首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.

Aim/background

We sought to determine the tolerance level and complication rates of the vaginal vault to combined high-dose-rate intra-cavitary brachytherapy with concomitant chemo-radiotherapy.

Patients and methods

A retrospective review of medical records of all the patients who received definitive chemo-radiotherapy for cervical cancer between 1998 and 2002 was undertaken. The records were reviewed for doses and for radiation-associated early and late sequelae of the vagina, rectum and bladder. Cumulative biological effective dose was calculated for two reference vaginal surface points.

Results

Fifty patients were included. Average age at diagnosis was 54 years. Median follow-up was 59 months. There were no recorded instances of acute grade IV toxicity. Maximal high-dose-rate vaginal surface dose (upper central point) was 103 Gy, and maximal brachytherapy lateral surface dose was 70 Gy. Maximal cumulative biological effective dose for the lateral surface reference point was 465.5 Gy3, and the maximal cumulative biological effective dose for the superior reference point was 878.6 Gy3. There were no cases of vaginal necrosis or fistulas, and no cases of grade IV late vaginal, rectal or bladder toxicity. No correlation was found between the maximal vaginal surface dose and vaginal, rectal or bladder toxicity.

Conclusions

The maximal surface HDR brachytherapy dose of 103 Gy and the maximal cBED of 878.6 Gy3 were not associated with fistula or necrosis or other grade 3–4 vaginal complications. Concomitant chemo-radiotherapy, including pelvic radiotherapy and high-dose-rate intracavitary brachytherapy, is relatively safe for cervical cancer patients.  相似文献   

2.
PurposeRetrospective, single-institution analysis of clinical outcomes and treatment-related toxicity in patients treated with salvage I-125 low-dose rate (LDR) brachytherapy (BT) for locally-recurrent prostate cancer after radiotherapy.Materials and methodsBetween 2008 and 2018, 30 patients with biopsy-confirmed prostate cancer recurrence underwent salvage treatment with I-125 LDR-BT. Of these 30 patients, 14 were previously treated with primary external beam radiotherapy (EBRT; median dose, 73 Gy) and 16 with primary I-125 LDR-BT (145 Gy and 160 Gy in 14 and 2 cases, respectively). At seed implantation, the mean age was 75.8 years, with a median Gleason score of 7 and pre-salvage PSA of <10 ng/mL. Six patients received androgen deprivation therapy for six months after relapse diagnosis. The prescribed salvage I-125 BT dose to the gland was 120−130 Gy, with dose restrictions of Dmax <135% (urethra) and <100% (rectum). Toxicity was evaluated according to the CTCAE scale (v4.0).ResultsAt a median follow-up of 45 months, the biochemical recurrence-free survival rates at 1, 3 and 5 years were 86.7%, 56.7% and 53.3%, respectively. Overall survival at 5 years was 87%. On the multivariate analysis, two variables were significant predictors of recurrence: PSA at relapse and nadir PSA post-salvage. Grade 3 genitourinary toxicity was observed in 5 patients (radiation-induced cystitis in 3 cases and urethral stenosis in 2) and G3 gastrointestinal toxicity in 3 patients (rectal bleeding).ConclusionSalvage therapy with I-125 brachytherapy is a safe and effective treatment option for locally-recurrent prostate cancer in previously-irradiated patients. High pre-salvage PSA and post-salvage nadir PSA values were significantly associated with a worse disease control after salvage I-125 LDR-BT. In well-selected patients, I-125 LDR-BT is comparable to other salvage therapies in terms of disease control and toxicity. However, more research is needed to determine the optimal management of locally-recurrent prostate cancer.  相似文献   

3.
PurposeA direct planning approach with multi-channel vaginal cylinders (MVCs) used for HDR brachytherapy of vaginal cancers is particularly challenging. Purpose of this study was to compare the dosimetric performances of different forward and inverse methods used for the optimization of MVC-based vaginal treatments for endometrial cancer, with a particular attention to the definition of strategies useful to limit the high doses to the vaginal mucosa.MethodsTwelve postoperative vaginal HDR brachytherapy treatments performed with MVCs were considered. Plans were retrospectively optimized with three different methods: Dose Point Optimization followed by Graphical Optimization (DPO + GrO), Inverse Planning Simulated Annealing with two different class solutions as starting conditions (surflPSA and homogIPSA) and Hybrid Inverse Planning Optimization (HIPO). Several dosimetric parameters related to target coverage, hot spot extensions and sparing of organs at risk were analyzed to evaluate the quality of the achieved treatment plans. Dose homogeneity index (DHI), conformal index (COIN) and a further parameter quantifying the proportion of the central catheter loading with respect to the overall loading (i.e., the central catheter loading index: CCLI) were also quantified.ResultsThe achieved PTV coverage parameters were highly correlated with each other but uncorrelated with the hot spot quantifiers. HomogIPSA and HIPO achieved higher DHIs and CCLIs and lower volumes of high doses than DPO + GrO and surflPSA.ConclusionsWithin the investigated optimization methods, HIPO and homoglPSA showed the highest dose homogeneity to the target. In particular, homogIPSA resulted also the most effective in reducing hot spots to the vaginal mucosa.  相似文献   

4.

Background

Prostate cancer is an illness with a high incidence, especially among older men. The choice of a treatment option among men above 75 years is, however, not clear. Radical prostatectomy in this age group is connected with a relatively high morbidity. A further possibility of curative treatment is radiotherapy which can be administered in the form of external beam or in combination with high dose rate (HDR) brachytherapy.

Aim

The aim of our work was to evaluate how HDR brachytherapy is tolerated among men older than 75 and how associated diseases can influence the tolerance to this treatment. Of interest to us were the treatment results and mortality from other diseases.

Materials and methods

We analyzed a sample of 20 men above 75 years old (median 77 years) who were undergoing treatment by a combination of external radiotherapy and brachytherapy. Sixteen (80%) of them had prostate cancer with an intermediate and high risk of recurrence, four had low risk prostate cancer. Most patients, 14 (70%), had less than two comorbidities.

Results

The median observation period was 57 months. No perioperative complications were recorded. Acute genitourinary toxicity (GU) to a maximum grade of 1–2 manifested in 60% of cases. Acute gastrointestinal toxicity (GIT) was observed only at grade 1 and in 25% of cases. Late GU toxicity occurred in 35% of patients, with only one showing grade 3; late GIT toxicity was recorded at grade 1 only in 3 patients (15%). 70% of the men lived longer than 3 years after treatment, at present, 50% lived more than 5 years. Long-term biochemical remission was achieved in 18 patients (90%).

Conclusions

HDR BRT is possible and well-tolerated in older men above 75 years in good condition and without serious intercurrence.Well-selected older patients with higher-risk tumours and without serious comorbidities undoubtedly benefit from radical treatment when compared with watchful waiting.  相似文献   

5.

Background

Low-dose rate brachytherapy is a well established treatment modality of oral cancer. Data about high-dose rate (HDR) brachytherapy are still sparse with various fractionation schedules and heterogeneous results.

Aim

The aim of our retrospective study was to evaluate the results of HDR brachytherapy with doses of 3 Gy twice daily.

Patients and methods

Twenty patients with squamous cell tongue cancer were treated in the years 2001–2009 by exclusive HDR BT 18 × 3 Gy twice daily. The plastic tube technique was used. Median follow up was 47 months (7.8–118) since brachytherapy.

Results

The local and locoregional control was 85% and 68%, respectively. Bone necrosis developed in one case treated without mandibular shielding and soft tissue necrosis in 2 cases.

Conclusion

It can be concluded that HDR brachytherapy with 18 × 3 Gy twice daily is safe with promising local control. The risk of nodal recurrences is substantial.  相似文献   

6.
7.
8.

Objective

To compare the efficacy and safety of high dose rate (HDR) and low dose rate (LDR) brachytherapy in treating early-stage oral cancer.

Data Sources

A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies.

Study Selection

Only randomized controlled trials (RCT) and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III) were of interest.

Data Extraction and Synthesis

Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR) met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62–2.01), overall mortality (OR = 1.01, CI 95% 0.61–1.66) and Grade 3/4 complications (OR = 0.86, CI 95% 0.52–1.42).

Conclusions

This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.  相似文献   

9.
BackgroundRadiation with or without chemotherapy is the main treatment of nasopharyngeal carcinomas (NPC). Local recurrence is difficult to manage. Local control is dose-dependent.AimTo analyze the effect of an endocavitary brachytherapy boost after external beam radiation (EBRT) to decrease local recurrence.Material and methodsThirty patients with T0-T2 NPC were treated: 70% T1, 20% T2 and 10% T0; 33.3% N0, 20% N1, 43.3% N2 and 3.3% N3; 90% were undifferentiated carcinoma. All they received a 192-Ir high dose rate brachytherapy (HDR-BT) boost after 60 Gy of EBRT. The Rotterdam applicator was used in most cases, 3-4 fractions of 3.75-3 Gy in two days.ResultsWith median follow-up (FU) of 63 months, a single parapharyngeal failure resulted in local control of 100% at 3 years and 95% at 5 years. Local control for T0-1 was 100% and for T2 67% at five years (p = 0.02). Regional-free recurrence survival was 92% at 5 years. Metastasis-free survival was 84% at 5 years. All cases of metastasis had histopathology of undifferentiated. The overall and cause-specific survival was 96% and 86% at 3 and 5 years. No late complications related to brachytherapy were described.ConclusionA HDR-BT boost is useful to decrease the incidence of local recurrence of NPC to 5%. With a fractionated schedule of 3-4 fractions in two days, Rotterdam applicator and 3-D planning, no late complications are described. Therefore we recommend to use brachytherapy boost in all early NPC.  相似文献   

10.

Aim

The aim of the study is to evaluate the differences in dosimetry between tandem-ovoid and tandem-ring gynaecologic brachytherapy applicators in image based brachytherapy.

Background

Traditionally, tandem ovoid applicators were used to deliver dose to tumor in intracavitary brachytherapy. Tandem-ring, tandem-cylinder and hybrid intracavitary, interstitial applicators are also used nowadays in cervical cancer brachytherapy.

Methods and materials

100 CT datasets of cervical cancer patients (stage IB2 – IIIB) receiving HDR application (50 tandem-ovoid and 50 tandem-ring) were studied. Brachytherapy was delivered using a CT-MRI compatible tandem-ovoid (50 patients) and a tandem-ring applicator (50 patients). DVHs were calculated and D2cc was recorded for the bladder and rectum and compared with the corresponding ICRU point doses. The point B dose, the treated volume, high dose volume and the treatment time were recorded and compared for the two applicators.

Results

The mean D2cc of the bladder with TR applicator was 6.746 Gy. TO applicator delivered a mean D2cc of 7.160 Gy to the bladder. The mean ICRU bladder points were 5.60 and 5.63 Gy for TR and TO applicator, respectively. The mean D2cc of the rectum was 4.04 Gy and 4.79 Gy for TR and TO applicators, respectively. The corresponding ICRU point doses were 5.10 Gy and 5.66 Gy, respectively.

Conclusions

The results indicate that the OAR doses assessed by DVH criteria were higher than ICRU point doses for the bladder with both tandem-ovoid and tandem-ring applicators whereas DVH based dose was lower than ICRU dose for the rectum. The point B dose, the treated volume and high dose volume was found to be slightly higher with the tandem-ovoid applicator. The mean D2cc dose for the bladder and rectum was lower with tandem-ring applicators. The clinical implication of the above dosimetric differences needs to be evaluated further.  相似文献   

11.
BackgroundThe treatment of early stage cervical cancer has different therapeutic options. Adjuvant external beam radiotherapy for surgically treated intermediate risk cervical cancer patients has shown acceptable oncological outcomes with a low incidence of toxicity. The aim of this study was to analyze the oncological outcomes and safety of adjuvant small pelvic field radiotherapy in surgically treated stage IB1-2 cervical cancer patients who met the Sedlis intermediate-risk criteria.Materials and methodsA retrospective cohort study was carried out with 28 patients treated from 2007 to November 2019 with biopsy proven intermediate risk stage IB1–2 cervical cancer previously treated with radical hysterectomy and bilateral lymphadenectomy who received adjuvant small pelvic field radiotherapy. The primary endpoints were local and distant control and overall survival. Secondary endpoints were acute and late gastrointestinal and genitourinary toxicity. Survival curves were analyzed using the Kaplan-Meier method.ResultsAfter a median follow up period of 41.5 (27.5–80.5) months, adjuvant small pelvic field radiotherapy showed a 100% overall survival rate, 81.82% disease free survival and 86.36% local recurrence-free survival with no incidence of grade 3 or 4 acute or late toxicity. Three patients suffered from relapse, 1 in the vaginal cuff, 1 in the retrovesical area and 1 patient in the retroperitoneal area.ConclusionsAdjuvant small pelvic field radiotherapy is an efficient and safe treatment option that offers excellent oncological outcomes to surgically treated intermediate-risk stage IB1–2 cervical cancer patients with an excellent toxicity profile.  相似文献   

12.
AimTo evaluate the treatment plans of 3D image-guided brachytherapy (BT) and stereotactic robotic radiotherapy with online image guidance – CyberKnife (CK) in patients with locally advanced cervix cancer.Methods and materialsTen pairs of plans for patients with locally advanced inoperable cervical cancer were created using MR based 3D brachytherapy and stereotaxis CK. The dose that covers 98% of the target volume (HR CTV D98) was taken as a reference and other parameters were compared.ResultsOf the ten studied cases, the dose from D100 GTV was comparable for both devices, on average, the BT GTV D90 was 10–20% higher than for CK. The HR CTV D90 was higher for CK with an average difference of 10–20%, but only fifteen percent of HR CTV (the peripheral part) received a higher dose from CK, while 85% of the target volume received higher doses from BT. We found a significant organ-sparing effect of CK compared to brachytherapy (20–30% lower doses in 0.1 cm3, 1 cm3, and 2 cm3).ConclusionBT remains to be the best method for dose escalation. Due to the significant organ-sparing effect of CK, patients that are not candidates for BT could benefit from stereotaxis more than from classical external beam radiotherapy.  相似文献   

13.
PurposeThree MOSkins dosimeters were assembled over a rectal probe and used to perform in vivo dosimetry during HDR brachytherapy treatments of vaginal cancer. The purpose of this study was to verify the applicability of the developed tool to evaluate discrepancies between planned and measured doses to the rectal wall.Materials and methodsMOSkin dosimeters from the Centre for Medical Radiation Physics are particularly suitable for brachytherapy procedures for their ability to be easily incorporated into treatment instrumentation. In this study, 26 treatment sessions of HDR vaginal brachytherapy were monitored using three MOSkin mounted on a rectal probe. A total of 78 measurements were collected and compared to doses determined by the treatment planning system.ResultsMean dose discrepancy was determined as 2.2 ± 6.9%, with 44.6% of the measurements within ±5%, 89.2% within ±10% and 10.8% higher than ±10%. When dose discrepancies were grouped according to the time elapsed between imaging and treatment (i.e., group 1: ≤90 min; group 2: >90 min), mean discrepancies resulted in 4.7 ± 3.6% and 7.1 ± 5.0% for groups 1 and 2, respectively. Furthermore, the position of the dosimeter on the rectal catheter was found to affect uncertainty, where highest uncertainties were observed for the dosimeter furthest inside the rectum.ConclusionsThis study has verified MOSkin applicability to in-patient dose monitoring in gynecological brachytherapy procedures, demonstrating the dosimetric rectal probe setup as an accurate and convenient IVD instrument for rectal wall dose verification. Furthermore, the study demonstrates that the delivered dose discrepancy may be affected by the duration of treatment planning.  相似文献   

14.
PurposeDosimetric assessment of high dose rate (HDR) brachytherapy applicators, printed in 3D with acrylonitrile butadiene styrene (ABS) at different infill percentage.Materials and methodsA low-cost, desktop, 3D printer (Hamlet 3DX100, Hamlet, Dublin, IE) was used for manufacturing simple HDR applicators, reproducing typical geometries in brachytherapy: cylindrical (common in vaginal treatment) and flat configurations (generally used to treat superficial lesions). Printer accuracy was investigated through physical measurements. The dosimetric consequences of varying the applicator’s density by tuning the printing infill percentage were analysed experimentally by measuring depth dose profiles and superficial dose distribution with Gafchromic EBT3 films (International Specialty Products, Wayne, NJ). Dose distributions were compared to those obtained with a commercial superficial applicator.ResultsMeasured printing accuracy was within 0.5 mm. Dose attenuation was not sensitive to the density of the material. Surface dose distribution comparison of the 3D printed flat applicators with respect to the commercial superficial applicator showed an overall passing rate greater than 94% for gamma analysis with 3% dose difference criteria, 3 mm distance-to-agreement criteria and 10% dose threshold.ConclusionLow-cost 3D printers are a promising solution for the customization of the HDR brachytherapy applicators. However, further assessment of 3D printing techniques and regulatory materials approval are required for clinical application.  相似文献   

15.
AimThe aim of this study is to analyse the dosimetry to the pelvic lymph nodes and its correlation to point B using CT based high dose rate brachytherapy of carcinoma cervix.BackgroundConventionally, dose to pelvic lymph nodes from intracavitary brachytherapy was reported by point B and by the reference points of the lymphatic trapezoid.Materials and methods30 consecutive CT based high dose rate applications were reviewed between February and March 2016. The high risk clinical target volume and the organs at risk and the pelvic nodal groups were contoured. DVH parameters for the right and left obturator nodal group, right and left external iliac nodal group and right and left internal iliac nodal group were recorded. Right and left point B doses were also recorded.ResultsOn analysis of the combined dose, it was found that all the DVH parameters were significantly different from point B, except the D100 obturator and D2cc internal iliac lymph node. There was a significant correlation between all DVH parameters and point B, except D2cc, D1cc and D0.1cc of external iliac. The obturator group received the highest dose contribution from brachytherapy. The mean D90 dose received per fraction for the obturator, external iliac and internal iliac nodes was 2.7 Gy, 1.17 Gy and 1.41 Gy, respectively.ConclusionsThere is a significant dose contribution to the pelvic lymph nodal groups during intracavitary brachytherapy. There is a low degree of correlation between point B dose and dosimetric parameters of the individual nodal groups. Hence, it is important to analyse the dose delivered to individual nodal groups during intracavitary brachytherapy, at least in patients with enlarged lymph nodes to calculate the cumulative dose delivered.  相似文献   

16.
A new tandem applicator with tungsten shield for Ir-192 radiation source used in intra-cavitary brachytherapy (ICBT) enabled intensity modulated brachytherapy (IMBT) in cervical cancer treatment through fluence-modulation by rotating shield. Our previous work employed group-wise and element-wise sparsity constraints for plan optimization of tandem applicator to minimizes the number of activated angles and source dwell points for delivery efficiency. It, however, did not incorporate the ovoid applicators into the optimizing process, which is generally used to prevent cancer recurrence. To integrate ovoid applicators to the new tandem applicator, this work proposed a comprehensive framework that modifies 1) dose deposition matrix for inverse planning, and 2) plan optimizing algorithm. The dose deposition matrix was newly formulated by the Monte-Carlo simulated dose distribution for 10 positions of ovoid applicators, followed by combining those with tandem-associated dose deposition matrix. The plan optimizing algorithm decomposed entire elements into tandem and ovoid applicators, which were governed by different constraints adaptive to specified plan objectives. The integrated framework was compared against conventional ICBT, and IMBT with tandem only for three patients with asymmetric dose distributions. Integrated IMBT framework resulted in the most optimal plans. Including fluence-modulation by rotating-shield outperformed conventional ICBT in dose sparing to critical organs. Adopting ovoid applicators to the optimization yielded more conformal dose distribution around inferior, laterally expanded region of target volume. The resulting plans reduced D5cc and D2cc by 30.9% and 27.8% for critical organs over conventional ICBT, and by 20.6% and 21.5% for target volume over IMBT with tandem only.  相似文献   

17.
BackgroundThe objective of the study was to dosimetrically compare the intensity-modulated-arc-therapy (IMAT), Cyber-Knife therapy (CK), single fraction interstitial high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy (BT) in low-risk prostate cancer.Materials and methodsTreatment plans of ten patients treated with CK were selected and additional plans using IMAT, HDR and LDR BT were created on the same CT images. The prescribed dose was 2.5/70 Gy in IMAT, 8/40 Gy in CK, 21 Gy in HDR and 145 Gy in LDR BT to the prostate gland. EQD2 dose-volume parameters were calculated for each technique and compared.ResultsEQD2 total dose of the prostate was significantly lower with IMAT and CK than with HDR and LDR BT, D90 was 79.5 Gy, 116.4 Gy, 169.2 Gy and 157.9 Gy (p < 0.001). However, teletherapy plans were more conformal than BT, COIN was 0.84, 0.82, 0.76 and 0.76 (p < 0.001), respectively. The D2 to the rectum and bladder were lower with HDR BT than with IMAT, CK and LDR BT, it was 66.7 Gy, 68.1 Gy, 36.0 Gy and 68.0 Gy (p = 0.0427), and 68.4 Gy, 78.9 Gy, 51.4 Gy and 70.3 Gy (p = 0.0091) in IMAT, CK, HDR and LDR BT plans, while D0.1 to the urethra was lower with both IMAT and CK than with BTs: 79.9 Gy, 88.0 Gy, 132.7 Gy and 170.6 Gy (p < 0.001). D2 to the hips was higher with IMAT and CK, than with BTs: 13.4 Gy, 20.7 Gy, 0.4 Gy and 1.5 Gy (p < 0.001), while D2 to the sigmoid, bowel bag, testicles and penile bulb was higher with CK than with the other techniques.ConclusionsHDR monotherapy yields the most advantageous dosimetrical plans, except for the dose to the urethra, where IMAT seems to be the optimal modality in the radiotherapy of low-risk prostate cancer.  相似文献   

18.
IntroductionElectron beam radiation is the modality most often used to deliver an operative bed boost to breast cancer patients after completing whole breast radiation. However, electrons can potentially provide inadequate coverage. The MammoSite breast brachytherapy applicator may provide dosimetric advantages in the delivery of an operative bed boost and its role in this setting is not yet defined.Materials and methodsThe study population consisted of 15 patients with early stage breast cancer treated with partial breast irradiation (PBI) using the MammoSite device. For each patient, a theoretical boost plan using electrons and a second theoretical boost plan using the MammoSite applicator were created. To assess the adequacy of each boost plan, the PTV V90, PTV V95, and PTV V100 were calculated. To assess dose to normal tissues, the ipsilateral breast V50, ipsilateral lung V30, and heart V20 were calculated.ResultsThe mean PTV V100 for the MammoSite boost was 95.5%, compared to 77.4% for the electron boost (p < 0.001). The mean PTV V95 was 97.8%, compared to 93.3% for the electron boost (p = 0.02). The mean PTV V90, mean breast V50, mean lung V30, and mean heart V20 were not statistically different for MammoSite compared to electrons.ConclusionsA tumor bed boost using the MammoSite breast brachytherapy applicator provides superior target coverage and delivers similar doses to the ipsilateral breast and lung compared to a boost delivered with electrons. More investigation into the role of balloon brachytherapy in the delivery of a breast boost is warranted.  相似文献   

19.
PurposeA dosimetric audit of Ir-192 high dose rate (HDR) brachytherapy remote after-loading units was carried out in 2019. All six brachytherapy departments on the island of Ireland participated in an end-to-end test and in a review of local HDR dosimetry procedures.Materials and methodsA 3D-printed customised phantom was created to position the following detectors at known distances from the HDR source: a Farmer ionization chamber, GafChromic film and thermoluminescent dosimeters (TLDs). Dedicated HDR applicator needles were used to position an Ir-192 source at 2 cm distance from these detectors. The end-to-end dosimetry audit pathway was performed at each host site and included the stages of imaging, applicator reconstruction, treatment planning and delivery. Deviations between planned and measured dose distributions were quantified using gamma analysis methods. Local procedures were also discussed between auditors and hosts.ResultsThe mean difference between Reference Air Kerma Rate (RAKR) measured during the audit and RAKR specified by the vendor source certificate was 1.3%. The results of end-to-end tests showed a mean difference between calculated and measured dose of 2.5% with TLDs and less than 0.5% with Farmer chamber measurements. GafChromic films showed a mean gamma passing rates of >95% for plastic and metal applicators with 2%/1 mm global tolerance criteria.ConclusionsThe results of this audit indicate dosimetric consistency between centres. The ‘end to end’ dosimetry audit methodology for HDR brachytherapy has been successfully implemented in a multicentre environment, which included different models of Ir-192 sources and different treatment planning systems.The ability to create a 3D-printed water-equivalent phantom customised to accurately position all three detector types simultaneously at controlled distances from the Ir-192 source under evaluation gives good reproducibility for end-to-end methodology.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号