1.
In the present study, the fixation system of a femoral medullary nail connection was investigated. In surgical treatment of fractured femurs, the fracture is bridged by a medullary nail that is fixed by interlocking screws in the bone. Bone failure around these screws is the most common complication associated with the treatment of fractures of osteoporotic bone. The present study analyses the stresses present in the region of the implant/bone system. Three-dimensional finite element models were generated, a nonlinear structure analysis performed, and the stresses at material interfaces investigated. The highest concentration of stresses is to be found in the middle of the interlocking screws and the holes drilled in the bone. This is in agreement with the results of experimental investigations.  相似文献   

2.
This study investigates the effect of the pilot hole size, implant depth, synthetic bone density, and screw size on the pullout strength of the self-tapping screw using analytical, finite element, and experimental methodologies. Stress distribution and failure propagation mode around the implant thread zone are also investigated. Based on the finite element analysis (FEA) results, an analytical model for the pullout strength of the self-tapping screw is constructed in terms of the (synthetic) bone mechanical properties, screw size, and the implant depth. The pullout performance of self-tapping screws is discussed. Results from the analytical and finite element models are experimentally validated.  相似文献   

3.
Finite element analysis is a useful analytical tool for the design of biomedical implants. The aim of this study was to investigate the behavior of temporomandibular joint implants with multiple design variables of the screws used for fixation of the implant. A commercially available implant with full mandible was analyzed using a finite element software package. The effects of different design variables such as orientation, diameter and stem length of the screws on the stress distribution in bone for two different surgical procedures were investigated. Considering the microstrain in bone as a principal factor, the acceptable ranges for screw diameter and length were determined. Parallel orientation of the screws performed better from a stress point of view when compared to the zig-zag orientation. Sufficient contact between the implant collar and mandibular condyle was shown to reduce the peak stresses which may lead to long term success. The distance between screw holes in the parallel orientation was much closer when compared to the zig-zag orientation. However, the stresses in bone near the screw hole area for the parallel orientation were within acceptable limits.  相似文献   

4.
Small endosseous implants, such as screws, are important components of modern orthopedics and dentistry. Hence they have to reliably fulfill a variety of requirements, which makes the development of such implants challenging. Finite element analysis is a widely used computational tool used to analyze and optimize implant stability in bone. For these purposes, bone is generally modeled as a continuum material. However, bone failure and bone adaptation processes are occurring at the discrete level of individual trabeculae; hence the assessment of stresses and strains at this level is relevant. Therefore, the aim of the present study was to investigate how peri-implant strain distribution and load transfer between implant and bone are affected by the continuum assumption. We performed a computational study in which cancellous screws were inserted in continuum and discrete models of trabecular bone; axial loading was simulated. We found strong differences in bone-implant stiffness between the discrete and continuum bone model. They depended on bone density and applied boundary conditions. Furthermore, load transfer from the screw to the surrounding bone differed strongly between the continuum and discrete models, especially for low-density bone. Based on our findings we conclude that continuum bone models are of limited use for finite element analysis of peri-implant mechanical loading in trabecular bone when a precise quantification of peri-implant stresses and strains is required. Therefore, for the assessment and improvement of trabecular bone implants, finite element models which accurately represent trabecular microarchitecture should be used.  相似文献   

5.
The response of bovine bone to the presence of an implant is analysed with the aim of simulating bone remodelling in a developing model of a polymeric intramedullary interlocking nail for veterinary use. A 3-D finite element model of the femur diaphysis is built based on computed tomography images and using a CAD-based modelling pipeline. The bone remodelling process after the surgery is analysed and compared with the healthy bone. The remodelling law assumes that bone adapts to the mechanical environment. For the analyses a consistent set of loads is determined for the bovine walk cycle. The remodelling results reproduce the morphologic features of bone and provide evidence of the difference on the bone behaviour when comparing metallic and polymeric nails. Our findings indicate that an intramedullary polymeric nail has the advantage over the metallic one of improving long-term bone healing and possibly avoiding the need of the implant removal.  相似文献   

6.
Trabecular alignment theory has been used to quantify Wolff's Law of bone remodeling. A three-dimensional finite element scheme was developed to analyze the bone remodeling phenomenon. The mathematical model proposed by Mullender et al. and later modified by Smith et al. was adopted to simulate the surface-based trabecular resorption and formation processes. Enhancements incorporated into the previous model include: mapping into three-dimensions, controlling the remodeling signal's passage through marrow, controlling the finite distance the signal may pass through the bone matrix, and including non-bone material in the finite element model. After the model is explained and thoroughly studied, three-dimensional implant surface geometries are simulated.  相似文献   

7.
The first objective of this computational study was to assess the strain magnitude and distribution within the three-dimensional (3D) trabecular bone structure around an osseointegrated dental implant loaded axially. The second objective was to investigate the relative micromotions between the implant and the surrounding bone. The work hypothesis adopted was that these virtual measurements would be a useful indicator of bone adaptation (resorption, homeostasis, formation).In order to reach these objectives, a μCT-based finite element model of an oral implant implanted into a Berkshire pig mandible was developed along with a robust software methodology. The finite element mesh of the 3D trabecular bone architecture was generated from the segmentation of μCT scans. The implant was meshed independently from its CAD file obtained from the manufacturer. The meshes of the implant and the bone sample were registered together in an integrated software environment. A series of non-linear contact finite element (FE) analyses considering an axial load applied to the top of the implant in combination with three sets of mechanical properties for the trabecular bone tissue was devised. Complex strain distribution patterns are reported and discussed. It was found that considering the Young’s modulus of the trabecular bone tissue to be 5, 10 and 15 GPa resulted in maximum peri-implant bone microstrains of about 3000, 2100 and 1400. These results indicate that, for the three sets of mechanical properties considered, the magnitude of maximum strain lies within an homeostatic range known to be sufficient to maintain/form bone. The corresponding micro-motions of the implant with respect to the bone microstructure were shown to be sufficiently low to prevent fibrous tissue formation and to favour long-term osseointegration.  相似文献   

8.
Stress shielding is a biomechanical phenomenon causing adaptive changes in bone strength and stiffness around metallic implants, which potentially lead to implant loosening. Accordingly, there is a need for standard, objective engineering measures of the “stress shielding” performances of an implant that can be employed in the process of computer-aided implant design. To provide and test such measures, we developed hierarchical computational models of adaptation of the trabecular microarchitecture at different sites in the proximal femur, in response to insertion of orthopaedic screws and in response to hypothetical reductions in hip joint and gluteal muscle forces. By identifying similar bone adaptation outcomes from the two scenarios, we were able to quantify the stress shielding caused by screws in terms of analogous hypothetical reductions in hip joint and gluteal muscle forces. Specifically, we developed planar lattice models of trabecular microstructures at five regions of interest (ROI) in the proximal femur. The homeostatic and abnormal loading conditions for the lattices were determined from a finite element model of the femur at the continuum scale and fed to an iterative algorithm simulating the adaptation of each lattice to these loads. When screws were inserted to the femur model, maximal simulated bone loss (17% decrease in apparent density, 10% decrease in thickness of trabeculae) was at the greater trochanter and this effect was equivalent to the effect of 50% reduction in gluteal force and normal hip joint force. We conclude that stress shielding performances can be quantified for different screw designs using model-predicted hypothetical musculoskeletal load fractions that would cause a similar pattern and extent of bone loss to that caused by the implants.  相似文献   

9.
Lateralizing the center of rotation (COR) of reverse total shoulder arthroplasty (rTSA) could improve functional outcomes and mitigate scapular notching, a commonly occurring complication of the procedure. However, resulting increases in torque at the bone-implant interface may negatively affect initial fixation of the glenoid-side component, especially if only two fixation screws can be placed. Shoulder-specific finite element (FE) models of four fresh-frozen cadaveric shoulders were constructed. Scapular geometry and material property distributions were derived from CT data. Generic baseplates with two and four fixation screws were virtually implanted, after which superiorly-oriented shear loads, accompanied by a compressive load, were applied incrementally further from the glenoid surface to simulate lateralization of the COR. Relationships between lateralization, adduction range of motion (ROM), the number of fixation screws and micromotion of the baseplate (initial implant fixation) were characterized. Lateralization significantly increases micromotion (p=0.015) and adduction ROM (p=0.001). Using two, versus four, baseplate fixation screws significantly increases micromotion (p=0.008). The effect of lateralization and the number of screws on adduction ROM and baseplate fixation is variable on a shoulder-specific basis. Trade-offs exist between functional outcomes, namely adduction ROM, and initial implant fixation and the negative effect of lateralization on implant fixation is amplified when only two fixation screws are used. The possibility of lateralizing the COR in order to improve functional outcomes of the procedure should be considered on a patient-specific basis accounting for factors such as availability and quality of bone stock.  相似文献   

10.
Stress shielding is a biomechanical phenomenon causing adaptive changes in bone strength and stiffness around metallic implants, which potentially lead to implant loosening. Accordingly, there is a need for standard, objective engineering measures of the "stress shielding" performances of an implant that can be employed in the process of computer-aided implant design. To provide and test such measures, we developed hierarchical computational models of adaptation of the trabecular microarchitecture at different sites in the proximal femur, in response to insertion of orthopaedic screws and in response to hypothetical reductions in hip joint and gluteal muscle forces. By identifying similar bone adaptation outcomes from the two scenarios, we were able to quantify the stress shielding caused by screws in terms of analogous hypothetical reductions in hip joint and gluteal muscle forces. Specifically, we developed planar lattice models of trabecular microstructures at five regions of interest (ROI) in the proximal femur. The homeostatic and abnormal loading conditions for the lattices were determined from a finite element model of the femur at the continuum scale and fed to an iterative algorithm simulating the adaptation of each lattice to these loads. When screws were inserted to the femur model, maximal simulated bone loss (17% decrease in apparent density, 10% decrease in thickness of trabeculae) was at the greater trochanter and this effect was equivalent to the effect of 50% reduction in gluteal force and normal hip joint force. We conclude that stress shielding performances can be quantified for different screw designs using model-predicted hypothetical musculoskeletal load fractions that would cause a similar pattern and extent of bone loss to that caused by the implants.  相似文献   

11.
Good mechanical fixation of an implant to the surrounding bone is important for its longevity, and is influenced by both biological and mechanical factors. This study parametrically evaluates the mechanics of the interface with a computationally efficient analytic structural model of the shear stress field and global shear stiffness of an axially loaded implant. The utility of the analytic model was first established by validating its assumptions with a case-specific finite element model. We then used the analytic model for a sensitivity analysis of the relationship between the pattern of tissue growth and shear properties of the interface for our previously reported loaded in vivo experimental micromotion device. The bone located directly at the implant surface was found to be the most effective site for increasing interface stiffness. This suggests that the implant surface is the most desirable site for bone growth, yet is also the most mechanically challenging environment due to its maximal shear stresses. Thus, these findings support the further investigation of osteo-conductive coatings and other biological stimuli to overcome the challenging mechanics, and to promote bone growth directly at the implant surface. The model also demonstrated that the mechanical contribution to the global implant shear stiffness of a commonly observed isolated sclerotic bone rim is very limited. The results of this sensitivity analysis agree with experimental studies with the micromotion device, and with clinical studies reporting good results with osteo-conductive coatings.  相似文献   

12.
The main objective of this work is the evaluation, by means of the finite element method (FEM) of the mechanical stability and long-term microstructural modifications in bone induced to three different kinds of fractures of the distal femur by three types of implants: the Condyle Plate, the less invasive stabilization system plate (LISS) and the distal femur nail (DFN). The displacement and the stress distributions both in bone and implants and the internal bone remodelling process after fracture and fixation are obtained and analysed by computational simulation. The main conclusions of this work are that distal femoral fractures can be treated correctly with the Condyle Plate, the LISS plate and the DFN. The stresses both in LISS and DFN implant are high especially around the screws. When respect to remodelling, the LISS produces an important resorption in the fractured region, while the other two implants do not strongly modify bone tissue microstructure.  相似文献   

13.
The main objective of this work is the evaluation, by means of the finite element method (FEM) of the mechanical stability and long-term microstructural modifications in bone induced to three different kinds of fractures of the distal femur by three types of implants: the Condyle Plate, the less invasive stabilization system plate (LISS) and the distal femur nail (DFN). The displacement and the stress distributions both in bone and implants and the internal bone remodelling process after fracture and fixation are obtained and analysed by computational simulation. The main conclusions of this work are that distal femoral fractures can be treated correctly with the Condyle Plate, the LISS plate and the DFN. The stresses both in LISS and DFN implant are high especially around the screws. When respect to remodelling, the LISS produces an important resorption in the fractured region, while the other two implants do not strongly modify bone tissue microstructure.  相似文献   

14.
The purpose of this study is to investigate the critical threshold stress causing bone resorption evaluated from strain measurement in vivo, comparing the various finite element models. In this study strains of miniplates used for mandibular fractures were measured once a week until the strains reduced. The maximum bite force for each patient was applied in the incisal, right molar and left molar region. The strains increased and reached a peak level at 2-4 weeks, whereas the bite forces increased during the period of measurements. A 3-D osteosynthesis model using finite element method showed that the compressive stresses of the bone surrounding screws ranged within approximately -40 MPa under the condition generating the same amounts of strains measured in the miniplates. Furthermore, various finite element models simulating mandibular reconstruction using the fibular graft were constructed. The models for reconstruction using single strut fibula showed distinct stress concentration in the cortical bone surrounding screws, and the peak stress levels were 2 to 3 times as strong as that of the fracture model. We conclude that critical threshold for bone resorption should be approximately -50 MPa (3600 micro strain).  相似文献   

15.
Dental implants may alter the mechanical environment in the jawbone, thereby causing remodelling and adaptation of the surrounding trabecular bone tissues. To improve the efficacy of dental implant systems, it is necessary to consider the effect of bone remodelling on the performance of the prosthetic systems. In this study, finite element simulations were implemented to predict the evolution of microarchitecture around four implant systems using a previously developed model that combines both adaptive and microdamage-based mechano-sensory mechanisms in bone remodelling process. Changes in the trabecular architecture around dental implants were mainly focused. The simulation results indicate that the orientational and ladder-like architecture around the implants predicted herein is in good agreement with those observed in animal experiments and clinical observations. The proposed algorithms were shown to be effective in simulating the remodelling process of trabecular architecture around dental implant systems. In addition, the architectural features around four typical dental implant systems in alveolar bone were evaluated comparatively.  相似文献   

16.
The aim of study was to evaluate the stress distribution in implant-supported prostheses and peri-implant bone using internal hexagon (IH) implants in the premaxillary area, varying surgical techniques (conventional, bicortical and bicortical in association with nasal floor elevation), and loading directions (0°, 30° and 60°) by three-dimensional (3D) finite element analysis. Three models were designed with Invesalius, Rhinoceros 3D and Solidworks software. Each model contained a bone block of the premaxillary area including an implant (IH, Ø4 × 10 mm) supporting a metal-ceramic crown. 178 N was applied in different inclinations (0°, 30°, 60°). The results were analyzed by von Mises, maximum principal stress, microstrain and displacement maps including ANOVA statistical test for some situations. Von Mises maps of implant, screws and abutment showed increase of stress concentration as increased loading inclination. Bicortical techniques showed reduction in implant apical area and in the head of fixation screws. Bicortical techniques showed slight increase stress in cortical bone in the maximum principal stress and microstrain maps under 60° loading. No differences in bone tissue regarding surgical techniques were observed. As conclusion, non-axial loads increased stress concentration in all maps. Bicortical techniques showed lower stress for implant and screw; however, there was slightly higher stress on cortical bone only under loads of higher inclinations (60°).  相似文献   

17.
Pedicle-screw-based motion preservation systems are often used to support a slightly degenerated disc. Such implants are intended to reduce intradiscal pressure and facet joints forces, while having a minimal effect on the motion patterns.In a probabilistic finite element study with subsequent sensitivity analysis, the effects of 10 input parameters, such as elastic modulus and diameter of the elastic rod, distraction of the segment, level of bridged segments, etc. on the output parameters intervertebral rotations, intradiscal pressures, and facet joint forces were determined. A validated finite element model of the lumbar spine was employed. Probabilistic studies were performed for seven loading cases: upright standing, flexion, extension, left and right lateral bending and left and right axial rotation.The simulations show that intervertebral rotation angles, intradiscal pressures and facet joint forces are in most cases reduced by a motion preservation system. The influence on intradiscal pressure is small, except in extension. For many input parameter combinations, the values for intervertebral rotations and facet joint forces are very low, which indicates that the implant is too stiff in these cases. The output parameters are affected most by the following input parameters: loading case, elastic modulus and diameter of the elastic rod, distraction of the segment, and angular rigidity of the connection between screws and rod.The designated functions of a motion preservation system can best be achieved when the longitudinal rod has a low stiffness, and when the connection between rod and pedicle screws is rigid.  相似文献   

18.
19.
Bone morphology and density changes are commonly observed following joint replacement, may contribute to the risks of implant loosening and periprosthetic fracture and reduce the available bone stock for revision surgery. This study was presented in the ‘Bone and Cartilage Mechanobiology across the scales’ WCCM symposium to review the development of remodelling prediction methods and to demonstrate simulation of adaptive bone remodelling around hip replacement femoral components, incorporating intrinsic (prosthesis) and extrinsic (activity and loading) factors. An iterative bone remodelling process was applied to finite element models of a femur implanted with a cementless total hip replacement (THR) and a hip resurfacing implant. Previously developed for a cemented THR implant, this modified process enabled the influence of pre- to post-operative changes in patient activity and joint loading to be evaluated. A control algorithm used identical pre- and post-operative conditions, and the predicted extents and temporal trends of remodelling were measured by generating virtual X-rays and DXA scans. The modified process improved qualitative and quantitative remodelling predictions for both the cementless THR and resurfacing implants, but demonstrated the sensitivity to DXA scan region definition and appropriate implant–bone position and sizing. Predicted remodelling in the intact femur in response to changed activity and loading demonstrated that in this simplified model, although the influence of the extrinsic effects were important, the mechanics of implantation were dominant. This study supports the application of predictive bone remodelling as one element in the range of physical and computational studies, which should be conducted in the preclinical evaluation of new prostheses.  相似文献   

20.
In a dental implant system, the value of stress and its distribution plays a pivotal role on the strength, durability and life of the implant–bone system. A typical implant consists of a Titanium core and a thin layer of biocompatible material such as the hydroxyapatite. This coating has a wide range of clinical applications in orthopedics and dentistry due to its biocompatibility and bioactivity characteristics. Low bonding strength and sudden variation of mechanical properties between the coating and the metallic layers are the main disadvantages of such common implants. To overcome these problems, a radial distributed functionally graded biomaterial (FGBM) was proposed in this paper and the effect of material property on the stress distribution around the dental implant–bone interface was studied. A three-dimensional finite element simulation was used to illustrate how the use of radial FGBM dental implant can reduce the maximum von Mises stress and, also the stress shielding effect in both the cortical and cancellous bones. The results, of course, give anybody an idea about optimized behaviors that can be achieved using such materials. The finite element solver was validated by familiar methods and the results were compared to previous works in the literature.  相似文献   