首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Use of silica stationary phase and aqueous–organic mobile phases could significantly enhance LC–MS–MS method sensitivity. The LC conditions were compatible with MS detection. Analytes with basic functional groups were eluted with acidic mobile phases and detected by MS in the positive ion mode. Analytes with acid functional groups were eluted with mobile phases at neutral pH and detected by MS in the negative ion mode. Analytes poorly retained on reversed-phase columns showed good retention on silica columns. Compared with reversed-phase LC–MS–MS, 5–8-fold sensitivity increases were observed for basic polar ionic compounds when using silica columns and aqueous–organic mobile phase. Up to a 20-fold sensitivity increase was observed for acidic polar ionic compounds. Silica columns and aqueous–organic mobile phases were used for assaying nicotine, cotinine, and albuterol in biological fluids.  相似文献   

2.
This paper evaluates the performances of reversed-phase (RPLC) and ion-pairing chromatography (IPLC) coupled with UV detection for the analysis of a set of 12 catecholamines and related compounds. Different chromatographic columns (porous C18-silica, perfluorinated C18-silica, porous graphitic carbon, monolithic and fused-core silica-based C18 columns) were tested using semi-long perfluorinated carboxylic acids as volatile ion-pairing reagents. Much more promising results were obtained by IPLC than by RPLC and important improvements in analytes peak symmetry and separation resolution were observed when using the "fast chromatography" columns (monolithic and fused-core C18) under IPLC conditions. For UV detection, a satisfactory separation of the 12 selected analytes was achieved in less than 20 min by using a fused-core particles column (Halo C18) and a mobile phase composed of a 1.25 mM nonafluoropentanoic acid aqueous solution and methanol under gradient elution mode. The chromatographic method developed can be directly coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS) in positive ionization mode and 10 solutes among those selected can be observed. The presence of the acidic ion-pairing reagent in the mobile phase makes this system incompatible with negative ionization mode and thus unable to detect the two acidic compounds that only responded in negative mode. In terms of MS detection, Monolithic C18 column proved to be the best one to reach the lowest detection limits (LODs) (from 0.5 ngmL(-1) to 10 ngmL(-1) depending on the neurotransmitter). The applicability of the optimized LC-MS/MS method to a "real world" sample was finally evaluated. The presence of the matrix leads to signal suppression for several solutes and thus to higher LODs.  相似文献   

3.
Two different columns—Lux Cellulose-1 and Chiralpak CBH—were evaluated for their chiral recognition abilities for eight drugs comprising three β-blockers, one antacid, and four cathinones in polar-organic elution mode and reversed-phase elution mode, respectively. The factors that affected the enantioseparation were tested and optimized to develop a suitable chiral separation method whose LC conditions are compatible with MS detection. In polar-organic elution mode with the Lux Cellulose-1 column, methanol and acetonitrile were tested as the main components of the mobile phase. In addition, the effects of adding isopropanol as organic modifier, acidic additives (formic acid), and basic additives (diethylamine) were evaluated. In reversed-phase elution mode with the Chiralpak CBH column, the effect of type and concentration of organic modifier (isopropanol, acetonitrile, and methanol), the mobile phase pH (6.4 and 5.0), and buffer concentration (1mM-20mM ammonium acetate) were evaluated. The best enantioseparation was achieved with the Chiralpak CBH column with a mobile phase composed of 5mM ammonium acetate aqueous (pH = 6.4)/methanol (95/5, v/v) at a flow rate of 0.1 mL/min and a temperature of 30°C. Under these conditions, six of eight chiral drugs were baseline separated.  相似文献   

4.
The enantioseparation of ezetimibe stereoisomers by high‐performance liquid chromatography on different chiral stationary phases, ie, 3 polysaccharide‐based chiral columns, was studied. It was observed that cellulose‐based Chiralpak IC column exhibited the best resolving ability. After the optimization of mobile phase compositions in both normal and reversed phase modes, satisfactory separation could be obtained on Chiralpak IC column, especially in normal phase mode. The use of prohibited solvents as nonstandard mobile phase gave rise to better resolution than that of standard mobile phases (n‐hexane/alcohol system). In addition, the presence of ethanol in nonstandard mobile phase has played an important role in enhancing chromatographic efficiency and resolution between ezetimibe stereoisomers. Various attempts were made to comprehensively compare the chiral recognition capabilities of immobilized versus coated polysaccharide‐based chiral columns, amylose‐based versus cellulose‐based chiral stationary phases, reversed versus normal phase modes, and standard versus nonstandard mobile phases. Moreover, possible solute‐mobile phase‐stationary phase interactions were derived to explain how stationary and mobile phases affected the separation. Then the method validation with respect to selectivity, linearity, precision, accuracy, and robustness was carried out, which was demonstrated to be suitable and accurate for the quantitative determination of (RRS)‐ezetimibe impurity in ezetimibe bulk drug.  相似文献   

5.
Rolled stationary phases are fabrics (i.e., nonparticulate phases) that rapidly separate proteins from salts on the basis of size exclusion. Pore size and pore size distributions in the stationary phase determine how different size molecules distribute between the stationary and mobile phases in liquid chromatography columns. The potential for size exclusion chromatography by fabrics is not initially obvious because their interlaced structures are atypical for size exclusion supports. A simple logistic model fits the pore size distribution of a rolled stationary phase when pore sizes were measured using PEG, Dextran, D2O, glucose, and NaCl probes. When the fabric is treated with cellulase enzymes, the water-accessible pores uniformly decrease and peak retention is lower. The logistic function model captures this result and enables comparison of pore size distribution curves between enzyme-treated and untreated fabrics in rolled stationary phase columns.  相似文献   

6.
Rate‐limited sorption/desorption can have a profound effect upon the transport of sorbing contaminants. Numerical and analytical models used to predict chemical movement through the subsurface rarely incorporate the effects of nonlinear sorption and desorption kinetics, resulting in potentially large overestimates of mass extractability. Mass transfer characteristics of arsenic‐contaminated soils at the site of a former arsenical herbicide manufacturer in Houston, Texas, were examined in the laboratory using soil columns. Unaffected soils comprised of silty sands to coarse sands were collected from the uppermost aquifer. Two soil columns were loaded with a known mass of mixed organic and inorganic forms of arsenic resident in site ground water. A third control column was prepared with dry 20 × 30 mesh ASTM silica sand. Leachate samples were collected from each void volume until arsenic breakthrough was achieved. The dynamic test applied a continuing head of water, operating in an upflow mode through 4‐in. diameter by 12‐in. long soil columns repacked to in situ density. A flow‐through velocity of one void volume per day was chosen for arsenic loading to the columns and 0.08 void volume per day during the desorption phase of the test. Uncontaminated ground water was then passed through the columns, and the tests were restarted in the desorption mode. Analysis of the leachate and resulting arsenic concentrations in the test columns allowed for the calculation of distribution coefficients that describe arsenic behavior. Measured distribution coefficients during desorption ranged from 0.26 after one void volume to 3.3 after six void volumes had been passed through the column.  相似文献   

7.
The complexity and diversity of biological samples in proteomics require intensive fractionation ahead of mass spectrometry identification. This work developed a chromatographic method called virtual three-dimensional chromatography to fractionate complex protein mixtures. By alternate elution with different pHs and salt concentrations, we implemented pH and salt steps by turns on a single strong cation exchange column to fully exploit its chromatographic ability. Given standard proteins that were not resolved solely by pH or salt gradient elution could be successfully separated using this combined mode. With a reversed phase column tandem connected behind, we further fractionated as well as desalted proteins as the third dimension. This present strategy could readily be adapted with respect to special complexity of biological samples. Crude plasma without depleting high abundance proteins were fractionated by this three-dimensional mode and then analyzed by reversed phase liquid chromatography coupled with LTQ mass spectrometry. In total, 1933 protein groups with wide dynamic ranges were identified from a single experiment. Some characteristics that correlated to the behavior of proteins on strong cation exchange columns are also discussed.  相似文献   

8.
In former studies, dinucleoside polyphosphates were quantified using ion-pair reversed-phase perfusion chromatography columns, which allows a detection limit in the micromolar range. The aim of this study was both to describe a chromatographic assay with an increased efficiency of the dinucleoside separation, which enables the reduction of analytical run times, and to establish a chromatographic assay using conditions, which allow MALDI-mass spectrometric analysis of the resulting fractions. We compared the performance of conventional silica reversed phase chromatography columns, a perfusion chromatography column and a monolithic reversed-phase C18 chromatography column. The effects of different ion-pair reagents, flow-rates and gradients on the separation of synthetic diadenosine polyphosphates as well as of diadenosine polyphosphates isolated from human platelets were analysed. Sensitivity and resolution of the monolithic reversed-phase chromatography column were both higher than that of the perfusion chromatography and the conventional reversed phase chromatography columns. Using a monolithic reversed-phase C18 chromatography column, diadenosine polyphosphates were separable baseline not only in the presence of tetrabutylammonium hydrogensulfate (TBA) but also in the presence of triethylammonium acetate (TEAA) as ion-pair reagent. The later reagent is useful because, in contrast to TBA, it is compatible with MALDI mass-spectrometric methods. This makes TEAA particularly suitable for identification of unknown nucleoside polyphosphates. Furthermore, because of the lower backpressure of monolithic reversed-phase chromatography columns, we were able to significantly increase the flow rate, decreasing the amount of time for the analysis close to 50%, especially using TBA as ion-pair reagent. In summary, monolithic reversed phase C18 columns markedly increase the sensitivity and resolution of dinucleoside polyphosphate analysis in a time-efficient manner compared to reversed-phase perfusion chromatography columns or conventional reversed-phase columns. Therefore, further dinucleoside polyphosphate analytic assays should be based on monolithic silica C18 columns instead of perfusion chromatography or conventional silica reversed phase chromatography columns. In conclusion, the use of monolithic silica C18 columns will lead to isolation and quantification of up to now unknown dinucleoside polyphosphates. These chromatography columns may facilitate further research on the biological roles of dinucleoside polyphosphates.  相似文献   

9.
Molecularly imprinted polymers (MIPs) for the recognition of enalapril and lisinopril were prepared using 4-vinylpyridine as the functional monomer. Following thermal polymerisation the resulting materials were crushed, ground and sieved. First generation MIPs were produced in protic polar porogenic solvents (mixture of methanol (MeOH) and acetonitrile (ACN)). These MIPs were used and validated as sorbents for solid phase extraction and binding assays. Second generation MIPs were produced with polar aprotic porogenic solvent (DMSO). These polymers were packed in HPLC columns in order to investigate their molecular recognition properties in a dynamic mode. The study of the mobile phase composition included two major parameters: organic modifier content and pH value. Retention factors illustrate selective binding of the template from the imprinted polymers, compared to structurally related compounds.  相似文献   

10.
Peptides, proteins, single-stranded oligonucleotides, and double-stranded DNA fragments were separated with high resolution in micropellicular, monolithic capillary columns prepared by in situ radical copolymerization of styrene and divinylbenzene. Miniaturized chromatography both in the reversed-phase and the ion-pair reversed-phase mode could be realized in the same capillary column because of the nonpolar character of the poly-(styrene/divinylbenzene) stationary phase. The high chromatographic performance of the monolithic stationary phase facilitated the generation of peak capacities for the biopolymers in the range of 50-140 within 10 min under gradient elution conditions. Employing volatile mobile phase components, separations in the two chromatographic separation modes were on-line hyphenated to electrospray ionization (tandem) mass spectrometry, which yielded intact accurate molecular masses as well as sequence information derived from collision-induced fragmentation. The inaccuracy of mass determination in a quadrupole ion trap mass spectrometer was in the range of 0.01-0.02% for proteins up to a molecular mass of 20000, and 0.02-0.12% for DNA fragments up to a molecular mass of 310000. High-performance liquid chromatography-electrospray ionization mass spectrometry utilizing monolithic capillary columns was applied to the identification of proteins by peptide mass fingerprinting, tandem mass spectrometric sequencing, or intact molecular mass determination, as well as to the accurate sizing of double-stranded DNA fragments ranging in size from 50 to 500 base pairs, and to the detection of sequence variations in DNA fragments amplified by the polymerase chain reaction.  相似文献   

11.
Selenite reduction by a bacterial consortium enriched from an oil refinery waste sludge was studied under denitrifying conditions using acetate as the electron donor. Fed-batch studies with nitrate as the primary electron acceptor showed that accumulation of nitrite led to a decrease in the extent of selenite reduction. Also, when nitrite was added as the primary electron acceptor, rapid selenite reduction was observed only after nitrite was significantly depleted from the medium. These results indicate that selenite reduction was inhibited at high nitrite concentrations. In addition to batch experiments, continuous-flow selenite reduction experiments were performed in packed-bed columns using immobilized enrichment cultures. These experiments were carried out in three phases: in phase I, a continuous nitrate feed with different inlet selenite concentration was applied; in phase II, nitrate was fed in a pulsed fashion; and in phase III, nitrate was fed in a continuous mode but at much lower concentrations than the other two phases. During the phase I experiments, little selenite was removed from the influent. However, when the column was operated in the pulse feed strategy (phase II) or in the continuous mode with low nitrate levels (phase III), significant quantities of selenium were removed from solution and retained in the immobilization matrix in the column. Thus, immobilized denitrifying cultures can be effective in removing selenium from waste streams, but nitrate-limited operating conditions might be required.  相似文献   

12.
Direct high‐performance liquid chromatographic (HPLC) separation of four bicyclo[2.2.2]octane based 2‐amino‐3‐carboxylic acid enantiomers were developed on chiral stationary phases (CSPs) containing different macrocyclic glycopeptide antibiotic selectors. The analyses were performed under reversed‐phase, polar organic and polar ionic mode on macrocyclic‐glycopeptide‐based Chirobiotic T, T2, TAG, and R columns. The effects of the mobile phase composition including the acid and base modifier, the structure of the analytes, and the temperature on the separations were investigated. Experiments were achieved at constant mobile phase compositions on different stationary phases in the temperature range 5–40°C. Thermodynamic parameters were calculated from plots of ln k or ln α versus 1/T. It was recognized that the enantioseparations in reversed‐phase and polar organic mode were enthalpically driven, but under polar‐ionic conditions entropically driven enantioseparation was observed as well. Baseline separation and determination of elution sequence were achieved in all cases. Chirality 26:200–208, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

13.
Since the NAD metabolite ADP-ribose (ADPR) has recently gained attention as a putative messenger, a method was established for the quantification of intracellular ADPR by reversed-phase HPLC. Cellular nucleotides were extracted with trichloroacetic acid, and crude cell extracts purified by solid phase extraction using a strong anion exchange matrix. After optimization of the extraction procedure, cellular ADPR levels were determined using two different reversed-phase columns (C18 versus C12), operated in ion pair mode. Intracellular ADPR concentrations in human Jurkat T-lymphocytes and murine BW5147 thymocytes were determined to be 44+/-11 microM and 73+/-11 microM, respectively.  相似文献   

14.
Hydroxymethyl methacrylate-based monolithic columns for separation of oligonucleotides by capillary liquid chromatography (CLC) were prepared. We optimized composition of the polymerization mixture, which contained the monomer mixture consisting of N-(hydroxymethyl) methacrylamide (HMMAA) and ethylene dimethacrylate (EDMA), and the porogenic system composed of propane-1-ol, butane-1,4-diol and alpha, alpha'-azoisobutyronitrile (AIBN) as initiator. Separations of oligonucleotides were performed in HILIC (hydrophilic-interaction) mode using 100 mM triethylamine acetate (TEAA) in acetonitrile and in water as eluents. The influence of steepness of the mobile phase gradient on separation of the oligonucleotides was evaluated as well as the reproducibility of HMMAA monolith preparation.  相似文献   

15.
The initiation of the respiratory burst and the degranulation of human polymorphonuclear leukocytes (PMN) in response to stimulation by uropathogenic strains of Escherichia coli is dependent on the expression of Type 1 fimbriae by those strains. These PMN responses correlate with an increasing tendency of the interacting E. coli strain to be retained on hydrophobic columns. The present work assessed the measurement of relative surface hydrophobicity in relation to PMN activation. Type 1 fimbriate organisms bound most readily to Octyl-Sepharose columns and were strongly agglutinated in the salt aggregation test. In contrast, the same organisms partitioned to the dextran-rich (hydrophilic) phase of aqueous two-polymer phase systems. Electron microscopic observation of the organisms eluted from the Octyl-Sepharose columns and of the organisms recovered from both phases of the aqueous two-phase systems demonstrated, however, that both Type 1 and P-fimbriate organisms were retained on the columns and partitioned into the dextran-rich phase as a consequence of their being fimbriate and failed to identify this as a major factor in the activation of PMN. In addition electron microscopy demonstrated that each P-fimbriate population had fewer organisms expressing fimbriae than did Type 1 fimbriate populations, confirming the importance of phase variation as a factor affecting the physicochemical characteristics of a bacterial population.  相似文献   

16.
The application of cellulose-based stationary phases for chiral separations has been extended to open tubular column chromatography. Efficient columns were obtained by coating the capillaries with mixtures of chiral cellulose materials and conventional achiral stationary phases for gas chromatography. In this study, various siloxane and polyethylene glycol polymers were used as achiral components and mixed with different substituted benzoylcellulose derivatives as chiral components. Systematic investigations were carried out to determine the optimal ratio for the components of the stationary phase. Depending on the chromatographic mode—gas chromatography (GC) or supercritical fluid chromatography (SFC)—the stationary phases were found to behave differently. The applicability of the technique was demonstrated by the resolution of various racemic compounds. © 1993 Wiley-Liss, Inc.  相似文献   

17.
Xia YQ  Liu DQ  Bakhtiar R 《Chirality》2002,14(9):742-749
An online sample extraction chiral bioanalytical method was developed and validated for the quantification of terbutaline, a beta2-selective adrenoceptor agonist, spiked into human plasma by using two extraction columns and a chiral stationary phase (CSP) in conjunction with liquid chromatography tandem mass spectrometry (LC-MS/MS). In this method, two Oasis HLB extraction columns were used in parallel for plasma sample purification and a Chirobiotic T CSP was used for enantiomeric separation. Atmospheric pressure chemical ionization MS/MS was employed in multiple reaction monitoring mode for the detection and quantification. Subsequent to the addition of an internal standard solution, the plasma samples were directly injected onto the system for extraction and analysis. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for reconditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a shorter run time and higher throughput. A lower limit of quantification of 1.0 ng/mL was achieved using only 50 microliter of human plasma. The method was validated with a dynamic range of 1.0-200 ng/mL. The intra- and interday precision was no more than 11% CV and the assay accuracy was between 94-106%.  相似文献   

18.
A procedure based on liquid chromatography-mass spectrometry (LC-MS) is described for determination of 6-monoacetylmorphine, morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, cocaine, benzoylecgonine and cocaethylene in meconium using nalorfine as the internal standard. The analytes are initially extracted from the matrix by methanol (6-monoacetylmorphine, morphine, codeine, cocaine, benzoylecgonine and cocaethylene) or 0.01 M ammonium hydrogen carbonate buffer (morphine-3-glucuronide, morphine-6-glucuronide). Subsequently a solid-phase extraction with Bondelut Certify columns (6-monoacetylmorphine, morphine, codeine, cocaine, benzoylecgonine and cocaethylene) or ethyl solid-phase extraction columns (morphine-3-glucuronide, morphine-6-glucuronide) was applied. Chromatography was performed on a C(8) reversed-phase column using a gradient of acetic acid 1%-acetonitrile as a mobile phase. Analytes were determined in LC-MS single ion monitoring mode with atmospheric pressure ionisation-electrospray (ESI) interface. The method was validated in the range 0.005-1.00 microg/g using 1 g of meconium per assay and applied to analysis of meconium in newborns to assess fetal exposure to opiates and cocaine.  相似文献   

19.
High-performance liquid chromatographic methods were developed for the separation of the enantiomers of 12 beta-lactams. Direct separations were performed on chiral stationary phases (CSPs) containing cellulose-tris-3,5-dimethylphenyl carbamate (Chiralcel OD-RH and OD-H columns), the macrocyclic glycopeptide antibiotic teicoplanin (Chirobiotic T column), or teicoplanin aglycone (Chirobiotic TAG column) as the chiral selector. It was clearly established that, with teicoplanin-based columns, the teicoplanin aglycone was most often responsible for the enantioseparation of the beta-lactams. The difference in enantioselective free energy between the aglycone CSP and the teicoplanin CSP was in the range between 0.02 and 0.97 kJ mol(-1) for these beta-lactam stereoisomer separations. The separations were carried out with high selectivity and resolution, and the method was therefore suitable for monitoring of the enantiomeric excess after chiral synthesis. The Chirobiotic and Chiralcel columns appear to be highly complementary to one another. The best separation of this class of beta-lactam compound could be obtained using the Chirobiotic TAG in the polar-organic mode plus the Chiralcel OD-H in the normal-phase mode. The elution sequence was also determined.  相似文献   

20.
The chiral selector vancomycin was used either as mobile phase additive or bound as a chiral stationary phase (CSP) for the stereoselective separation of seven racemic nonsteroidal anti-inflammatory drugs (NSAIDs), fenoprofen, carprofen, flurbiprofen, indoprofen, flobufen, ketoprofen, and suprofen, by capillary liquid chromatography. The effect of the type of stationary phase, the chiral column Chirobiotic V or the achiral stationary phases Nucleosil 100 C8 HD and Nucleosil 100 C18 HD, and the concentration of vancomycin in the mobile phase on separation of the drug enantiomers were evaluated. All the drugs, except flobufen, were successfully enantioseparated on Nucleosil 100 C8 HD with 4 mM vancomycin present in the mobile phase (composed of methanol and buffer) in the reversed phase mode. On the vancomycin-bonded chiral stationary phase, it was difficult to get enantioseparations of the profen NSAIDs. However, flobufen gave better enantioseparation on the vancomycin CSP. The better enantioresolution of the majority of profen derivatives on the achiral columns with vancomycin added to the mobile phase can be attributed in particular to the higher separation efficiency of this capillary chromatographic system. In addition, vancomycin dimers, formed in the mobile phase, seem to offer a better steric arrangement for stereoselective interaction to these analytes than the vancomycin bonded on the CSP. These substantial differences in the CS structure significantly influence the chiral discrimination mechanism.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号