cardioverter defibrillator was inserted. Follow-up Holter monitoring was performed after a recurrent episode of ventricular tachycardia. It demonstrated transient ST-segment elevation. An acetylcholine provocation test was subsequently carried out. Reversible coronary spasm of the left descending coronary artery was found, during which a diagonal branch was occluded. It may be concluded that coronary spasm provocation is of value in the routine diagnostic work-up of patients surviving sudden cardiac death without apparent heart disease. (Neth Heart J 2008;16:239-41.)  相似文献   

13.

Introduction

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetically transmitted disease prone to ventricular arrhythmias. We therefore investigated the clinical, echocardiographical and electrophysiological predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in patients with ARVC.

Methods

A retrospective analysis was performed in 26 patients (median age of 40 years at diagnosis, 21 males and 5 females) with ARVC who underwent ICD implantation.

Results

Over a median (range) follow-up period of 10 (2.7, 37) years, appropriate ICD therapy for ventricular arrhythmias was documented in 12 (46%) out of 26 patients. In all patients with appropriate ICD therapy the ICD was originally inserted for secondary prevention. Median time from ICD implantation to ICD therapy was 9 months (range 3.6, 54 months). History of heart failure was a significant predictor of appropriate ICD therapy (p = 0.033). Left ventricular disease involvement (p = 0.059) and age at implantation (p = 0.063) were borderline significant predictors. Patients with syncope at time of diagnosis were significantly less likely to receive ICD therapy (p = 0.02). Invasive electrophysiological testing was not significantly associated with appropriate ICD therapy.

Conclusion

In our cohort of patients with ARVC, history of heart failure was a significant predictor of appropriate ICD therapy, whereas left ventricular involvement and age at time of ICD implantation were of borderline significance. These predictors should be tested in larger prospective cohorts to optimize ICD therapy in this rare cardiomyopathy.  相似文献   

14.
Ventricular oversensing in patients with defibrillators is an infrequent but deleterious condition. We report a patient with a cardiac resynchronization–defibrillation device that presented with hyperkalemia and syncope. Device interrogation revealed ventricular double-counting within the QRS of a slow ventricular tachycardia, resulting detection of the slow ventricular tachycardia in the ventricular fibrillation zone, and delivery of an effective therapy, below device programmed detection rate. This case of defibrillator inappropriate detection emphasizes the relevance of device electrogram interrogation in order to minimize inappropriate therapies.  相似文献   

15.
One day after childbirth, a 29-year-old woman had several episodes of polymorphic ventricular tachycardia and ventricular fibrillation. She was rescued by an internal cardioverter defibrillator (ICD) which she had received 14 years ago, after out-ofhospital cardiac arrest, without recurrences until now. The electrocardiogram showed a normal QT interval, and ventricular premature beats, which seemed to arise from the same site. This case report illustrates that, even after years with freedom of ICD therapy, depleted devices still have to be replaced. (Neth Heart J 2008;16:242-5).  相似文献   

16.
The implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with an increased risk of sudden cardiac death (SCD). The wearable cardioverter defibrillator (WCD) is an alternative to the ICD in patients with a transient ICD indication or those in whom an ICD temporarily cannot be implanted. We describe here the technical details of the WCD and report three patients who were treated with a WCD in an outpatient setting. The WCD allowed the cardiac condition of two patients to improve to such an extent that permanent ICD implantation was deemed unnecessary. This new form of therapy may result in significant cost reduction, avoidance of unnecessary ICD implantation, and increased patient satisfaction.  相似文献   

17.
A 58 year-old-patient developed an episode of polymorphic atrial tachycardia which looked like "atrial torsades de pointes" after a 5J shock from implantable cardioverter defibrillator.  相似文献   

18.
The automatic implantable cardioverter defibrillator (AICD) recognizes malignant ventricular tachycardias in high-risk patients and reduces the risk of sudden cardiac death by releasing intense electrical discharges, so-called shocks. This sudden and very painful event results in a state of anxiety. For example, the incidence of panic disorders and agoraphobia has been found to be about 20%. This article gives an overview of the psychiatric disorders emerging after implantations, and it discusses to what extent these disorders meet the criteria of a post-traumatic disorder.  相似文献   

19.
Implantable defibrillators are lifesavers and have improved mortality rates in patients at risk of sudden death, both in primary and secondary prevention. However, they are unable to modify the myocardial substrate, which remains susceptible to life-threatening ventricular arrhythmias. Electrical storm is a clinical entity characterized the recurrence of hemodynamically unstable ventricular tachycardia and/or ventricular fibrillation, twice or more in 24 hours, requiring electrical cardioversion or defibrillation. With the arrival of the implantable cardioverter-defibrillator, this definition was broadened, and electrical storm is now defined as the occurrence of three or more distinct episodes of ventricular tachycardia or ventricular fibrillation in 24 hours, requiring the intervention of the defibrillator (anti-tachycardia pacing or shock). Clinical presentation can be very dramatic, with multiple defibrillator shocks and hemodynamic instability. Managing its acute presentation is a challenge, and mortality is high both in the acute phase and in the long term. In large clinical trials involving patients implanted with a defibrillator both for primary and secondary prevention, electrical storm appears to be a harbinger of cardiac death, with notably high mortality soon after the event. In most cases, the storm can be interrupted by medical therapy, though transcatheter radiofrequency ablation of ventricular arrhythmias may be an effective treatment for refractory cases.This narrative literature review outlines the main clinical characteristics of electrical storm and emphasises critical points in approaching and managing this peculiar clinical entity. Finally focus is given to studies that consider transcatheter ablation therapy in cases refractory to medical treatment.  相似文献   

20.
To prevent sudden cardiac death of patients who are at risk from long standing tachyarrhythmia the implantable cardioverter defibrillator (ICD) is the first choice therapy. ICDs use a range of electrostimuli up to defibrillation, which is a non synchronous high energy shock, whereas cardioversion is synchronous with the ECG. In order to know when and how to react, a detection algorithm, which analyses an intracardial electrocardiogram (ECG) and classifies the heart rhythm, is implemented in every ICD. All detection algorithms use the heart rate to classify the different heart rhythms roughly. If a tachycardia is detected, it is important to discriminate between a ventricular tachycardia, which is life threatening and a supraventricular tachycardia, which is much less threatening. To be able to make this distinction the detection algorithms analyse the behaviour of the heart cycle intervals, the ECG-morphology or in addition to the ventricular ECG, an atrial ECG. In this paper morphological algorithms will be evaluated and newly developed algorithms will be presented. Recent algorithms use the mathematical wavelet theory. The evaluation shows that these get better results than all but one of the simpler classical morphological algorithms. A new wavelet based algorithm, developed by the authors, exhibits the best detection results.  相似文献   