首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Outgrowth of neurites in culture is used for assessing neurotrophic activity. Neurite measurements have been performed very slowly using manual methods or more efficiently with interactive image analysis systems. In contrast, medium-throughput and noninteractive image analysis of neurite screens has not been well described. The authors report the performance of an automated image acquisition and analysis system (IN Cell Analyzer 1000) in the neurite assay. Neuro-2a (N2a) cells were plated in 96-well plates and were exposed to 6 conditions of retinoic acid. Immunofluorescence labeling of the cytoskeleton was used to detect neurites and cell bodies. Acquisition of the images was automatic. The image set was then analyzed by both manual tracing and automated algorithms. On 5 relevant parameters (number of neurites, neurite length, total cell area, number of cells, neurite length per cell), the authors did not observe a difference between the automated analysis and the manual analysis done by tracing. These data suggest that the automated system addresses the same biology as human scorers and with the same measurement precision for treatment effects. However, throughput of the automated system is orders of magnitude higher than with manual methods.  相似文献   

2.
OBJECTIVE: To develop an image analysis system to automatically identify colony-forming units (CFUs) in in vitro cell cultures of connective tissue progenitors. This system was designed to quantitatively assess colony morphology and number of colonies in 4-cm(2) culture wells. STUDY DESIGN: Large field-of-view high-resolution fluorescence images of 4',6-diamidino-2-phenylindole (DAPI)- and alkaline phosphatase (AP)-stained bone marrow cell cultures were obtained using an epi-fluorescence microscope and automated scanning stage. Cell nuclei were identified in the DAPI-stained images after removal of fluorescent debris from the image. An Euclidean distance map (EDM) of the segmented cell nuclei was used to cluster cell nuclei into colonies. The automated system was evaluated using 40 tissue culture wells of bone marrow aspirate samples. The results of the automated analysis were compared to the manual tracings of colonies by 3 reviewers. RESULTS: The automated method agreed with all 3 reviewers on average 87.5% of the time. Additionally, reviewers identified other colonies not outlined by the reviewers on average 2.7 times more than the automated method. CONCLUSION: The automated method is a less biased method for identifying CFUs than individual reviewers, it provides more quantitative information about colony morphology than can be obtained manually and it is less time consuming.  相似文献   

3.
Documenting local space use of birds that move rapidly, but are too small to carry GPS tags, such as swallows and swifts, can be challenging. For these species, tracking methods such as manual radio‐telemetry and visual observation are either inadequate or labor‐ and time‐intensive. Another option is use of an automated telemetry system, but equipment for such systems can be costly when many receivers are used. Our objective, therefore, was to determine if an automated radio‐telemetry system, consisting of just two receivers, could provide an alternative to manual tracking for gathering data on local space use of six individuals of three species of aerial insectivores, including one Cliff Swallow (Petrochelidon pyrrhonota), one Eastern Phoebe (Sayornis phoebe), and four Barn Swallows (Hirundo rustica). We established automated radio‐telemetry systems at three sites near the city of Peterborough in eastern Ontario, Canada, from May to August 2015. We evaluated the location error of our two‐receiver system using data from moving and stationary test transmitters at known locations, and used telemetry data from the aerial insectivores as a test of the system's ability to track rapidly moving birds under field conditions. Median location error was ~250 m for automated telemetry test locations after filtering. More than 90% of estimated locations had large location errors and were removed from analysis, including all locations > 1 km from receiver stations. Our automated telemetry receivers recorded 17,634 detections of the six radio‐tagged birds. However, filtering removed an average of 89% of bird location estimates, leaving only the Cliff Swallow with enough locations for analysis of space use. Our results demonstrate that a minimal automated radio‐telemetry system can be used to assess local space use by small, highly mobile birds, but the resolution of the data collected using only two receiver stations was coarse and had a limited range. To improve both location accuracy and increase the percentage of usable location estimates collected, we suggest that, in future studies, investigators use receivers that simultaneously record signals detected by all antennas, and use of a minimum of three receiver stations with more antennas at each station.  相似文献   

4.
A slit-scan technique was developed as a basis for an automated prescreening system for gynecologic cytology. A flow system based on this technique was fabricated and tested and results indicated that false alarms (misclassification of objects or events from normal specimens as abnormal) are the greatest remaining obstacle to development of an automated prescreening instrument. A dual view correlation system was fabricated to provide exact image-contour correlation in flow and permit precise determination of causes and occurrence rates of false alarms. This paper presents data from correlation analyses of 23 normal cytologic specimens. Major causes of false alarms and their implications to automated prescreening are discussed. A technique that would eliminate the majority of false alarms in flow is presented.  相似文献   

5.

Background  

MannDB was created to meet a need for rapid, comprehensive automated protein sequence analyses to support selection of proteins suitable as targets for driving the development of reagents for pathogen or protein toxin detection. Because a large number of open-source tools were needed, it was necessary to produce a software system to scale the computations for whole-proteome analysis. Thus, we built a fully automated system for executing software tools and for storage, integration, and display of automated protein sequence analysis and annotation data.  相似文献   

6.
Expression of the green fluorescent protein (gfp) gene, under regulatory control of either the constitutive 35S promoter or the developmentally-regulated lectin promoter was monitored and quantified using a newly-developed automated tracking system. The automated system consisted of a computer-controlled two-dimensional robotics table and a programmable image acquisition system, which was used to semi-continuously monitor gfp gene expression during development of transgenic soybean [Glycine max (L.) Merrill] somatic embryos. Quantitative analysis of GFP expression showed that, during somatic embryo proliferation and early development, expression of lectin-GFP was not detected. During late embryo development, expression of lectin-GFP gradually increased until the levels were similar to those of 35S-GFP. The use of an automated image collection system and image analysis facilitated the frequent monitoring and quantification of gfp gene expression on a large number of samples over an extended period of time.Electronic Supplementary Material Supplementary material is available for this article at  相似文献   

7.
Efforts to understand cognition will be greatly facilitated by computerized systems that enable the automated analysis of animal behavior. A number of controversies in the invertebrate learning field have resulted from difficulties inherent in manual experiments. Driven by the necessity to overcome these problems during investigation of neural function in planarian flatworms and frog larvae, we designed and developed a prototype for an inexpensive, flexible system that enables automated control and analysis of behavior and learning. Applicable to a variety of small animals such as flatworms and zebrafish, this system allows automated analysis of innate behavior, as well as of learning and memory in a plethora of conditioning paradigms. We present here the schematics of a basic prototype, which overcomes experimenter effects and operator tedium, enabling a large number of animals to be analyzed with transparent on-line access to primary data. A scaled-up version of this technology represents an efficient methodology to screen pharmacological and genetic libraries for novel neuroactive reagents of basic and biomedical relevance.  相似文献   

8.
Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they could not be applied to MSCs. Here, we report on activation and single channel analysis of a bacterial mechanosensitive ion channel using an automated patch clamp system. With the automated system, we could patch not only giant unilamellar liposomes but also giant Escherichia coli (E. coli) spheroplasts. The tension sensitivity and channel kinetics data obtained in the automated system were in good agreement with that obtained from the conventional patch clamp. The findings will pave the way to high throughput fundamental and drug screening studies on mechanosensitive ion channels.  相似文献   

9.
Evaluation of an Automated Colony Counter   总被引:2,自引:2,他引:0       下载免费PDF全文
An automated colony counter was found to readily detect surface and subsurface bacterial colonies of 0.3-mm size or greater with a high degree of precision. On a logarithmic scale, counting efficiency consistently ranged from 89 to 95% of corresponding manual count determinations for plates containing up to 1,000 colonies. In routine application, however, automated plate counts up to approximately 400 colonies were selected as a more practical range for operation. The automated counter was easily interfaced with an automated data acquisition system.  相似文献   

10.
We report the development of a novel, multi-specimen imaging system for high-throughput transmission electron microscopy. Our cartridge-based loading system, called the "Gatling", permits the sequential examination of as many as 100 specimens in the microscope for room temperature electron microscopy using mechanisms for rapid and automated specimen exchange. The software for the operation of the Gatling and automated data acquisition has been implemented in an updated version of our in-house program AutoEM. In the current implementation of the system, the time required to deliver 95 specimens into the microscope and collect overview images from each is about 13 h. Regions of interest are identified from a low magnification atlas generation from each specimen and an unlimited number of higher magnifications images can be subsequently acquired from these regions using fully automated data acquisition procedures that can be controlled from a remote interface. We anticipate that the availability of the Gatling will greatly accelerate the speed of data acquisition for a variety of applications in biology, materials science, and nanotechnology that require rapid screening and image analysis of multiple specimens.  相似文献   

11.
We have developed a novel automated system to analyze protein complexes by integrating a surface plasmon resonance (SPR) biosensor with highly sensitive nanoflow liquid chromatography-tandem mass spectrometry (LC-MS/MS). A His-tagged protein, which is also tagged with FLAG and biotinylated sequences, was expressed in mammalian cells. After purification by using the His tag from the cell lysate, the sample protein mixture was applied to an SPR biosensor and the protein complex was captured on the sensor chip. The automated SPR-LC-MS/MS was then performed: (1) two-step on-chip purification of the protein complex by using the FLAG and the biotinylated tags, (2) on-chip protease digestion of the complex, and (3) online nanoflow LC-MS/MS analysis of the resulting peptide fragments for protein identification. All of these processes could be monitored in real-time by the SPR biosensor. We validated the performance of the system using either FK506-binding protein 52 kDa (FKBP52) or ribosomal protein S19 (rpS19) as bait. Thus, the fully automated SPR-LC-MS/MS system appeared to be a powerful tool for functional proteomics studies, particularly for snapshot analysis of functional cellular complexes and machines.  相似文献   

12.
The efficiency of the automated metaphase finding system METAFER2 is assessed in a routine mutagenicity assay using an aneuploid rat liver cell line treated with various promutagens. Data sets generated by automated and manual selection of metaphases are compared. It is demonstrated that METAFER2 routinely allows an efficient automatic identification of metaphases not only in lymphocyte preparations, but also in preparation from mammalian cell lines with varying chromosome numbers. Although larger slide areas are required for automated compared to manual metaphase scanning, the automatic system is faster by a factor of about 5. The interactive visual elimination of metaphases of insufficient quality is an easy and fast procedure.METAFER2 allows an unbiased selection of metaphases irrespective of their appearance as homogeneously stained first or harlequin-staines second division cells. Random selection of metaphases is neither influenced by various structural chromosome changes nor by increased frequencies of sister-chromatid exchanges.  相似文献   

13.
High Throughput Screening of Gene Expression Signatures   总被引:1,自引:0,他引:1  
Kuklin A  Shams S  Shah S 《Genetica》2000,108(1):41-46
This paper focuses on microarray image analysis and discusses a completely automated approach to image processing, which eliminates human intervention. A system for automated image processing is described, which is capable of processing image files in a batch-mode thus allowing high-throughput of microarray image analysis. Grid-placement and spot finding are achieved without operator's help. The software eliminates noise signals from the data analysis process and minimizes operator's involvement in the procedure.  相似文献   

14.
Measurement of neurite outgrowth is a common assay of neurotrophic activity. However, currently available techniques for measuring neurite outgrowth are either time or resource intensive. The authors established a system in which chronic treatment of a subcloned SH-SY5Y cell line with aphidicolin and various concentrations of nerve growth factor (NGF) induced discernable alterations in proliferation and differentiation. Cells were fixed, labeled with a nonfluorescent dye, and evaluated both manually and with an automated analysis system. NGF increased multiple parameters of differentiation, including neurite length, the proportion of cells extending neurites, and branching, as well as promoting cellular survival/proliferation. Interestingly, although NGF treatment increased the total number of branches, it actually decreased the proportion of branches per neurite length. The authors observed no differences in results obtained using the manual and automated systems, but the automated system was orders of magnitude faster. To demonstrate the flexibility of the system, the authors also show that they could measure changes in differentiation induced by a small-molecule Rho kinase inhibitor, as well as by retinoic acid cotreatment with brain-derived neurotrophic factor. In addition to this flexibility, this system does not require specialized equipment or fluorescent antibodies for analysis and therefore provides a less resource-intensive alternative to fluorescence-based systems.  相似文献   

15.
A modular microscope-based screening platform, with applications in large-scale analysis of protein function in intact cells is described. It includes automated sample preparation, image acquisition, data management and analysis, and the genome-wide automated retrieval of bioinformatic information. The modular nature of the system ensures that it is rapidly adaptable to new biological questions or sets of proteins. Two automated functional assays addressing protein secretion and the integrity of the Golgi complex were developed and tested. This shows the potential of the system in large-scale, cell-based functional proteomic projects.  相似文献   

16.
Efforts to understand cognition will be greatly facilitated by computerized systems that enable the automated analysis of animal behavior. A number of controversies in the invertebrate learning field have resulted from difficulties inherent in manual experiments. Driven by the necessity to overcome these problems during investigation of neural function in planarian flatworms and frog larvae, we designed and developed a prototype for an inexpensive, flexible system that enables automated control and analysis of behavior and learning. Applicable to a variety of small animals such as flatworms and zebrafish, this system allows automated analysis of innate behavior, as well as of learning and memory in a plethora of conditioning paradigms. We present here the schematics of a basic prototype, which overcomes experimenter effects and operator tedium, enabling a large number of animals to be analyzed with transparent on‐line access to primary data. A scaled‐up version of this technology represents an efficient methodology to screen pharmacological and genetic libraries for novel neuroactive reagents of basic and biomedical relevance. © 2006 Wiley Periodicals, Inc. J Neurobiol, 2006  相似文献   

17.
A rugged, reproducible, multi-dimensional LC-MS system was developed to identify and characterize proteins involved in protein-protein interactions and/or protein complexes. Our objective was to optimize chromatographic parameters for complex protein mixture analyses using automated peptide sequence recognition as an analytical end-point. The chromatographic system uses orthogonal separation mechanisms by employing strong cation exchange (SCX) in the first dimension and reversed phase (RP) in the second dimension. The system is fully automated and sufficiently robust to handle direct injections of protein digests. This system incorporates a streamlined post analysis results comparison, called DBParser, which permitted comprehensive evaluation of sample loading and chromatographic conditions to optimize the performance and reproducibility. Peptides obtained from trypsin digestion of a yeast soluble extract provided an open-ended model system containing a wide variety and dynamic range of components. Conditions are described that resulted in an average (n = 4) of 1489 unique peptide identifications, corresponding to 459 non-redundant protein sequence database records (SDRs) in the 20 microg soluble fraction digest.  相似文献   

18.
Organophosphate pesticides present serious risks to human and environmental health. A rapid reliable, economical and portable analytical system will be of great benefit in the detection and prevention of contamination. A biosensor array based on six acetylcholinesterase enzymes for use in a novel automated instrument incorporating a neural network program is described. Electrochemical analysis was carried out using chronoamperometry and the measurement was taken 10s after applying a potential of 0 V vs. Ag/AgCl. The total analysis time for the complete assay was less than 6 min. The array was used to produce calibration data with six organophosphate pesticides (OPs) in the concentration range of 10(-5) M to 10(-9) M to train a neural network. The output of the neural network was subsequently evaluated using different sample matrices. There were no detrimental matrix effects observed from water, phosphate buffer, food or vegetable extracts. Furthermore, the sensor system was not detrimentally affected by the contents of water samples taken from each stage of the water treatment process. The biosensor system successfully identified and quantified all samples where an OP was present in water, food and vegetable extracts containing different OPs. There were no false positives or false negatives observed during the evaluation of the analytical system. The biosensor arrays and automated instrument were evaluated in situ in field experiments where the instrument was successfully applied to the analysis of a range of environmental samples. It is envisaged that the analytical system could provide a rapid detection system for the early warning of contamination in water and food.  相似文献   

19.
Nokihara K  Gerhardt J 《Chirality》2001,13(8):431-434
In the use of combinatorial chemistry as a novel strategy for drug discovery, the chirality assessment of building blocks used for library construction is particularly important in the evaluation of biological actions of generated libraries. The procedure for chiral analysis of lead compounds in screening may be of a high priority, particularly in the case of the protection of intellectual rights. Previously, an automated amino acid analysis system using enantiomer labeling was developed. The system incorporates a reactor, which allows automated esterification and acylation of amino acids, and is connected to an on-line gas chromatographic system. A capillary column coated with a chiral phase is employed for the separation of the enantiomers. This particular system is improved with a newly constructed "high-throughput auto-derivatizer" in combination with a new GC-system. The resulting data can be processed by newly constructed software. The analyses of amino acid derivatives or hydrolysates of proteins and peptides are carried out routinely within ca. 45 min, including derivatization. Using this system several non-natural amino acids were tested with respect to the stereoisomeric configuration. In addition, acid hydrolysates of food proteins and tissues obtained by autopsy were analyzed as an application to proteome research.  相似文献   

20.
A fully automated method for assaying the collagen crosslinking amino acids, pyridinoline and deoxypyridinoline, in human urine samples or tissue hydrolysates is described. Samples were processed using a Gilson ASPEC system with solid-phase extraction of the crosslinks on columns containing 100 mg of microgranular cellulose. Introduction of an additional solvent step during sample preparation allowed direct analysis by reversed-phase HPLC and elimination of the drying step used previously in a manual method. Use of a synthetic pyridinoline derivative as internal standard enabled accurate quantification of the crosslinks by correcting for recoveries through the whole assay. Samples were analyzed in sequential mode with a total assay time of 30 min. The automated assay showed close correlation with the manual method for both free and total crosslink determinations in human urine (r > 0.97). Reproducibility was improved, as seen from replicate analyses of human urine (CV < 3% for automated pyridinoline measurement compared with 8-12% previously observed for the manual method). Crosslink excretion is the most useful marker of collagen degradation in metabolic bone diseases and arthritic disorders. The automated assay which has been developed is rapid, convenient, and reliable and will greatly facilitate the monitoring of urinary collagen crosslinks and their tissue levels in clinical investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号