首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cells within connective tissues are routinely subjected to a wide range of non-uniform mechanical loads that regulate many cell behaviors. In the present study, the relationship between cell orientation angle and strain value of the membrane was comprehensively investigated using an inhomogeneous strain field. Additionally, the cellular axial strain threshold, which corresponds to the launching of cell reorientation response, was elucidated. Human bone marrow mesenchymal stem cells were used for these experiments. In this study, an inhomogeneous strain distribution was easily created by removing one side holes of an elastic chamber in a commonly used uniaxial stretching device. The strains of 2D stretched membranes were quantified on a position-by-position basis using the digital image correlation method. The normal strain in the direction of stretch was changed continuously from 2.0 to 15.0 %. A 3D histogram of the cell frequency, which was correlated with the cell orientation angle and normal strain of the membrane, made it possible to determine the axial strain threshold accurately. The value of the axial strain threshold was 4.4 ± 0.3 %, which was reasonable compared with previous studies based on cyclic uniaxial stretch stimulation (homogeneous strain field). Additionally, preferential axial strain of cells, which was a cell property firstly introduced, was also achieved and the value was ?2.0 ± 0.1 %. This study is novel in three respects: (i) it precisely and easily determined the axial strain threshold of cells; (ii) it is the first to suggest preferential axial strain of cells; and (iii) it methodically investigated cell behavior in an inhomogeneous strain field.  相似文献   

2.
The development of a multi-sample strain device and elastomeric culture wells designed to systematically assess strain effects on cell cultures is presented in this report. This device enables one to precisely conduct experimental analyses in sterile conditions while delivering cyclic uniaxial tensile strain. The input to the computer interface allows one to alter variables of frequency, duration, and amplitude of strain. The influence of strain on the migration of human umbilical vein endothelial cell (HUVEC) cultured on 2D polydimethylsiloxane (PDMS) surfaces was examined to verify the utility of this system.  相似文献   

3.
A computer controlled dynamic bioreactor for continuous ultra-slow uniaxial distraction of a scaffold-free three-dimensional (3D) mesenchymal stem cell pellet culture was designed to investigate the influence of stepless tensile strain on behavior of distinct primary cells like osteoblasts, chondroblasts, or stem cells without the influence of an artificial culture matrix. The main advantages of this device include the following capabilities: (1) Application of uniaxial ultra-slow stepless distraction within a range of 0.5-250 μm/h and real-time control of the distraction distance with high accuracy (mean error -3.4%); (2) tension strain can be applied on a 3D cell culture within a standard CO(2) -incubator without use of an artificial culture matrix; (3) possibility of histological investigation without loss of distraction; (4) feasibility of molecular analysis on RNA and protein level. This is the first report on a distraction device capable of applying continuous tensile strain to a scaffold-free 3D cell culture within physiological ranges of motion comparable to distraction ostegenesis in vivo. We expect the newly designed microdistraction device to increase our understanding on the regulatory mechanisms of mechanical strains on the metabolism of stem cells.  相似文献   

4.
Collagen content and organization in developing collagenous tissues can be influenced by local tissue strains and tissue constraint. Tissue engineers aim to use these principles to create tissues with predefined collagen architectures. A full understanding of the exact underlying processes of collagen remodeling to control the final tissue architecture, however, is lacking. In particular, little is known about the (re)orientation of collagen fibers in response to changes in tissue mechanical loading conditions. We developed an in vitro model system, consisting of biaxially-constrained myofibroblast-seeded fibrin constructs, to further elucidate collagen (re)orientation in response to i) reverting biaxial to uniaxial static loading conditions and ii) cyclic uniaxial loading of the biaxially-constrained constructs before and after a change in loading direction, with use of the Flexcell FX4000T loading device. Time-lapse confocal imaging is used to visualize collagen (re)orientation in a nondestructive manner.Cell and collagen organization in the constructs can be visualized in real-time, and an internal reference system allows us to relocate cells and collagen structures for time-lapse analysis. Various aspects of the model system can be adjusted, like cell source or use of healthy and diseased cells. Additives can be used to further elucidate mechanisms underlying collagen remodeling, by for example adding MMPs or blocking integrins. Shape and size of the construct can be easily adapted to specific needs, resulting in a highly tunable model system to study cell and collagen (re)organization.  相似文献   

5.
Mechanical stimulation is considered to be one of the major epigenetic factors regulating the metabolism, proliferation, survival and differentiation of cells in the skeletal tissues. It is generally accepted that the cytoskeleton can undergo remodeling in response to mechanical stimuli such as tensile strain or fluid flow. Mechanically induced cell deformation is one of the possible mechanotransduction pathways by which chondrocytes sense and respond to changes in their mechanical environment. Mechanical strain has a variety of effects on the structure and function of their cells in the skeletal tissues, such as chondrocytes, osteoblasts and fibroblasts. However, little is known about the effect of the quality and quantity of mechanical strain and the timing of mechanical loading on the differentiation of these cells. The present study was designed to investigate the effect of the deformation of chondrogenic cells, and cyclic compression using a newly developed culture device, by analyzing mechanobiological response to the differentiating chondrocytes. Cyclic compression between 0 and 22% strains, at 23 microHz was loaded on chondrogenic cell line ATDC5 by seeding in a mass mode on PDMS membrane, assuming direct transfer of cyclic deformation from the membrane to the cells at the same frequency. The compressive strain, induced within the membrane, was characterized based on the analysis of the finite element modeling (FEM). The results showed that the tensile strain inhibits the chondrogenic differentiation of ATDC5 cells, whereas the compressive strain enhances the chondrogenic differentiation, suggesting that the differentiation of the chondrogenic cells could be controlled by the amount and the mode of strain. In conclusion, we have developed a unique strain loading culture system to analyze the effect of various types of mechanical stimulation on various cellular activities.  相似文献   

6.
Atherosclerosis is one of the leading causes of mortality worldwide, and presents as a narrowing or occlusion of the arterial lumen. Interventions to re-open the arterial lumen can result in re-occlusion through intimal hyperplasia. Historically only de-differentiated vascular smooth muscle cells were thought to contribute to intimal hyperplasia. However recent significant evidence suggests that resident medial multipotent vascular stem cells (MVSC) may also play a role. We therefore investigated the strain response of MVSC since these resident cells are also subjected to strain within their native environment. Accordingly, we applied uniaxial 1 Hz cyclic uniaxial tensile strain at three amplitudes around a mean strain of 5%, (4–6%, 2–8% and 0–10%) to either rat MVSC or rat VSMC before their strain response was evaluated. While both cell types strain avoid, the strain avoidant response was greater for MVSC after 24 h, while VSMC strain avoid to a greater degree after 72 h. Additionally, both cell types increase strain avoidance as strain amplitude is increased. Moreover, MVSC and VSMC both demonstrate a strain-induced decrease in cell number, an effect more pronounced for MVSC. These experiments demonstrate for the first time the mechano-sensitivity of MVSC that may influence intimal thickening, and emphasizes the importance of strain amplitude in controlling the response of vascular cells in tissue engineering applications.  相似文献   

7.
Pre-osteoblast MC3T3-E1 cells were cultured in hyaluronic acid-modified chitosan/collagen/nano-hydroxyapatite (HA-CS/Col/nHAP) composite scaffolds and treated with phytoestrogen α-zearalanol (α-ZAL) to improve bone tissue formation for bone tissue engineering. Perfusion and dynamic strain were applied to three-dimensional (3D) cultured cells, which simulates mechanical microenvironment in bone tissue and solves mass transfer issues. The morphology of cell-scaffold constructs in vitro was then examined and markers of osteogenesis were assessed by immunohistochemistry staining and western blotting. The results showed that cells expanded their pseudopodia in an irregular manner and dispersed along the walls in 3D-dynamic culture. Osteogenic phenotype was increased or maintained by enhanced collagen I (COLI) levels, decreased osteopontin expression and having little effect on osteocalcin expression during the 12 days of in vitro culture. In response to α-ZAL, the cell-scaffold constructs showed inhibited cellular proliferation, enhanced the alkaline phosphatase (ALP) activity and increased ratio of osteoprotegerin to receptor activator of nuclear factor kappa B (NF-κB) ligand (RANKL). Application of perfusion and dynamic strain to cells-scaffold constructs treated with α-ZAL represents a promising approach in the studies of osteogenesis stimulation of bone tissue engineering.  相似文献   

8.
Summary Previously, we have engineered three-dimensional (3-D) skeletal muscle constructs that generate force and display a myosin heavy-chain (MHC) composition of fetal muscle. The purpose of this study was to evaluate the functional characteristics of 3-D skeletal muscle constructs cocultured with fetal nerve explants. We hypothesized that coculture of muscle constructs with neural cells would produce constructs with increased force and adult MHC isoforms. Following introduction of embryonic spinal cord explants to a layer of confluent muscle cells, the neural tissue integrated with the cultured muscle cells to form 3-D muscle constructs with extensions. Immunohistochemical labeling indicated that the extensions were neural tissue and that the junctions between the nerve extensions and the muscle constructs contained clusters of acetylcholine receptors. Compared to muscles cultured without nerve explants, constructs formed from nerve-muscle coculture showed spontaneous contractions with an increase in frequency and force. Upon field stimulation, both twitch (2-fold) and tetanus (1.7-fold) were greater in the nerve-muscle coculture system. Contractions could be elicited by electrically stimulating the neural extensions, although smaller forces are produced than with field stimulation. Severing the extension eliminated the response to electrical stimulation, excluding field stimulation, as a contributing factor. Nervemuscle constructs showed a tendency to have higher contents of adult and lower contents of fetal MHC isoforms, but the differences were not significant. In conclusion, we have successfully engineered a 3-D nerve-muscle construct that displays functional neuromuscular junctions and can be electrically stimulated to contract via the neural extensions projecting from the construct.  相似文献   

9.
To analyse mechanotransduction resulting from tensile loading under defined conditions, various devices for in vitro cell stimulation have been developed. This work aimed to determine the strain distribution on the membrane of a commercially available device and its consistency with rising cycle numbers, as well as the amount of strain transferred to adherent cells.The strains and their behaviour within the stimulation device were determined using digital image correlation (DIC). The strain transferred to cells was measured on eGFP-transfected bone marrow-derived cells imaged with a fluorescence microscope. The analysis was performed by determining the coordinates of prominent positions on the cells, calculating vectors between the coordinates and their length changes with increasing applied tensile strain.The stimulation device was found to apply homogeneous (mean of standard deviations approx. 2% of mean strain) and reproducible strains in the central well area. However, on average, only half of the applied strain was transferred to the bone marrow-derived cells. Furthermore, the strain measured within the device increased significantly with an increasing number of cycles while the membrane's Young's modulus decreased, indicating permanent changes in the material during extended use. Thus, strain magnitudes do not match the system readout and results require careful interpretation, especially at high cycle numbers.  相似文献   

10.
The ability to create extracellular matrix (ECM) constructs that are mechanically and biochemically similar to those found in vivo and to understand how their properties affect cellular responses will drive the next generation of tissue engineering strategies. To date, many mechanisms by which cells biochemically communicate with the ECM are known. However the mechanisms by which mechanical information is transmitted between cells and their ECM remain to be elucidated. "Self-assembled" collagen matrices provide an in vitro-model system to study the mechanical behavior of ECM. To begin to understand how the ECM and the cells interact mechanically, the three-dimensional (3D) mechanical properties of the ECM must be quantified at the micro-(local) level in addition to information measured at the macro-(global) level. Here we describe an incremental digital volume correlation (IDVC) algorithm to quantify large (>0.05) 3D mechanical strains in the microstructure of 3D collagen matrices in response to applied mechanical loads. Strain measurements from the IDVC algorithm rely on 3D confocal images acquired from collagen matrices under applied mechanical loads. The accuracy and the precision of the IDVC algorithm was verified by comparing both image volumes collected in succession when no deformation was applied to the ECM (zero strain) and image volumes to which simulated deformations were applied in both ID and 3D (simulated strains). Results indicate that the IDVC algorithm can accurately and precisely determine the 3D strain state inside largely deformed collagen ECMs. Finally, the usefulness of the algorithm was demonstrated by measuring the microlevel 3D strain response of a collagen ECM loaded in tension.  相似文献   

11.
Almost all types of cellsin vivoare constantly subjected to mechanical deformation derived from muscular movement, respiration, or blood pulsation. In order to elucidate how cells and their cytoskeletal components respond to these stimuli, we developed a new device which can apply a wide range of uniaxial cyclic strain to cultured cells. When the cells were subjected to this stimulation, their stress fibers were rapidly arranged at a specific oblique angle relative to the direction of stretching. This stress fiber angulation showed a close relationship to the amplitude of stretching.  相似文献   

12.
This study aimed to investigate stepwise remodeling of human mesenchymal stem cells (hMSCs) in response to cyclic stretch through rearrangement and alignment of cells and cytoskeleton regulation toward smooth muscle cell (SMC) fate in different time spans. Image analysis techniques were utilized to calculate morphological parameters. Cytoskeletal reorganization was observed by investigating F-actin filaments using immunofluorescence staining, and expression level of contractile SMC markers was followed by a quantitative polymerase chain reaction method. Applying cyclic uniaxial stretch on cultured hMSCs, utilizing a costume-made device, led to alteration in fractal dimension (FD) and cytoskeleton structure toward continuous alignment and elongation of cells by elevation of strain duration. Actin filaments became more aligned perpendicular to the axis of mechanical stretch by increasing uniaxial loading duration. At first, FD met a significant decrease in 4 h loading duration then increased significantly by further loading up to 16 h, followed by another decrease up to 1 d of uniaxial stretching. HMSCs subjected to 24 h cyclic uniaxial stretching significantly expressed early and intermediate contractile SM markers. It was hypothesized that the increase in FD after 4 h while cells continuously became more aligned and elongated was due to initiation of change in phenotype that influenced arrangement of cells. At this point, change in cell phenotype started leading to change in morphology while mechanical loading still caused cell alignment and rearrangement. Results can be helpful when optimized engineered cells are needed based on mechanical condition for functional engineered tissue and cell therapy.  相似文献   

13.
Cells have the ability to actively sense their mechanical environment and respond to both substrate stiffness and stretch by altering their adhesion, proliferation, locomotion, morphology, and synthetic profile. In order to elucidate the interrelated effects of different mechanical stimuli on cell phenotype in vitro, we have developed a method for culturing mammalian cells in a two-dimensional environment at a wide range of combined levels of substrate stiffness and dynamic stretch. Polyacrylamide gels were covalently bonded to flexible silicone culture plates and coated with monomeric collagen for cell adhesion. Substrate stiffness was adjusted from relatively soft (G′ = 0.3 kPa) to stiff (G′ = 50 kPa) by altering the ratio of acrylamide to bis-acrylamide, and the silicone membranes were stretched over circular loading posts by applying vacuum pressure to impart near-uniform stretch, as confirmed by strain field analysis. As a demonstration of the system, porcine aortic valve interstitial cells (VIC) and human mesenchymal stem cells (hMSC) were plated on soft and stiff substrates either statically cultured or exposed to 10% equibiaxial or pure uniaxial stretch at 1Hz for 6 hours. In all cases, cell attachment and cell viability were high. On soft substrates, VICs cultured statically exhibit a small rounded morphology, significantly smaller than on stiff substrates (p<0.05). Following equibiaxial cyclic stretch, VICs spread to the extent of cells cultured on stiff substrates, but did not reorient in response to uniaxial stretch to the extent of cells stretched on stiff substrates. hMSCs exhibited a less pronounced response than VICs, likely due to a lower stiffness threshold for spreading on static gels. These preliminary data demonstrate that inhibition of spreading due to a lack of matrix stiffness surrounding a cell may be overcome by externally applied stretch suggesting similar mechanotransduction mechanisms for sensing stiffness and stretch.  相似文献   

14.
The ability to migrate is a hallmark of various cell types and plays a crucial role in several physiological processes, including embryonic development, wound healing, and immune responses. However, cell migration is also a key mechanism in cancer enabling these cancer cells to detach from the primary tumor to start metastatic spreading. Within the past years various cell migration assays have been developed to analyze the migratory behavior of different cell types. Because the locomotory behavior of cells markedly differs between a two-dimensional (2D) and three-dimensional (3D) environment it can be assumed that the analysis of the migration of cells that are embedded within a 3D environment would yield in more significant cell migration data. The advantage of the described 3D collagen matrix migration assay is that cells are embedded within a physiological 3D network of collagen fibers representing the major component of the extracellular matrix. Due to time-lapse video microscopy real cell migration is measured allowing the determination of several migration parameters as well as their alterations in response to pro-migratory factors or inhibitors. Various cell types could be analyzed using this technique, including lymphocytes/leukocytes, stem cells, and tumor cells. Likewise, also cell clusters or spheroids could be embedded within the collagen matrix concomitant with analysis of the emigration of single cells from the cell cluster/ spheroid into the collagen lattice. We conclude that the 3D collagen matrix migration assay is a versatile method to analyze the migration of cells within a physiological-like 3D environment.  相似文献   

15.
Kaunas R  Usami S  Chien S 《Cellular signalling》2006,18(11):1924-1931
Cyclic mechanical stretch associated with pulsatile blood pressure can modulate cytoskeletal remodeling and intracellular signaling in vascular endothelial cells. The aim of this study was to evaluate the role of stretch-induced actin stress fiber orientation in intracellular signaling involving the activation of c-jun N-terminal kinase (JNK) in bovine aortic endothelial cells. A stretch device was designed with the capability of applying cyclic uniaxial and equibiaxial stretches to cultured endothelial cells, as well as changing the direction of cyclic uniaxial stretch. In response to 10% cyclic equibiaxial stretch, which did not result in stress fiber orientation, JNK activation was elevated for up to 6 h. In response to 10% cyclic uniaxial stretch, JNK activity was only transiently elevated, followed by a return to basal level as the actin stress fibers became oriented perpendicular to the direction of stretch. After the stress fibers had aligned perpendicularly and the JNK activity had subsided, a 90-degree change in the direction of cyclic uniaxial stretch reactivated JNK, and this activation again subsided as stress fibers became re-oriented perpendicular to the new direction of stretch. Disrupting actin filaments with cytochalasin D blocked the stress fiber orientation in response to cyclic uniaxial stretch and it also caused the uniaxial stretch-induced JNK activation to become sustained. These results suggest that stress fiber orientation perpendicular to the direction of stretch provides a mechanism for both structural and biochemical adaptation to cyclic mechanical stretch.  相似文献   

16.
Cellular mechanical characteristics represent cell ability to produce tissue-specific metabolites. Therefore, to achieve effective cell therapy, a better understanding of the effects of chemo-mechanical stimuli on the mechanical properties of in vitro-treated cells is essential. Herein, we investigated the effects of uniaxial strain on the mechanical properties of mesenchymal stem cells (MSCs) upon transforming growth factor beta 1 (TGF-β1) stimulation. The MSCs were categorized into control and test groups. In one test group, the MSCs were treated by TGF-β1 for 6 d, and in the other, they were additionally subjected to 1-d uniaxial strain on day 2. The cell mechanical properties and smooth muscle (SM) gene expression were assessed on days 2, 4, and 6. During the entire experiment, the MSCs treated by TGF-β1 ± uniaxial strain were induced to differentiate into SM-like cells by significantly upregulation of α-actin, SM22α, and h1-calponin in respect to the control samples. When the MSCs were treated with TGF-β1 alone, their stiffness and viscosity decreased significantly on day 2 and then increased by increase in culture time. When the cells were subjected to 1-d uniaxial strain upon TGF-β1 stimulation, their stiffness and viscosity significantly increased on days 2 and 4 and then decreased on day 6 to a level comparable to that of TGF-β1 group. Different paths were noticeable among the treated samples to reach nearly similar states on day 6. It seems that uniaxial strain activates mechanobiological cascades by which cellular mechanical behavior can be regulated after its removal. However, these effects are transient and would diminish over time. The findings may be helpful in the chemo-mechanical regulation of MSCs.  相似文献   

17.
Catecholamines have been shown to be involved in vascular remodeling through the stimulation of alpha(1)-adrenoceptors (alpha(1)-ARs). Recently, it has been demonstrated that catecholamines can stimulate angiogenesis in pathological conditions, even if the mechanisms and the AR subtypes involved still remain unclear. We investigated the influence of hypoxia (3% O(2)) on the ability of picomolar concentrations of phenylephrine (PHE), which are unable to induce any vascular contraction, to induce a trophic effect in human endothelial cells through stimulation of the alpha(1D)-subtype ARs. PHE, at picomolar concentrations, significantly promoted pseudocapillary formation from fragments of human mature vessels in vitro. Exposure to hypoxia significantly potentiated this effect, which was inhibited by the selective alpha(1D)-AR antagonist BMY-7378 and by the nitric oxide synthase inhibitor L-NAME, suggesting that alpha(1D)-ARs were involved in this effect through activation of the nitric oxide pathway. Proliferation and migration of HUVEC were also affected by picomolar PHE concentrations. Again, these effects were significantly potentiated in cells exposed to hypoxia and were inhibited by BMY-7378 and by N(G)-nitro-L-arginine methyl ester. Conversely, the alpha(1A)-AR-selective antagonist (S)-(+)-niguldipine hydrochloride and the alpha(1B)-AR antagonist chloroethylclonidine dihydrochloride did not modify endothelial cell migration and proliferation in response to PHE. These results demonstrate that the stimulation of alpha(1D)-ARs, triggered by picomolar PHE concentrations devoid of any contractile vascular effects, induces a proangiogenic phenotype in human endothelial cells that is enhanced in a hypoxic environment. The role of alpha(1D)-ARs may become more prominent in the adaptive responses to hypoxic vasculature injury.  相似文献   

18.
Mechanical compression has been shown to impact cell activity; however a need for a single device to perform a broader range of parametric studies exists. We have developed an oscillatory displacement controlled device to uniaxially strain cell constructs under both static and dynamic compression and used this device to investigate gene expression in cell constructs. The device has a wide stroke (0.25-4 mm) and frequency range (0.1-3 Hz) and several loading waveforms are possible. Alginate cellular constructs with embedded equine chondrocytes were tested and viability was maintained for the 24 h test period. Off-line mechanical testing is described and a modulus value of 18.2 +/- 1.3 kPa found for alginate disks which indicates the level of stress achieved with this deformation profile. Static (15% strain) and dynamic (15% strain, 1 Hz, triangle waveform) testing of chondrocyte constructs was performed and static compression showed significantly higher collagen II expression than dynamic using quantitative RT-PCR. In contrast, differences in matrix metalloproteinase-3 (MMP-3) expression were statistically insignificant. These studies indicate the utility of our device for studying cell activity in response to compression and suggest further studies regarding how the load and strain spectrum impact chondrocyte activity.  相似文献   

19.
Berry CC  Cacou C  Lee DA  Bader DL  Shelton JC 《Biorheology》2003,40(1-3):337-345
Fibroblasts within tissues are exposed to a dynamic mechanical environment, which influences the structural integrity of both healthy and healing soft tissues. Various systems have been proposed to subject such cells to mechanical stimulation in culture. However the diverse nature of the studies, in terms of the strain profiles and the cell types, makes direct comparisons almost impossible. The present study addresses this issue by examining the metabolic response of two cell types subjected to three well defined strain profiles.A young fibroblast cell population, represented by HuFFs, showed both greater cell proliferation and collagen production than adult dermal fibroblasts under unstrained conditions. The three strain profiles produced differing effects on both cell types. Uniaxial strains enhanced [(3)H]-thymidine incorporation for both cell types, whilst biaxial strains either inhibited or had no effect on its incorporation. In contrast, [(3)H]-proline incorporation was inhibited under biaxial and uniaxial strains for the adult fibroblasts, whilst the HuFF cells showed a small increase in proline incorporation under non-uniform and uniaxial strains.  相似文献   

20.
Cells are complex, dynamic systems that respond to various in vivo stimuli including chemical, mechanical, and scaffolding alterations. The influence of mechanics on cells is especially important in physiological areas that dictate what modes of mechanics exist. Complex, multivariate physiological responses can result from multi-factorial, multi-mode mechanics, including tension, compression, or shear stresses. In this study, we present a novel device based on elastomeric materials that allowed us to stimulate NIH 3T3 fibroblasts through uniaxial strip stretching or shear fluid flow. Cell shape and structural response was observed using conventional approaches such as fluorescent microscopy. Cell orientation and actin cytoskeleton alignment along the direction of applied force were observed to occur after an initial 3 h time period for shear fluid flow and static uniaxial strip stretching experiments although these two directions of alignment were oriented orthogonal relative to each other. This response was then followed by an increasingly pronounced cell and actin cytoskeleton alignment parallel to the direction of force after 6, 12, and 24 h, with 85% of the cells aligned along the direction of force after 24 h. These results indicate that our novel device could be implemented to study the effects of multiple modes of mechanical stimulation on living cells while probing their structural response especially with respect to competing directions of alignment and orientation under these different modes of mechanical stimulation. We believe that this will be important in a diversity of fields including cell mechanotransduction, cell–material interactions, biophysics, and tissue engineering.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号