首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Legionella spp. in Puerto Rico cooling towers.   总被引:1,自引:1,他引:0       下载免费PDF全文
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.  相似文献   

2.
M Koide  A Saito  N Kusano    F Higa 《Applied microbiology》1993,59(6):1943-1946
The presence of Legionella spp. in cooling tower water was investigated by using the polymerase chain reaction. Total Legionella spp. detection was performed with 20-mer 5S rRNA complementary DNA sequence primers, and specific Legionella pneumophila detection was performed with 20-mer and then 21-mer macrophage infectivity potentiator gene sequence primers. Of 27 cooling tower water samples, 25 were positive for Legionella spp., and 14 of these contained L. pneumophila.  相似文献   

3.
The dynamics of Legionella spp. and of dominant bacteria were investigated in water from a cooling tower plant over a 9-month period which included several weeks when Legionella pneumophila proliferated. The structural diversity of both the bacteria and the Legionella spp. was monitored by a fingerprint technique, single-strand conformation polymorphism, and Legionella spp. and L. pneumophila were quantified by real-time quantitative PCR. The structure of the bacterial community did not change over time, but it was perturbed periodically by chemical treatment or biofilm detachment. In contrast, the structure of the Legionella sp. population changed in different periods, its dynamics at times showing stability but also a rapid major shift during the proliferation of L. pneumophila in July. The dynamics of the Legionella spp. and of dominant bacteria were not correlated. In particular, no change in the bacterial community structure was observed during the proliferation of L. pneumophila. Legionella spp. present in the cooling tower system were identified by cloning and sequencing of 16S rRNA genes. A high diversity of Legionella spp. was observed before proliferation, including L. lytica, L. fallonii, and other Legionella-like amoebal pathogen types, along with as-yet-undescribed species. During the proliferation of L. pneumophila, Legionella sp. diversity decreased significantly, L. fallonii and L. pneumophila being the main species recovered.  相似文献   

4.
Cooling towers are considered to be man-made amplifiers of Legionella spp. Thus, the proper maintenance and choice of biocides is important. The only biocidal measure that has thus far been shown to be effective in field tests is the judicious use of chlorination. Perturbation studies with 1-bromo-3-chloro-5, 5-dimethylhydantoin (Bromicide; Great Lakes Chemical Corp., West Lafayette, Ind.) (BCD) were conducted on an industrial cooling tower shown to contain Legionella pneumophila. At the concentrations recommended by the manufacturer, neither the density nor the activity of L. pneumophila was affected. At comcentrations greater than 2.0 ppm (2.0 micorgram/ml) free of residual, BCD was not effective in reducing L. pneumophila to source water concentrations, nor was it effective in reducing the 2-p-iodophenyl-3-p-nitrophenyl-5-phenyl tetrazolium chloride activity of the bacterium in situ. The data indicate that at concentrations up to 2.0 ppm, BCD is not effective in these tower studies.  相似文献   

5.
Cooling towers are considered to be man-made amplifiers of Legionella spp. Thus, the proper maintenance and choice of biocides is important. The only biocidal measure that has thus far been shown to be effective in field tests is the judicious use of chlorination. Perturbation studies with 1-bromo-3-chloro-5, 5-dimethylhydantoin (Bromicide; Great Lakes Chemical Corp., West Lafayette, Ind.) (BCD) were conducted on an industrial cooling tower shown to contain Legionella pneumophila. At the concentrations recommended by the manufacturer, neither the density nor the activity of L. pneumophila was affected. At comcentrations greater than 2.0 ppm (2.0 micorgram/ml) free of residual, BCD was not effective in reducing L. pneumophila to source water concentrations, nor was it effective in reducing the 2-p-iodophenyl-3-p-nitrophenyl-5-phenyl tetrazolium chloride activity of the bacterium in situ. The data indicate that at concentrations up to 2.0 ppm, BCD is not effective in these tower studies.  相似文献   

6.
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

7.
Protocol for sampling environmental sites for legionellae.   总被引:4,自引:2,他引:2       下载免费PDF全文
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positive samples. Two of five cooling towers contained the same L. pneumophila serogroup 1 monoclonal type (1,2,4,5) as was isolated from patients. The same monoclonal type was also isolated from make-up water for the two cooling towers, a hot water tank, water separators in four main air compressor systems for respiratory therapy, and cold and hot water faucets. In hospital B, 13 of 37 (38%) sample sites contained legionellae, all of which were L. pneumophila serogroup 1. The monoclonal type matching isolates from patients (1,2,4,5) was found at the highest concentration in a hot water tank, but it was also present at four other sample sites. Since legionellae not related to disease may be found in many of the sites sampled, an epidemiologic association with the probable source should be established before intervention methods, such as disinfection, are undertaken.  相似文献   

8.
The combination of a Legionella pneumophila culture isolation technique and macrophage infectivity potentiator (mip) gene-specific nested polymerase chain reaction (PCR) is pivotal for effective routine use in an environmental water system laboratory. Detection of Legionella organisms in 169 environmental samples was performed by using modified buffered charcoal yeast extract (MBCYE) agar for conventional culture. Nested PCR specific for L. pneumophila was performed using boiled genomic DNA extracts from filtered and Chelex 100-treated water samples, or by using silica-gel membrane spin column-eluted DNA from concentrated pond, canal and river samples. Overall, the nested PCR was twelvefold more sensitive than the culture method. The target amplicons (471 basepairs) of all 4 biochemically characterized L. pneumophila isolates were sequenced. They had homology at the DNA and protein levels to 3' proximity of the mip-coding gene of L. pneumophila deposited in genome databases. EcoRI- or KpnI-digested PCR fragments with expected sizes were also confirmed in all 52 PCR-positive samples that were isolated from cooling towers and condenser drains. Viable but nonculturable L. pneumophila might have been present in 48 PCR-positive samples. This study demonstrates that detection of the genetically stable mip gene by nested PCR with a modified process of water sample preparation can be rapidly and effectively used to enhance isolation of the L. pneumophila taxon from microenvironments.  相似文献   

9.
Legionella contamination of dental-unit waters.   总被引:9,自引:1,他引:8       下载免费PDF全文
Water samples collected from 28 dental facilities in six U.S. states were examined for the presence of Legionella pneumophila and other Legionella spp. by the PCR-gene probe, fluorescent-antibody microscopic, and viable-plate-count detection methods. The PCR and fluorescent-antibody detection methods, which detect both viable and viable nonculturable Legionella spp., gave higher counts and rates of detection than the plate count method. By the PCR-gene probe detection method, Legionella spp. were detected in 68% of the dental-unit water samples and L. pneumophila was detected in 8%. Concentrations of Legionella spp. in dental-unit water reached 1,000 organisms per ml or more in 36% of the samples, and 19% of the samples were in the category of 10,000/ml or above. L. pneumophila, when present in dental-unit water, never reached concentrations of 1,000/ml or more. Microscopic examination with fluorescent-antibody staining indicated that the contamination was in the dental-unit water lines rather than in the handpieces. Legionella spp. were present in 61% of potable water samples collected for comparative analysis from domestic and institutional faucets and drinking fountains; this percentage was not significantly different from the rate of detection of Legionella spp. in dental-unit water. However, in only 4% of the potable water samples did Legionella spp. reach concentrations of 1,000 organisms per ml, and none was in the 10,000 organisms-per-ml category, and so health-threatening levels of Legionella spp. in potable water were significantly lower than in dental-unit water. L. pneumophila was found in 2% of the potable water samples, but only at the lowest detectable level.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
The occurrence and viable counts of Legionella pneumophila in acid-treated water samples of 62 cooling towers on the main island of Japan were determined by inoculating them onto plates of Wadowsky-Yee-Okuda (WYO) agar medium. WYO plate cultures of 39 (63%) of the samples yielded L. pneumophila with viable counts ranging from 10 to 10(4) colony-forming units per 100 ml. Of the L. pneumophila isolates, 157 were serologically identified as serogroup 1, and the remaining 21 were agglutinated by serogroup 3 (2 strains) and serogroup 6 (19 strains) antisera. In each culture-positive water sample, the pH and the number of other bacteria were found not be statistically significantly correlated with the viable counts of L. pneumophila. However, a higher rate of recovery of L. pneumophila was obtained with the water samples with a smaller number of other bacteria. Practical use of commercially available antialgal or antimicrobial agents was found not to be significantly effective for controlling the occurrence and growth of L. pneumophila in cooling tower water.  相似文献   

11.
Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.  相似文献   

12.
The purpose of the present study was to determine possible cross-reactivity between different serogroups or between different species by means of bacterial smears of individual L. pneumophila serogroups and several non-pneumophila Legionella spp. Using BIOCHIP slide we found a considerable frequency of cross-reactions with L. pneumophila serogroup 12 (88.4%) therefore BIOCHIP slide proved as useful method for identification of cross-reactivity between members of the Legionnellaceae.  相似文献   

13.
This study describes the development and evaluation of a specific Legionella pneumophila Taqman duplex real-time PCR (qPCR) for fast and reliable quantification of this human pathogen in suspected man-made water systems. The qPCR assay was 100% specific for all L. pneumophila serogroups 1-15 with a sensitivity of 60 genome units/l and an amplification efficiency of 98%. Amplification inhibitors were detected via an exogenous internal positive control, which was amplified simultaneously with L. pneumophila DNA using its own primer and probe set. Mean recovery rates of the qPCR assay for tap water and cooling circuit water, spiked with a known number L. pneumophila bacteria, were 93.0% and 56.3%, respectively. Additionally, by using the Ultraclean Soil DNA isolation kit, we were able to remove amplification inhibitors ubiquitously present in cooling water. The practical value of our qPCR assay was evaluated through analysis of 30 water samples from showers, taps, eyewash stations, fire sprinklers and recirculation loops with qPCR and traditional culture. In conclusion, the described L. pneumophila Taqman duplex real-time assay proved to be specific, sensitive and reproducible. This makes it a promising method complementing the current time-consuming culture standard method.  相似文献   

14.
A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of > or =10(3) CFU liter(-1), and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed.  相似文献   

15.
The disinfection of cooling towers based on manufacturers' treatment protocols, as employed in units installed at various public gathering places in Dallas, Tex. (hotels, municipal auditorium), and at the city health department, was evaluated for effectiveness in controlling Legionella pneumophila and compared with previous laboratory studies. In specimens collected in September and December, 1978, L. pneumophila was isolated from 2 of 4 specimens from untreated cooling towers, 2 of 4 specimens from towers treated with agents deemed ineffective in earlier laboratory tests, 6 of 11 specimens from towers treated with putatively effective agents, and 0 of 4 specimens from towers treated with an agent unknown efficacy. These results suggest the need for further studies to identify biocidal agents effective in eliminating L. pneumophila from air-conditioning cooling towers.  相似文献   

16.
The effect of Aeromonas strains on the growth of Legionella   总被引:1,自引:0,他引:1  
Thirty-one environmental and two type strains of Aeromonas were tested for their ability to inhibit the growth of strains of several Legionella species. Of 10 Legionella spp. tested, only Legionella pneumophila and Leg. longbeachae were able to resist the inhibitory effects of some of the Aeromonas strains. Selected Aeromonas strains were also tested for their ability to inhibit the growth of several non-legionella strains. None of the non-legionella strains were inhibited by any of the selected Aeromonas strains. Attempts were made to isolate Aeromonas strains from cooling towers and Aeromonas hydrophila was isolated from one of the cooling towers tested. The results suggest that many strains of Aeromonas can inhibit the growth of Legionella strains on solid media and could affect the isolation of legionellas from water sources.  相似文献   

17.
A preliminary survey of water systems in hospitals and hotels showed that Legionella pneumophila may be found in water storage and distribution systems as well as in the recirculating cooling water of air-conditioning plants. Altogether 42 isolates of L pneumophila were made from 31 establishments, six of which were associated with cases of legionnaires'' disease but in 25 of which there was no known association with disease. In the six establishments implicated epidemiologically as the source of legionnaires'' disease, these organisms were found in each of their water-distribution systems and also in the cooling water from each of the three with cooling towers. In establishments not associated with cases, water from three out of nine cooling towers, four out of 24 taps or showers, and one out of 15 storage tanks was found to contain legionellae. The organisms were isolated by guinea-pig inoculation and subsequent culture of their peritoneal fluid, liver, and spleen. Finding L pneumophila in water systems in the absence of cases of legionnaires'' disease should not at present be an indication for attempts at eradication.  相似文献   

18.
We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.  相似文献   

19.
We evaluated two commercial enzyme immunoassay kits, Binax EIA (for detection of soluble antigen of Legionella pneumophila serogroup 1) and Biotest EIA (for detection of antigens of Legionella pneumophila serogroups and other Legionella spp.) in order to introduce this test routinely for the diagnosis of Legionnaires' disease (LD) in our Laboratory. Frozen non-concentrated urine samples belonging to 45 patients with and without LD were tested. The sensitivity of Binax EIA and Biotest EIA was 47.4% and 42.1% respectively, the specificity was 95% by both tests. Biotest did not detect antigen from a patient with culture-proven infection of L. pneumophila serogroup 6. The detection of urinary antigen by both EIA tests is a useful tool for rapid diagnosis of LD, especially when samples are unavailable for culture; the sensitivity may be increased if the assay is performed on unfrozen and concentrated samples.  相似文献   

20.
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggests that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号