首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The aim of this study was to evaluate the performance of commercially available anti-HIV assays when testing plasma, urine and oral mucosal transudate (OMT) samples for the presence of antibodies to HIV. Homologous sets of plasma, urine and oral mucosal transudate specimens were collected from 288 hospitalized patients in northern Tanzania and tested for antibodies to HIV using a routine enzyme immunoassay (Recombinant 3rd Generation EIA, Abbott) and two rapid assays (Testpack HIV-1/HIV-2; Abbott and SUDS HIV-1, Murex). Incubation times and/or sample volumes when testing OMT or urine were increased as compared to those recommended for plasma. The corresponding plasma specimens from all repeatedly reactive samples and samples presenting discordant results were subjected to confirmational testing by an HIV-1/2 Western blot. A total of 15.3% (44/288) of the plasma samples were anti-HIV-1 positive by Western blot. The sensitivity using plasma was 100% by all assays, 69.7-97.7% using urine, and 92.7-100% using oral transudate specimens. The sensitivity of both rapid assays was excellent and higher than the EIA when testing OMT. Specificities ranged from 98.8-100% for plasma, 99-100% for urine and were 100% by all assays using oral samples. The results obtained using oral mucosal transudate specimens and rapid assays were at least comparable to those obtained with plasma, while the use of urine specimens produced suboptimal sensitivities with two of the three assays. The testing of alternative body fluids for antibodies to HIV is yet another strategy that may be applicable, particularly in developing countries.  相似文献   

2.

Background

New rapid point-of-care (POC) tests are being developed that would offer the opportunity to increase screening and treatment of several infections, including syphilis. This study evaluated three of these new rapid POC tests at a site in Southern California.

Methods

Participants were recruited from a testing center in Long Beach, California. A whole blood specimen was used to evaluate the performance of the Dual Path Platform (DPP) Syphilis Screen & Confirm, DPP HIV-Syphilis, and DPP HIV-HCV-Syphilis rapid tests. The gold-standard comparisons were Treponema pallidum passive particle agglutination (TPPA), rapid plasma reagin (RPR), HCV enzyme immunoassay (EIA), and HIV-1/2 EIA.

Results

A total of 948 whole blood specimens were analyzed in this study. The sensitivity of the HIV tests ranged from 95.7–100% and the specificity was 99.7–100%. The sensitivity and specificity of the HCV test were 91.8% and 99.3%, respectively. The treponemal-test sensitivity when compared to TPPA ranged from 44.0–52.7% and specificity was 98.7–99.6%. The non-treponemal test sensitivity and specificity when compared to RPR was 47.8% and 98.9%, respectively. The sensitivity of the Screen & Confirm test improved to 90.0% when cases who were both treponemal and nontreponemal positive were compared to TPPA+/RPR ≥1∶8.

Conclusions

The HIV and HCV on the multi-infection tests showed good performance, but the treponemal and nontreponemal tests had low sensitivity. These results could be due to a low prevalence of active syphilis in the sample population because the sensitivity improved when the gold standard was limited to those more likely to be active cases. Further evaluation of the new syphilis POC tests is required before implementation into testing programs.  相似文献   

3.

Background

Co-infection with hepatitis B virus (HBV) is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg) before initiation of combination antiretroviral therapy (cART) is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV) infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania.

Methods

Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO) in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA.

Results

Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32–47), 169/272 (63%) subjects were females and median CD4+ count was 250 cells/µL (IQR 97–439). HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2–13.0%) subjects. Of these, 7/25 (28%) were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8–99.6%) and specificity at 100% (95% CI, 98.9–100%). Antibodies to HCV (anti-HCV) were found in 10/272 (3.7%, 95% CI 2.0–6.4%) of patients.

Conclusion

This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.  相似文献   

4.
A team at the Colombian National Institute of Health (INS) has demonstrated the usefulness and suitability of the Immunofluorescent Antibody Test (IFAT) as a confirmatory assay for HIV-1. The assay followed a flow chart method recommended by the Pan American Health Organization (PAHO) and the Federal Center for AIDS of Canada. The specificity of the IFAT assay (IFI-VIH1-INS) for 925 serum samples was 100% when compared with two different Western blot (WB) assays. The IFI-VIH1-INS showed a sensitivity of 61% across 6,137 human sera. Although its specificity is excellent, the sensitivity of the IFI-VIH1-INS assay is slightly lower than other IFAT assays (41% of 975 samples were indeterminate in both IFAT assays and WB tests). After implementation of this assay in more than 6,000 serum samples between 1993 and 2000, the INS saved more than Col $340,000,000 or US $170.000 in its HIV1 testing program.  相似文献   

5.
Background: Diagnosis of acute and past infection with parvovirus B19 is based on detection of IgM and IgG antibodies.Objectives: To evaluate two commercial recombinant antigen-based enzyme immunoassay (EIA) test kits for detection of IgM and IgG antibodies to parvovirus B19 and to compare the commercial EIAs to in-house EIA test procedures.Study design: A panel of 121 sera was used to compare the three IgM EIAs. The panel included 84 sera submitted for parvovirus B19 testing and 37 sera that were IgM positive for other viral pathogens. The same serum panel plus an additional 14 sera submitted for B19 testing was used to compare the three IgG EIAs. The commercial EIAs were performed according to manufacturers' instructions. Using the in-house EIA test procedures as the reference, sensitivity and specificity for each of the commercial EIAs was determined.Results: The commercial B19 IgM EIAs showed agreements of 95.0 and 93.4% to the in-house IgM EIA. Compared to the in-house B19 IgM EIA, the commercial B19 IgM EIAs, were 97.4 and 97.5% sensitive, respectively. Specificities were 93.5 and 91.4%, respectively. Sensitivities for the commercial IgG EIAs, compared to in-house IgG EIA, were 88.0 and 85.2%, respectively, and specificities were 94.1 and 98.0%.Conclusion: We found that the commercial parvovirus B19 IgM and IgG EIAs are comparable to standard in-house EIAs and are suitable for testing for B19 antibodies in human sera.  相似文献   

6.
In the present study, a sensitive and competitive chemiluminescence immunoassay (CLIA) was developed in order to detect human serum albumin (HSA) in urine specimen. The method utilizes a home-made monoclonal anti-albumin antibody conjugated to horseradish peroxidase enzyme (mAb-HRP). Sensitivity, specificity and linearity of the assay were evaluated. According to the results, the proper concentration of HSA and mAb-HRP conjugates was 800?ng/100?μl and 1:200 respectively. In optimal conditions, this method could detect HSA in a high linear range of 10–200?μg?ml?1 with the low detection limit of 0.025?μg?ml?1. No evidence of interference with presence of probable substances in the urine samples indicated its high specificity and selectivity. Moreover, high reproducibility as well as high sensitivity and specificity of the test were confirmed using diabetic and non-diabetic samples. Significant concordance was observed between CLIA and immunoturbidimetry assay regarding detection of HSA. The results of the present study can be considered in accordance with the current demands such as reliability, accuracy, convenience and high speed of performance for a precise protein detection method. Furthermore, it may be regarded as a more rapid, simpler and cheaper alternative compared to other sophisticated assays.  相似文献   

7.
A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.  相似文献   

8.
At least 10 million individuals worldwide are co-infected with immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV). These two viruses are transmitted most primarily by exposure to infected blood or blood products. Various nucleic acid assays have been developed for diagnostics and therapeutic monitoring of infections. In the present study, a multiplex real-time PCR assay for simultaneous detection of HCV and HIV-1 using molecular beacons were designed and validated. A well-conserved region in the HIV-1 pol gene and 5′NCR of HCV genome were used for primers and molecular beacon design. The analysis of scalar concentrations of the samples indicated that this multiplex procedure detects at least 1,000 copies/ml of HIV-1 and 100 copies/ml of HCV with linear reference curve (R 2 > 0.94). The results demonstrate that a specificity of 100 % and sensitivity of 96 % can be achieved. The analytical sensitivity study with BLAST software demonstrated that the primers do not attach to any other sequences except for that of HIV-1 or HCV. The primers and molecular beacon probes only detected HIV-1 and all major variants of HCV. This assay may represent an alternative rapid and relatively inexpensive screening method for detection of HIV-1/HCV co-infection especially in blood screening.  相似文献   

9.
A novel series of acetamide-substituted derivatives and two prodrugs of doravirine were designed and synthesized as potent HIV-1 NNRTIs by employing the structure-based drug design strategy. In MT-4 cell-based assays using the MTT method, it was found that most of the new compounds exhibited moderate to excellent inhibitory potency against the wild-type (WT) HIV-1 strain with a minimum EC50 value of 54.8?nM. Among them, the two most potent compounds 8i (EC50?=?59.5?nM) and 8k (EC50?=?54.8?nM) displayed robust activity against WT HIV-1 with double-digit nanomolar EC50 values, being superior to lamivudine (3TC, EC50?=?12.8?μM) and comparable to doravirine (EC50?=?13?nM). Besides, 8i and 8k shown moderate activity against the double RT mutant (K103N?+?Y181C) HIV-1 RES056 strain. The HIV-1 RT inhibition assay further validated the binding target. Molecular simulation of the representative compounds was employed to provide insight on their structure-activity relationships (SARs) and direct future design efforts. Finally, the aqueous solubility and chemical stability of the prodrugs 9 and 10 were investigated in detail.  相似文献   

10.
《Endocrine practice》2015,21(2):158-164
ObjectiveOur study aimed to establish a local reference range for late-night salivary Cortisol (LNSC) using enzyme immunoassay (EIA) and to study the intra-individ-ual reproducibility of LNSC.MethodsProspective study involving 30 healthy subjects (HS) with body mass index (BMI) < 25 kg/m2, 37 obese/overweight subjects (OS) with BMI > 25 kg/m2 and 28 patients with Cushing disease (CD). Salivary sampling was performed on 2 consecutive nights and assayed by EIA. The reference range was established using LNSC values of HS, and receiver operating characteristic (ROC) curves were used to determine diagnostic cutoffs.ResultsThe mean LNSC level of CD was significantly higher than HS and OS (CD: 16.96 ± 9.11nmol/L, HS: 1.30 ± 0.95 nmol/L, and OS 1.21 ± 0.78 nmol/L). A cutoff of 2.92 nmol/L differentiated CD from HS with 100% sensitivity and 96.7 % specificity, and a cutoff of 5.04 nmol/L yielded a specificity of 100% with a sensitivity of 96.4% to distinguish CD from OS. There was more intra-individual variability in HS (55%) than in CD (49%) and OS (22%). There was no difference in the sensitivity and specificity derived from the ROCs using day 1 values or the higher of the 2 LNSCs.ConclusionsIn our cohort, we found that LNSC assayed by EIA showed good sensitivity and specificity to screen patients suspected to have CD. Although intra-individual variability was significant, it did not hamper the diagnostic performance of the test. (Endocr Pract. 2015; 21:158-164)  相似文献   

11.

Background

Human Immunodeficiency Virus Type 1 (HIV-1) viral load testing at regular intervals is an integral component of disease management in Acquired Immunodeficiency Syndrome (AIDS) patients. The need in countries like India is therefore an assay that is not only economical but efficient and highly specific for HIV-1 sub type C virus. This study reports a SYBR Green-based HIV-1 real time PCR assay for viral load testing and is designed for enhanced specificity towards HIV-1 sub type C viruses prevalent in India.

Results

Linear regression of the observed and reference concentration of standards used in this study generated a correlation coefficient of 0.998 (p < 0.001). Lower limit of detection of the test protocol was 50 copies/ml of plasma. The assay demonstrated 100% specificity when tested with negative control sera. The Spearman coefficient of the reported assay with an US-FDA approved, Taqman probe-based commercial kit was found to be 0.997. No significant difference in viral load was detected when the SYBR Green based assay was used to test infected plasma stored at -20°C and room temperature for 7 days respectively (Wilcoxon signed rank test, p = 0.105). In a comparative study on 90 pretested HIV-1 positive samples with viral loads ranging from 5,000–25,000 HIV-1 RNA copies/ml and between two commercial assays it was found that the later failed to amplify in 13.33% and 10% samples respectively while in 7.77% and 4.44% samples the copy number values were reduced by >0.5 log value, a figure that is considered clinically significant by physicians.

Conclusion

The HIV-1 viral load assay reported in this study was found to be robust, reliable, economical and effective in resource limited settings such as those existing in India. PCR probes specially designed from HIV-1 Subtype C-specific nucleotide sequences originating from India imparted specificity towards such isolates and demonstrated superior results when compared to two similar commercial assays widely used in India.  相似文献   

12.

Background

Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis.

Methodology/Principal Findings

A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%).

Conclusions/Significance

We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas.  相似文献   

13.
A plenty of natural products and synthetic derivatives containing quinoline moiety have been reported to possess various pharmacological activities. Quinolines such as 2-styrylquinolines and 8-hydroxyquinolines are extensively studied for their anti-HIV-1 activity and found to act mainly through HIV-1 integrase enzyme inhibition. In continuation of our efforts to search for newer anti-HIV-1 molecules, thirty-one quinoline derivatives with different linkers to ancillary phenyl ring were synthesized and evaluated for in vitro anti-HIV-1 activity using TZM-bl assays. Compound 31 showed higher activity in TZM-bl cell line against HIV-1VB59 and HIV-1UG070 cell associated virus (IC50 3.35 ± 0.87 and 2.57 ± 0.71 μM) as compared to other derivatives. Compound 31 was further tested against cell free virus HIV-1VB59 and HIV-1UG070 (IC50 1.27 ± 0.31 and 2.88 ± 1.79 μM, TI 42.20 and 18.61, respectively). This lead molecule also showed good activity in viral entry inhibition assay and cell fusion assay defining its mode of action. The activity of compound 31 was confirmed by testing against HIV-1VB51 in activated peripheral blood mononuclear cells (PBMCs). Binding interactions of 31 were compared with known entry inhibitors.  相似文献   

14.
Rapid detection of soluble F1 capsular antigen in serum, bubo fluid or urine of patients proved to be a valuable tool in the presumptive diagnosis of plague. We evaluated a F1 capsular antigen capture ELISA resembling a commercially available test kit. The minimal detectable concentration was 4 ng/ml. The specificity was 100% when investigating 47 sera from healthy Malagasy subjects and 98.4% when 365 sera from German blood donors were studied. Sensitivity was determined on sera (n=11) and buboes (n=18) from bacteriologically confirmed Malagasy plague patients. Sensitivity was 90.1% for serum and 100% for buboes. A standardized F1 capsular antigen capture ELISA test kit might be well suited for the early detection of plague particularly in non-endemic areas where clinical microbiological laboratories have only limited access to alternative techniques for rapid identification of Yersinia pestis.  相似文献   

15.
We evaluated two commercial enzyme immunoassay kits, Binax EIA (for detection of soluble antigen of Legionella pneumophila serogroup 1) and Biotest EIA (for detection of antigens of Legionella pneumophila serogroups and other Legionella spp.) in order to introduce this test routinely for the diagnosis of Legionnaires' disease (LD) in our Laboratory. Frozen non-concentrated urine samples belonging to 45 patients with and without LD were tested. The sensitivity of Binax EIA and Biotest EIA was 47.4% and 42.1% respectively, the specificity was 95% by both tests. Biotest did not detect antigen from a patient with culture-proven infection of L. pneumophila serogroup 6. The detection of urinary antigen by both EIA tests is a useful tool for rapid diagnosis of LD, especially when samples are unavailable for culture; the sensitivity may be increased if the assay is performed on unfrozen and concentrated samples.  相似文献   

16.
Direct injection high-performance liquid chromatographic (HPLC) methods with column switching and UV detection were developed for the rapid and accurate determination of S-1090 in human plasma and urine. An internal-surface reversed-phase pre-column and a C18 analytical column were used for the plasma assay. Two pre-columns packed with cyano and phenyl materials and a C18 analytical column were used for the urine assay. The calibration curves for plasma and urine assays were linear in the ranges 0.09–9 μg/ml and 0.5–100 μg/ml of S-1090, respectively. The relative standard deviations for plasma and urine assays were less than 6% with low relative errors. The established HPLC methods were demonstrated to be useful for clinical pharmacokinetic studies after oral administration of S-1090.  相似文献   

17.
The laborious microscopic agglutination test (MAT) is the gold standard serologic test for laboratory diagnosis of leptospirosis. We developed EIA based serologic assays using recombinant proteins (rLigA, rLigB, rLipL32) and whole-cell extracts from eight Leptospira serovars as antigen and assessed the diagnostic performance of the new assay within each class, against MAT positive (MAT+) human sera panels from Portugal/PT (n = 143) and Angola/AO (n = 100). We found that a combination of recombinant proteins rLigA, rLigB and rLipL32 correctly identified antigen-specific IgG from patients with clinical and laboratory confirmed leptospirosis (MAT+) with 92% sensitivity and ~ 97% specificity (AUC 0.974) in serum from the provinces of Luanda (LDA) and Huambo (HBO) in Angola. A combination of whole cell extracts of L. interrogans sv Copenhageni (LiC), L. kirschneri Mozdok (LkM), L. borgpetersenii Arborea (LbA) and L. biflexa Patoc (LbP) accurately identified patients with clinical and laboratory confirmed leptospirosis (MAT+) with 100% sensitivity and ~ 98% specificity for all provinces of Angola and Portugal (AUC: 0.997 for AO/LDA/HBO, 1.000 for AO/HLA, 0.999 for PT/AZ and 1.000 for PT/LIS). Interestingly, we found that MAT+ IgG+ serum from Angola had a significantly higher presence of IgD and that IgG3/IgG1 isotypes were significantly increased in the MAT+ IgG+ serum from Portugal. Given that IgM/IgD class and IgG3/IgG1 specific isotypes are produced in the earliest course of infection, immunoglobulin G isotyping may be used to inform diagnosis of acute leptospirosis. The speed, ease of use and accuracy of EIA tests make them excellent alternatives to the laborious and expensive MAT for screening acute infection in areas where circulating serovars of pathogenic Leptospira are well defined.  相似文献   

18.
Background: Different subtypes of HIV-1 are prevalent in various geographical regions. Knowledge of their distribution is of importance with respect to possible differences in biological properties (such as reported for subtype E) as well as to diagnostic problems that may arise when specific subtypes are not recognized by standard serological assays.Objectives: The objectives of this study were to investigate the presence of the five major subtypes of HIV-1 (A–E) in the Austrian population and to estimate the prevalence of the individual subtypes in different risk groups.Study design: Serum samples from 88 HIV-1 positive patients were tested for the presence of subtype-specific antibodies using a peptide ELISA.Results: The majority of the patients were shown to be infected with HIV-1 subtype B, but infections with subtypes A, C, and E were also detected in the Austrian population, primarily in the heterosexual transmission group. While subtypes A and C were probably imported from different African countries, subtype E appears to have been introduced by sex tourists returning from Thailand.Conclusion: Introduction of HIV subtypes other than B from Africa and Asia into Austria has already occurred and will certainly increase within the next few years.  相似文献   

19.

Background

The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA) and third-generation enzyme linked immunosorbent assay (EIA) for human immunodeficiency virus (HIV) screening and gauge whether the shift from EIA to ChIA could be better in a multiethnic region of China.

Methodology/Principal Findings

We identified a large number of routine specimens (345,492) using two different assays from Jan 2008 to Aug 2011 in a teaching hospital with high sample throughput. Of the 344,596 specimens with interpretable HIV test results, 526(0.23%) of 228,761 using EIA and 303(0.26%) of 115,835 using ChIA were HIV-1 positive. The false-positive rate of EIA was lower than that of ChIA [0.03% vs. 0.08%, odds ratio 0.33 (95% confidence interval 0.24, 0.45)]. The positive predictive value (PPV) of EIA (89.6%) was significantly higher than that of ChIA (76.1%) (<0.001), reflecting the difference between the two assays. The clinical sensitivities of two assays in this study were 99.64% for EIA and 99.88% for ChIA.

Conclusion

Caution is needed before shifting from 3rd to 4th generation HIV tests. Since none of these tests are perfect, different geographic and ethnic area probably require different considerations with regard to HIV testing methods, taking into account the local conditions.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号