首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fast and robust liquid chromatography-mass spectrometry (LC-MS-MS) method has been developed for simultaneous quantitation of the angiotensin-converting enzyme (ACE) inhibitor, ramipril and its metabolite ramiprilat in human plasma. The method involves a solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables a detection limit at sub-nanogram levels. The proposed method has been validated with a linear range of 0.5-250 ng/ml for both ramipril and ramiprilat. The overall recoveries for ramipril and ramiprilat were 88.7 and 101.8%, respectively.  相似文献   

2.
This paper describes a simple, fast and sensitive liquid chromatography-mass spectrometry method for quantification of an anti-thrombocythemic agent, anagrelide in human plasma. The samples were subjected to a liquid-liquid extraction after addition of a buffer and an internal standard. Chromatography was performed on an Inertsil ODS2 column and the extract was injected onto a HPLC system coupled with mass spectrometric detection. Linear responses for standards were observed from 50 to 7500 pg/ml. The accuracy of intra-assay and inter-assay were in the ranges 4.3-4.4% and 4.8-5.6%, respectively. The method is simple and reproducible with a run time of less than 2 min.  相似文献   

3.
A rapid and specific liquid chromatographic mass spectrometric (LC-MS-MS) method has been developed for the determination of paroxetine in human plasma. The procedure involves a liquid-liquid extraction of paroxetine and fluoxetine (internal standard) with cyclohexane-ethyl acetate. The standard curve was linear over a working range of 0.2-50 ng/ml. The lower limit of quantitation was 0.2 ng/ml. No endogenous compounds were found to interfere with the analysis. The absolute recovery was 70.8% for paroxetine and 84.1% for the internal standard. The accuracy of inter-assay and intra-assay accuracy was in the ranges -4.8 to -0.5% and -3.4 to 4.8%, respectively. This method proved to be suitable for bioequivalence studies by being simple, selective and reproducible.  相似文献   

4.
A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were 相似文献   

5.
A specific liquid chromatography-mass spectrometric (LC-MS/MS) assay was developed and validated for the determination of lercanidipine, a dihydropyridine calcium channel blocker, in human plasma. Lercanidipine R-D3 was used as internal standard (IS). The drug was extracted from plasma using liquid-liquid extraction technique utilizing hexane: ethyl acetate as extraction solvent. The samples were analyzed using a prepacked Thermo Hypersil C(8) column and a mobile phase composed of a mixture of aqueous acetic acid and triethylamine in methanol. An ion trap mass spectrometer equipped with electrospray ionization (ESI) source operating in the positive ion mode was used to develop and validate the method. The method was proved to be sensitive and specific by testing six different human plasma batches. Linearity was established for the concentration ranges of 0.1-16 ng/ml with a regression factor of 0.9996. The lower limit of quantitation was identifiable and reproducible at 0.1 ng/ml with a precision of 7.2%.  相似文献   

6.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

7.
A new method for the determination of tranexamic acid (TA) in human plasma using high performance liquid chromatography with tandem mass spectrometric detection was described. TA and the internal standard, methyldopa, was extracted from a 200 l plasma sample by a one-step deproteination using perchloric acid. Chromatographic separation was performed on an Xtrra MS C18 Column (2.1 mm x 100 mm, 3.5 microm) with the mobile phase consisting of 10% acetonitrile in 2 mM ammonium acetate buffer (pH 3.5) at a flow rate of 0.15 ml/min. The total run time was 5 min for each sample. Detection and quantitation was performed by the mass spectrometer using the multiple reaction monitoring of the precursor-product ion pair m/z 158 --> 95 for TA and m/z 212 --> 166 for methyldopa, respectively. The method was linear over the concentration range of 0.02-10.00 g/ml with lower limit of quantification of 0.02 microg/ml for TA. The intra- and inter-day precision was less than 11% and accuracy ranged -10.88 to 11.35% at the TA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of TA in 12 healthy subjects.  相似文献   

8.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

9.
A convenient liquid chromatographic-single quadrupole mass spectrometric (LC-MS) method was developed and validated for the determination of chlorpheniramine maleate (INN name: chlorphenamine) in human plasma. The method had advantages of a single liquid-liquid extraction with diethylether and high sensitivity. The linearity was also excellent over the concentration range of 0.52-20.8 ng/ml of chlorpheniramine maleate. The intra- and inter-day precision and accuracy ranged between 0.0 and 13.9%, showing a good reproducibility. This developed method was successfully applied to analysis of chlorpheniramine maleate in clinical studies.  相似文献   

10.
A reversed-phase high-performance liquid chromatography method with electrospray ionization and mass spectral detection is described for the determination of capecitabine, 5'-deoxy-5-fluorocytidine and 5'-deoxy-5-fluorouridine in human plasma with 5-chloro-2'-deoxyuridine as the internal standard. An on-line sample clean-up procedure allows dilution of the plasma sample with the initial mobile phase. The linear dynamic range is 0.0500-10.0 microgram/ml for capecitabine, and 0.0500-25.0 microgram/ml for the metabolites, 5'-deoxy-5-fluorocytidine and 5'-deoxy-5-fluorouridine, respectively. This method has been used to analyze plasma samples from patients receiving capecitabine in combination with oxaliplatin.  相似文献   

11.
A robust, accurate and sensitive high-performance liquid chromatographic method for the determination of rosiglitazone (I) in human plasma has been developed. Pioglitazone (II) was used as internal standard. Both I and II are extracted from plasma using a liquid-liquid extraction procedure. Isocratic separation of I and II is carried out using a reversed-phase Zorbax SB C(18), 15-cm column with mobile phase consisting of methanol and a mixed phosphate buffer (10 mM monobasic sodium phosphate and dibasic sodium phosphate, pH adjusted to 2.6 with ortho-phosphoric acid) in the ratio 30:70 (v/v) and quantified by UV detection at 245 nm. Linearity was established over the range 5-1250 ng/ml using 1 ml human plasma. The method is specific, the endogenous components in plasma do not interfere with I and II. C.V. (%) of intra-day samples is less than 5.0% at four concentrations tested namely 5, 10, 500 and 1000 ng/ml. Similarly, over the same nominal concentrations, the precision of inter-day (5 days) samples also results in C.V. (%) less than 5.0%. The recoveries of I and II from human plasma were about 79 and 60%, respectively. This method can be used for routine clinical monitoring of I.  相似文献   

12.
A simple high-performance liquid chromatographic method for determination of ticlopidine in human plasma using ultra violet detection was developed. The separation of the investigated compound and internal standard was achieved on a C18 BD column with a 0.01 M potassium dihydrogen phosphate buffer (pH 4)–acetonitrile–methanol (20:40:40, v/v) mobile phase. The detection was performed at 215 nm. The compounds were isolated from plasma by Bond Elut C18 solid-phase extraction, the mean absolute recovery was 84.9%. The limit of quantitation was 10 ng ml−1, the limit of detection was 5 ng ml−1. The bioanalytical method was validated with respect to linearity, within- and between-day accuracy and precision, system suitability and stability. All validated parameters were found to be within the internationally required limits. The developed analytical method for ticlopidine was found to be suitable for application in pharmacokinetic studies and human drug monitoring.  相似文献   

13.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection has been developed for the determination of rizatriptan in human plasma. Following a single-step liquid-liquid extraction with methyl tertiarybutyl ether, the analytes were separated using a mobile phase consisting of 0.05% (v/v) triethylamine in water (adjusting to pH 2.75 with 85% phosphoric acid) and acetonitrile (92:8, v/v). Fluorescence detection was performed at an excitation wavelength of 225nm and an emission wavelength of 360nm. The linearity for rizatriptan was within the concentration range of 0.5-50ng/ml. The intra- and inter-day precisions of the method were not more than 8.0%. The lower limit of quantification (LLOQ) was 0.5ng/ml for rizatriptan. The method was sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

14.
Alkylresorcinols (ARs) are phenolic lipids that among foods are found almost exclusively in whole grain and bran products based on wheat and rye. They have been suggested to be used as selective biomarkers of whole grain wheat and rye intake and, thus, may serve as an alternative/complement to commonly used dietary assessment methods in epidemiological studies. For such investigations where analysis of large numbers of valuable samples is required, rapid, sensitive, and repeatable methods are essential. In this article, we describe a rapid and sensitive gas chromatography-mass spectrometry (GC-MS) method for quantification of AR homologues C17:0, C19:0, C21:0, C23:0, and C25:0 in human plasma. The method uses Oasis MAX solid phase extraction cartridges for sample cleanup. A plasma sample of 0.2 ml could be used without preincubation with water. Samples in the range of 7 to 8750 nmol total AR/L were successfully analyzed with the method described, and the average total AR recovery within the reported range was 92 ± 12%. The within- and between-day precision values of total AR concentration in a quality control sample, determined as the coefficients of variation, were on average 7 and 10%, respectively. Approximately 30 to 50 samples could be analyzed within 1 day. The improved GC-MS method presented can be used for rapid analysis of ARs in relatively small sample volumes.  相似文献   

15.
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the quantification of metacavir in rat plasma using tinidazole as an internal standard (I.S.). Following ethyl acetate extraction, the analytes were separated on a Shim-pack ODS (4.6 microm, 150 mm x 2.0 mm I.D.) column and analyzed in selected ion monitoring (SIM) mode with a positive ESI interface using the respective [M+H](+) ions, 266 for metacavir and 248 for tinidazole. The method was validated over the concentration range of 1-600 ng/mL for metacavir. Between and within-batch precisions (R.S.D.%) were all within 15% and accuracy (%) ranged from 92.2 to 105.8%. The lower limit of quantification (LLOQ) was 1 ng/mL. The extraction recovery was on average 89.8%. The validated method was used for the pharmacokinetic study of metacavir in rats.  相似文献   

16.
A rapid gas chromatography-mass spectrometric method for the determination of nalmefene in human plasma is described. The procedure involves protein precipitation, extraction with ethanol-chloroform mixture and derivatization with pentafluropropionic anhydride. The deuterated analog of nalmefene, 6beta-naltrexol-d(7), was used as the internal standard. Quantitation was achieved on a HP-1 column (12 mx0.2 mm I.D.) with negative chemical ionization (NCI) using methane:ammonia (95:5) as the reagent gas. The standard curves were fitted using a quadratic equation with the curve encompassing a range of 0.5 to 200 ng/ml, and the intra- and inter-assay variations for three different nalmefene levels were less than 10% throughout. The limit of quantitation was found to be 0.5 ng/ml. The method described is highly specific and reproducible, and could also be applied for the determination of naltrexone and 6beta-naltrexol. Application of the method to actual human plasma samples is demonstrated.  相似文献   

17.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.  相似文献   

18.
A method for the determination of sertraline in human plasma using gas chromatography-mass spectrometry (GC-MS), with the selected ion-monitoring (SIM) mode, was described. The following was used in this study: (1) single liquid-liquid extraction at alkaline pH after deproteinization of plasma protein and (2) perfluoroacylation with HFBA, which has higher sensitivity (about 10-fold) compared with previous reported derivatization. The detection limit for the SIM of sertraline as an N-HFB derivative was 0.1 ng/ml, and its recovery was 80-85%. The linear response was obtained in the range of 0.2-10.0 ng/ml with a correlation coefficient of 0.999. The coefficient of variation (C.V.%) was less than 12.1% in the 1-30 ng/ml, and less than 18.2% at 0.2 ng/ml, and the accuracy was less than 10% at all of the concentration range. These findings indicate that this assay method has adequate precision and accuracy to determine the amount of sertraline in human plasma. After pharmacokinetics was performed with this assay method following oral administration of sertraline hydrochloride in man, moment analysis revealed that pharmacokinetic parameters for sertraline (Cmax, 10.3 ng/ml; Tmax, 8.0 h; T(1/2) 28.6 h) were similar to previously reported results. These results indicate that this simple and sensitive assay method is readily applicable to the pharmacokinetic studies of sertraline.  相似文献   

19.
The modification of the lysine moieties of proteins to Nepsilon-carboxymethyllysine (CML) is supposed to play a major role in the development of long-term complications in patients with diabetes mellitus. This paper presents an analytical method for the quantitative determination of CML in plasma proteins, which could be used for studying the development of diabetic complications. The method is based on isolating proteins from plasma by precipitation with trichloroacetic acid and hydrolysing these under acidic conditions (6M hydrochloric acid at 110 degrees C for 20 h) to the individual amino acids. After hydrolysis, CML is derivatised along with the other amino acids to 9-fluorenylmethoxycarbonyl (FMOC) derivatives, which are subsequently separated by reversed-phase column liquid chromatography using a 150 mm x 4.6 mm C8 column and a mobile phase of 25 mM potassium phosphate buffer (pH 2.0) and acetonitrile (80:20 (v/v)) and detected using fluorescence detection (excitation at 260 nm and emission at 310 nm). Quantification of the protein-bound CML content of a plasma sample is achieved using standard addition. The impact of several aspects of the sample preparation and chromatography on method performance is discussed. Method evaluation results are reported and show that this method is capable of determining CML with good accuracy and precision (below 10%) in the relevant concentration range (1-10 microg/ml), with a limit of detection of 0.2 microg/ml.  相似文献   

20.
A method is proposed for the determination of nicotine and cotinine in human urine, plasma and saliva. Nicotine and cotinine were extracted from alkalinized sample with ethyl ether and concentrated to minimum volume with nitrogen stream. The volatility of nicotine was prevented by the addition of acetic acid to the organic solvent during evaporation. Peak shapes and quantitation of nicotine and cotinine are excellent, with linear calibration curves over a wide range of 1-10,000 ng/ml. The detection limits of nicotine and cotinine are 0.2 ng/ml in urine and 1.0 ng/ml in plasma and saliva. The intra-day precision of nicotine and cotinine in all samples was <5% relative standard deviation (RSD). Urine, plasma and saliva samples of 303 non-smoking and 41 smoking volunteers from a girl's high school in Korea were quantified by the described procedure. As a result, the concentrations of nicotine and cotinine in plasma ranged from 6 to 498 ng/ml and 4 to 96 ng/ml. Otherwise, those of nicotine and cotinine in saliva ranged from 0 to 207 ng/ml and 0 to 42 ng/ml, and those of nicotine and cotinine in urine ranged from 0 to 1,590 ng/ml and 0 to 2,986 ng/ml, respectively. We found that the concentration of cotinine in plasma was successfully predicted from the salivary cotinine concentration by the equation y=2.31x+4.76 (x=the concentration of cotinine in saliva, y=the concentration of cotinine in plasma). The results show that through the accurate determination of cotinine in saliva, the risk of ETS-exposed human can be predicted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号