首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
目的:通过对比通道辅助跟腱微创缝合方式(CAMIR)与2种临床最常用的跟腱缝合方式的生物力学强度,验证CAMIR微创缝合方式同样能够达到常规缝合方式的力学强度,为临床推广应用提供可靠的理论依据。方法:将27支跟腱样本随机分为3组(每组9支),分别是CAMIR组、经典微创Ma-Griffith组、标准切开Krackow组。所有跟腱样本首先预加载50N,2min。然后以20N-100N,1Hz,循环1000次。如果缝合未失效,则以20 mm/s的速度将样本拉伸至失效。通过实验仪上的传感器自动记录循环1000次时整个缝合结构的伸长量,记录拉伸失效时整个缝合结构的伸长量以及最大负荷,并计算单纯拉伸阶段缝合结构的抗拉伸硬度。结果:CAMIR的循环1000次结束时伸长量(P=0.581)、缝合失效时伸长量(P=0.799)、缝合失效时最大负荷(P=0.278)、单纯拉伸过程中抗应变硬度(P=0.935)与常用的Ma-Griffith、Krackow缝合方式均无明显差异。结论:CAMIR缝合方式强度可靠,为术后进行早期功能康复训练提供力学保障,同时能够有效避免腓肠神经损伤,是临床上值得推荐的微创缝合方式。  相似文献   

2.
Effect of vascular endothelial growth factor on rat Achilles tendon healing   总被引:12,自引:0,他引:12  
This study evaluated the effect of exogenous vascular endothelial growth factor (VEGF) on tendon healing and regulation of other growth factors in a rat Achilles tendon model. Fifty Sprague-Dawley rats were used. In the experimental group, the left Achilles tendon was transected and repaired with the modified Kessler suture technique, and the right Achilles tendon was transected and repaired with resection of plantaris tendon. VEGF, 100 mul (50 mug/ml), was injected into each tendon at the repair site. The same surgical procedures were performed in the control group, with the same volume of saline injected into the repair sites. At intervals of 1, 2, and 4 weeks, the animals were killed and the tendons were harvested and evaluated for tensile strength (1, 2, and 4 weeks) and gene expression (postoperative day 4). At 1 week postoperatively, when plantaris tendon was preserved, the tensile strength of the repaired tendons with VEGF treatment (3.63 +/- 0.62 MPa) was significantly higher than the tensile strength of the repaired tendons with saline treatment (2.20 +/- 0.36 MPa). There was no difference in tensile strength between the two groups without the plantaris tendon support. At 2 weeks postoperatively, the tensile strength was 11.34 +/- 3.89 MPa in the group with VEGF treatment and plantaris tendon preservation, which was significantly higher than the tensile strength in the other groups. There was no significant difference in tensile strength among the groups at 4 weeks postoperatively. The gene expression showed that transforming growth factor-beta in the VEGF-treated tendon was up-regulated in the early stage of tendon healing, whereas expression of platelet-derived growth factor, basic fibroblast growth factor, and insulin-like growth factor-1 was not significantly different among the groups. In conclusion, administration of exogenous VEGF can significantly improve tensile strength early in the course of the rat Achilles tendon healing and was associated with increased expression of transforming growth factor-beta.  相似文献   

3.
The purpose of this study was to investigate whether the mechanical properties of the Achilles tendon were correlated to muscle strength in the triceps surae in humans. Twenty-four men and twelve women exerted maximal voluntary isometric plantar flexion (MVIP) torque. The elongation (DeltaX) and strain of the Achilles tendon (epsilon), the proximal part of which is the composite of the gastrocnemius tendon and the soleus aponeurosis, at MVIP were determined from the displacement of the distal myotendinous junction of the medial gastrocnemius using ultrasonography. The Achilles tendon force at MVIP (F) was calculated from the MVIP torque and the Achilles tendon moment arm. There were no significant differences in either the F-DeltaX or F-epsilon relationships between men and women. DeltaX and epsilon were 9.8 +/- 2.6 mm and 5.3 +/- 1.6%, respectively, and were positively correlated to F (r = 0.39, P < 0.05; r = 0.39, P < 0.05), which meant that subjects with greater muscle strength could store more elastic energy in the tendon. The regression y-intercepts for the F-DeltaX (P < 0.01) and F-epsilon (P < 0.05) relationship were significantly positive. These results might indicate that the Achilles tendon was stiffer in subjects with greater muscle strength, which may play a role in reducing the probability of tendon strain injuries. It was suggested that the Achilles tendon of subjects with greater muscle strength did not impair the potential for storing elastic energy in tendons and may be able to deliver the greater force supplied from a stronger muscle more efficiently. Furthermore, the difference in the Achilles tendon mechanical properties between men and women seemed to be correlated to the difference in muscle strength rather than gender.  相似文献   

4.
The present study aimed to re-examine the influence of the isometric plantarflexors contraction on the Achilles tendon moment arm (ATMA) and the factors influencing the ATMA in three-dimensions. A series of coronal magnetic resonance images of the right ankle were recorded at foot positions of 10° of dorsiflexion, neutral position, and 10° of plantarflexion for the rest condition and the plantarflexors contraction condition at 30% maximal voluntary effort. The shortest distance between the talocrural joint axis and the line of action of the Achilles tendon force projected to the orthogonal plane of the talocrural joint axis was determined as the ATMA. The ATMA determined in the contraction condition was significantly greater by 8 mm than that determined in the rest condition. The talocrural joint axis was displaced anteriorly by 3 mm and distally by 2 mm due to the muscle contraction. As the same time, the line of action of the Achilles tendon force was displaced posteriorly by 5 mm and medially by 2 mm. These linear displacements of the talocrural joint axis and the line of action of the Achilles tendon force accounted for the difference in the ATMAs between the two conditions by 35.9 and 62.4%, respectively. These angular displacements accounted for the total of 0.4% increase in the ATMA. These results confirm the previous findings reported in two-dimensional studies and found that the linear displacement of the line of action of the Achilles tendon force is the primary source of the contraction-induced increase in the ATMA.  相似文献   

5.
In the present experiment we obtained the tensile properties of the human gastrocnemius tendon, a high-stressed tendon suitable for spring-like action during locomotion. Measurements were taken in vivo in six men. The gastrocnemius tendon elongation during tendon loading−unloading induced by muscle contraction−relaxation was measured using real-time ultrasonography. Tendon forces were calculated from the moment generated during isometric plantarflexion contraction, using tendon moment arm length data obtained in vivo with the tendon travel method. Tendon stiffness data were calculated from the slope of the tendon force−elongation curve, and were then normalized to the tendon's original dimensions, obtained from morphometric analysis of sonographs, to estimate the tendon Young's modulus. Mechanical hysteresis values were obtained from area calculations by numerical integration. The elongation of the tendon increased curvilinearly with the force acting upon it, from 1.7±1 mm (0.8±0.3% strain) at 87.5±8.5 N to 11.1±3.1 mm (4.9±1% strain) at 875±85 N. The tendon Young's modulus and mechanical hysteresis were 1.16±0.15 GPa and 18±3%, respectively. These values fall within the range of values obtained from in vitro experiments and are very similar to the respective values recently obtained from in vivo measurements in the less highly stressed human tibialis anterior tendon (1.2 GPa and 19%), thus indicating that the material properties of tendon are independent of physiological loading and function. Combining the present tendon force−elongation data with previously reported Achilles tendon force data recorded during walking indicates that the gastrocnemius tendon would provide 6% of the total external work produced by the locomotor system. This estimate illustrates the contribution of passive elastic mechanisms on the economy and efficiency of walking. The contributions would be greater in more active exercise such as running.  相似文献   

6.
The effect of loading rate on specimen calibration was investigated for an implantable force sensor of the two-point loading variety. This variety of sensor incorporates a strain gage to measure the compressive load applied to the sensor due to tensile loading in a soft tissue specimen. The Achilles tendon in each of four human cadaveric lower extremities was instrumented with a force sensor and then loaded in tension using a materials testing machine. Each specimen was tensile tested at three different displacement rates, 0.25, 2.5 and 12.7 cm s(-1), corresponding with mean loading rates of 33.8, 513.2, and 2838.6 N s(-1), respectively. A calibration curve relating the force sensor signal and applied tendon tension was generated for each specimen/ displacement rate combination. For each specimen, calibration curves were compared by calculating an RMS error for the entire data set (eRMS = 1.6% of the full load value) and a coefficient of determination, R2, of a curve fit through all of the data (R2 = 99.6%). Over the range of rates tested, no measurable change in sensor sensitivity due to loading rate was observed. Hysteresis for all displacement rates was on the order of 2.4%.  相似文献   

7.
Quadriceps tendon with a patellar bone block may be a viable alternative to Achilles tendon for anterior cruciate ligament reconstruction (ACL-R) if it is, at a minimum, a biomechanically equivalent graft. The objective of this study was to directly compare the biomechanical properties of quadriceps tendon and Achilles tendon allografts. Quadriceps and Achilles tendon pairs from nine research-consented donors were tested. All specimens were processed to reduce bioburden and terminally sterilized by gamma irradiation. Specimens were subjected to a three phase uniaxial tension test performed in a custom environmental chamber to maintain the specimens at a physiologic temperature (37 ± 2 °C) and misted with a 0.9 % NaCl solution. There were no statistical differences in seven of eight structural and mechanical between the two tendon types. Quadriceps tendons exhibited a significantly higher displacement at maximum load and significantly lower stiffness than Achilles tendons. The results of this study indicated a biomechanical equivalence of aseptically processed, terminally sterilized quadriceps tendon grafts with bone block to Achilles tendon grafts with bone block. The significantly higher displacement at maximum load, and lower stiffness observed for quadriceps tendons may be related to the failure mode. Achilles tendons had a higher bone avulsion rate than quadriceps tendons (86 % compared to 12 %, respectively). This was likely due to observed differences in bone block density between the two tendon types. This research supports the use of quadriceps tendon allografts in lieu of Achilles tendon allografts for ACL-R.  相似文献   

8.
Whether the cross-sectional area (CSA) and mechanical properties of the human Achilles tendon change in response to habitual exercise remains largely unexplored. The present study evaluated the CSA and contraction-induced displacement of the aponeurosis-tendon complex of the triceps surae in 11 untrained subjects before (tests 1 and 2) and after (test 3) approximately 9 mo of regular running ( approximately 78 training sessions). Displacement of the tendon-aponeurosis complex obtained by ultrasonography; electromyography of the gastrocnemius, soleus, and dorsiflexor muscles; and joint angular rotation were recorded during graded isometric plantarflexion ramps. Tendon CSA and moment arm were measured by using MRI, and tendon force was calculated from joint moments and tendon moment arm. A treadmill test was used to determine submaximal oxygen consumption (Vo2) at a given speed and maximal Vo2. The total running duration was approximately 43 h, distributed over 34 wk. Maximal Vo2 increased 8.6% (P < 0.01), and submaximal Vo2 decreased 6.2% (P < 0.05). Tendon-aponeurosis displacement during maximal voluntary contraction was unchanged (tests 1-3, 5.2 +/- 0.6, 5.2 +/- 0.5, and 5.3 +/- 0.4 mm, respectively) and yielded a structural stiffness of 365 +/- 50, 358 +/- 40, and 384 +/- 52 N/mm for tests 1-3, respectively (P > 0.05). Tendon CSA also remained unchanged (tests 1-3, 34.2 +/- 2.2, 33.9 +/- 2.2, and 33.8 +/- 2.1 mm2, respectively). In conclusion, a total training stimulus of approximately 9 mo of running in previously untrained subjects was adequate to induce significant cardiovascular improvements, although it did not result in any changes in the mechanical properties of the triceps surea tendon-aponeurosis complex or in the dimensions of Achilles tendon.  相似文献   

9.
Active mobilization of repaired flexor tendons requires sufficient suture strength. This study was designed to investigate the suitability of four newly developed and comparatively strong tendon sutures for flexor tendon repair with active digital mobilization. Fifty fresh flexor digitorum profundus tendons were randomly assigned to five groups and repaired using the Tang, cruciate, Robertson, Silfverskiold, and modified Kessler suture methods. The repaired tendons were subjected to mechanical testing in an Instron tensile machine to determine the 2-mm gap formation force, ultimate strength, elastic modulus, and energy to failure of the sutures. The 2-mm gap formation forces of the sutures were 43.0 N for the Tang, 37.4 N for the cruciate, 25.0 N for the Robertson, 32.3 N for the Silfverskiold, and 21.2 N for the modified Kessler methods. The ultimate strength of the sutures was 53.6 N for the Tang, 46.3 N for the cruciate, 41.6 N for the Robertson, 41.0 N for the Silfverskiold, and 24.7 N for the modified Kessler methods. Statistically, the gap formation force and ultimate strength were the highest in the Tang, higher in the cruciate, and the lowest for the Robertson and the modified Kessler methods. The elastic modulus of the repaired tendons, as represented by the linear slope of the force-displacement curve, was also statistically the largest in the Tang, larger in the cruciate, and lowest for the Robertson and modified Kessler methods. Energy to failure was statistically the largest in the Tang, higher in the cruciate, lower in the Silfverskiold and the Robertson, and the lowest for the modified Kessler methods. It was concluded that significant differences exist in mechanical properties of the newly developed tendon suture methods. Among the methods for tendon repair that were tested, the Tang and the cruciate sutures were the best candidates for flexor tendon repair in the hand with postoperative active mobilization because of their superior tensile strength, elastic properties, energy to failure, and reasonable operation time.  相似文献   

10.
The human triceps surae muscle-tendon complex is a unique structure with three separate muscle compartments that merge via their aponeuroses into the Achilles tendon. The mechanical function and properties of these structures during muscular contraction are not well understood. The purpose of the study was to investigate the extent to which differential displacement occurs between the aponeuroses of the medial gastrocnemius (MG) and soleus (Sol) muscles during plantar flexion. Eight subjects (mean +/- SD; age 30 +/- 7 yr, body mass 76.8 +/- 5.5 kg, height 1.83 +/- 0.06 m) performed maximal isometric ramp contractions with the plantar flexor muscles. The experiment was performed in two positions: position 1, in which the knee joint was maximally extended, and position 2, in which the knee joint was maximally flexed (125 degrees ). Plantarflexion moment was assessed with a strain gauge load cell, and the corresponding displacement of the MG and Sol aponeuroses was measured by ultrasonography. Differential shear displacement of the aponeurosis was quantified by subtracting displacement of Sol from that of MG. Maximal plantar flexion moment was 36% greater in position 1 than in position 2 (132 +/- 20 vs. 97 +/- 11 N.m). In position 1, the displacement of the MG aponeurosis at maximal force exceeded that of the Sol (12.6 +/- 1.7 vs. 8.9 +/- 1.5 mm), whereas in position 2 displacement of the Sol was greater than displacement of the MG (9.6 +/- 1.0 vs. 7.9 +/- 1.2 mm). The amount and "direction" of shear between the aponeuroses differed significantly between the two positions across the entire range of contraction, indicating that the Achilles tendon may be exposed to intratendinous shear and stress gradients during human locomotion.  相似文献   

11.
Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The purpose of this study was to use imaging techniques to measure the strains around the circumference of 11 mm wide Achilles tendon grafts during a uniaxial tensile test. Pairs of radiopaque beads with a diameter of 2mm were affixed around the mid-substance of the tendon in four different locations. The motion of the beads was recorded using a cine fluoroscope. This system was shown to measure the displacement of the beads with an accuracy of 0.02 mm. During the uniaxial tensile test, large variations in local tissue strains were observed. At 10 MPa of applied stress, the local tissue strain varied from an average of 2.5-8.7%, an increase in strain of more than three times. As a result of these large variations, the modulus calculated from the stress-strain data varied from an average of 217 to 897 MPa, an increase of approximately 4 times. Furthermore, these data suggest that underestimates of the elastic modulus may result if a uniform strain distribution is assumed. These results indicate that during uniaxial tensile tests, the assumption of uniform stress and strain distributions should be carefully considered and small, uniform specimens should be used when measuring the material properties of soft tissues.  相似文献   

12.
The Achilles is the thickest tendon in the body and is the primary elastic energy-storing component during running. The form and function of the human Achilles is complex: twisted structure, intratendinous interactions, and differential motor control from the triceps surae muscles make Achilles behavior difficult to intuit. Recent in vivo imaging of the Achilles has revealed nonuniform displacement patterns that are not fully understood and may result from complex architecture and musculotendon interactions. In order to understand which features of the Achilles tendon give rise to the nonuniform deformations observed in vivo, we used computational modeling to predict the mechanical contributions from different features of the tendon. The aims of this study are to: (i) build a novel computational model of the Achilles tendon based on ultrashort echo time MRI, (ii) compare simulated displacements with published in vivo ultrasound measures of displacement, and (iii) use the model to elucidate the effects of tendon twisting, intratendon sliding, retrocalcaneal insertion, and differential muscle forces on tendon deformation. Intratendon sliding and differential muscle forces were found to be the largest factors contributing to displacement nonuniformity between tendon regions. Elimination of intratendon sliding or muscle forces reduced displacement nonuniformity by 96% and 85%, respectively, while elimination of tendon twist and the retrocalcaneal insertion reduced displacement nonuniformity by only 35% and 3%. These results suggest that changes in the complex internal structure of the tendon alter the interaction between muscle forces and tendon behavior and therefore may have important implications on muscle function during movement.  相似文献   

13.
Two-dimensional methods have been applied to determine the Achilles tendon moment arm in previous studies, although the talocrural joint rotates in three-dimension. The purpose of this study was to develop a method for determining the Achilles tendon moment arm in three-dimensions (3DMA). A series of sagittal ankle images were obtained at ankle positions of -20°, -10° (dorsiflexed position), 0° (neutral position), +10°, +20°, and +30° (plantarflexed position). The talocrural joint axis was determined as the finite helical axis of the ankle joint over 20° of displacement, and the 3DMA was determined as the shortest distance from the talocrural joint axis to the line of action of the Achilles tendon force. The corresponding 2DMA was determined with the center of rotation method using the images captured on the sagittal plane passing through the mid-point of the medio-lateral width of the tibia. The 3DMA ranged from 35 to 41 mm across various ankle positions and was, on average, 11 mm smaller than 2DMA. The difference between the two measures was attributable primarily to the deviations of the talocrural joint axis from the anatomical medio-lateral direction. The deviations on the coronal plane (21.4±20.7°) and on the transverse planes (14.8±22.6°) accounted for the errors of 1.3 mm and 3.0 mm, respectively. In addition, selecting either a medially or laterally misaligned sagittal-plane image for determining the 2DMA gave rise to error by 3.5 mm. The remaining difference was accounted for by the random measurement error.  相似文献   

14.
王晓军  刘劲松  张洪彬  沈勇伟 《生物磁学》2009,(20):3897-3899,3881
目的:研究短跑训练对运动员跟腱的影响。方法:选择从事运动训练4-6年的健康男、女短跑运动员为实验组(n=12),同时选同龄健康非运动员男、女为对照组(n=12),采用高频超声检测平静状态跟腱长度、横截面积,以及小腿三头肌等长收缩最大力量跖屈跟腱长度的变化。结果:跟腱长度:对照组男子168.5±9.2mm,女子162.4±9.8mm,实验组男子170.9±10.7mm,女子164.0±7.0mm。实验组和对照组组内、组间差别均无统计学意义。跟腱横截面积:对照组男子62.2±6.2mm2,女子47.1±4.5mm2,实验组男子65.6±2.9mm2,女子49.6±1.9mm2。同组内男子比女子跟腱横截面积大,差别有统计学意义(P&lt;0.05),但实验组和对照组组间差别无统计学意义。小腿三头肌等长收缩最大力跖屈时跟腱拉长值:对照组男子7.6±3.6mm,女子4.9±2.8mm,实验组男子11.1±2.9mm,女子7.9±3.1mm。男子比女子跟腱拉长值大、实验组比对照组拉长值大,差别均有统计学意义(P&lt;0.05)。结论:短跑训练可增加跟腱可拉伸长度,跟腱的长度和横截面积未发生明显变化。高频超声可作为重要的测量手段用于...  相似文献   

15.
The mouse has proven to be an advantageous animal model system in basic science research focused on aiding in development and evaluation of potential treatments; however, the small size of mouse tendons makes consistent and reproducible injury models and subsequent biomechanical evaluation challenging for studying tendon healing. In this study, we investigated the feasibility and reproducibility of multiple mouse tendon injury models. Our hypothesis was that incisional (using a blade) and excisional (using a biopsy punch) injuries would result in consistent differences in tendon material properties. At 16 weeks of age, 17 C57BL/6 mice underwent surgery to create defects in the flexor digitorum longus, Achilles, or patellar tendon. Each animal received 1-2 full-thickness, central-width incisional or excisional injuries per limb; at least one tendon per limb remained uninjured. The injuries were distributed such that each tendon type had comparable numbers of uninjured, incisionally injured, and excisionally injured specimens. Three weeks after injury, all animals were euthanized and tendons were harvested for mechanical testing. As hypothesized, differences were detected for all three different tendon types at three weeks post-injury. While all models created injuries that produced predictable outcomes, the patellar tendon model was the most consistent in terms of number and size of significant differences in injured tendons compared to native properties, as well as in the overall variance in the data. This finding provides support for its use in fundamental tendon healing studies; however, future work may use any of these models, based on their appropriateness for the specific question under study.  相似文献   

16.
This study was performed to determine whether the viscoelastic behavior of ligaments persists at high rates of loading, such as those associated with sports-related trauma or motor vehicle accidents. Medial collateral ligaments (MCLs) from 22 skeletally mature New Zealand White rabbits were tensile tested quasi-statically and via two impact conditions at displacement rates of 0.17 mm/s (n=22), 640+/-160 mm/s (n=10) and 2500+/-270 mm/s (n=12) (corresponding to strain rates of approximately 1.0%/s, 3660%/s and 14,000%/s, respectively). Despite dramatic increases in displacement rate, only a modest strain-rate effect was observed when the specimens tested quasi-statically were compared to those tested via impact (24% and 37% increases in stiffness and failure load, respectively). There were no differences in the structural (e.g. 145+/-30 and 136+/-29 N/mm stiffness values, respectively) or failure properties (e.g. 434+/-91 and 443+/-154 N failure load values, respectively) of the two impact-tested groups. Our findings suggest that the rabbit MCL is not viscoelastic at loading rates approximating those associated with high-energy trauma.  相似文献   

17.
Not much is known about the effects of immobilization and subsequent recovery on tendon connective tissue. In the present study, healthy young men had their nondominant leg immobilized for a 2-wk period, followed by a recovery period of the same length. Immobilization resulted in a mean decrease of 6% (5,413 to 5,077 mm(2)) in cross-sectional area (CSA) of the triceps surae muscles and a mean decrease of 9% (261 to 238 N.m) in strength of the immobilized calf muscles. Two weeks of recovery resulted in a 6% increased in CSA (to 5,367 mm(2)), whereas strength remained suppressed (240 N.m). No difference in Achilles tendon CSA was detected between the two legs at any time point. Local tendon collagen synthesis, measured as the peritendinous concentrations of PINP (NH(2)-terminal propeptide of type I collagen; indirect marker for collagen synthesis), was unchanged after 2 wk of immobilization. However, peritendinous levels of PINP were significantly elevated in the immobilized leg (15 to 139 ng/ml) following 2 wk of remobilization compared with preimmobilization levels. In contradiction hereto, systemic concentrations of PINP remained unchanged throughout the study. Immobilization reduced muscle size and strength, while tendon size and collagen turnover were unchanged. While recovery resulted in an increase in muscle size, strength was unchanged. No significant difference in tendon size could be detected between the two legs after 2 wk of recovery, although collagen synthesis was increased in the previously immobilized leg. Thus 2 wk of immobilization are sufficient to induce significant changes in muscle tissue, whereas tendon tissue seems to be more resistant to short-term immobilization.  相似文献   

18.
It is well known that during maximal plantar flexion contractions the ankle joint rotation overestimates the actual elongation of the tendon and aponeurosis. The aim of this study was to examine the influence of the curve length changes of the Achilles tendon on the joint rotation corrected elongation and strain of the gastrocnemius medialis (GM) tendon and aponeurosis. Nine subjects (age: 29.4 ± 5.7 years, body mass: 78.8 ± 6.8 kg, body height: 178 ± 4 cm) participated in the study. The subjects performed maximal voluntary isometric plantarflexion contractions in the prone position on a Biodex-dynamometer. Ultrasonography (Aloka SSD 4000) was used to visualize the muscle belly of the GM muscle-tendon unit. To calculate the curve length changes of the Achilles tendon its surface contour was reconstructed using a series of small reflective skin markers having a diameter of 2.5 mm. The elongation of the GM tendon and aponeurosis was calculated (a) as the difference of the measured and the passive (due to joint rotation) displacement of the tendon and aponeurosis and (b) as the difference of the measured displacement and the length changes of the reconstructed Achilles tendon surface contour. The absolute difference between the elongation obtained by both methods were 1.2 ± 0.4 mm. These differences were due to the higher changes in length obtained by the reconstruction of the tendon curved surface contour as compared to the changes observed in the passive displacement of the digitised point at the aponeurosis. Without correcting for angle joint rotation, the measured elongation clearly overestimates the actual elongation of the GM tendon and aponeurosis. After the passive displacement correction the calculated elongation still overestimates the actual elongation of the GM tendon and aponeurosis. However, this overestimation has a negligible effect on the examined in vivo strain (0.3%) of the tendon and aponeurosis.  相似文献   

19.
Following surgical Achilles tendon reconstruction surgery, there is a distinct trend towards an early and faster rehabilitation protocol to avoid muscle atrophy. However, this procedure involves the risk of a higher complication rate. In order to reduce the occurrence of re-ruptures and pathological tendon extensions, a tendon reconstruction with the highest possible primary stability is desirable. Therefore, the aim of this study was to determine if augmentation using synthetic polyester tapes (QuadsTape™) could provide greater primary stability in case of different tendon suture techniques.90 tendons of the superficial toe flexor of pigs were divided into 9 groups. The reconstruction method was combined using the factors suture technique (Kessler and Bunnell), augmentation (non-augmented and augmented with QuadsTape™) and defect type (end-to-end and 10 mm gap). The biomechanical measurements were performed on a material testing machine and consisted of a creep test, a cyclic test and a tear-off test. This study compared creep strain, ultimate load failure, maximum stress and stiffness.Irrespective of the type of defect involved, augmentation of the tendon sutures led to a significant increase of the maximum force (not augmented: 82.30 ± 25.48 N, augmented: 135.73 ± 30.69 N, p < 0.001) and the maximum stress (not augmented: 2.26 ± 0.83 MPa, augmented: 4.13 ± 1.79 MPa, p < 0.001). Furthermore, there was a non-significant increase in stiffness and no significant differences were observed with respect to creep strain.Augmentation of Achilles tendon reconstruction using QuadsTape™ increases composite strength and stiffness in the in vitro model, thus potentially contributing to the feasibility of early rehabilitation programs. Biological factors still need to be investigated in order to formulate appropriate indications.  相似文献   

20.
Achilles tendon injuries affect both athletes and the general population, and their incidence is rising. In particular, the Achilles tendon is subject to dynamic loading at or near failure loads during activity, and fatigue induced damage is likely a contributing factor to ultimate tendon failure. Unfortunately, little is known about how injured Achilles tendons respond mechanically and structurally to fatigue loading during healing. Knowledge of these properties remains critical to best evaluate tendon damage induction and the ability of the tendon to maintain mechanical properties with repeated loading. Thus, this study investigated the mechanical and structural changes in healing mouse Achilles tendons during fatigue loading. Twenty four mice received bilateral full thickness, partial width excisional injuries to their Achilles tendons (IACUC approved) and twelve tendons from six uninjured mice were used as controls. Tendons were fatigue loaded to assess mechanical and structural properties simultaneously after 0, 1, 3, and 6 weeks of healing using an integrated polarized light system. Results showed that the number of cycles to failure decreased dramatically (37-fold, p<0.005) due to injury, but increased throughout healing, ultimately recovering after 6 weeks. The tangent stiffness, hysteresis, and dynamic modulus did not improve with healing (p<0.005). Linear regression analysis was used to determine relationships between mechanical and structural properties. Of tendon structural properties, the apparent birefringence was able to best predict dynamic modulus (R2=0.88–0.92) throughout healing and fatigue life. This study reinforces the concept that fatigue loading is a sensitive metric to assess tendon healing and demonstrates potential structural metrics to predict mechanical properties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号