首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development of the resonance EEG responses of the left and right occipital areas was studied in right-handed men during prolonged (12 or 120 s) rhythmic, photostimulation with the intensity of 0.7 J and frequencies of 6, 10, and 16 Hz. Analysis of the EEG fine spectral structure was applied to compare the accumulated baseline EEG spectra and EEG spectra during photostimulation, to observe the dynamics of the short-term spectra and to detect power changes in the EEG narrow spectral band sharply coincident with the stimulation frequency. The more pronounced EEG responses to photostimulation were observed in subjects with the initially low EEG baseline, α-rhythm. Two-minute flash trains produced a substantial increase in the EEG power within the stimulation frequency with superposed oscillatory processes with different periods. These fluctuations are considered a reflection of intricate interaction between the adaptive and resonance EEG responses to the presented intermittent stimulation. Under 12-s stimulation the resonance EEG responses are steadily recorded within the first 3 s of stimulation and immediately after the flash cessation EEG power at the stimulation frequency returns to the initial level. The resonance EEG responses were more pronounced in the right hemisphere than in the left one, especially, at the stimulation frequencies of 6 and 16 Hz. With increasing the stimulation frequency, the maximum of resonance EEG responses was reached earlier. Under the stimulation frequency of 6 Hz, the maximal response was recorded 9–12 s after the beginning of flashes, at the frequencies of 10 and 16 Hz, it was recorded within 3–6 and 3 s, respectively.  相似文献   

2.
The photoinduced resonance EEG response in the occipital area (O1 and O2) of right-handed men during 12-s intermittent photic stimulation was studied as a function of flash frequency (6, 10, or 16 Hz) and intensity (5 levels from 0.05 to 0.7 J). The EEG power in the narrow band coinciding with stimulation frequency was FFT-extracted in 3-s intervals before, during, and after each stimulation. It was found that increase in flash intensity was accompanied by an enhancement of the resonance EEG response and decrease in time of reaching its maximal value. These changes were to a greater extent characteristic for the right hemisphere. The low-intensity stimulation induced more pronounced resonance effects in the left hemisphere, whereas the high-intensity flashes to a greater extent involved the right hemisphere. The asymmetry of the EEG response to stimulation of the middle intensity was slight, and the time of reaching the maximal level of the resonance activation was about 6-8 s. A relatively high level of the resonance EEG response was observed during stimulation with the frequency of 10 Hz, even in case of its minimal intensity. The most pronounced resonance EEG response was induced in the right occipital area by the high-intensity 16-Hz stimulation. The enhanced sensitivity of the right hemisphere to intensity of flashes is interpreted as an indication of interhemispheric differences in nonspecific adaptive mechanisms of the brain.  相似文献   

3.
A computerized system for precise stimulation and analysis of electroencephalographic (EEG) reactions to two simultaneously presented frequencies of sine-wave light (one constant, 13 Hz, and the other varying from 1 to 6 Hz and vice versa) was used to study the mechanisms of human brain reactivity to complex rhythmical stimulation. The frequencies were generated by computer and presented to the subjects by three different ways: as a result of their simple summation (additively), as a product of their multiplication (multiplicatively, amplitude modulation of constant frequency by the varying frequency), or by separate presentation to different eyes. The dynamics of electroencephalograms for different types of stimulation were compared. Under all three experimental conditions, the dynamics of EEG spectra has demonstrated the same general pattern of resonance activation, which was similar to that observed for the presented signals in the case of their amplitude modulation. Significant positive shifts in the functional state of subjects were observed as a result of stimulation. The results obtained show the leading role of the processes of amplitude modulation in the interaction of integrative, adaptive, and trace mechanisms of the brain functioning during human perception of complex rhythmical stimuli.  相似文献   

4.
Activity of the neurones with stable theta-bursts was recorded extracellularly in intact and hippocampectomized septum of unanaesthetized chronic rabbits during low-frequency (3-17 Hz) stimulation of horizontal limb of the diagonal band or the lateral septal nucleus. Gradual entrainment and phase-locking of the spontaneous theta-cycles occurred. Two types of entrainment were observed: "entrainment by pause", where interburst interval was reset by the stimuli; and "entrainment by burst", where bursts were time-locked to the stimuli. Such reorganization of the spontaneous bursts occurred in a narrow frequency range of stimulation (from 4 Hz up to 9-12 Hz), with the best resonance following in the range of "basic" theta frequencies of the awake rabbit (5-6 Hz). With stimulation beyond the theta-range three phenomena occurred: shift of the burst frequencies to higher or lower harmonics of stimulation frequencies; complex interactions of basic background frequency with the rhythm of stimulation ("beating"); escape from the influence of the stimuli with return to background theta-burst frequency.  相似文献   

5.
Brain resonance phenomena and induced rhythms in the brain recently gained importance in electroencephalographic, magnetoencephalographic and cellular studies (Ba\c sar and Bullock 1992). It was hypothesized that evoked potentials are superpositions of induced rhythms caused by resonance phenomena in neural populations (Ba\c sar et al. 1992). According to Ba\c sar (1972), such resonance phenomena are reflected in the main peaks of the amplitude frequency characteristics computed from EEG responses. The present study is based on a frequency domain approach for the evaluation of topography- and modality-dependent properties of oscillatory brain responses. EEG and evoked potentials were recorded from vertex, parietal and occipital scalp locations in 24 volunteers. Two combined methods were applied: (1) amplitude frequency characteristics were computed from the transient evoked responses, and (2) frequency components of the transient responses were obtained by adaptive digital filtering. Our main goal was to investigate theta (4--7 Hz) and alpha (8--15 Hz) response components. (1) Amplitude frequency characteristics. Auditory stimuli elicited theta-alpha compound responses in the 4--11 Hz frequency band (e.g. typical peaking frequency around 7 Hz for vertex recordings). Visual stimuli elicited alpha responses (e.g. typical peaking frequency for vertex recordings around 9--12 Hz). Frequency maxima for visual stimuli thus had main peaks at higher frequency values than frequency maxima for auditory stimuli. (2) Digital filtering confirmed these results: for vertex recordings, theta vs. alpha response amplitudes were 9 vs 6 for auditory stimuli and 5 vs 5 for visual stimuli, thus confirming a shift towards higher frequencies, i.e. a more prominent contribution of the alpha range, in the case of visual stimulation. We hypothesize that these properties might reflect site- and modality-specific features of stimulus encoding in the brain in which resonance properties of neuron populations are involved. Furthermore we emphasize the utility of the systems theory approach for a better understanding of brain function by means of EPs. Received: 25 February 1994 / Accepted in revised form: 5 August 1994  相似文献   

6.
Agnisara is a Hathayogic exercise consisting essentially in alternate, forceful retractions and protrusions of the abdominal wall, performed along a 20-30 s period of apnoea. In the course of series of Agnisars spindle bursts of a "wicket" EEG wave pattern developed over the para-Rolandic areas of the cerebral cortex, at frequencies around 12-13 Hz, with waxing and waning amplitudes in the range of 50 to 100 microV. These spindle-bursts, which occurred preferably during the phase of retraction of the abdominal wall, were named "Xi" rhythm (after the Greek letter X). It is the same as the one that regularly accompanies the performance on various other Hathayogic exercises. Xi spindles were recorded in linked earlobe reference derivations from areas located bilaterally midway between F-C, C-P, and P-O standard electrode positions of the 10-20 system. This EEG pattern would be considered as the expression of the central excitation, produced by the exercise's long-lasting and repeated stimulation of visceral, and somatic receptors. Thus, this activation affects mainly cortical structures with somato-visceral representation.  相似文献   

7.
1. In order to determine the variable distributions of 5 activation dependent EEG activity patterns occurring during visual information processing, mean values and standard deviations of the percental quantities of the frequencies 4, 5, ..., 13 Hz, 14 to 20 Hz and 21 to 30 Hz, as well as the mean amplitudes in the frequency bands 3.5 ... 7.4 Hz, 7.5 ... 13.4 Hz and 13.5 to 30 Hz were determined on corresponding to 10 s samples. It could be demonstrated by regression analysis that an interval scale level can be assumed already on the basis of cethe percental quantities in the three last mentioned frequency bands. 2. On the basis of 18 relevant variables, all the adjacent activity patterns could be separated from each other by means of univariate variance analysis at pairwise mean value comparison by at least two variables. 3. After stepwise reduction of dispensable variables in the framework of a linear discriminance analysis an optimal set of variables was determined, comprising the percental quantities of the frequencies 4, 5, 6, 10, 12 Hz, and 14 to 20 Hz, as well as the mean value of the amplitudes in the frequency band 3.5 to 7.4 Hz. In 4 our of 5 elementary discriminance functions, the mean values calculated for each pattern were significantly distinguishable from each other (analysis of variance, Newman-Keuls test). 4. By linear regression analysis it could be shown that the classification system of the EEG activity patterns at visual information processing can be mapped on an interval scale after the reduction of variables, too. Finally, data about the reliability of the scoring procedure are presented.  相似文献   

8.
Repetitive activation of a skeletal muscle results in potentiation of the twitch contractile response. Incompletely fused tetanic contractions similar to those evoked by voluntary activation may also be potentiated by prior activity. We aimed to investigate the role of stimulation frequency on the enhancement of unfused isometric contractions in rat medial gastrocnemius muscles in situ. Muscles set at optimal length were stimulated via the sciatic nerve with 50-micros duration supramaximal pulses. Trials consisted of 8 s of repetitive trains [5 pulses (quintuplets) 2 times per second or 2 pulses (doublets) 5 times per second] at 20, 40, 50, 60, 70, and 80 Hz. These stimulation frequencies represent a range over which voluntary activation would be expected to occur. When the frequency of stimulation was 20, 50, or 70 Hz, the peak active force (highest tension during a contraction - rest tension) of doublet contractions increased from 2.2 +/- 0.2, 4.1 +/- 0.4, and 4.3 +/- 0.5 to 3.1 +/- 0.3, 5.6 +/- 0.4, and 6.1 +/- 0.7 N, respectively. Corresponding measurements for quintuplet contractions increased from 2.2 +/- 0.2, 6.1 +/- 0.5, and 8.7 +/- 0.7 to 3.2 +/- 0.3, 7.3 +/- 0.6, and 9.0 +/- 0.7 N, respectively. Initial peak active force values were 27 +/- 1 and 61.5 +/- 5% of the maximal (tetanic) force for doublet and quintuplet contractions, respectively, at 80 Hz. With doublets, peak active force increased at all stimulation frequencies. With quintuplets, peak active force increased significantly for frequencies up to 60 Hz. Twitch enhancement at the end of the 8 s of repetitive stimulation was the same regardless of the pattern of stimulation during the 8 s, and twitch peak active force returned to prestimulation values by 5 min. These experiments confirm that activity-dependent potentiation is evident during repeated, incompletely fused tetanic contractions over a broad range of frequencies. This observation suggests that, during voluntary motor unit recruitment, derecruitment or decreased firing frequency would be necessary to achieve a fixed (submaximal) target force during repeated isometric contractions over this time period.  相似文献   

9.
We have shown that 50 Hz sinusoidal magnetic fields within the 5-10 micro Tesla (μT) rms range cause an intensity-dependent reduction in nerve growth factor (NGF) stimulation of neurite outgrowth (NO) in PC-12 cells. Here we report on the frequency dependence of this response over the 15-70 Hz range at 5 Hz intervals. Primed PC-12 cells were plated in collagen-coated, 60 mm plastic petri dishes with or without 5 ng/ml NGF and were exposed to sinusoidal magnetic fields for 22 h in a CO2 incubator at 37 °C. One 1,000-turn coil, 20 cm in diameter, generated vertically oriented magnetic fields. The dishes were stacked on the center axis of the coil to provide a range of intensities between 3.5 and 9.0 μT rms. The flux density of the ambient DC magnetic field was 37 μT vertical and 19 μT horizontal. The assay consisted of counting over 100 cells in the central portion (radius ≤0.3 cm) of each dish and scoring cells positive for NO. Sham exposure of cells treated identically with NGF demonstrated no difference in the percentage of cells with NO between exposed and magnetically shielded locations within the incubator. Analysis of variance demonstrated flux density-dependent reductions in NGF-stimulated NO over the 35-70 Hz frequency range, whereas frequencies between 15 Hz and 30 Hz produced no obvious reduction. The results also demonstrated a relative maximal sensitivity of cells at 40 Hz with a possible additional sensitivity region at or above 70 Hz. These findings suggest a biological influence of perpendicular AC/DC magnetic fields different from those identified by the ion parametric resonance model, which uses strictly parallel AC/DC fields. © 1995 Wiley-Liss, Inc.  相似文献   

10.
This article concerns one of the most important problems of brain-computer interfaces (BCI) based on Steady State Visual Evoked Potentials (SSVEP), that is the selection of the a-priori most suitable frequencies for stimulation. Previous works related to this problem were done either with measuring systems that have little in common with actual BCI systems (e.g., single flashing LED) or were presented on a small number of subjects, or the tested frequency range did not cover a broad spectrum. Their results indicate a strong SSVEP response around 10 Hz, in the range 13–25 Hz, and at high frequencies in the band of 40–60 Hz. In the case of BCI interfaces, stimulation with frequencies from various ranges are used. The frequencies are often adapted for each user separately. The selection of these frequencies, however, was not yet justified in quantitative group-level study with proper statistical account for inter-subject variability. The aim of this study is to determine the SSVEP response curve, that is, the magnitude of the evoked signal as a function of frequency. The SSVEP response was induced in conditions as close as possible to the actual BCI system, using a wide range of frequencies (5–30 Hz, in step of 1 Hz). The data were obtained for 10 subjects. SSVEP curves for individual subjects and the population curve was determined. Statistical analysis were conducted both on the level of individual subjects and for the group. The main result of the study is the identification of the optimal range of frequencies, which is 12–18 Hz, for the registration of SSVEP phenomena. The applied criterion of optimality was: to find the largest contiguous range of frequencies yielding the strong and constant-level SSVEP response.  相似文献   

11.
Three identified interneurons of the cercal system were investigated electrophysiologically; these interneurons are sensitive only to stimulation of cercal filiform-hair sensilla by low-frequency sound. Measurement of the frequency ranges revealed cut-off frequencies between ca. 20 and 70 Hz. Analysis of the responses near threshold and at higher intensities in the frequency range 5–500 Hz shows that one of them (Interneuron 9-1b) exhibits a sensitivity maximum at the frequency-intensity combination necessary for the perception of an intraspecific signal at 30 Hz. This band-pass behavior disappears at higher stimulus intensities. In order to investigate the mechanism of the low-frequency selectivity of the interneurons, two-tone stimulation experiments were performed. When stimuli in the best-frequency range were superimposed by a 100-Hz tone, the spiking activity was suppressed in an intensity-dependent manner. Accepted: 22 July 1998  相似文献   

12.
In urethan-anesthetized cats, frequency domain analysis was used to explore the mechanisms of differential responses of inferior cardiac (CN), vertebral (VN), and renal (RN) sympathetic nerves to electrical stimulation of a discrete region of the medullary raphe (0-2 mm caudal to the obex). Raphe stimulation in baroreceptor-denervated cats at frequencies (7-12 Hz) that entrained the 10-Hz rhythm in nerve activity decreased CN and RN activities but increased VN activity. The reductions in CN and RN discharges were associated with decreased low-frequency (相似文献   

13.
Two sinusoidal signals, one with a constant frequency of 13 Hz and the other with a frequency continuously changing from 1 to 6 Hz and back, were presented simultaneously to subjects through spectacles with light-emitting diodes either to both eyes as a product (amplitude modulation of a constant frequency by a variable one) or to each eye separately. Both kinds of variable frequency exposure revealed a rhomboid pattern of the resonance activation of the EEG spectrum, similar to the spectral dynamics of a signal subject to amplitude modulation. This testifies to the key role of EEG amplitude modulation in the responses of the nervous system to variable frequency rhythmic stimuli. Both types of photic stimulation led to a substantial increase in EEG spectral density and improved the subjects' self-rating of the overall state of well-being, activity, and mood. In addition, separate stimulation of each eye led to an improvement in the anxiety and exercise performance indices (the Luscher color test) and a significant correlation between the intensity of EEG responses and changes in the general state. These differences are explained in terms of the involvement of the interhemispheric interaction mechanisms in the processing of complex rhythmic signals by the brain.  相似文献   

14.
Experiments were carried out on the working right ventricular myocardium of adult cats, guinea-pigs and rabbits. Membrane voltage was recorded by the glass microelectrode technique and the preparations were stimulated with frequencies of 5, 1 and 0.2 Hz. After a steady state had been reached, a pause (TP) lasting 10-600 s was interpolated. The influence of TP on the duration (D) of post-rest action potentials (AP) was studied; the effect of the pause was measured at electric zero level (D0) and at further repolarization levels (-20, -40 and -60 mV, given here as D-20, D-40 and D-60). At 1 and 0.2 Hz frequency, the cat myocardium displayed lengthening of the AP proportional to the duration of the pause; at 5 Hz frequency, D0 reacted by lengthening up to TP = 120 s and to further pauses by slight shortening. D-60, at all frequencies, lengthened throughout the whole of the given TP range. The rabbit myocardium, at all the given frequencies, reacted up to TP = 60-120 s by marked shortening of post-rest AP at all repolarization levels; with longer pauses the AP lengthened. At 5 Hz frequency the guinea-pig myocardium reacted similarly to the cat myocardium; at the lower stimulation frequencies, the pause-induced changes in the post-rest AP were less strongly expressed. In all the given types of myocardium, the most pronounced post-rest AP reactions were those at electric zero level (the plateau phase of the AP); towards more negative repolarization values and with lower pre-pause stimulation frequencies they were less strongly expressed.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
Previous studies have shown that neurons within the vestibular nuclei (VN) can faithfully encode the time course of sensory input through changes in firing rate in vivo. However, studies performed in vitro have shown that these same VN neurons often display nonlinear synchronization (i.e. phase locking) in their spiking activity to the local maxima of sensory input, thereby severely limiting their capacity for faithful encoding of said input through changes in firing rate. We investigated this apparent discrepancy by studying the effects of in vivo conditions on VN neuron activity in vitro using a simple, physiologically based, model of cellular dynamics. We found that membrane potential oscillations were evoked both in response to step and zap current injection for a wide range of channel conductance values. These oscillations gave rise to a resonance in the spiking activity that causes synchronization to sinusoidal current injection at frequencies below 25 Hz. We hypothesized that the apparent discrepancy between VN response dynamics measured in in vitro conditions (i.e., consistent with our modeling results) and the dynamics measured in vivo conditions could be explained by an increase in trial-to-trial variability under in vivo vs. in vitro conditions. Accordingly, we mimicked more physiologically realistic conditions in our model by introducing a noise current to match the levels of resting discharge variability seen in vivo as quantified by the coefficient of variation (CV). While low noise intensities corresponding to CV values in the range 0.04-0.24 only eliminated synchronization for low (<8 Hz) frequency stimulation but not high (>12 Hz) frequency stimulation, higher noise intensities corresponding to CV values in the range 0.5-0.7 almost completely eliminated synchronization for all frequencies. Our results thus predict that, under natural (i.e. in vivo) conditions, the vestibular system uses increased variability to promote fidelity of encoding by single neurons. This prediction can be tested experimentally in vitro.  相似文献   

16.
Neuromuscular electrical stimulation can generate contractions through peripheral and central mechanisms. Direct activation of motor axons (peripheral mechanism) recruits motor units in an unnatural order, with fatigable muscle fibers often activated early in contractions. The activation of sensory axons can produce contractions through a central mechanism, providing excitatory synaptic input to spinal neurons that recruit motor units in the natural order. Presently, we quantified the effect of stimulation frequency (10-100 Hz), duration (0.25-2 s of high-frequency bursts, or 20 s of constant-frequency stimulation), and intensity [1-5% maximal voluntary contraction (MVC) torque generated by a brief 100-Hz train] on the torque generated centrally. Electrical stimulation (1-ms pulses) was delivered over the triceps surae in eight subjects, and plantar flexion torque was recorded. Stimulation frequency, duration, and intensity all influenced the magnitude of the central contribution to torque. Central torque did not develop at frequencies < or = 20 Hz, and it was maximal at frequencies > or = 80 Hz. Increasing the duration of high-frequency stimulation increased the central contribution to torque, as central torque developed over 11 s. Central torque was greatest at a relatively low contraction intensity. The largest amount of central torque was produced by a 20-s, 100-Hz train (10.7 +/- 5.5 %MVC) and by repeated 2-s bursts of 80- or 100-Hz stimulation (9.2 +/- 4.8 and 10.2 +/- 8.1% MVC, respectively). Therefore, central torque was maximized by applying high-frequency, long-duration stimulation while avoiding antidromic block by stimulating at a relatively low intensity. If, as hypothesized, the central mechanism primarily activates fatigue-resistant muscle fibers, generating muscle contractions through this pathway may improve rehabilitation applications.  相似文献   

17.
To determine the skeletal muscle stimulation parameters that are most important in establishing vasodilation in the microvasculature, I tested whether arteriolar diameter during 2 min of repetitive, short-duration, tetanic skeletal muscle contractions increased with changes in stimulus frequency, stimulation train duration, and contraction frequency. To test this, the diameter of transverse arterioles approximately perpendicular to small bundles of cremaster muscle fibers in situ of anesthetized Golden Syrian hamsters was used as a bioassay system. Arteriolar diameter was measured before and during different stimulation patterns that consisted of a contraction frequency [6, 12, or 24 contractions per minute (cpm)], a stimulation train duration (250, 500, or 750 ms) and a stimulus frequency (4, 8, 10, 15, 20, 30, 40, 60, and 80 Hz). The magnitude of the dilation significantly increased with stimulus frequency but not in a simple linear manner. The average rate of increase was 0.32 +/- 0.02 microm/Hz from 4 to 20 Hz and 0.09 +/- 0.02 microm/Hz from 30 to 80 Hz. The magnitude of the dilation increased significantly with the contraction frequency where the dilation at 6 cpm was significantly smaller than the dilation at 24 cpm across all stimulus frequencies. Changing the train duration from 250 to 750 ms did not significantly affect the magnitude of the dilation. These observations suggest that stimulation parameters are important in determining the magnitude of the microvascular dilation and that the magnitude of the dilation was dependent on both the contraction frequency and stimulus frequency but was independent of train duration.  相似文献   

18.
We previously reported the development of a force- and fatigue-model system that predicted accurately forces during repetitive fatiguing activation of human skeletal muscles using brief duration (six-pulse) stimulation trains. The model system was tested in the present study using force responses produced by longer duration stimulation trains, containing up to 50 pulses. Our results showed that our model successfully predicted the peak forces produced when the muscle was repetitively activated with stimulation trains of frequencies ranging from 20 to 40 Hz, train durations ranging from 0.5 to 1 s, and varied pulse patterns. The predicted peak forces throughout each protocol matched the experimental peak forces with r2 values above 0.9 and predicted successfully the forces at the end of each protocol with <15% error for all protocols tested. The success of our model system further supports its potential use for the design of optimal stimulation patterns for individual users during functional electrical stimulation.  相似文献   

19.
Noisy galvanic vestibular stimulation has been associated with numerous cognitive and behavioural effects, such as enhancement of visual memory in healthy individuals, improvement of visual deficits in stroke patients, as well as possibly improvement of motor function in Parkinson’s disease; yet, the mechanism of action is unclear. Since Parkinson’s and other neuropsychiatric diseases are characterized by maladaptive dynamics of brain rhythms, we investigated whether noisy galvanic vestibular stimulation was associated with measurable changes in EEG oscillatory rhythms within theta (4–7.5 Hz), low alpha (8–10 Hz), high alpha (10.5–12 Hz), beta (13–30 Hz) and gamma (31–50 Hz) bands. We recorded the EEG while simultaneously delivering noisy bilateral, bipolar stimulation at varying intensities of imperceptible currents – at 10, 26, 42, 58, 74 and 90% of sensory threshold – to ten neurologically healthy subjects. Using standard spectral analysis, we investigated the transient aftereffects of noisy stimulation on rhythms. Subsequently, using robust artifact rejection techniques and the Least Absolute Shrinkage Selection Operator regression and cross-validation, we assessed the combinations of channels and power spectral features within each EEG frequency band that were linearly related with stimulus intensity. We show that noisy galvanic vestibular stimulation predominantly leads to a mild suppression of gamma power in lateral regions immediately after stimulation, followed by delayed increase in beta and gamma power in frontal regions approximately 20–25 s after stimulation ceased. Ongoing changes in the power of each oscillatory band throughout frontal, central/parietal, occipital and bilateral electrodes predicted the intensity of galvanic vestibular stimulation in a stimulus-dependent manner, demonstrating linear effects of stimulation on brain rhythms. We propose that modulation of neural oscillations is a potential mechanism for the previously-described cognitive and motor effects of vestibular stimulation, and noisy galvanic vestibular stimulation may provide an additional non-invasive means for neuromodulation of functional brain networks.  相似文献   

20.
Electrical stimulation (1-ms pulses, 100 Hz) produces more torque than expected from motor axon activation (extra contractions). This experiment investigates the most effective method of delivering this stimulation for neuromuscular electrical stimulation. Surface stimulation (1-ms pulses; 20 Hz for 2 s, 100 Hz for 2 s, 20 Hz for 3 s) was delivered to triceps surae and wrist flexors (muscle stimulation) and to median and tibial nerves (nerve stimulation) at two intensities. Contractions were evaluated for amplitude, consistency, and stability. Surface electromyograph was collected to assess how H-reflexes and M-waves contribute. In the triceps surae, muscle stimulation produced the largest absolute contractions (23% maximal voluntary contraction), evoked the largest extra contractions as torque increased by 412% after the 100-Hz stimulation, and was more consistent and stable compared with tibial nerve stimulation. Absolute and extra contraction amplitude, consistency, and stability of evoked wrist flexor torques were similar between stimulation types: torques reached 11% maximal voluntary contraction, and extra contractions increased torque by 161%. Extra contractions were 10 times larger in plantar flexors compared with wrist flexors with muscle stimulation but were similar with nerve stimulation. For triceps surae, H reflexes were 3.4 times larger than M waves during nerve stimulation, yet M waves were 15 times larger than H reflexes during muscle stimulation. M waves in the wrist flexors were larger than H reflexes during nerve (8.5 times) and muscle (18.5 times) stimulation. This is an initial step toward utilizing extra contractions for neuromuscular electrical stimulation and the first to demonstrate their presence in the wrist flexors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号