首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundChikungunya virus (CHIKV) causes febrile illnesses and has always been misdiagnosed as other viral infections, such as dengue and Zika; thus, a laboratory test is needed. Serological tests are commonly used to diagnose CHIKV infection, but their accuracy is questionable due to varying degrees of reported sensitivities and specificities. Herein, we conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of serological tests currently available for CHIKV.Methodology and principal findingsA literature search was performed in PubMed, CINAHL Complete, and Scopus databases from the 1st December 2020 until 22nd April 2021. Studies reporting sensitivity and specificity of serological tests against CHIKV that used whole blood, serum, or plasma were included. QUADAS-2 tool was used to assess the risk of bias and applicability, while R software was used for statistical analyses.Thirty-five studies were included in this meta-analysis; 72 index test data were extracted and analysed. Rapid and ELISA-based antigen tests had a pooled sensitivity of 85.8% and 82.2%, respectively, and a pooled specificity of 96.1% and 96.0%, respectively. According to our meta-analysis, antigen detection tests serve as a good diagnostic test for acute-phase samples. The IgM detection tests had more than 90% diagnostic accuracy for ELISA-based tests, immunofluorescence assays, in-house developed tests, and samples collected after seven days of symptom onset. Conversely, low sensitivity was found for the IgM rapid test (42.3%), commercial test (78.6%), and for samples collected less than seven of symptom onset (26.2%). Although IgM antibodies start to develop on day 2 of CHIKV infection, our meta-analysis revealed that the IgM detection test is not recommended for acute-phase samples. The diagnostic performance of the IgG detection tests was more than 93% regardless of the test formats and whether the test was commercially available or developed in-house. The use of samples collected after seven days of symptom onset for the IgG detection test suggests that IgG antibodies can be detected in the convalescent-phase samples. Additionally, we evaluated commercial IgM and IgG tests for CHIKV and found that ELISA-based and IFA commercial tests manufactured by Euroimmun (Lübeck, Germany), Abcam (Cambridge, UK), and Inbios (Seattle, WA) had diagnostic accuracy of above 90%, which was similar to the manufacturers’ claim.ConclusionBased on our meta-analysis, antigen or antibody-based serological tests can be used to diagnose CHIKV reliably, depending on the time of sample collection. The antigen detection tests serve as a good diagnostic test for samples collected during the acute phase (≤7 days post symptom onset) of CHIKV infection. Likewise, IgM and IgG detection tests can be used for samples collected in the convalescent phase (>7 days post symptom onset). In correlation to the clinical presentation of the patients, the combination of the IgM and IgG tests can differentiate recent and past infections.  相似文献   

2.
BackgroundIn patients with hepatic cystic echinococcosis (CE), treatment effectiveness, outcomes, complications, and recurrence rate are controversial. Endocystectomy is a conservative surgical approach that adequately removes cyst contents without loss of parenchyma. This conservative procedure has been modified in several ways to prevent complications and to improve surgical outcomes. This systematic review aimed to evaluate the intraoperative and postoperative complications of endocysectomy for hepatic CE as well as the hepatic CE recurrence rate following endocystectomy.MethodsA systematic search was made for all studies reporting endocystectomy to manage hepatic CE in PubMed, Web of Science, and Cochrane CENTRAL databases. Study quality was assessed using the methodological index for non-randomized studies (MINORS) criteria and the Cochrane revised tool to assess risk of bias in randomized trials (RoB2). The random-effects model was used for meta-analysis and the arscine-transformed proportions were used to determine complication-, mortality-, and recurrence rates. This study is registered with PROSPERO (number CRD42020181732).ResultsOf 3,930 retrieved articles, 54 studies reporting on 4,058 patients were included. Among studies reporting preoperative anthelmintic treatment (31 studies), albendazole was administered in all of them. Complications were reported in 19.4% (95% CI: 15.9–23.2; I2 = 84%; p-value <0.001) of the patients; biliary leakage (10.1%; 95% CI: 7.5–13.1; I2 = 81%; p-value <0.001) and wound infection (6.6%; 95% CI: 4.6–9; I2 = 27%; p-value = 0.17) were the most common complications. The post-endocystectomy mortality rate was 1.2% (95% CI: 0.8–1.8; I2 = 21%; p-value = 0.15) and the recurrence rate was 4.8% (95% CI: 3.1–6.8; I2 = 87%; p-value <0.001). Thirty-nine studies (88.7%) had a mean follow-up of more than one year after endocystectomy, and only 14 studies (31.8%) had a follow-up of more than five years.ConclusionEndocystectomy is a conservative and feasible surgical approach. Despite previous disencouraging experiences, our results suggest that endocystectomy is associated with low mortality and recurrence.  相似文献   

3.
BackgroundNeurocysticercosis (NCC), and cystic echinococcosis (CE) are two neglected diseases caused by cestodes, co-endemic in many areas of the world. Imaging studies and serological tests are used in the diagnosis of both parasitic diseases, but cross-reactions may confound the results of the latter. The novel multiplex bead-based assay with recombinant antigens has been reported to increases the diagnostic accuracy of serological techniques.MethodologyWe set-up an immunoassay based on the multiplex bead-based platform (MBA), using the rT24H (against Cysticercus cellulosae, causing cysticercosis) and r2B2t (against Echinococcus granulosus sensu lato, causing CE) recombinant antigens, for simultaneous and differential diagnosis of these infections. The antigens were tested on 356 sera from 151 patients with CE, 126 patients with NCC, and 79 individuals negative for both diseases. Specificity was calculated including sera from healthy donors, other neurological diseases and the respective NCC or CE sera counterpart. The diagnostic accuracy of this assay was compared with two commercial ELISA tests, Novalisa and Ridascreen, widely used in the routine diagnosis of cysticercosis and CE, respectively.Main findingsFor the diagnosis of NCC, sensitivity ranged from 57.94–63.49% for the rT24H-MBA, and 40.48–46.03% for Novalisa ELISA depending on exclusion or inclusion of sera having equivocal results on ELISA from the analysis; specificities ranged from 90.87–91.30% and 70.43–76.96%, respectively. AUC values of the ROC curve were 0.783 (rT24H) and 0.619 (Novalisa) (p-value < 0.001). For the diagnosis of CE, the sensitivity of the r2B2t-MBA ranged from 68.87–69.77% and of Ridascreen ELISA from 50.00–57.62%; specificities from 92.47–92.68% and from 74.15–80.98%, respectively. AUC values were 0.717 and 0.760, respectively.Conclusions/SignificanceOverall, the recombinant antigens tested with the bead-based technology showed better diagnostic accuracy than the commercial assays, particularly for the diagnosis of NCC. The possibility of testing the same serum sample simultaneously for the presence of antibodies against both antigens is an added value particularly in seroprevalence studies for cysticercosis linked to control programs in endemic areas where these two parasites coexist.  相似文献   

4.
BackgroundCystic echinococcosis (CE) is a complex disease for which clear understanding of clinical manifestations is needed to avoid misdiagnosis, inappropriate treatment, and severe complications. We evaluated the accuracy of a whole-blood stimulation test based on Interleukin (IL)-4 detection in response to Antigen B (AgB) of Echinococcus granulosus sensu lato to discriminate cyst viability and detect cyst reactivation in patients with hepatic CE.Methodology/Principal findingsThirty patients with CE3b cysts and 37 patients with spontaneously-inactivated CE4-CE5 cysts were recruited (T0). After enrollment, 5 patients with CE3b cysts received albendazole, resulting in cyst solidification (CE4) in 4/5. Within a two-year follow-up, the whole-blood test was repeated at two time-points, in ≥14 (T1) and in ≥4 (T2) patients per group. IL-4 and a panel of other soluble factors were measured in the stimulated plasma.Baseline IL-4 levels were significantly higher in patients with CE3b compared to those with CE4 cysts (p = 0.006). Test accuracy for CE3b diagnosis had a sensitivity of 33–60% and a specificity of 76–95%, depending on the cut-off applied. Overall, IL-4 levels did not change significantly over time in either group; however, patients within the CE3b group showed a significant decrease of IL-1ra, IL-6, IL-8, G-CSF, IFN-γ, IP-10, MCP-1, MIP-1α, FGF at T1 compared to T0 (p≤0.042).Conclusions/SignificanceWhole-blood IL-4-response to AgB is significantly higher in patients with active compared to inactive CE but apparently not modulated over time after treatment. On the contrary, the levels of IL-1ra, IL-6, IL-8, G-CSF, IFN-γ, IP-10, MCP-1, MIP-1α, FGF significantly decreased in active CE during follow-up. Additional studies are needed to understand whether these findings might have a clinical significance for patients’ follow-up.  相似文献   

5.
Background and aimsHepatic steatosis is the most common histopathological finding on liver biopsy, with the most prevalent etiology being NAFLD. The pathogenesis of hepatic steatosis and NAFLD is multifactorial, however, studies on the importance of manganese in NAFLD are limited. We aimed to study hepatic manganese content, and other trace elements, in relation to hepatic steatosis in patients with chronic liver diseases of different etiology, mainly NAFLD.MethodsPatients with chronically elevated liver function tests underwent a diagnostic work-up, including routine blood tests and two liver biopsies. One of the biopsies was sent for histopathological evaluation, and the other for ultra-trace elemental determinations. Steatosis was graded using conventional histopathological methodology, and fat content was also quantitated in biopsy samples by measuring the steatotic area of the section using stereological point counting (SPC). Ultra-trace elemental analysis was utilized for determining manganese, iron, and copper using inductively coupled plasma sector field mass spectrometry (ICP-SFMS).Results76 patients were included in the study. Hepatic manganese concentrations in patients with steatosis were lower than in patients without hepatic steatosis (3.8 ± 1.1 vs. 6.4 ± 1.8, P < 0.001). Similar results were seen for blood manganese levels and hepatic steatosis. We found a strong inverse correlation between steatosis grade and hepatic manganese content (ρ=-0.743, P < 0.001). Also, low levels of manganese independently predicted the presence of steatosis (aOR 0.07 [95%CI: 0.01−0.63]).ConclusionPatients with NAFLD, or other CLD and concomitant hepatic steatosis, showed lower levels of hepatic manganese content with increasing grade of steatosis.  相似文献   

6.
IntroductionCongenital infection caused by Toxoplasma gondii can cause serious damage that can be diagnosed in utero or at birth, although most infants are asymptomatic at birth. Prenatal diagnosis of congenital toxoplasmosis considerably improves the prognosis and outcome for infected infants. For this reason, an assay for the quick, sensitive, and safe diagnosis of fetal toxoplasmosis is desirable.GoalTo systematically review the performance of polymerase chain reaction (PCR) analysis of the amniotic fluid of pregnant women with recent serological toxoplasmosis diagnoses for the diagnosis of fetal toxoplasmosis.MethodA systematic literature review was conducted via a search of electronic databases; the literature included primary studies of the diagnostic accuracy of PCR analysis of amniotic fluid from pregnant women who seroconverted during pregnancy. The PCR test was compared to a gold standard for diagnosis.ResultsA total of 1.269 summaries were obtained from the electronic database and reviewed, and 20 studies, comprising 4.171 samples, met the established inclusion criteria and were included in the review. The following results were obtained: studies about PCR assays for fetal toxoplasmosis are generally susceptible to bias; reports of the tests’ use lack critical information; the protocols varied among studies; the heterogeneity among studies was concentrated in the tests’ sensitivity; there was evidence that the sensitivity of the tests increases with time, as represented by the trimester; and there was more heterogeneity among studies in which there was more time between maternal diagnosis and fetal testing. The sensitivity of the method, if performed up to five weeks after maternal diagnosis, was 87% and specificity was 99%.ConclusionThe global sensitivity heterogeneity of the PCR test in this review was 66.5% (I2). The tests show low evidence of heterogeneity with a sensitivity of 87% and specificity of 99% when performed up to five weeks after maternal diagnosis. The test has a known performance and could be recommended for use up to five weeks after maternal diagnosis, when there is suspicion of fetal toxoplasmosis.  相似文献   

7.
《Endocrine practice》2008,14(4):465-469
ObjectiveTo describe a case of thyroglossal duct cyst carcinoma that arose in a patient with right thyroid lobe hemiagenesis.MethodsWe present the imaging, physical examination findings, treatment, and clinical course of the study patient.ResultsA 35-year-old woman was evaluated for a neck mass that had been present for 6 months and was slowly growing. She reported a previous diagnosis of right hemithyroid agenesis. The patient’s preoperative workup included ultrasonography of the neck and head and neck T1- and T2-weighted magnetic resonance imaging, which showed right hemithyroid agenesis and a cystic lesion in the median region of the neck below the hyoid bone. Findings from chest x-rays and thyroid function tests were normal. The patient underwent a modified Sistrunk procedure that included removal of the median portion of the hyoid bone. Histologic findings showed a 2.5-cm thyroglossal duct cyst with a 0.6-cm focus of follicular variant of papillary carcinoma with invasion of the cyst wall. Total thyroidectomy was not performed because of the absence of tumoral invasion of the parenchyma around the thyroglossal duct cyst and because the patient was at low risk for aggressive disease. Cervical ultrasonography examinations were performed 6, 12, and 24 months after treatment, and all findings were normal. Presently, the patient is symptom-free after 4 years of follow-up and has no evidence of disease.ConclusionIncidentally discovered, well-differentiated thyroid cancer that is confined to a thyroglossal duct cyst in a patient at low risk for aggressive disease can be adequately treated by a modified Sistrunk procedure that includes the median portion of the hyoid bone. (Endocr Pract. 2008;14:465-469)  相似文献   

8.

Object

The aim of this study was to determine the suitability of magnetic resonance spectroscopy (MRS) for screening brain tumors, based on a systematic review and meta-analysis of published data on the diagnostic performance of MRS.

Methods

The PubMed and PHMC databases were systematically searched for relevant studies up to December 2013. The sensitivities and specificities of MRS in individual studies were calculated and the pooled diagnostic accuracies, with 95% confidence intervals (CI), were assessed under a fixed-effects model.

Results

Twenty-four studies were included, comprising a total of 1013 participants. Overall, no heterogeneity of diagnostic effects was observed between studies. The pooled sensitivity and specificity of MRS were 80.05% (95% CI = 75.97%–83.59%) and 78.46% (95% CI: 73.40%–82.78%), respectively. The area under the summary receiver operating characteristic curve was 0.78. Stratified meta analysis showed higher sensitivity and specificity in child than adult. CSI had higher sensitivity and SV had higher specificity. Higher sensitivity and specificity were obtained in short TE value.

Conclusion

Although the qualities of the studies included in the meta-analysis were moderate, current evidence suggests that MRS may be a valuable adjunct to magnetic resonance imaging for diagnosing brain tumors, but requires selection of suitable technique and TE value.  相似文献   

9.

Background

Serological (antibody detection) tests for tuberculosis (TB) are widely used in developing countries. As part of a World Health Organization policy process, we performed an updated systematic review to assess the diagnostic accuracy of commercial serological tests for pulmonary and extrapulmonary TB with a focus on the relevance of these tests in low- and middle-income countries.

Methods and Findings

We used methods recommended by the Cochrane Collaboration and GRADE approach for rating quality of evidence. In a previous review, we searched multiple databases for papers published from 1 January 1990 to 30 May 2006, and in this update, we add additional papers published from that period until 29 June 2010. We prespecified subgroups to address heterogeneity and summarized test performance using bivariate random effects meta-analysis. For pulmonary TB, we included 67 studies (48% from low- and middle-income countries) with 5,147 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (31% to 100%). For anda-TB IgG, the only test with enough studies for meta-analysis, pooled sensitivity was 76% (95% CI 63%–87%) in smear-positive (seven studies) and 59% (95% CI 10%–96%) in smear-negative (four studies) patients; pooled specificities were 92% (95% CI 74%–98%) and 91% (95% CI 79%–96%), respectively. Compared with ELISA (pooled sensitivity 60% [95% CI 6%–65%]; pooled specificity 98% [95% CI 96%–99%]), immunochromatographic tests yielded lower pooled sensitivity (53%, 95% CI 42%–64%) and comparable pooled specificity (98%, 95% CI 94%–99%). For extrapulmonary TB, we included 25 studies (40% from low- and middle-income countries) with 1,809 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (59% to 100%). Overall, quality of evidence was graded very low for studies of pulmonary and extrapulmonary TB.

Conclusions

Despite expansion of the literature since 2006, commercial serological tests continue to produce inconsistent and imprecise estimates of sensitivity and specificity. Quality of evidence remains very low. These data informed a recently published World Health Organization policy statement against serological tests. Please see later in the article for the Editors'' Summary  相似文献   

10.
BackgroundReliable and field-applicable diagnosis of schistosome infections in non-human animals is important for surveillance, control, and verification of interruption of human schistosomiasis transmission. This study aimed to summarize uses of available diagnostic techniques through a systematic review and meta-analysis.Methodology and principal findingsWe systematically searched the literature and reports comparing two or more diagnostic tests in non-human animals for schistosome infection. Out of 4,909 articles and reports screened, 19 met our inclusion criteria, four of which were considered in the meta-analysis. A total of 14 techniques (parasitologic, immunologic, and molecular) and nine types of non-human animals were involved in the studies. Notably, four studies compared parasitologic tests (miracidium hatching test (MHT), Kato-Katz (KK), the Danish Bilharziasis Laboratory technique (DBL), and formalin-ethyl acetate sedimentation-digestion (FEA-SD)) with quantitative polymerase chain reaction (qPCR), and sensitivity estimates (using qPCR as the reference) were extracted and included in the meta-analyses, showing significant heterogeneity across studies and animal hosts. The pooled estimate of sensitivity was 0.21 (95% confidence interval (CI): 0.03–0.48) with FEA-SD showing highest sensitivity (0.89, 95% CI: 0.65–1.00).Conclusions/significanceOur findings suggest that the parasitologic technique FEA-SD and the molecular technique qPCR are the most promising techniques for schistosome diagnosis in non-human animal hosts. Future studies are needed for validation and standardization of the techniques for real-world field applications.  相似文献   

11.
BackgroundLeukoaraiosis is common in patients with acute ischemic stroke. The results from many studies investigating the association between leukoaraiosis and intracranial hemorrhage after thrombolysis remain conflicting.MethodsA meta-analysis was performed to compare the risk of post-thrombolytic intracranial hemorrhage in patients with and without leukoaraiosis. Relevant reports were identified by searching PubMed, EmBase, Cochrane Library, and ISI Web of Science through December 2015 using a combination of subjective and random terms. Eligible studies that were original articles with a clear definition of leukoaraiosis and intracranial hemorrhage were selected and analyzed. Funnel plots, Egger’s test, and Begg’s test were conducted to assess the publication bias. Sensitivity analysis was also performed to evaluate the influence of each individual study.ResultsEleven trials that enrolled 6912 participants were included. There was a significantly increased risk for acute ischemic stroke patients with leukoaraiosis (odds ratio: 1.89, 95% confidence interval 1.51–2.37, P<0.001). Low heterogeneity and less publication bias was detected among these studies. The results of both computed tomography and magnetic resonance imaging performed on the subgroups of leukoaraiosis were significant. Furthermore, an association between leukoaraiosis and symptomatic intracranial hemorrhage was also confirmed. The odds ratios remained stable with no obvious variations on the sensitivity analysis. The limitations consisted of types of including trials and not matching some baseline variables.ConclusionsThe results of this meta-analysis show that leukoaraiosis approximately doubles the incidence of intracranial hemorrhage after thrombolytic therapy. However, it does not critically affect decision making regarding thrombolysis for patients with acute ischemic stroke. Additional investigations are required.  相似文献   

12.
Many serological tests are widely used in the diagnosis of cystic echinococcosis (CE), caused by the larval stages of Echinococcus granulosus. The present study was carried for differentiation between hepatic and pulmonary cystic echinococcosis by Western Blotting (WB). A total of 121 sera from patients with hepatic CE (37), pulmonary CE (31) and controls (53; consisting of six healthy, seven Hymenolepis nana infection, 20 hepatic and 20 pulmonary diseases other than CE) were examined. In all of the CE patients, E. gronulosus infection was confirmed by surgical intervention. Sera were previously tested using IHA and ELISA to detect the E. gronulosus specific antibodies. Sera from hepatic cases of CE reacted with 16 polypeptides of 6-116 kDa and sera from pulmonary cases of CE reacted with 14 polypeptides of 4-130 kDa by Western Blotting. The WB test enabled the detection of antibodies in the hepatic CE samples for proteins of 24, 32 34, 44-46 and 52-54 kDa in molecular weight in 78.4%, 75.7%, 78.4% and 89.2% of the patients, respectively. In the pulmonary CE samples sera WB test enabled the detection of antibodies 24, 44-46, 100, 110, 116 and 120 124 kDa in molecular weight in 81.3%, 75.0%, 87.5%, 71.9%, 84.4% and 65.6% of the patients, respectively. We indicated that the antigenic components of high molecular weight can be good candidates for differentiation of hepatic CE from pulmonary CE.  相似文献   

13.
BackgroundThe benefit of repeat hepatectomy in patients with early recurrence of colorectal cancer liver metastases (CRLM) is questioned, in particular in those suffering from recurrence within three to six months following initial hepatectomy. The aim of this review was therefore to assess whether disease-free interval was associated with overall survival in patients undergoing repeat hepatectomy for recurrent CRLM.MethodsA systematic review and meta-analysis was conducted, according to PRISMA guidelines. PubMed, Embase and Cochrane Library databases were searched from database inception to 6th June 2020. Observational studies describing results of repeat hepatectomy for recurrent CRLM, including (disease-free) interval between hepatic resections and overall survival were included. Patients undergoing repeat hepatectomy within three months or additional resection of extrahepatic disease were excluded from meta-analysis.ResultsThe initial search identified 2159 records, of which 28 were included for qualitative synthesis. A meta-analysis of 15 cohort studies was performed, comprising 1039 eligible patients. Median overall survival of 54.0 months [95 %-CI: 38.6–69.4] was observed after repeat hepatectomy in patients suffering from recurrent CRLM between three to six months compared to 53.0 months [95 %-CI: 44.3–61.6] for patients with recurrent CRLM between seven to twelve months (adjusted HR = 0.89, 95 %-CI: 0.66–1.18; p = 0.410), and 60.0 months [95 %-CI: 52.7–67.3] for patients with recurrent CRLM after twelve months (adjusted HR = 0.70, 95 %-CI: 0.53−0.92; p = 0.012).ConclusionsDisease-free interval is considered a prognostic factor for overall survival, but should not be used as selection criterion per se for repeat hepatectomy in patients suffering from recurrent CRLM.  相似文献   

14.
New candidates for serological markers against leishmaniasis are required to be identified, since the presence of high titers of anti-Leishmania antibodies remain detected in sera of treated and cured patients, when current antigens have being employed. In this study, the diagnostic performance of a conserved Leishmania hypothetical protein was evaluated against a human and canine serological panel. The serological follow-up of the patients was also evaluated, using this recombinant antigen (rLiHyS) in ELISA assays. In the results, high sensitivity and specificity values were found when rLiHyS was used in the serological tests, while when the recombinant A2 (rA2) protein or an antigenic Leishmania preparation were used as controls, low sensitivity and specificity were found. Regarding the serological follow-up of the patients, significant reductions in the anti-rLiHyS antibody levels were found and, one year after the treatments, the anti-protein IgG production was similar to this found in the non-infected groups, reflecting a drop of the anti-rLiHyS antibody production. In conclusion, the present study shows for the first time a new recombinant antigen used to identify tegumentary and visceral leishmaniasis, as well as being able to serologically distinguish treated and cured patients from those developing active disease.  相似文献   

15.
Cystic echinococcosis (CE) is a neglected zoonotic disease caused by Echinococcus granulosus sensu lato. Diagnosis and monitoring of CE rely primarily on imaging while serology is used as a confirmatory test. However, imaging is not always conclusive and currently available serological assays have suboptimal sensitivity and specificity, lack standardization, and are not useful for patients´ follow-up. Seroassays for CE are usually based on hydatid fluid (HF), a complex, variable antigenic mixture, and cross-reactivity exists especially with alveolar echinococcosis. Recombinant proteins based on immunogenic antigens most abundant in HF, such as AgB1, AgB2 and Ag5, have been used to overcome these limitations. None of them so far showed potential to replace HF; however, their performance have been largely tested on a limited number of samples, and comparison of different antigens using the same cohort has been rarely performed. The combination of several immunogenic epitopes in a single recombinant protein could enhance test sensitivity. For the diagnosis and follow-up of patients with CE, we compared the performance of the crude HF, previously described recombinant 2B2t antigen, and GST-tagged version of 2B2t, and novel designed recombinants (GST-Ag5t and the GST-DIPOL chimera containing AgB1, AgBB2 and Ag5 epitopes) by IgG-ELISA format. Samples belong to a retrospective cohort of 253 well-characterized patients with CE, previously described for the evaluation of the 2B2t antigen, 92 patients with alveolar echinococcosis, and 82 healthy donors. The reference standard for CE diagnosis was the presence of a CE lesion as diagnosed by ultrasonography. The highest sensitivity was obtained with HF [86.7%, 95% confidence interval (CI): 81.2–91.0], followed by GST-2B2t (70.0%, 95% CI: 63.1–76.2), 2B2t (65.5%, 95% CI: 58.5–72.0), GST-Ag5t (64.5%, 95% CI: 57.5–71.1) and GST-DIPOL (63.1%, 95% CI: 56.0–69.7). The GST-2B2t had the best specificity (95.8%, 95% CI: 88.3–99.1) and the lowest cross-reactivity (38.7%, 95% CI: 27.6–50.6). Good response to treatment also correlated to negative test results in the GST-2B2t ELISA. While none of the tested recombinant antigen appears suitable to replace HF for the diagnosis of CE, GST-2B2t should be further explored as a confirmation test, based on its high specificity and low cross-reactivity, and for the follow-up after treatment in those patients with positive serology for this antigen.  相似文献   

16.
BackgroundNeonatal sepsis (NS) is a life-threatening disorder and an important cause of morbidity and mortality in neonates. Previous studies showed that interleukin 8 (IL-8) may effectively and rapidly diagnose NS.ObjectiveWe conducted the systematic review and meta-analysis to investigate the diagnostic value of the IL-8 in NS.MethodsThe literature was searched in PUBMED, EMBASE, Cochrane Library, CNKI, VIP and other Chinese Medical Databases during October 1998 to January 2014 using set search criteria. Each included study was evaluated by quality assessment of diagnostic accuracy studies tool. Two investigators independently extracted the data and study characteristics, and disagreements, if any, were resolved by consensus. Meta-disc software was used to calculate the pooled sensitivity, specificity and summary diagnostic odds ratio (SDOR), I² or Cochrane Q to test heterogeneity, and meta-regression to investigate the source of heterogeneity. Funnel plots were used to test the potential presence of publication bias. False-positive report probability (FPRP) was calculated to confirm the significance of the results.ResultsEight studies (548 neonates) were included in this meta-analysis. The pooled sensitivity and specificity of IL-8 were 0.78 and 0.84, respectively, which had moderate accuracy in the diagnosis of NS. The pooled diagnostic odds ratio (DOR) and area under curve (AUC) was 21.64 and 0.8908 (Q*=0.8215), respectively. The diagnostic threshold analysis showed that there was no threshold effect. The meta-regression analysis showed the cut-off, QUADAS and onset time have no effect on the heterogeneity. The funnel plots showed the existence of publication bias.ConclusionMeta-analysis showed IL-8 had a moderate accuracy (AUC=0.8908) for the diagnosis of NS. IL-8 is a helpful biomarker for early diagnosis of NS. However, we should combine the results with clinical symptoms and signs, laboratory and microbial results.  相似文献   

17.
Cystic echinococcosis (CE) is the larval cystic stage (called echinococcal cysts) of a small taeniid-type tapeworm (Echinococcus granulosus). Carnivores such as dogs are usually definitive hosts. Intermediate hosts are typically herbivores such as sheep and cattle. CE can be detected using various imaging techniques such as ultrasonography or radiology. Moreover the primary diagnosis has to be confirmed by serological tests since the clinical signs of the disease are non-specific. This study examined the antigenic band patterns useful for serologic diagnosis of hydatidosis. We also report on the post-operative evolution of patients treated for this disease and also determined the diagnostic performance of Western blot IgG kit. Twenty-five (16 females and 9 males) non-operated patients with hydatid cysts (NOP) and 33 (21 females and 12 males) operated patients with hydatid cysts (OP) were included as study group and 22 healthy individuals (14 females and 8 males) with no known chronic diseases were included as a control group. The ages of the patients and control group individuals were between 16-83 years. Patient and control groups were matched for age and sex. Cyst hydatid IgG antibodies were detected in the sera from all patient groups but no antibodies were found in the sera from the control group using ELISA IgG method. Twenty-three (92%) non-operated patients and 18 (54.5%) operated patients exhibited positive results when Western blot IgG kit was used. The P7 band pattern was detected in the sera from all operated and non-operated patients. Twenty-seven of these positive cases had p7 and (p7+p16/18), (p7+p24/26) or (p7+p16/18+p24/26). No antibodies against p7, p16/18 ve p24/26 band patterns were seen in sera from the control group A statistically significant difference was detected between operated and nonoperated patients for Western blot positivity.(p<0.01). p: 0.018- X2=5,604- OR: 0.176- 95% CI: 0.037- 0.841. The sensitivity, specificity, positive prediction and negative prediction values of Echinococcus granulosus Western blot kit for 25 cases with CE and 22 healthy controls were calculated as 92%, 100%, 100% and 91.7%, respectively. In conclusion, we suggest that monitoring p7 in all non-operated patients may be useful to determine the efficiacy of medical treatment and that monitoring p7 antibodies using serological and Western blot methods in operated patients may be useful for the screening of post-operative evolution in patients with hydatid cyst.  相似文献   

18.

Background

Culture remains the diagnostic gold standard for many bacterial infections, and the method against which other tests are often evaluated. Specificity of culture is 100% if the pathogenic organism is not found in healthy subjects, but the sensitivity of culture is more difficult to determine and may be low. Here, we apply Bayesian latent class models (LCMs) to data from patients with a single Gram-negative bacterial infection and define the true sensitivity of culture together with the impact of misclassification by culture on the reported accuracy of alternative diagnostic tests.

Methods/Principal Findings

Data from published studies describing the application of five diagnostic tests (culture and four serological tests) to a patient cohort with suspected melioidosis were re-analysed using several Bayesian LCMs. Sensitivities, specificities, and positive and negative predictive values (PPVs and NPVs) were calculated. Of 320 patients with suspected melioidosis, 119 (37%) had culture confirmed melioidosis. Using the final model (Bayesian LCM with conditional dependence between serological tests), the sensitivity of culture was estimated to be 60.2%. Prediction accuracy of the final model was assessed using a classification tool to grade patients according to the likelihood of melioidosis, which indicated that an estimated disease prevalence of 61.6% was credible. Estimates of sensitivities, specificities, PPVs and NPVs of four serological tests were significantly different from previously published values in which culture was used as the gold standard.

Conclusions/Significance

Culture has low sensitivity and low NPV for the diagnosis of melioidosis and is an imperfect gold standard against which to evaluate alternative tests. Models should be used to support the evaluation of diagnostic tests with an imperfect gold standard. It is likely that the poor sensitivity/specificity of culture is not specific for melioidosis, but rather a generic problem for many bacterial and fungal infections.  相似文献   

19.
The antigenic structure of four aquatic Phycomycetes of the genusSaprolegnia with parasitic activity in fish was analyzed with immunoelectrophoresis and double diffusion techniques. It is shown that these serological tests might represent a valuable criterion for the identification of the fourSaprolegnia species:S. parasitica, S. ferax, S. delica, andS. diclina. A specific chromogenic reaction revealed the presence of a protease with chymotrypsin-like activity among the precipitation arcs obtained after immunoelectrophoresis. Analysis of this proteolytic activity by kinetic assay methods confirmed the results of the serological tests. Moreover estimates of the quantity of enzyme present in the cellular extract and in the culture medium were obtained. A possible relationship between the proteolytic activity and the host-parasite interaction was discussed.  相似文献   

20.
《Genomics》2020,112(2):1889-1896
BackgroundThe aim of this meta-analysis was to explore associations between polymorphisms in CTLA-4/IL-18 and chronic liver diseases by combing the results of all relevant studies.MethodsEligible studies were searched from Pubmed, Embase, Web of Science and Cochrane library. We used Review Manager to combine the results of eligible studies.ResultsSixty-seven studies were included in this meta-analysis. Combined results revealed that CTLA-4 rs231775 (dominant, recessive and allele comparisons), IL-18 rs1946518 (dominant, recessive and allele comparisons) and IL-18 rs187238 (dominant, over-dominant and allele comparisons) polymorphisms were all significantly associated with chronic liver diseases in the overall population. We also obtained similar positive results for rs231775, rs5742909, rs3087243, rs1946518 and rs187238 polymorphisms in subgroup analyses by ethnicity and type of disease.ConclusionsThis meta-analysis demonstrated that CTLA-4 rs231775, CTLA-4 rs5742909, CTLA-4 rs3087243, IL-18 rs1946518 and IL-18 rs187238 polymorphisms may confer susceptibility to certain types of chronic liver diseases.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号