首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Vital to patient safety is the accurate assessment and minimization of risk for human immunodeficiency virus (HIV), Hepatitis C (HCV), and Hepatitis B (HBV) virus transmission by deceased donor organ and tissue transplantation. The pathogens are tested by serological kits based on enzyme-linked immunosorbent assay (ELISA), chemiluminescence (CLIA) and eletrochemiluminescence (ECLIA) immunoassays. Organ transplantation is a highly successful life-saving treatment in Brazil, but the Brazilian Health Surveillance Agency currently mandates that all deceased organ donors are screened for HIV, HCV and HBV following living donor policies. In this review, six ELISA (Wama®, Bio-Rad®, Biomerieux®, DiaSorin®, Acon Biotech® and Biokit®), three CLIA (Abbott®, Siemens®, Diasorin®) and one ECLIA (Roche®) were utilized for evaluating the effectiveness of those serological tests for deceased donors in Brazil according to manufacturer’s guidelines. NAT for HIV, HCV and HBV can assist with detection of pre-seroconversion for those infections, and only Cobas® TaqScreen MPX® test, the Tigris System® Procleix Ultrio Assay® and the Bio-Manguinhos® HIV/HCV/HBV NAT are commercially available. Between all the tests, only the manufacturer Abbott® and Cobas® TaqScreen MPX® test are currently validated for cadaver samples.  相似文献   

2.
In order to verify the performance of the nucleic acid test (NAT) system, the precision and accuracy of the Hamilton STAR pipetting instrument in both single and pool modes were evaluated using pure water simulated for pipetting. The sensitivity, repeatability, anti-interference and anti-contamination ability of the NAT system (Roche Cobas s201) were evaluated using standard serum diluted to different concentrations. The results showed the precisions of the STAR instrument in single and pool modes were 0.07% and 0.09%, respectively, at the accuracies of 3.33% and 5.66%. The sensitivity coincidence rate of Roche Cobas s201 was 100% at the concentration of 3×LoD (Limit of Detection). The amplification was inhibited at the concentration of 2×LoD for the HBV DNA and HCV RNA when the concentration of hemolysis was greater than 7.5%. Lipemia had no effect, and the anticontamination ability was good. The detection rate in the single mode was higher than the pool mode (t=214.3156, P<0.01). This report suggests that the performance of the NAT system is adequate for laboratory purposes.  相似文献   

3.
John Saldanha 《Biologicals》1999,27(4):285-289
The introduction of nucleic acid amplification technology (NAT) assays for the detection of viral contamination of blood and blood products requires the availability of well-characterized reference reagents. Working reagents for hepatitis C virus RNA, hepatitis B virus DNA, HIV-1 RNA and human parvovirus B19 DNA have been established at NIBSC and at many other laboratories (both official medicinal control laboratories and commercial laboratories). However, as these reagents have been characterised independently, it is difficult to compare results from assays using different working reagents. Recently, a WHO International Standard was established for HCV RNA NAT assays. This standard has been calibrated in International Units (IU) and provides a common standard against which all working reagents can be calibrated. Collaborative studies to characterise two further candidate International Standards for HBV DNA and HIV-1 RNA NAT assays have been completed.  相似文献   

4.
Viral load (VL) measurements are critical to the proper management of HIV in developing countries. However, access to VL assays is limited by the high cost and complexity of existing assays. While there is a need for low cost VL assays, performance must not be compromised. Thus, new assays must be validated on metrics of limit of detection (LOD), accuracy, and dynamic range. Patient plasma samples from the Joint Clinical Research Centre in Uganda were de-identified and measured using both an existing VL assay (Abbott RealTime HIV-1) and our assay, which combines low cost reagents with a simplified method of RNA isolation termed Exclusion-Based Sample Preparation (ESP).71 patient samples with VLs ranging from <40 to >3,000,000 copies/mL were used to compare the two methods. We demonstrated equivalent LOD (~50 copies/mL) and high accuracy (average difference between methods of 0.08 log, R2 = 0.97). Using expenditures from this trial, we estimate that the cost of the reagents and consumables for this assay to be approximately $5 USD. As cost is a significant barrier to implementation of VL testing, we anticipate that our assay will enhance access to this critical monitoring test in developing countries.  相似文献   

5.
Four lots of the SET-RPLA kit (Denka Seiken Co. Ltd., Tokyo), a commercial reverse passive latex agglutination test kit for the detection of staphylococcal enterotoxins A, B, C, and D in foods, have been evaluated for their efficacy. The kits showed high specificity and sensitivity with a detection limit of 0.75 ng enterotoxin/g of food. The test is simple, is completed within 24 h, and does not require complicated extraction or concentration procedures nor expensive equipment. In addition, the assay is semiquantitative. However, as in any other immunological system, routine verification of the specificity of the latex reagents against standard enterotoxins and toxin-free food extracts is necessary.  相似文献   

6.
This report reviewed the efficacy of nucleic acid testing (NAT), derived from assaying and measuring data, using a Cobass201 system at the Dongguan blood center from 2008 to 2017. During this period, four blood screening models, each reflecting procedure improvements designed to improve residual risk (RR) assessment were assessed. A total of 716 846 blood donors were screened, detecting 1 395 positive by the mixed pool test, which were finally modified to 900 positive cases, after final detection by the separation-single test: detecting 6 HIV cases, 4 HCV cases and 890 HBV cases with a total positive rate of 1.25%. The lowest result was obtained from the twice administered enzyme-linked immunoassay (ELISA) test,used in conjunction with the single Cobas MPX v2.0 model,with rates of: 1/7 405 for HBV, 1/346 020 for HCV and 1/473 934 for HIV, respectively. NAT positive rate is not affected by different screening models. NAT is a recent detection method which can be used to good effect with ELISA, and is a worth while procedure for promoting blood transfusion safety.  相似文献   

7.
The object of this study was to develop a simple, rapid, specific, and highly sensitive method to detect HCV core antigen. A nucleic acid aptamer was designed with the high specificity and sensitivity in a nucleic acid lateral flow strip to compete with HCV core antigen and DNA probes. The lower detection limit of the test strip was calculated to be 10 pg/mL with the scanner and 100 pg/mL with naked eyes. Results showed that there were no cross-interactions with other proteins such as HCV NS3, E1/E2 antigens, HIV p24 antigens, or BSA proteins (HCV unrelated protein). When the viral load exceeded 104 copies/mL, the positive coincidence rates of ELISA and strip detection, when compared with the HCV RNA assay, were 98.44% and 97.28%, respectively. The results indicated that the ELISA detection and strip assay were in good agreement with the measured value. The results indicated that a nucleic acid lateral flow strip was a simple, rapid, specific, highly sensitive, and cost-effective field-based method for detecting HCV core antigen. The strip assay is an acceptable alternative to diagnose HCV core antigen and to investigate its epidemiology in clinical laboratories lacking specialized equipment and skills.  相似文献   

8.
Aliskiren hemifumarate (ALS) and amlodipine besylate (AML) were simultaneously determined by two different spectrofluorimetric techniques. The first technique depends on direct measurement of the steady‐state fluorescence intensities of ALS and AML at 313 nm and 452 nm upon excitation at 290 and 375 nm, respectively, in a solvent composed of methanol and water (10: 90, v/v) . The second technique utilizes synchronous fluorimetric quantitative screening of the emission spectra of ALS and AML at 272 and 366 nm, respectively using Δλ of 97 nm. Effects of different solvents and surfactants on relative fluorescence intensity were studied. The method was validated according to ICH guidelines. Linearity, accuracy and precision were found to be satisfactory in both techniques over the concentration ranges of 1–15 and 0.4–4 µg/mL for ALS and AML, respectively. In the first technique, limit of detection and limit of quantification were estimated and found to be 0.256 and 0.776 µg/mL for ALS as well as 0.067 and 0.204 µg/mL for AML, respectively. Also, limit of detection and limit of quantification were calculated in the synchronous method and found to be 0.293 and 0.887 µg/mL for ALS as well as 0.034 and 0.103 µg/mL for AML, respectively. The methods were successfully applied for the determination of the two drugs in their co‐formulated tablets. The results were compared statistically with reference methods and no significant difference was found. The developed methods are rapid, sensitive, inexpensive and accurate for the quality control and routine analysis of the cited drugs in bulk and in pharmaceutical preparations without pre‐separation. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
The first nationwide nucleic acid amplification testing (NAT) for hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type 1 (HIV-1) of voluntarily donated blood after serological pre-screening and before release of cellular components and plasma for fractionation was implemented by the Japanese Red Cross Blood Transfusion Services. From February 1, 2000 to April 30, 2001, specimens from 6,805,010 units of serologically negative donation were screened in minipools of 50 samples within 24 hr after blood donation by NAT using multiplex HBV/HCV/HIV-1 reagent for blood transfusion including short shelf-life platelets. Among them, 112 HBV DNA-positives, 25 HCV RNA positives and 4 HIV-1 RNA positives were screened out and we could prevent transfusion of these NAT positive units. Subtypes/genotypes of HBV DNA, adr/C, adw/A, adw/B, adw/C, ayr/C and ayw/D were found and adr/C was predominant. A total of 61.6 % of them (69/112) were negative by overnight EIA. Sixth three of HBV NAT-positive samples carried virus loads less than 10(4) copies/mL and 92.1 % of them (58/63) were negative by overnight EIA. The virus growth curves of HBV in 6 cases obtained by retrospective and prospective follow-up study showed exponential straight lines in the early stage of serological window periods and the log times of HBV growth (10 fold increase) in serological window period were between 4.6 and 7.6 days. NAT screening with highly sensitive reagents in pool of specimens is useful to exclude blood units with low level of HBV and HBV mutants from blood transfusion.  相似文献   

10.
Blood screening by NAT for major transfusion transmitted viral infections (TTIs) was originally intended to complement serology for detection of infected donations. Reports from developed countries showed limited marginal value to NAT blood screening in improving blood safety. Reports on NAT results from Europe indicated yield of 1:0.6 million donations for HBV, <1:M for HCV and HIV-1-related to low prevalence of TTI. In contrast, prevalence of TTI in resource-limited countries is almost always high. As a result, more incident cases can be expected among first-time blood donors. Most reports of NAT blood donation screening in these countries showed NAT confirmed yield as high as 1/2800 for HBV and 1/3100 blood donations for HCV as reported from Thailand and Egypt, respectively. The issues for low resource countries are mostly the high cost of NAT but also the requirements of staff qualification, adequate facilities, reagent procurement and maintenance of delicate equipment. Alternatives to commercial NAT are the use of combos antigen-antibody for HIV and HCV, anti-HBc for HBV and in-house NAT. Most of these alternatives have been reported but very few comparisons are available. Once yield data is available, models for estimation of feasibility and cost-effectiveness are proposed to help decision-making.  相似文献   

11.
In order to establish and screen nucleic acid test (NAT) quality control indicators for blood donor samples, CT value of each test item were detected by NAT, internal and external quality controls, the number of unsuccessful mixed samples, the split positive rate, the rate of detection efficiency, and the equipment failure rate were collected. The "instant method" is used to establish the Levey-Jennings quality control chart, the mixed test positive rate, the rate of unqualified sample. Possion distribution is used to establish the quality control chart, and it is easily to operate and monitor NAT effectively. The results displayed that quality control charts were established, including unqualified sample Possion distribution quality control chart, the rate of equipment failure quality control chart, the failure rate of reagent batch and inefficient quality control chart, test result positive of Possion distribution quality control chart, quality control charts of NAT positive Possion distribution probability, the rate of split positive quality control charts, quality control charts of unsuccessful mixed samples, quality control chart of reagents effective rate, internal quality control chart, correctness, and NAT qualitative quality control chart. The study established quality control indicators throughout the whole NAT process, which were able to effectively improve NAT quality control and the efficacy of laboratory management.  相似文献   

12.
Validation of HCV-NAT assays is an important prerequisite for the use of NAT for screening plasma or blood donations. The main NAT features to be validated are specificity, detection limit and robustness. Preliminary experience in Germany obtained with different methodical and logistic approaches shows the feasibility of HCV-NAT as a screening test for blood donations.  相似文献   

13.
目的:通过优化现有的蛋白芯片检测过程,在保证检测准确性的同时缩短甲胎蛋白(Alpha Fetal protein,AFP)的检测时间,提高检测效率,为原发性肝癌的筛查提供经济、便捷、省时、有效的检测方法。方法:本研究在传统蛋白芯片检测流程(1-1.5小时)的基础上,通过优化检测流程将检测时间缩短至18分钟,并且通过和传统方法进行比较,评价该优化方法的检测效能。结果:与传统蛋白芯片检测方法相比,本优化方法的检测时间缩短至18分钟。重复检测同一样本,传统方法 AFP水平为16.50±1.172ng/m L,优化方法 AFP水平为18.33±1.029 ng/m L,结果无明显统计学差异(P=0.251)。结论:本研究成功地优化了AFP的蛋白芯片检测流程,在缩短检测时间的同时,保证了检测的准确率,是一种经济省时易操作的AFP检测方法。  相似文献   

14.
Do-it-yourself bioanalytical equipment that requires no analytical skill to operate is currently available for use in intensive care units, operating suites, side wards, health centres, clinics, general practitioners'' surgeries, etc. Agreement is needed between the laboratory consultant and doctors and others using laboratory-type equipment and reagents in near-bedside analyses for diagnosis, clinical management, or health screening of their patients. Choice and safety of method procedure, operator training and accountability, quality control and assessment, maintenance, safety and future development of do-it-yourself equipment must be considered.  相似文献   

15.
A valid, sensitive and rapid spectrofluorimetric method has been developed and validated for determination of both tadalafil (TAD) and vardenafil (VAR) either in their pure form, in their tablet dosage forms or spiked in human plasma. This method is based on measurement of the native fluorescence of both drugs in acetonitrile at λem 330 and 470 nm after excitation at 280 and 275 nm for tadalafil and vardenafil, respectively. Linear relationships were obtained over the concentration range 4–40 and 10–250 ng/mL with a minimum detection of 1 and 3 ng/mL for tadalafil and vardenafil, respectively. Various experimental parameters affecting the fluorescence intensity were carefully studied and optimized. The developed method was applied successfully for the determination of tadalafil and vardenafil in bulk drugs and tablet dosage forms. Moreover, the high sensitivity of the proposed method permitted their determination in spiked human plasma. The developed method was validated in terms of specificity, linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), precision and accuracy. The mean recoveries of the analytes in pharmaceutical preparations were in agreement with those obtained from the comparison methods, as revealed by statistical analysis of the obtained results using Student's t‐test and the variance ratio F‐test. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
To reduce the window period between HIV-1 infection and the ability to diagnose it, a fourth-generation immunoassay including the detection of HIV-1 p24 antigen has been developed. However, because the commercially available systems for this assay use special, high-cost instruments to measure, for example, chemiluminescence, it is performed only by diagnostics companies and hub hospitals. To overcome this limitation, we applied an ultrasensitive ELISA coupled with a thio-NAD cycling, which is based on a usual enzyme immunoassay without special instruments, to detect HIV-1 p24. The p24 detection limit by our ultrasensitive ELISA was 0.0065 IU/assay (i.e., ca. 10-18 moles/assay). Because HIV-1 p24 antigen is thought to be present in the virion in much greater numbers than viral RNA copies, the value of 10-18 moles of the p24/assay corresponds to ca. 103 copies of the HIV-1 RNA/assay. That is, our ultrasensitive ELISA is chasing the detection limit (102 copies/assay) obtained by PCR-based nucleic acid testing (NAT) with a margin of only one different order. Further, the detection limit by our ultrasensitive ELISA is less than that mandated for a CE-marked HIV antigen/antibody assay. An additional recovery test using blood supported the reliability of our ultrasensitive ELISA.  相似文献   

17.
OBJECTIVE--To appraise a new method of prenatal screening for Down''s syndrome based on maternal serum concentrations of alpha fetoprotein, unconjugated oestriol, and human chorionic gonadotrophin combined with maternal age--the "triple test." DESIGN--Examination of the cost effectiveness of the triple test relative to screening only by maternal age over a range of population detection rates. SETTING--Leicestershire Health Authority. MAIN OUTCOME MEASURES--Costs per affected fetus detected. RESULTS--The triple test is more cost effective than screening only by maternal age for risk cut off points for amniocentesis, resulting in a detection rate over 45%. The most efficient detection rate is around 60-65%, for which the cost per case detected is around 29,000 pounds, through screening with higher detection rates is still likely to be cost beneficial. CONCLUSIONS--Prenatal screening for Down''s syndrome based on the triple test should replace screening based only on maternal age. Individual women''s preferences should be elicited by the use of structured decision analysis in order to maximise utility and so increase the benefits of the screening programme.  相似文献   

18.
摘 要:目的 对本实验室乙型肝炎病毒核酸(HBV DNA)定量检测程序方法学性能进行评价,以了解其方法学性能是否符合临床及本实验室检测要求。方法 分别取高浓度(HP)和低浓度(LP)两个水平的患者标本对精密度进行评价,取国家标准品(L1-L6)对正确度、线性范围及检测下限进行评价。结果 高浓度(HP)和低浓度(LP)两个水平的患者标本CV均低于5.0%,精密度符合要求;L1-L6检测结果均在国家标准品的允许范围内,正确度符合要求;a=0.9867,r2=0.9985,线性范围符合要求;国家标准品中的L4稀释后,300 IU/mL、500 IU/mL均可检出,符合试剂盒的检测灵敏度要求。结论 本室所评价的试剂盒方法学性能指标均符合要求,适合在本室开展。  相似文献   

19.
20.
A simple, rapid and highly sensitive spectrofluorimetric method was developed for determination of gemifloxacin mesylate (GFX) in tablets. The method is based on measuring the native fluorescence of GFX in isopropanol at 400 nm after excitation at 272 nm. The fluorescence–concentration plot was rectilinear over the range of 0.01–0.50 µg/mL with a lower detection limit of 1.19 ng/mL and quantification limit of 3.6 ng/mL. The method was fully validated and successfully applied to the determination of GFX tablets with an average percentage recovery of 99.65 ± 0.532. The method was extended to the stability study of GFX. The drug was exposed to acidic, alkaline, oxidative and photolytic degradation according to International Conference on Harmonization guidelines. The rate of GFX degradation was found at its highest in acidic conditions, and in its lowest in the neutral one. However, it was stable under dry heat and photolytic degradation conditions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号