首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
A reversed-phase, high-performance liquid chromatographic method employing fluorescence detection is described for the rapid quantification of plasma levels of quinidine, dihydroquinidine and 3-hydroxyquinidine. It involves protein precipitation with acetonitrile followed by direct injection of the supernatant into the chromatograph. For the preparation of plasma standards, pure 3-hydroxyquinidine was isolated from human urine by a simplified thin-layer chromatographic procedure. The mobile phase for the chromatography was a mixture of 1.5 mM aqueous phosphoric acid and acetonitrile (90:10) at a flow-rate of 2 ml/min. The intra-assay coefficient of variation for the assay of quinidine and 3-hydroxyquinidine over the concentration range 2.5–20 μmole/l was < 1% for both. Interassay coefficients of variation for quinidine (10 μmole/l) and 3-hydroxyquinidine (5 μmole/l) were 3.5% and 4.0% with detection limits of 50 and 25 μmole/l respectively. The method correlated well (r2 = 0.96) with an independently developed gas—liquid chromatographic—nitrogen detection assay for quinidine which also possessed a high degree of precision. (Intra-assay coefficient of variation 3.6% at 20 μmole/l). As expected, comparison of the high-performance liquid chromatographic assay with a published protein precipitation—fluorescence assay showed poor correlation (r2 = 0.78).  相似文献   

2.
A rapid and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of the antiarrhythmic quinidine analog, 7′-trifluoromethyldihydrocinchonidine-2HCl ([I]-2HCl) in plasma and urine. The overall recovery of [I] from plasma was 86 ± 9% with a sensitivity limit of detection of 0.2 μg/ml.The assay involves extraction of [I] into benzene-methylene chloride (9:1) from plasma or urine made alkaline with 0.1 N sodium hydroxide (pH 13) and saturated sodium chloride, the residue of which is dissolved in methylene chloride, an aliquot of which is analyzed by HPLC using adsorption chromatography on silica gel with UV detection at 254 nm. The mobile phase composed of methylene chloride-methanol-conc. ammonium hydroxide (95.5:4:0.5) yields baseline resolution of quinidine used as the internal (reference) standard, compound [I] and dihydroquinidine, a common contaminant in quinidine.The assay was applied to the analysis of plasma and urine samples taken from a dog administered a single 20 mg/kg dose via intravenous and oral routes. The stability of [I] in human plasma for up to 37 days of storage at ?17°C was also demonstrated.  相似文献   

3.
A new reversed-phase high-performance liquid chromatographic method allowing simultaneous measurement of plasma concentrations of disopyramide and quinidine is described. Disopyramide and quinidine were separated on a reversed-phase column using 0.05 M phosphate buffer (pH 3.0)—acetonitrile (73:27, v/v), as mobile phase and the peaks were monitored by UV absorbance at the wavelengths of 254 and 325 nm. The drugs were extracted from alkaline plasma with chloroform containing the internal standard. The organic phase was evaporated to dryness and the residue was redissolved in a small volume of the mobile phase before analysis by high-performance liquid chromatography. The method is convenient and reliable in routine monitoring of both drugs.  相似文献   

4.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection for the determination of vinorelbine in plasma is described. The technique was derived from that published by Debal for an assay of vinorelbine in cell culture medium. The modifications concern the preparation procedure for plasma samples (a two-step liquid-liquid extraction from plasma is desribed), optimization of the mobile phase composition, and use of a single C18 column. These changes resulted in an improved sensitivity and reproducibility of the assay and led to its feasibility for clinical pharmacokinetic studies. The range of the assay is 2 to 1000 ng/ml.  相似文献   

5.
A simple HPLC/fluorescence method to detect hydroxytolbutamide (a major metabolite of the anti-diabetic drug tolbutamide) has been developed. The effects of nicotine and some of its metabolites on tolbutamide hydroxylation is described. An extraction procedure with diethyl ether was followed by isocratic HPLC analysis of tolbutamide hydroxylation with a binary mobile phase composed of 10 mM monobasic sodium phosphate in methanol (45:55, v/v, apparent pH 2.28). A detection limit of sub-nanogram amounts (0.353 ng) of hydroxytolbutamide was obtained with fluorescence detection at 226 nm for excitation and 318 nm for emission. Overall precision values for hydroxytolbutamide was determined with coefficients of variation of 1.4–4.6% when nanogram levels of the metabolite were analyzed. Differential inhibitory responses were demonstrated for tolbutamide hydroxylation to nicotine and its metabolites. Tolbutamide hydroxylation was apparently inhibited by cotinine and relatively less inhibited by nicotine. Nornicotine, however, caused very little inhibition of tolbutamide hydroxylation. The implication is that nornicotine may not share similar affinity for the substrate binding site for tolbutamide. The results also suggest that heavy smokers may experience reduction in tolbutamide metabolism. The assay system itself will be useful for future studies of tolbutamide, and possibly related sulfonylureas.  相似文献   

6.
A sensitive and reliable assay for the quantification of l-stepholidine (SPD) in rat plasma and brain was developed using high performance liquid chromatography (HPLC) combined with fluorescence detection. Brain regions (prefrontal cortex, striatum, and cerebellum) and plasma from rats treated with SPD (10 mg/kg s.c.) 20, 40, 60, or 90 min prior to euthanasia were analyzed for SPD levels. Brain samples were homogenized in ice-cold 0.1M perchloric acid and centrifuged to remove proteins. The supernatants and diluted plasma samples, to which O-desmethylvenlafaxine was added as a process standard, were basified and extracted with ethyl acetate. The organic phase was taken to dryness and the residue taken up in mobile phase. The samples were then injected into an HPLC equipped with a fluorescence detector (excitation and emission wavelengths set at 280 and 320 nm, respectively). The mean recovery of SPD was 74.6%, and reliability studies confirmed the reproducibility of the assay (intra- and inter-assay coefficients of variation of 4.8% and 5.3%, respectively). The assay was readily applicable to the brain and plasma samples obtained from rats injected with SPD as described above; the levels and patterns of disappearance of SPD in brain regions and plasma are shown.  相似文献   

7.
A rapid, sensitive, accurate method for determination of quinidine in plasma has been developed using ion-pair extraction and high-performance liquid chromatography. The method, which is capable of distinguishing between quinidine and dihydroquinidine, involves acidification of plasma with perchloric acid, extraction with methyl isobutyl ketone and chromatography of the carbonate-washed extract on a silica gel column with a mobile phase of methylene chloride—hexane—methanol—perchloric acid (60:35:5.5:0.1) followed by fluorometric detection. The procedure is sensitive to below 50 ng/ml (coefficient of variation 6.6%) and compares favourably with a standard spectrofluorometric method when tested with plasma from volunteer subjects.  相似文献   

8.
A procedure for the separation and isolation of the urinary metabolites of quinidine and quinine by reversed-phase high-performance liquid chromatography is described. Nine metabolites of quinidine and eight metabolites of quinine were detected in the urine of male Sprague-Dawley rats after a single dose of quinidine or quinine (50 mg kg?1). Following extraction from urine, the metabolites were separated on either an analytical or a semi-preparative reversed-phase column by gradient elution. After isolation and derivatization, the metabolites were analyzed by gas chromatography and gas chromatography—mass spectrometry.  相似文献   

9.
Irinotecan (CPT-11), a camptothecin analog, is metabolized to SN-38, an active topoisomerase I inhibitor, and inactive metabolites, including APC and SN-38 glucuronide (SN-38G). A high-performance liquid chromatographic assay method to simultaneously measure the lactone and carboxylate forms of CPT-11, SN-38, SN-38G, and APC in human plasma was developed. Chromatography was accomplished with a reversed-phase C(8) column and fluorescence detection. A gradient mobile phase system was used. The buffer for mobile phase A consisted of 0.75 M ammonium acetate, 5 mM tetrabutylammonium phosphate (pH 6.0), and acetonitrile (86:14, v/v). The buffer for mobile phase B was identical to mobile phase A with the exception of the concentration (50:50, v/v). Precipitation of plasma proteins was performed with cold methanol. The linear range of detection of the lactone and carboxylate forms of SN-38, SN-38G, and APC was 2-25 ng/ml, and 5-300 ng/ml for CPT-11. The limit of quantitation for the analytes ranged from 0.5 to 5 ng/ml. Analysis of patients' plasma samples obtained before and after CPT-11 administration showed that the assay is suitable for measuring lactone and carboxylate forms of CPT-11, SN-38, SN-38G, and APC in clinical studies.  相似文献   

10.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

11.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of estramustine and its 17-keto metabolite in plasma. The assay involves extraction of the compounds into hexane from plasma buffered to pH 9.0, the residue obtained by evaporation of the hexane extract is dissolved in the mobile phase hexane—ethanol (92.5:7.5) with HPLC analysis performed on a 5-μm silica gel column using a fluorescence detector with excitation at 195 nm and emission at wavelengths greater than 250 nm. The overall recoveries and limits of sensitivity for estramustine and the 17-keto metabolite are 74.7% and 40 ng/ml of plasma and 85.1% and 50 ng/ml of plasma, respectively. The method was used to obtain plasma concentration—time profiles in three subjects with prostatic cancer following oral administration of a single 7 mg/kg dose of estramustine phosphate.  相似文献   

12.
A simple and highly sensitive high-performance liquid chromatography (HPLC) method for the simultaneous quantitative determination of lansoprazole enantiomers and their metabolites, 5-hydroxylansoprazole enantiomers and lansoprazole sulfone, in human plasma have been developed. Chromatographic separation was achieved with a Chiral CD-Ph column using a mobile phase of 0.5M NaClO(4)-acetonitrile-methanol (6:3:1 (v/v/v)). The analysis required only 100 microl of plasma and involved a solid-phase extraction with Oasis HLB cartridge, with a high extraction recovery (>94.1%) and good selectivity. The lower limit of quantification (LOQ) of this assay was 10 ng/ml for each enantiomer of both lansoprazole and 5-hydroxylansoprazole, and 5 ng/ml for lansoprazole sulfone. The coefficient of variation of inter- and intra-day assay was <8.0% and accuracy was within 8.4% for all analytes (concentration range 10-1000 ng/ml). The linearity of this assay was set between 10 and 1000 ng/ml (r2>0.999 of the regression line) for each of the five analytes. This method is applicable for accurate and simultaneous monitoring of the plasma levels of lansoprazole enantiomers and their metabolites in the renal transplant recipients.  相似文献   

13.
A simple, sensitive and reproducible HPLC method is presented for the simultaneous determination of mycophenolic acid (MPA) and its metabolites phenolic MPA-glucuronide (MPAG) and acyl glucuronide (AcMPAG) in human plasma. Sample purification requires protein precipitation with 0.1 M phosphoric acid/acetonitrile in the presence of Epilan D as an internal standard (IS). Separation was performed by reversed-phase HPLC, using a Zorbax SB-C18 column, 32% acetonitrile and a 40 mM phosphoric acid buffer at pH 3.0 as mobile phase; column temperature was 50 degrees C, flow rate 1.4 ml/min, and measurement by UV detection was at 215 nm (run time 12 min). The method requires only 50 microl plasma. Detection limits were 0.1 microg/ml for MPA and AcMPAG, and 2.0 microg/ml for MPAG, respectively. Mean absolute recovery of all three analytes was >95%. This analytical method for the determination of MPA and its metabolites is a reliable and convenient procedure that meets the criteria for application in routine clinical drug monitoring and pharmacokinetic studies.  相似文献   

14.
A simple and reproducible method for the determination of zolpidem in human plasma is presented. This method involves protein precipitation with methanol (2 ml of methanol are added to 0.5 ml of plasma) and reversed-phase chromatography with fluorescence detection (excitation wavelength 244 nm, emission wavelength 388 nm). The mobile phase consists of methanol–30 mM dihydrogen potassium phosphate–triethylamine (30:69:1). pH of the aqueous part of the mobile phase is 6.8. No internal standard is required. Limit of quantitation is 1.5 ng/ml and the calibration curve is linear up to 400 ng/ml. Within-day and between-day precision expressed by relative standard deviation is less than 5% and inaccuracy also does not exceed 9%. The assay is useful for pharmacokinetic studies.  相似文献   

15.
A procedure for determination of rifampicin and 25-desacetylrifampicin in plasma by HPLC was developed. The plasma proteins are precipitated by acetonitrile and the supernatant layer (50 microliters) is used for the assay under isocratic conditions on an analytical column 250 x 4.6 mm in size containing the reversed phase sorbent (C18). The size of the precolumn is 50 x 4.6 mm. An UV detector (at lambda 335 nm) is used. For preparing the mobile phase 630 ml of methanol and 370 ml of 0.058 M sodium nitrite solution are mixed. The flow rate of the mobile phase is 40.7 ml/min. The assay duration is about 10 min. The retention time is 9.6 min for rifampicin and 6.5 min for 25-desacetylrifampicin. The minimum detectable amount of the antibiotic and its metabolite is 0.10 micrograms/ml. The standard curves of rifampicin and 25-desacetylrifampicin are linear within the concentration ranges of 0.5-100 and 0.5-10 micrograms/ml respectively. The procedure is useful in studies on pharmacokinetics of rifampicin and 25-desacetylrifampicin.  相似文献   

16.
Thin-layer chromatography (TLC) on silica gel coated HPTLC plates, using chloroform—ethanol—water as mobile phase, is highly effective in the quantitative separation of biologically active metabolites of vitamin D. The combination of TLC and competitive protein-binding assay results in a rapid, sensitive and reproducible method for the analysis of nanogram quantities of metabolites of vitamin D3 (25-hydroxycholecalciferol, 24,25-dihydroxycholecalciferol and 25,26-dihydroxycholecalciferol) in plasma samples.  相似文献   

17.
A method for the determination of rofecoxib in human plasma is described. After the addition of an internal standard, buffered (pH 5) plasma samples are extracted with hexane–methylene chloride (50:50, v/v). The extracts are evaporated to dryness and reconstituted in mobile phase. Upon exposure to UV light, the analyte was found to undergo a stilbene–phenanthrene-like photocyclization reaction with the resulting formation of a highly fluorescent species. Thus, the plasma extracts were analyzed via HPLC with post-column photochemical derivatization and fluorescence detection. The assay has been validated in the concentration range of 0.5–100 ng/ml using 1-ml samples. The method has been successfully utilized to support human clinical pharmacokinetic studies.  相似文献   

18.
A method is described for the determination of pyronaridine in plasma using high-performance liquid chromatography with fluorescence detection. The method involves liquid-liquid extraction with phosphate buffer (pH 6.0, 0.05 M) and diethyl ether-hexane (70:30%, v/v) and chromatographic separation on a C18 column (Nucleosil, 250 × 4.6 mm I.D., 5 μm particle size) with acetonitrile-0.05 M phosphate buffer pH 6.0 (60:40%, v/v) as the mobile phase (1 ml/min) and detection by fluorescence (λex = 267 nm, λem = 443 nm). The detector response is linear up to 1000 ng and the overall recoveries pyronaridine and quinine were 90.0 and 60.3%, respectively. The assay procedure was adequately sensitive to measure 10 ng/ml pyronaridine in plasma samples with acceptable precision (< 15% C.V.). The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

19.
Ebastine (CAS 90729-43-4) is an antiallergic agent which selectively and potently blocks histamine H1-receptors in vivo. A simple and sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of ebastine and its two oxidized metabolites, carebastine (CAS 90729-42-3) and hydroxyebastine (M–OH), in human plasma. After a pretreatment of plasma sample by solid-phase extraction, ebastine and its metabolites were analyzed on an HPLC system with ultraviolet detection at 254 nm. Chromatography was performed on a cyano column (250×4.0 mm I.D.) at 40 °C with the mobile phase of acetonitrile–methanol–0.012 M ammonium acetate buffer (20:30:48, v/v/v) at a flow rate of 1.2 ml/min. Accurate determinations were possible over the concentration range of 3–1000 ng/ml for the three compounds using 1 ml plasma samples. The intra- and inter-day assay accuracy of this method were within 100±15% of nominal values and the precision did not exceed 12.4% of relative standard deviation. The lower limits of quantitation were 3 ng/ml for ebastine and its metabolites in human plasma. This method was satisfactorily applied to the determination of ebastine and its two oxidized metabolites in human plasma after oral administration of ebastine.  相似文献   

20.
A simultaneous assay for moricizine, its two sulphoxidation metabolites, morizine sulphoxide and moricizine sulphone, using high-performance liquid chromatography (HPLC) is described. The drug and metabolites and clozapine (internal standard) in biological fluids were extracted using pentanesulphonic acid into diethyl ether. The ethereal extract was evaporated to dryness and the residue was redissolved in the mobile phase (methanol-water-triethylamine, 65:35:0.5, v/v). The analyses were performed on a μBondapak reversed-phase C18 column housed in a Waters Z-module, linked to a C18 pre-column, with a run-time of 12 min. The retention times were 2.7, 3.5, 6.2 and 9.7 min for moricizine sulphone, moricizine sulphoxide, moricizine and clozapine, respectively. The recovery of the compounds from plasma ranged from 89.9% for the sulphoxide to 98.1% for clozapine. The limits of detection of the assay for moricizine, moricizine sulphoxide and moricizine sulphone were 20, 10 and 5 ng/ml, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号